Page 57
Hardware Installation
10. Rotate the AP-5131 chassis 45 degrees counter-clockwise. The clips click as they fasten to the T-bar.
11. The AP-5131 is ready to configure. For information on an AP-5131 default configuration, see Getting Started on page 3-1. For specific details on AP-5131 system configurations, see System Configuration on page 4-1. NOTE If the AP-5131 is utilizing remote management antennae, a wire cover can be used to provide a clean finished look to the installation. Contact Symbol for more information.
2.7.4 Above the Ceiling (Plenum) Installations An AP-5131 above the ceiling installation requires placing the AP-5131 above a suspended ceiling and installing the provided light pipe under the ceiling tile for viewing the rear panel status LEDs of the unit. An above the ceiling AP-5131 installation enables installations compliant with drop ceilings, suspended ceilings and industry standard tiles from .625 to .75 inches thick. NOTE The AP-5131 is Plenum rated to UL2043 and NEC1999 to support above the ceiling installations.
2-17
Page 58
2-18
AP-5131 Access Point Product Reference Guide
!
CAUTION Symbol does not recommend mounting the AP-5131 directly to any suspended ceiling tile with a thickness less than 12.7mm (0.5in.) or a suspended ceiling tile with an unsupported span greater than 660mm (26in.). Symbol strongly recommends fitting the AP-5131 with a safety wire suitable for supporting the weight of the device. The safety wire should be a standard ceiling suspension cable or equivalent steel wire between 1.59mm (.062in.) and 2.5mm (.10in.) in diameter.
The mounting hardware required to install the AP-5131 above a ceiling consists of: • • • • •
Light pipe Badge for light pipe Decal for badge Safety wire (strongly recommended) Security cable (optional)
To install the AP-5131 above a ceiling: 1. If possible, remove the adjacent ceiling tile from its frame and place it aside. 2. Install a safety wire, between 1.5mm (.06in.) and 2.5mm (.10in.) in diameter, in the ceiling space. 3. If required, install and attach a security cable to the AP-5131’s lock port. 4. Mark a point on the finished side of the tile where the light pipe is to be located. 5. Create a light pipe path hole in the target position on the ceiling tile. 6. Use a drill to make a hole in the tile the approximate size of the AP-5131 LED light pipe.
!
CAUTION Symbol recommends care be taken not to damage the finished surface of the ceiling tile when creating the light pipe hole and installing the light pipe.
7. Remove the light pipe’s rubber stopper before installing the light pipe. 8. Connect the light pipe to the bottom of the AP-5131. Align the tabs and rotate approximately 90 degrees. Do not over tighten
Page 59
Hardware Installation
Light Pipe
Ceiling Tile Decal Badge
9. Snap the clips of the light pipe into the bottom of the AP-5131. 10. Fit the light pipe into hole in the tile from its unfinished side. 11. Place the decal on the back of the badge and slide the badge onto the light pipe from the finished side of the tile. 12. Attach the radio antennae to their correct connectors.
!
CAUTION Both the Dual and Single Radio model AP-5131s use RSMA type antenna connectors. On the Dual Radio AP-5131, a single dot on the antenna connector indicates the primary antenna for both Radio 1 (2.4 GHz) and Radio 2 (5.2 GHz). Two dots designate the secondary antenna for both Radio 1 and Radio 2. On Single Radio models, a single dot on the antenna connector indicates the primary antenna for Radio 1, and two dots designate the secondary antenna for Radio 1.
13. Attach safety wire (if used) to the AP-5131 safety wire tie point or security cable (if used) to the AP-5131’s lock port. 14. Align the ceiling tile into its former ceiling space. 15. Cable the AP-5131 using either the Symbol power injector solution or an approved line cord and power supply.
!
CAUTION Do not supply power to the AP-5131 until the cabling of the unit is complete.
2-19
Page 60
2-20
AP-5131 Access Point Product Reference Guide
For Symbol power injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 Ethernet cable between the power injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the power injector and AP-5131 does not exceed 100 meters (333 ft). The power injector has no On/Off power switch. The power injector receives power as soon as AC power is applied. For more information on using the power injector, see Symbol Power Injector System on page 2-7. For standard Symbol 48-Volt Power Adapter (Part No. 50-24000-050) and line cord installations: a. Connect RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Plug the power adapter into an outlet. 16. Verify the behavior of the AP-5131 LED lightpipe. For more information, see LED Indicators on page 2-20. 17. Place the ceiling tile back in its frame and verify it is secure. The AP-5131 is ready to configure. For information on an AP-5131 default configuration, see Getting Started on page 3-1. For specific details on AP-5131 system configurations, see System Configuration on page 4-1.
2.8 LED Indicators The AP-5131 utilizes seven LED indicators. Five LEDs display within four LED slots on the front of the AP-5131 (on top of the AP-5131 housing) and two LEDs (for above the ceiling installations) are located on the back of the device (the side containing the LAN, WAN and antenna connectors).
Page 61
Hardware Installation
Power and Error Conditions (Split LED) Data Over Ethernet 802.11a Radio Activity 802.11b/g Radio Activity
The five LEDs on the top housing of the AP-5131 are clearly visible in table-top, wall and below ceiling installations. The five AP-5131 top housing LEDs have the following display and functionality:
Power Status
Solid white indicates the AP-5131 is adequately powered.
Error Conditions
Solid red indicates the AP-5131 is experiencing a problem condition requiring immediate attention.
Ethernet Activity
Flashing white indicates data transfers and Ethernet activity.
802.11a Radio Activity Flickering amber indicates beacons and data transfers over the AP-5131 802.11a radio. 802.11b/g Radio Activity
Flickering green indicates beacons and data transfers over the AP-5131 802.11b/g radio.
The LEDs on the rear of the AP-5131 are viewed using a single (customer installed) extended lightpipe, adjusted as required to suit above the ceiling installations. The LEDs displayed using the lightpipe have the following color display and functionality:
2-21
Page 62
2-22
AP-5131 Access Point Product Reference Guide
Boot and Power Status Solid white indicates the AP-5131 is adequately powered. Error Conditions
Solid red indicates the AP-5131 is experiencing a problem condition requiring immediate attention.
Power and Error Conditions
Blinking red indicates the AP-5131 Rogue AP Detection feature has located a rogue device
2.9 Setting Up MUs For a discussion of how to initially test the AP-5131 to ensure it can interoperate with the MUs intended for its operational environment, see Basic Device Configuration on page 3-3 and specifically Testing Connectivity on page 3-11. Refer to the LA-5030 & LA-5033 Wireless Networker PC Card and PCI Adapter Users Guide, available from the Symbol Web site, for installing drivers and client software if operating in an 802.11a/g network environment. Refer to the Spectrum24 LA-4121 PC Card, LA-4123 PCI Adapter & LA-4137 Wireless Networker User Guide, available from the Symbol Web site, for installing drivers and client software if operating in an 802.11b network environment. Use the default values for the ESSID and other configuration parameters until the network connection is verified. MUs attach to the network and interact with the AP transparently.