Page 49
Hardware Installation
2.6.1 Installing the Power Injector Refer to the following sections for information on planning, installing, and validating the power injector installation: • • •
Preparing for Site Installation Cabling the Power Injector Power Injector LED Indicators
2.6.1.1 Preparing for Site Installation The power injector can be installed free standing, on an even horizontal surface or wall mounted using the power injector’s wall mounting key holes. The following guidelines should be adhered to before cabling the power injector to an Ethernet source and an AP-5131: • • •
Do not block or cover airflow to the power injector. Keep the power injector away from excessive heat, humidity, vibration and dust. The power injector is not a repeater, and does not amplify the Ethernet data signal. For optimal performance, ensure the power injector is placed as close as possible to the network data port.
2.6.1.2 Cabling the Power Injector To install the power injector to an Ethernet data source and AP-5131:
!
CAUTION Ensure AC power is supplied to the power injector using an AC cable with an appropriate ground connection approved for the country of operation.
1. Connect the power injector to an AC outlet (110VAC to 220VAC). 2. Connect an RJ-45 Ethernet cable between the network data supply (host) and the power injector Data In connector. 3. Connect an RJ-45 Ethernet cable between the power injector Data & Power Out connector and the Symbol AP-5131 LAN port.
!
CAUTION Cabling the power injector to the AP-5131’s WAN port renders the AP-5131 non-operational. Only use a AP-PSBIAS-T-1P-AF model power injector with the AP-5131’s LAN port.
2-9
Page 50
2-10
AP-5131 Access Point Product Reference Guide
Ensure the cable length from the Ethernet source (host) to the power injector and AP-5131 does not exceed 100 meters (333 ft.)
The power injector has no On/Off power switch. The power injector receives power and is ready for AP-5131 device connection and operation as soon as AC power is applied.
2.6.1.3 Power Injector LED Indicators The power injector demonstrates the following LED behavior under normal and/or problematic operating conditions: LED Green (Steady)
AC (Main)
Port
Power injector is receiving power from AC Indicates a device is connected to the outlet. power injector’s outgoing Data & Power cable.
Green (Blinking) Output voltage source is out of range.
The power injector is overloaded or has a short circuit.
Page 51
Hardware Installation
For more information and device specifications for the Symbol power injector, refer to the Power Injector Quick Install Guide (Part No. 72-66153-01) available from the Symbol Web site or the AP-5131 Software and documentation CDROM.
2.7 Mounting the AP-5131 The AP-5131 can rest on a flat surface, attach to a wall, mount under a suspended T-Bar or above a ceiling (plenum or attic). Choose one of the following mounting options based on the physical environment of the coverage area. Do not mount the AP-5131 in a location that has not been approved in a site survey. Refer to the following, depending on how you intend to mount the AP-5131: • • • •
Desk Mounted Installations Wall Mounted Installations Suspended Ceiling T-Bar Installations Above the Ceiling (Plenum) Installations
2.7.1 Desk Mounted Installations The desk mount option uses rubber feet allowing the unit to sit on most flat surfaces. The four (4) round rubber feet can be found in the AP-5131 (main) box in a separate plastic bag. To install the AP-5131 in a desk mount orientation: 1. Turn the AP-5131 upside down. 2. Attach the radio antennae to their correct connectors.
!
CAUTION Both the Dual and Single Radio model AP-5131’s use RSMA type antenna connectors. On the Dual Radio AP-5131, a single dot on the antenna connector indicates the primary antenna for both Radio 1 (2.4 GHz) and Radio 2 (5.2 GHz). Two dots designate the secondary antenna for both Radio 1 and Radio 2. On Single Radio models, a single dot on the antenna connector indicates the primary antenna for Radio 1, and two dots designate the secondary antenna for Radio 1.
3. Remove the backings from the four (4) rubber feet and attach them to the four rubber feet recess areas on the AP-5131.
2-11
Page 52
2-12
AP-5131 Access Point Product Reference Guide
4. Cable the AP-5131 using either the Symbol power injector solution or an approved line cord and power supply.
!
CAUTION Do not supply power to the AP-5131 until the cabling of the unit is complete.
For Symbol power injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the power injector Data In connector. b. Connect a RJ-45 Ethernet cable between the power injector Data & Power Out connector and the Symbol AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the power injector and AP-5131 does not exceed 100 meters (333 ft). The power injector has no On/Off power switch. The power injector receives power as soon as AC power is applied. For more information on using the power injector, see Symbol Power Injector System on page 2-7. For standard Symbol 48-Volt power adapter (Part No. 50-24000-050) and line cord installations: a. Connect RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Plug the power adapter into an outlet.
Page 53
Hardware Installation
5. Verify the behavior of the AP-5131 LEDs. For more information, see LED Indicators on page 2-20. 6. Return the AP-5131 to an upright position and place it in the location you wish it to operate. Ensure the AP-5131 is sitting evenly on all four rubber feet. The AP-5131 is ready to configure. For information on an AP-5131 default configuration, see Getting Started on page 3-1. For specific details on AP-5131 system configurations, see System Configuration on page 4-1.
2.7.2 Wall Mounted Installations Wall mounting requires hanging the AP-5131 along its width (or length) using the pair of slots on the bottom of the unit and using the AP-5131 itself as a mounting template for the screws. The AP-5131 can be mounted onto any plaster or wood wall surface. The mounting hardware and tools (customer provided) required to install the AP-5131 on a wall consists of: •
• •
Two Phillips pan head self-tapping screws (ANSI Standard) #6-18 X 0.875in. Type A or AB Self-Tapping screw, or (ANSI Standard Metric) M3.5 X 0.6 X 20mm Type D Self-Tapping screw Two wall anchors Security cable (optional)
To mount the AP-5131 on a wall: 1. Orient the AP-5131 on the wall by its width or length. 2. Using the arrows on one edge of the case as guides, move the edge to the midline of the mounting area and mark points on the midline for the screws. 3. At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall mounting screw and stop when there is 1mm between the screw head and the wall. If pre-drilling a hole, the recommended hole size is 2.8mm (0.11in.) if the screws are going directly into the wall and 6mm (0.23in.) if wall anchors are being used. 4. If required, install and attach a security cable to the AP-5131 lock port. 5. Place the large corner of each of the mount slots over the screw heads. 6. Slide the AP-5131 down along the mounting surface to hang the mount slots on the screw heads. 7. Attach the radio antennae to their correct connectors.
2-13
Page 54
2-14
AP-5131 Access Point Product Reference Guide
!
CAUTION Both the Dual and Single Radio model AP-5131s use RSMA type antenna connectors. On the Dual Radio AP-5131, a single dot on the antenna connector indicates the primary antenna for both Radio 1 (2.4 GHz) and Radio 2 (5.2 GHz). Two dots designate the secondary antenna for both Radio 1 and Radio 2. On Single Radio models, a single dot on the antenna connector indicates the primary antenna for Radio 1, and two dots designate the secondary antenna for Radio 1.
8. Cable the AP-5131 using either the Symbol power injector solution or an approved line cord and power supply. NOTE The AP-5131 must be mounted with the RJ45 cable connector oriented upwards to ensure proper operation.
!
CAUTION Do not supply power to the AP-5131 until the cabling of the unit is complete.
For Symbol power injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 Ethernet cable between the power injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the power injector and AP-5131 does not exceed 100 meters (333 ft). The power injector has no On/Off power switch. The power injector receives power as soon as AC power is applied. For more information on using the power injector, see Symbol Power Injector System on page 2-7. For standard Symbol 48-Volt Power Adapter (Part No. 50-24000-050) and line cord installations: a. Connect RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131.
Page 55
Hardware Installation e. Plug the power adapter into an outlet. NOTE If the AP-5131 is utilizing remote management antennae, a wire cover can be used to provide a clean finished look to the installation. Contact Symbol for more information. 9. Verify the behavior of the AP-5131 LEDs. For more information, see LED Indicators on page 2-20. The AP-5131 is ready to configure. For information on an AP-5131 default configuration, see Getting Started on page 3-1. For specific details on AP-5131 system configurations, see System Configuration on page 4-1.
2.7.3 Suspended Ceiling T-Bar Installations A suspended ceiling mount requires holding the AP-5131 up against the T-bar of a suspended ceiling grid and twisting the AP-5131 chassis onto the T-bar. The mounting hardware and tools (customer provided) required to install the AP-5131 on a ceiling Tbar consists of: • •
Safety wire (recommended) Security cable (optional)
To install the AP-5131 on a ceiling T-bar: 1. If required, loop a safety wire, with a diameter of at least 1.01 mm (.04 in.), but no more than 0.158 mm (.0625 in.), through the tie post (above the AP-5131’s console connector) and secure the loop. 2. If required, install and attach a security cable to the AP-5131 lock port. 3. Attach the radio antennae to their correct connectors.
!
CAUTION Both the Dual and Single Radio model AP-5131s use RSMA type antenna connectors. On the Dual Radio AP-5131, a single dot on the antenna connector indicates the primary antenna for both Radio 1 (2.4 GHz) and Radio 2 (5.2 GHz). Two dots designate the secondary antenna for both Radio 1 and Radio 2. On Single Radio models, a single dot on the antenna connector indicates the primary antenna for Radio 1, and two dots designate the secondary antenna for Radio 1
2-15
Page 56
2-16
AP-5131 Access Point Product Reference Guide
4. Cable the AP-5131 using either the Symbol power injector solution or an approved line cord and power supply.
!
CAUTION Do not supply power to the AP-5131 until the cabling of the unit is complete.
For Symbol power injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 Ethernet cable between the power injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the power injector and AP-5131 does not exceed 100 meters (333 ft). The power injector has no On/Off power switch. The power injector receives power as soon as AC power is applied. For more information on using the power injector, see Symbol Power Injector System on page 2-7. For standard Symbol 48-Volt Power Adapter (Part No. 50-24000-050) and line cord installations:
6. 7. 8. 9.
a. Connect RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Plug the power adapter into an outlet. Verify the behavior of the AP-5131 LEDs. For more information, see LED Indicators on page 2-20. Align the bottom of the ceiling T-bar with the back of the AP-5131. Orient the AP-5131 chassis by its length and the length of the ceiling T-bar. Rotate the AP-5131 chassis 45 degrees clockwise, or about 10 o’clock. Push the back of the AP-5131 chassis on to the bottom of the ceiling T-bar.
!
CAUTION Ensure the safety wire and cabling used in the T-Bar AP-5131 installation is securely fastened to the building structure in order to provide a safe operating environment.
5.