AP-5131 Access Point Installation Guide: 3.0 Hardware Installation, pages 20 to 27

Pages 20 to 27 of 50, from AP-5131 Access Point Installation Guide

The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol AP-5131

Page 20

72-70931_01.book Page 14 Monday, May 4, 2009 8:10 AM

14

AP-5131 Access Point: Installation Guide

2. Using the arrows on one edge of the case as guides, move the edge to the midline of the mounting area and mark points on the midline for the screws. 3. At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall mounting screw and stop when there is 1mm between the screw head and the wall. If pre-drilling a hole, the recommended hole size is 2.8mm (0.11in.) if the screws are going directly into the wall and 6mm (0.23in.) if wall anchors are being used. 4. If required, install and attach a security cable to the AP-5131 lock port. 5. Attach the Radio 1 and/or Radio 2 antennas to their correct connectors. 6. For information on the antennas available to the AP-5131, see “AP-5131 Antenna Options” on page 6. 7. Place the large corner of each of the mount slots over the screw heads. 8. Slide the AP-5131 down along the mounting surface to hang the mount slots on the screw heads.

!

CAUTION

NOTE

Ensure you are placing the antennas on the correct connectors (depending on your single or dual-radio model and frequency used) to ensure the successful operation of the AP-5131.

The AP-5131 must be mounted with the RJ45 cable connector oriented upwards to ensure proper operation.

9. Cable the AP-5131 using either the Power Injector solution or an approved line cord and power supply. For Motorola Power Injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the Power Injector and AP-5131 does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For more information on using the Power Injector, see “Power Injector System” on page 8.

Page 21

72-70931_01.book Page 15 Monday, May 4, 2009 8:10 AM

Hardware Installation

For standard power adapter (non Power Injector) and line cord installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Attach the power supply line cord to a power supply.

!

CAUTION

Do not actually connect to the power source until the cabling portion of the installation is complete.

10. Verify the behavior of the AP-5131 LEDs. For more information, see “LED Indicators” on page 21. 11. The AP-5131 is ready to configure. For information on basic AP-5131 device configuration, see “Configuring “Basic” Device Settings” on page 25. NOTE

3.4.3

If the AP-5131 is utilizing remote management antennas, a wire cover can be used to provide a clean finished look to the installation. Contact Motorola for more information.

Suspended Ceiling T-Bar Installations

A suspended ceiling mount requires holding the AP-5131 up against the T-bar of a suspended ceiling grid and twisting the AP-5131 chassis onto the T-bar. The mounting hardware and tools (customer provided) required to install the AP-5131 on a ceiling T-bar consists of: • •

Safety wire (recommended) Security cable (optional)

To install the AP-5131 on a ceiling T-bar: 1. If required, loop a safety wire, with a diameter of at least 1.01 mm (.04 in.), but no more than 0.158 mm (.0625 in.), through the tie post (above the AP-5131’s console connector) and secure the loop. 2. If required, install and attach a security cable to the AP-5131 lock port.

15

Page 22

72-70931_01.book Page 16 Monday, May 4, 2009 8:10 AM

16

AP-5131 Access Point: Installation Guide

3. Attach the Radio 1 and/or Radio 2 antennas to their correct connectors. For information on the antennas available to the AP-5131, see “AP-5131 Antenna Options” on page 6.

!

CAUTION

Ensure you are placing the antennas on the correct connectors (depending on your single or dual-radio model and frequency used) to ensure the successful operation of the AP-5131.

4. Cable the AP-5131 using either the Power Injector solution or an approved line cord and power supply. For Motorola Power Injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the Power Injector and AP-5131 does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For more information, see “Power Injector System” on page 8. For standard power adapter (non Power Injector) and line cord installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Attach the power supply line cord to a power supply.

!

CAUTION

Do not actually connect to the power source until the cabling portion of the installation is complete.

5. Verify the behavior of the AP-5131 LEDs. For more information, see “LED Indicators” on page 21. 6. Align the bottom of the ceiling T-bar with the back of the AP-5131. 7. Orient the AP-5131 chassis by its length and the length of the ceiling T-bar.

Page 23

72-70931_01.book Page 17 Monday, May 4, 2009 8:10 AM

Hardware Installation

8. Rotate the AP-5131 chassis 45 degrees clockwise, or about 10 o’clock. 9. Push the back of the AP-5131 chassis on to the bottom of the ceiling T-bar.

!

CAUTION

Ensure the safety wire and cabling used in the T-Bar AP-5131 installation is securely fastened to the building structure in order to provide a safe operating environment.

10. Rotate the AP-5131 chassis 45 degrees counter-clockwise. The clips click as they fasten to the T-bar.

11. The AP-5131 is ready to configure. For information on basic AP-5131 device configuration, see “Configuring “Basic” Device Settings” on page 25. NOTE

3.4.4

If the AP-5131 is utilizing remote management antennas, a wire cover can be used to provide a clean finished look to the installation. Contact Motorola for more information.

Above the Ceiling (Plenum) Installations

An AP-5131 above the ceiling installation requires placing the AP-5131 above a suspended ceiling and installing the provided light pipe under the ceiling tile for viewing the rear panel status LEDs of

17

Page 24

72-70931_01.book Page 18 Monday, May 4, 2009 8:10 AM

18

AP-5131 Access Point: Installation Guide the unit. An above the ceiling AP-5131 installation enables installations compliant with drop ceilings, suspended ceilings and industry standard tiles from .625 to .75 inches thick. NOTE

The AP-5131 is Plenum rated to UL2043 and NEC1999 for above the ceiling installations.

CAUTION

!

Motorola does not recommend mounting the AP-5131 directly to any suspended ceiling tile with a thickness less than 12.7mm (0.5in.) or a suspended ceiling tile with an unsupported span greater than 660mm (26in.). Motorola strongly recommends fitting the AP-5131 with a safety wire suitable for supporting the weight of the device. The safety wire should be a standard ceiling suspension cable or equivalent steel wire between 1.59mm (.062in.) and 2.5mm (.10in.) in diameter.

The mounting hardware required to install the AP-5131 above a ceiling consists of: • • • • •

Light pipe Badge for light pipe Decal for badge Safety wire (strongly recommended) Security cable (optional)

To install the AP-5131 above a ceiling: 1. If possible, remove the adjacent ceiling tile from its frame and place it aside. 2. If required, install a safety wire, between 1.5mm (.06in.) and 2.5mm (.10in.) in diameter, in the ceiling space. 3. If required, install and attach a security cable to the AP-5131’s lock port. 4. Mark a point on the finished side of the tile where the light pipe is to be located. 5. Create a light pipe path hole in the target position on the ceiling tile. 6. Use a drill to make a hole in the tile the approximate size of the AP-5131 LED light pipe.

!

CAUTION

Motorola recommends care be taken not to damage the finished surface of the ceiling tile when creating the light pipe hole and installing the light pipe.

Page 25

72-70931_01.book Page 19 Monday, May 4, 2009 8:10 AM

Hardware Installation

7. Remove the light pipe’s rubber stopper (from the AP-5131) before installing the light pipe. 8. Connect the light pipe to the bottom of the AP-5131. Align the tabs and rotate approximately 90 degrees. Do not over tighten.

Light Pipe

Ceiling Tile Decal Badge

9. Snap the clips on the light pipe into the bottom of the AP-5131. 10. Fit the light pipe into hole in the tile from its unfinished side. 11. Place the decal on the back of the badge and slide the badge onto the light pipe from the finished side of the tile. 12. Attach the Radio 1 and/or Radio 2 antennas to their correct connectors. For information on the antennas available to the AP-5131, see “AP-5131 Antenna Options” on page 6.

!

CAUTION

Ensure you are placing the antennas on the correct connectors (depending on your single or dual-radio model and frequency used) to ensure the successful operation of the AP-5131.

13. Attach safety wire (if used) to the AP-5131 safety wire tie point or security cable (if used) to the AP-5131’s lock port. 14. Align the ceiling tile into its former ceiling space. 15. Cable the AP-5131 using either the Power Injector solution or an approved line cord and power supply. For Motorola Power Injector installations:

19

Page 26

72-70931_01.book Page 20 Monday, May 4, 2009 8:10 AM

20

AP-5131 Access Point: Installation Guide a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the Power Injector and AP-5131 does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For more information on using the Power Injector, see “Power Injector System” on page 8. For standard power adapter (non Power Injector) and line cord installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Attach the power supply line cord to a power supply.

!

CAUTION

Do not actually connect to the power source until the cabling portion of the installation is complete.

16. Verify the behavior of the AP-5131 LED light pipe. For more information, see “LED Indicators” on page 21. 17. Place the ceiling tile back in its frame and verify it is secure. 18. The AP-5131 is ready to configure. For information on basic AP-5131 device configuration, see “Configuring “Basic” Device Settings” on page 25.

Page 27

72-70931_01.book Page 21 Monday, May 4, 2009 8:10 AM

Hardware Installation

3.5 LED Indicators The AP-5131 utilizes seven LED indicators. Five LEDs display within four LED slots on the front of the AP-5131 (on top of the AP-5131 housing) and two LEDs (for above the ceiling installations) are located on the back of the device (the side containing the LAN, WAN and antenna connectors). 0OWER AND %RROR #ONDITIONS ,%$ $ATA /VER %THERNET A 2ADIO !CTIVITY 2ADIO !CTIVITY

The five LEDs on the top housing of the AP-5131 are clearly visible in table-top, wall and below ceiling installations. The five AP-5131 top housing LEDs have the following display and functionality: Boot and Power Status

Solid white indicates the AP-5131 is adequately powered.

Error Conditions

Solid red indicates the AP-5131 is experiencing a problem condition requiring immediate attention.

Ethernet Activity

Flashing white indicates data transfers and Ethernet activity.

802.11a Radio Activity

Flickering amber indicates beacons and data transfers over the AP-5131 802.11a radio.

21