The text of a manual · part 3 of 7
AP-5131 Access Point Installation Guide: 3.0 Hardware Installation, pages 11 to 19
Pages 11 to 19 of 50, from AP-5131 Access Point Installation Guide
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol AP-5131
Page 11
72-70931_01.book Page 5 Monday, May 4, 2009 8:10 AM
Hardware Installation
3
Hardware Installation
An AP-5131 installation includes mounting the AP-5131 on a table-top, wall, ceiling T-bar or above the ceiling orientation, connecting the AP-5131 to the network (LAN or WAN port connection), connecting antennas and applying power. Installation procedures vary for different environments.
3.1 Precautions Before installing the AP-5131 verify the following: • •
3.2
Do not install in wet or dusty areas without additional protection. Contact a Motorola representative for more information. Verify the environment has a continuous temperature range between -20° C to 50° C.
Package Contents
Check package contents for the correct model AP-5131 and applicable AP-5131 accessories. Each available configuration (at a minimum), contains: •
• •
AP-5131 (two base models available) • Single 802.11a/g radio, external antenna (Part No. AP-5131-4002X-WWR) • Dual 802.11a+g radio, external antenna (Part No. AP-5131-1304X-WWR) AP-5131 Install Guide Accessories Bag (4 rubber feet for desk mounting and a LED light pipe and badge with label for above the ceiling installations) NOTE
There are numerous SKUs available containing at least one AP-5131 radio model (either 802.11a or 802.11b/g), Install Guide and Accessories Bag. However, some SKUs contain various antenna and Motorola Power Injector combinations. Refer to the AP-51xx Product Reference Guide to familiarize yourself with all available AP-5131 product SKUs. The guide is available on the Motorola Web site, at http://support.symbol.com/support/product/manuals.do.
Verify the model indicated on the bottom of the AP-5131 is correct. Contact the Motorola Support Center to report missing or improperly functioning items.
5
Page 12
72-70931_01.book Page 6 Monday, May 4, 2009 8:10 AM
6
AP-5131 Access Point: Installation Guide
3.3 AP-5131 Placement For optimal performance, install the AP-5131 away from transformers, heavy-duty motors, fluorescent lights, microwave ovens, refrigerators and other industrial equipment. Signal loss can occur when metal, concrete, walls or floors block transmission. Install the AP-5131 in open areas or add access points as needed to improve coverage. Place the AP-5131 using the following guidelines: • • •
Install the AP-5131 at an ideal height of 10 feet from the ground. Orient the AP-5131 antenna vertically for best reception. Point the AP-5131 antenna(s) downward if attaching to the ceiling.
Motorola recommends conducting a site survey to define and document radio interference obstacles before installing the AP-5131 to maximize its radio coverage area.
3.3.1
AP-5131 Antenna Options
Both Radio 1 and Radio 2 require one antenna and can optimally use two antennas per radio (4 antennas total for dual-radio models). Two antennas per radio provides diversity that can improve performance and signal reception. Motorola supports two antenna suites for the AP-5131. One antenna suite supporting the 2.4 GHz band and another antenna suite supporting the 5.2 GHz band. Select an antenna model best suited to the intended operational environment of your AP-5131. NOTE On a single-radio AP-5131, Radio 1 can be configured to be either a 2.4 GHz or 5.2 GHz radio. On a dual-radio model, Radio 1 refers to the AP5131’s 2.4 GHz radio and Radio 2 refers to the AP-5131 5.2 GHz radio. However, there could be some cases where a dual-radio AP-5131 is performing a Rogue AP detector function. In this scenario, the AP-5131 is receiving in either 2.4 GHz or 5.2 GHz over the Radio 1 or Radio 2 antennas depending on which radio is selected for the scan. Antenna connectors for Radio 1 are located in a different location from the Radio 2 antenna connectors. On single radio versions, the R-SMA connectors can support both bands and should be connected to a R-SMA dual-band antenna or an appropriate single band antenna. If necessary a R-SMA to R-BNC adapter (Part No. 25-72178-01) can be purchased separately from Motorola.
Page 13
72-70931_01.book Page 7 Monday, May 4, 2009 8:10 AM
Hardware Installation
Certain Rogue AP Detection and Intrusion Detection features use an AP-5131 radio to perform dualband scanning. The dedicated radio should be connected to an appropriate dual-band dipole antenna (Part No. ML-2452-APA2-01).
The 2.4 GHz antenna suite includes the following models: Part Number
Antenna Type
Nominal Net Gain (dBi)
ML-2499-11PNA2-01R
Wide Angle Directional
8.5
ML-2499-HPA3-01R
Omni-Directional Antenna
3.3
ML-2499-BYGA2-01R
Yagi Antenna
13.9
ML-2452-APA2-01
Dual-Band
3.0
NOTE
An additional adapter is required to use ML-2499-11PNA2-01R and ML-2499-BYGA2-01R model antennas. Please contact Motorola for more information.
7
Page 14
72-70931_01.book Page 8 Monday, May 4, 2009 8:10 AM
8
AP-5131 Access Point: Installation Guide
The 5.2 GHz antenna suite includes the following models: Part Number
Antenna Type
Nominal Net Gain (dBi)
ML-5299-WPNA1-01R
Panel Antenna
13.0
ML-5299-HPA1-01R
Wide-Band Omni-Directional Antenna
5.0
ML-2452-APA2-01
Dual-Band
4.0
For detailed specifications on the antennas available to the AP-5131, refer to the AP-51xx Product Reference Guide. Appendix A of that document contains detailed AP-5131 antenna specifications and their instructions for optimal use. The guide is available on the Motorola Web site, at http://support.symbol.com/support/product/manuals.do.
3.3.2 Power Injector System The AP-5131 can receive power either directly form a Motorola 48V AC-DC power supply (Part No. 50-14000-243R) or via an Ethernet cable connected to the LAN port (using the 802.3af standard). When users purchase a Motorola WLAN solution, they often need to place access points in obscure locations. In the past, a dedicated power source was required for each access point in addition to the Ethernet infrastructure. This often required an electrical contractor to install power drops at each access point location. An approved power injector solution merges power and Ethernet into one cable, reducing the burden of installation and allows optimal AP-5131 placement in respect to the intended radio coverage area. The Power Injector is included in certain AP-5131 kits. The Power Injector (Part No. AP-PSBIAS-1P2-AFR) is an integrated AC-DC converter and 802.3af power injector which requires 110-220V AC power to combine low-voltage DC with Ethernet data in a single cable connecting to the AP-5131. The Motorola AP-5131 Power Supply (Part No. 50-14000-243R) is not included in the kit and is orderable separately as an accessory. CAUTION
!
The AP-5131 supports any standards-based 802.3af compliant power source (including non-Motorola power sources). However, using the wrong solution (including a POE system used on a legacy Motorola access point) could severely damage the AP-5131 and void the product warranty.
Page 15
72-70931_01.book Page 9 Monday, May 4, 2009 8:10 AM
Hardware Installation
A separate Power Injector is required for each AP-5131 comprising the network.
Data
Power
Power Injector to AP-5131 LAN Port
AP-5131
Wireless LAN
The Power Injector can be installed free standing, on an even horizontal surface or wall mounted using the power injector’s wall mounting key holes. The following guidelines should be adhered to before cabling the Power Injector to an Ethernet source and an AP-5131: • • •
Do not block or cover airflow to the Power Injector. Keep the Power Injector away from excessive heat, humidity, vibration and dust. The Power Injector is not a repeater, and does not amplify the Ethernet data signal. For optimal performance, ensure the Power Injector is placed as close as possible to the network data port.
9
Page 16
72-70931_01.book Page 10 Monday, May 4, 2009 8:10 AM
10
AP-5131 Access Point: Installation Guide
To install the Power Injector to an Ethernet data source and AP-5131:
!
CAUTION
Ensure AC power is supplied to the Power Injector using an AC cable with an appropriate ground connection approved for the country of operation.
1. Connect the Power Injector to an AC outlet (110VAC to 220VAC). 2. Connect an RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. 3. Connect an RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the AP-5131 LAN port. NOTE
Cabling the Power Injector to the AP-5131’s WAN port renders the AP-5131 non-operational. Only use a AP-PSBIAS-1P2-AFR model power injector with the AP-5131’s LAN port.
Ensure the cable length from the Ethernet source (host) to the Power Injector and AP-5131 does not exceed 100 meters (333 ft).
The Power Injector has no On/Off power switch. The Power Injector receives power and is ready for AP-5131 device connection and operation as soon as AC power is applied.
Page 17
72-70931_01.book Page 11 Monday, May 4, 2009 8:10 AM
Hardware Installation
The Power Injector demonstrates the following LED behavior under normal and/or problematic operating conditions: LED
AC (Main)
Port
Green (Steady)
Power Injector is receiving power from AC outlet
Indicates a device is connected to the Power Injector’s outgoing Data & Power cable
Green (Blinking)
Output voltage source is out The Power Injector is of range overloaded or has a short circuit
For more information and device specifications for the Power Injector, refer to the Power Injector Quick Install Guide (Part No. # 72-99410-01) available from the Motorola Web site, at http://support.symbol.com/support/product/manuals.do.
3.4 Mounting the AP-5131 The AP-5131 can rest on a flat surface, attach to a wall, mount under a suspended T-Bar or above a ceiling (plenum or attic). Choose one of the following mounting options based on the physical environment of the coverage area. Do not mount the AP-5131 in a location that has not been approved in a site survey.
3.4.1 Desk Mounting The desk mount option uses rubber feet (found in the accessories bag shipped with the AP-5131) allowing the unit to sit on most flat surfaces. To install the AP-5131 in a desk mount orientation: 1. Turn the AP-5131 upside down. 2. Remove the backings from the four (4) rubber feet and attach them to the four rubber feet recess areas on the AP-5131.
11
Page 18
72-70931_01.book Page 12 Monday, May 4, 2009 8:10 AM
12
AP-5131 Access Point: Installation Guide
3. Attach the Radio 1 and/or Radio 2 antennas to their correct connectors. The antenna covers will most likely need to be removed to orient the antenna upward in a typical desktop installation. For information on the antennas available to the AP-5131, see “AP-5131 Antenna Options” on page 6.
!
CAUTION
Ensure you are placing the antennas on the correct connectors (depending on your single or dual-radio model and frequency used) to ensure the successful operation of the AP-5131.
4. Cable the AP-5131 using either the Motorola Power Injector solution or an approved line cord and power supply. For Motorola Power Injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the Power Injector and AP-5131 does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For more information on using the Power Injector, see “Power Injector System” on page 8. For standard power adapter (non Power Injector) and line cord installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port.
Page 19
72-70931_01.book Page 13 Monday, May 4, 2009 8:10 AM
Hardware Installation b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Attach the power supply line cord to a power supply
!
CAUTION
Do not actually connect to the power source until the cabling portion of the installation is complete.
5. Verify the behavior of the AP-5131 LEDs. For more information, see “LED Indicators” on page 21. 6. Return the AP-5131 to an upright position and place it in the location you wish it to operate. Ensure the AP-5131 is sitting evenly on all four rubber feet. 7. The AP-5131 is ready to configure. For information on basic AP-5131 device configuration, see “Configuring “Basic” Device Settings” on page 25.
3.4.2
Wall Mounting
Wall mounting requires hanging the AP-5131 along its width (or length) using the pair of slots on the bottom of the unit and using the AP-5131 itself as a mounting template for the screws.
!
CAUTION
An AP-5131 should be wall mounted to concrete or plaster-wall-board (dry wall) only. Do not wall mount an AP-5131 to combustible surfaces.
The mounting hardware and tools (customer provided) required to install the AP-5131 on a wall consists of: •
• •
Two Phillips pan head self-tapping screws (ANSI Standard) #6-18 X 0.875in. Type A or AB Self-Tapping screw, or (ANSI Standard Metric) M3.5 X 0.6 X 20mm Type D Self-Tapping screw Two wall anchors Security cable (optional)
To mount the AP-5131 on a wall: 1. Orient the AP-5131 on the or ceiling by its width or length.
13