Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 26

Spectrum24 AP-4121 Access Point Product Reference Guide: Chapter 2 Configuring the AP, pages 49 to 58

Pages 49 to 58 of 236, from Spectrum24 AP-4121 Access Point Product Reference Guide

The original document is the PDF (3.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol AP-4121

Page 49

Chapter 2

Configuring the AP AP configuration requires setting up a connection to the AP and gaining access to the UI (User Interface). The methods of accessing the UI are Serial, Telnet, Web, and SNMP. DHCP is enabled on the AP by default. Initial network configuration can be obtained from a DHCP server. All except Serial require the configuration of an IP address. To access the AP through the serial port and terminal emulation program, connect to the DB9 serial port using a null modem cable. Set the terminal emulation program for 19,200 bps, 8 bits, No parity, 1 Stop Bit and No flow control. Select the AP Installation screen and enter the appropriate IP configuration parameters for the network. The dot in front of certain parameters, functions or options (.Antenna Selection Primary Only) indicates these items update to all APs with the same Net_ID (ESS) when choosing the Save ALL APs-[F2] option. Users can perform this option only among the same hardware platforms and same firmware versions.

2.1

Gaining Access to the UI The method for establishing access to the UI depends on the connection used. Select the setup that best fits the network environment.

2.1.1

Using Telnet Using a Telnet session to gain access to the UI requires that a remote station have a TCP/IP stack. The remote station can be on the wired or wireless LAN. To access the AP from the workstation: 1. From the DOS prompt, Telnet to the AP using its IP address: Telnet xxx.xxx.xxx.xxx

Spectrum24 AP-4121 Access Point Product Reference Guide

39

Page 50

Configuring the AP

2. At the prompt type the password: Symbol

The password is case-sensitive. 3. Press the ESC key. The AP displays the Main Menu: Symbol Access Point MAIN MENU Show System Summary

AP Installation

Show Interface Statistics

Special Functions

Show Forwarding Counts

Set System Configuration

Show Mobile Units

Set RF Configuration

Show Known APs

Set Access Control List

Show Ethernet Statistics

Set Address Filtering

Show RF Statistics

Set Type Filtering

Show Misc. Statistics

Set SNMP Configuration

Show Event History

Set Event Logging Configuration

Enter Admin Mode

–

If the session is idle (e.g. no input) for the configured time, the session terminates.

–

Press CTRL+D to manually terminate the session.

4. Proceed to section 2.13.1: ”Update Using TFTP” on page 123 to update the AP firmware or HTML file or to section 2.2: ”Navigating the UI” on page 50.

40

Spectrum24 AP-4121 Access Point Product Reference Guide

Page 51

Configuring the AP

2.1.2

Using a Direct Serial Connection The factory-configured AP accepts a dial-up connection between the AP and a modem. A UI connection requires a straight-through cable between the modem and the AP. See section 2.2.3: ”Configuring for Dial-Up to the UI” on page 55. The AP serial port is a DB-9, 9-pin male connector. The serial port allows a UI connection to a configuration PC. Connecting the AP directly to a PC with a 9-pin serial port requires a null modem cable with the following configuration: Assuming the UI and serial port are enabled on the AP: 1. Apply Power to the AP. 2. Attach a null modem serial cable from the AP to the terminal or PC serial port. 3. From the terminal, start the communication program, such as HyperTerminal for windows. 4. Select the correct COM port along with the following parameters. emulation

ANSI baud rate

19200 bps data bits

8 stop bits

1 parity none flow control none

There is no password requirement.

Spectrum24 AP-4121 Access Point Product Reference Guide

41

Page 52

Configuring the AP

5. Press ESC to refresh the display. The AP displays the Main Menu. Symbol Access Point MAIN MENU Show System Summary

AP Installation

Show Interface Statistics

Special Functions

Show Forwarding Counts

Set System Configuration

Show Mobile Units

Set RF Configuration

Show Known APs

Set Access Control List

Show Ethernet Statistics

Set Address Filtering

Show RF Statistics

Set Type Filtering

Show Misc. Statistics

Set SNMP Configuration

Show Event History

Set Event Logging Configuration

Enter Admin Mode

6. Refer to section 2.11.2: ”Updating Using Xmodem” on page 117 to update the AP firmware or HTML file or to section 2.2: ”Navigating the UI” on page 50. 7. Exit the communication program to terminate the session.

2.1.3

Using a Dial-Up Connection A dial-up connection requires a straight-through cable between the modem and the AP. The remote PC requires a modem and a communication program (Microsoft Windows Terminal program). See Appendix B for information on the modems supported by the AP. 1. Set Modem Connected to Yes in the System Configuration screen. 2. Attach a straight-through serial cable from the AP to the modem. 3. Verify the modem connects to the telephone line and has power. Refer to the modem documentation for information on verifying device power. 4. From the remote terminal, start the communication program.

42

Spectrum24 AP-4121 Access Point Product Reference Guide

Page 53

Configuring the AP

5. Select the correct serial port along with the following parameters. emulation

ANSI baud rate

19200 bps data bits

8 stop bits

1 parity none flow control none

6. Dial out to the AP with the correct telephone number. No password is required. 7. Press ESC to refresh the display. The AP displays the Main Menu. Symbol Access Point MAIN MENU Show System Summary

AP Installation

Show Interface Statistics

Special Functions

Show Forwarding Counts

Set System Configuration

Show Mobile Units

Set RF Configuration

Show Known APs

Set Access Control List

Show Ethernet Statistics

Set Address Filtering

Show RF Statistics

Set Type Filtering

Show Misc. Statistics

Set SNMP Configuration

Show Event History

Set Event Logging Configuration

Enter Admin Mode

2.1.4

Using a Web Browser A Web browser is a program used to view Web documents or pages. The browser retrieves the requested page, interprets its text and displays the page on a computer screen. Using a Web browser to gain access to the UI requires the workstation to have a TCP/IP stack and a Web browser. The remote station can be on the wired or wireless LAN.

Spectrum24 AP-4121 Access Point Product Reference Guide

43

Page 54

Configuring the AP

The Web browser (Internet Explorer 4.0 or greater or Netscape) requires JavaScript to gain access to the UI.

Setup Network Web Server Help File Access A network Web server is required to access the Help file from the Access Point Configuration Management System Web pages. This procedure applies to the Microsoft Internet Information Server. The network Web server can be different, if so, some of the procedures differ. Only Network or System Administration personnel should configure the network Web server.

To create the Help file on a network Web server: 1. Create a directory on the network Web server for the AP Web Site Help Files to reside. Often this subdirectory is C:\InetPub\wwwRoot. 2. Copy the *.gif and *.htm files to this directory/folder. The files are found in the x:\firmware\AP\AP Web Site\Help File directory. Where x is the letter assigned to the computer CDROM drive. This installation example is for Windows NT 4.0. 3. From the windows Task Bar select Start. 4. From the drop down menu select Programs. 5. From this menu select Microsoft Internet Server(common).

44

Spectrum24 AP-4121 Access Point Product Reference Guide

Page 55

Configuring the AP

6. From this menu select Internet Service Manager to launch the Internet Information Server Service Manager. 7. Click on the Web service. Ensure the server WWW service is running. 8. Select Properties. 9. Select Service Properties to display the WWW service properties for the server. The WWW Service Properties window opens. 10. Select Directories. 11. Select Add button to open the Directories window. 12. Type the Directory/Folder path of the directory created in step one. 13. Select Virtual Directory. 14. Type a folder alias such as WebHelp and select OK. 15. Check Enable Default Document option. 16. Type S24apHelp.htm as the default document and select Apply. 17. Select OK to exit the window. 18. Test the accessibility to the Help file using a Web browser with a URL similar to: http://xxx.xxx.xxx.xxx/WebHelp Where xxx.xxx.xxx.xxx is IP address of the server.

Accessing Web Browser UI Using a Web browser to gain access to the UI requires the workstation to have a TCP/IP stack and access to a Web browser. The remote station can be on the wired or wireless LAN.

Spectrum24 AP-4121 Access Point Product Reference Guide

45

Page 56

Configuring the AP

To ensure the Web Server option is enabled for the AP: 1. Access the UI using a Serial or Telnet connection. 2. From the Main Menu select System Configuration. 3. Verify the Web Server option on the System Configuration screen is enabled. 4. Select Save-[F1] to save the configuration. To reset the AP for changes to take effect. 1. Select the Special Functions screen. 2. Select Reset AP. 3. Select Yes at the confirmation prompt. To enable Help file access, change the Help URL parameter: 1. Select the Special Functions screen 2. Press F3 to view the Firmware Functions Update Menu. 3. Use the TAB or UP/DOWN ARROW key to select the Alter Filename(s)/HELP URL/TFTP Server.

4. Press ENTER. 5. Use the TAB or DOWN ARROW key to select the .HELP URL field. 6. Type the IP address/URL (Universal Request Locator) of the Web server and the directory/folder of the Web server for the Help file location. http://xxx.xxx.xxx.xxx/WebHelp Where xxx.xxx.xxx.xxx is the IP address of the server. 7. Save the new setting by selecting Save-[F1] option. 8. Select Yes at the confirmation prompt.

46

Spectrum24 AP-4121 Access Point Product Reference Guide

Page 57

Configuring the AP

To access the AP UI using a Web browser from a workstation: 1. From the NCPA properties window set the IP address of the workstation and the subnet mask. The system tells the user to reboot for property changes to take effect. The workstation, in this case, is the workstation or laptop computer running the Web browser. 2. To verify the connection, ping the AP. At the default DOS prompt, type: Ping -t xxx.xxx.xxx.xxx

–

If the ping receives no response, verify that the hardware connections, IP address, gateway address and subnet mask are correct. If correct, contact the site System Administrator for network assistance.

3. Start a Web browser such as Internet Explorer 4.0 or greater, or Netscape 3.0 or greater. Type the IP Address for the associated AP to access the AP using a Web browser: http://xxx.xxx.xxx.xxx

Spectrum24 AP-4121 Access Point Product Reference Guide

47

Page 58

Configuring the AP

4. The Spectrum24 Access Point Configuration Management System main page displays:

The Web pages look different than the Telnet, Direct Serial or Dial-Up Connections, but the contents are the same. Access the different pages using the links located in the left frame. Refer to the online help file for Web page navigation, page contents and parameter use. •

48

To view configuration, function or option changes on the Web page(s) turn off the caching function for the browser being used. –

For Netscape, from the menu bar select Edit, Properties, Advanced and Cache.

–

Select Document in cache is compared to document on network: Every time.

Spectrum24 AP-4121 Access Point Product Reference Guide