Page 183

Hardware Installation

Chapter 4

Hardware Installation AP installation includes connecting the AP to the wired network, AP placement and power up. Installation procedures vary for different environments.

4.1

Precautions Before installing the AP verify the following:

4.2

•

Do not install in wet or dusty areas without additional protection. Contact a Symbol representative for more information.

•

Verify the environment has a temperature range between -20° C to 55° C.

•

If attaching to a wired Ethernet network, keep AP on the same subnet or configure the APs for the Mobile IP (Roaming Across Routers) feature.

Package Contents Check package contents for: •

AP

• power adapter

Contact the Symbol Support Center to report missing or improperly functioning items.

Verify the AP model indicated on the bottom of the unit and packaging.

Spectrum24 AP-4121 Access Point Product Reference Guide

173

Page 184

Hardware Installation

4.3

Requirements The minimum installation requirements for a single-cell, peer-to-peer network: • a power outlet

• an AP antenna.

The AP supports 10/100Base-T unshielded twisted pair (UTP) wired LAN cabling connections. For management user interface access to the serial connector, use a standard null-modem cable for direct serial connection. Order a null-modem cable, part number 61383-00-0, by contacting a Symbol sales representative. Test and use the radio network with an MU.

4.3.1

Network Connection Locate connectors for Ethernet and power on the back of the AP. Ethernet configurations vary according to the environment. Determine the Ethernet wiring to connect the AP, 10/100Base-T UTP or single cell. The site survey determines the number of APs to install and their location.

4.3.2

10/100Base-T UTP Use a 10/100Base-T connection for an AP attached to a wired UTP Ethernet hub. Normal 10/100Base-T limitations apply. To connect 10/100Base-T UTP: 1. Plug the data cable RJ-45 connector into the AP RJ-45 connector. 2. Plug the other end of the data cable into the LAN access port (possibly a hub or wall connection).

174

Spectrum24 AP-4121 Access Point Product Reference Guide

Page 185

3. Add more access points as needed. When connecting the AP-4121 model access point to an Ethernet switch, ensure switch port parameters are set to Half Duplex. Severe performance degradation may result from mis-matched speed or duplex mode. Refer to the rear of the access point for product model information.

4.3.3

Single Cell The single-cell connection option allows a single AP to bridge MUs without a wired network. MUs appear as peers in any Ethernet environment.

4.4

Placing the AP Antenna coverage is analogous to lighting. Users might find an area lit from far away to be not bright enough. An area lit sharply might minimize coverage and creates dark areas. Uniform antenna placement in an area (like even placement of a light bulb) provides even, efficient coverage. Place an AP using the following guidelines: •

Install the AP as high as practical.

•

Orient the AP vertically for best reception.

•

Point the AP antenna downward if attaching the AP to the ceiling.

The AP requires one antenna and can use two. Two antennas provide diversity that can improve performance and signal reception. Attach antennas to ANTENNA connectors on the back of the AP. For a single antenna, use the PRIMARY ANTENNA connector and set the Antenna Diversity setting to Primary Only. This is the left antenna connector when viewed from the front of the unit. It is identified by one vertical bar on the bottom of the unit. The secondary antenna is marked with two vertical bars.

Spectrum24 AP-4121 Access Point Product Reference Guide

175

Page 186

Hardware Installation

The standard antenna performs well in most office environments. Obtain additional or higher-performance antennas from Symbol Technologies, Inc. Contact Symbols representative to order the following models. • standard rubber antenna

• single high-performance antenna

• twin high-performance diversity antennas

• mountable F-plane antenna

If installing two antennas, enable the Antenna Selection in the User Interface found in section 2.3: ”Access Point Installation” on page 56.

4.5

Power Options Power options are as follows: •

Standard 24 volt, 1 amp power supply115/230VAC, 50/60Hz.

Part Number: 50-24000-024

•

US line cord.

Part Number: 23844-00-00

A Symbol BIAS-T system can also be used to combine low-voltage DC with Ethernet data in a single cable connecting to an access point. For information on the BIAS-T system, go to (www.symbol.com) and search for the BIAS-T low power distribution system.

176

Spectrum24 AP-4121 Access Point Product Reference Guide

Page 187

Hardware Installation

4.6

Mounting the AP The AP rests on a flat surface or attaches to a wall, or any hard, flat, stable surface. Use the standard-mounting kit provided with the Spectrum24 AP-4121 Access Point. Choose one of the options based on the environment

4.7

Resting flat

Rests on the four rubber pads on the underside of the AP. Place on a surface clear of debris and away from traffic.

Attaching on the wall

Rests on screws. Orient the AP in a downward position on the wall so the LEDs face the floor.

Connecting the Power Adapter The power adapter connects to the rear of the AP and to a power outlet. 1. Verify the power adapter is correct according to the country. 2. Plug the power adapter cable into the socket at the back of the AP. 3. Plug the adapter into an outlet. The AP is functional when the Status indicator on the front of the AP reaches a consistent flashing and the Wireless LAN Activity indicator begins flickering. This indicates that the AP is ready for MUs to associate with it. The AP works without user intervention after setup. See the AP LED indicators to verify that the unit operates properly.

Spectrum24 AP-4121 Access Point Product Reference Guide

177

Page 188

Hardware Installation

4.8

BIAS-T Low Power Distribution System

The BIAS-T system provides an economical and reliable method for powering access point(s) from a remote location. The BIAS-T system combines lowvoltage DC with Ethernet data in a single cable connecting to an access point. An Ethernet cabling infrastructure is required with the BIAS-T system, but the BIAS-T system single DC and Ethernet data cable creates a modified Ethernet cabling environment. When users purchase a Spectrum24 network they often need to place access points in obscure locations. In the past a dedicated 24-hour, 90-264 VAC power source was required for each Access Point as users connected the access points directly to an existing wired (Ethernet) infrastructure. This often required an electrical contractor to install power drops at each access point location. The BIAS-T conversion feature eliminates the cost of retaining an electrical contractor to install the infrastructure. With the BIAS-T system, centralized power can be provided for numerous access points without a local power supply for each access point.

178

Spectrum24 AP-4121 Access Point Product Reference Guide

Page 189

Hardware Installation

The BIAS-T is a small lightweight unit with a RJ-45 patch cord input connector from the hub on the left-hand side and a RJ-45 patch cord output connector (via the wiring infrastructure) to an access point on the right-hand side. Also on the left-hand side of the BIAS-T is a 24-volt DC connector used to input DC power from the power supply. A separate BIAS-T is required for each access point comprising the Spectrum24 network. The BIAS-T has one LED showing solid green when the unit is receiving power from a standard 24volt power supply.

Bias-T TOP VIEW

Power Input Connector

RJ-45 Connector

RJ-45 Connector

Bias-T

LEFT VIEW

Bias-T

RIGHT VIEW Bi

TVi

(3) d

At the HUB end an Ethernet patch cable connects to the DATA port on the BIAS-T and DC power is connected using a DC power plug. The data signal and DC are combined within the BIAS-T and connected to the CABLE port. An additional patch cable connects the CABLE port to the Ethernet infrastructure. Use an Ethernet 4-pair patch cable to connect the individual access points to the BIAS-T power distribution system.

Spectrum24 AP-4121 Access Point Product Reference Guide

179

Page 190

Hardware Installation

To install a BIAS-T system using a single BIAS-T unit and access point: Steps 1-3 could involve running Ethernet cabling through industrial walls or ceilings. Only a qualified contractor should perform this kind of cabling. 1. Attach one end of a RJ-45 patch cord (5-50 ft.) to the access point. Run the other end of the RJ-45 patch cord through a ceiling or wall into a punch down termination box. 2. Run a CAT-5 Ethernet cable from the punch down termination box to another punch down termination box in the wall or ceiling near the intended location of the BIAS-T unit. 3. Secure a second RJ-45 (5-50 ft.) patch cord from the punch down termination box to the output connector on the right-hand side of the BIAS-T unit. 4. Attach a third RJ-45 patch cord from the input connector on the left-hand side of the BIAS-T unit to the HUB supporting the Spectrum24 component installation.

180

Spectrum24 AP-4121 Access Point Product Reference Guide

Page 191

Hardware Installation

5. Attach the cable supplied with the Symbol Standard 24-volt power supply to the power-input connector on the left-hand side of the BIAS-T unit. 6. Repeat steps 1 through 5 for each additional BIAS-T unit and Spectrum24 access point connected to the HUB as part of the same Spectrum24 component installation.

Spectrum24 AP-4121 Access Point Product Reference Guide

181

Page 192

Hardware Installation

4.9

LED Indicators The top panel LED indicators provide a status display indicating transmission and other activity. The indicators are:

182

Power

Flashing indicates AP initialization. Steady Green during operation.

Wired LAN Activity

Flashing indicates data transfers on wired connection.

Wireless LAN Activity

Flickering indicates beacons and data transfers with MUs.

Spectrum24 AP-4121 Access Point Product Reference Guide

Page 193

Hardware Installation

4.9.1

WLAP mode LED display. When in the WLAP mode the chart below signifies the APs LED indicator status. For the IEEE 802.11 protocol and APs using firmware version 2.70-0X or above only. 1. After power up, system initialization begins: LED

State

Power

On

Wired LAN Activity

Off

Wireless LAN Activity

Blinks slowly

2. When a WLAP begins a full scan: LED

State

Power

On

Wired LAN Activity

Off

Wireless LAN Activity

Blinks slowly

3. When one or more WLAPs are found, but still in full scan state: LED

State

Power

On

Wired LAN Activity

Off

Wireless LAN Activity

Blinks slowly

4. When the WLAP is in functional state, but one or more WLAP connections are not in Forward state: LED

State

Power

Blinks regularly

Wired LAN Activity

Blinks if activity occurs

Wireless LAN Activity

Blinks slowly

Spectrum24 AP-4121 Access Point Product Reference Guide

183

Page 194

Hardware Installation

5. When all WLAP connections are in Forward state: LED

State

Power

On

Wired LAN Activity

Blinks if activity occurs

Wireless LAN Activity

Blinks regularly

Special cases:

184

•

If the WLAP manual BSS_ID is NOT set and no other WLAP is found, the WLAP goes to the functional state.

•

If the WLAP manual BSS_ID is set and the specified WLAP is not found, the WLAP remains in FULL Scan state permanently. The LEDs have the following indicator status permanently: LED

State

Power

On

Wired LAN Activity

Off

Wireless LAN Activity

Blinks slowly

•

If the WLAP manual BSS_ID is set with the broadcast bit ON (i.e. the first Byte is 01) and the specified WLAP is not found, the WLAP tries to associate with another WLAP. If it still cannot find another WLAP, it goes to Functional State.

•

If the Ethernet Timeout in the System Configuration menu is set to 3, the WLAP will keep track of the WLAP Alive BPDU. If the BPDU is missing for WLAP Hello Time seconds, the WLAP state changes to WLAP Lost on Ethernet and the LEDs have the following states: LED

State

Power

On

Wired LAN Activity

Blinks slowly

Wireless LAN Activity

Off

Spectrum24 AP-4121 Access Point Product Reference Guide

Page 195

Hardware Installation

4.10 Troubleshooting Check the following symptoms and their possible causes before contacting the Symbol Support Center.

4.10.1 Ensure wired network is operating Verify AP operation: 1. AP does not power up: – faulty AP power supply

– failed AC supply

–

Electrical Management System (EMS) operating outlet.

2. After the AP resets and hardware is initialized, it performs an SRAM test. If the test passes, the LEDs turn on. If the test fails, the LEDs all turn off and the AP resets. The LEDs turn off sequentially as each test passes. Identify wired network problems: 1. No operation: –

Verify AP configuration through Telnet or UI. Review procedures for Ethernet and serial connection of the AP. Review AP firmware revisions and update procedures.

–

Verify network configuration by ensuring that there are no duplicate IP addresses. Power down the device in question and ping the assigned address of the device. Ensure no other device responds to that address.

2. AP powered on but has no connection to the wired network: –

Check connections for proper wiring.

3. Verify network wiring and topology for proper configuration: –

Check that the cables used have proper pinouts and connectors.

–

Verify router configuration and filtration setting.

–

Verify MU operations.

–

Confirm AP operation.

–

Confirm AP and MU Net_ID (ESS).

Spectrum24 AP-4121 Access Point Product Reference Guide

185

Page 196

Hardware Installation

–

Check that the radio driver loaded properly.

–

Check that the MU PROTOCOL.INI or NET.CFG file is compatible with the network operating system.

4. Slow or erratic performance: –

Check MU and RF communications range.

–

Check antenna, connectors and cabling.

–

Verify that antenna diversity setting for AP is appropriate. If using one antenna, the setting is Primary Only, if using both antennas, the setting is Full Diversity(in this setting the radio receives on the primary or secondary antenna and transmits on the last antenna to receive a signal) or Rx Diversity (in this setting the radio receives on the primary or secondary antenna but transmits on the primary antenna only).

–

Verify network traffic does not exceed 37% of bandwidth.

–

Check to see that the wired network does not exceed 10 broadcast messages per second.

–

Verify wired network topology and configuration.

4.11 Setting Up MUs Refer to the LA-4100 Series PC Card & PCI Adapter Product Reference Guide for installing drivers, client software and testing. Use the default values for the Net_ID (ESS) and other configuration parameters until network connection verification. MUs attach to the network and interact with the AP transparently.

186

Spectrum24 AP-4121 Access Point Product Reference Guide