The Symbol quick reference guide for the Spectrum24 AP-3020/AP-3021 Ethernet access point, which bridges a wired Ethernet LAN and a Spectrum24 frequency-hopping wireless network. It covers site checks, Ethernet and power hookup, antennas, mounting, the status lights, specifications and regulatory limits.
- Device
- Access point bridging wired Ethernet LANs and Spectrum24 wireless networks at 1 and 2 Mbps p. 2
- Radio
- Country dependent, within 2400 MHz to 2500 MHz; 79 hops standard, fewer in some countries; 100mW and 500mW versions p. 2
- Ethernet
- 10Base-T unshielded twisted pair, RJ-45 connector p. 2
- Serial port
- Male DB9 RS-232 port, 19200 bps p. 2
- Power supply
- 50-24000-006, 115/230VAC, 50/60Hz; US line cord 23844-00-00; remote power distribution system AP-PS-11 p. 2
- Antennas
- Needs one antenna and can use two for diversity; a single antenna goes on the PRIMARY ANTENNA connector p. 2
- Antenna options
- Standard rubber, single high performance, twin high performance diversity and mountable F-plane antennas; models ML 2499-AP A1-00, ML 2499-HP A1-00, ML 2499-D V A1-00, ML 2499-PSA1-00 p. 2
- Extension cables
- 25-19371: 6 ft., 2.0 dB, 5% range loss; 25-19371-02: 12 ft., 4.0 dB, 10% range loss p. 2
- Mounting brackets
- Universal wall-mounting bracket ML-2499-APB1-00 and AP-3020 adapter bracket 12-20436-01 p. 2
- Size and weight
- 1.25 in. H x 5.5 in. L x 7.25 in. W; 1 lb (0.454 kg) p. 2
- Temperature
- -20° C to 55° C (-4°F to 131 °F) p. 2
- Range
- Two range figures are listed: open environment over 1000 ft. (303 m) or 500 ft. (152 m); typical office or retail 180 to 250 ft. or 125 to 175 ft. p. 2
- Durability
- Withstands a 30 in. (76 cm) drop to concrete; 10% to 95% humidity p. 2
- Network
- DIX, Ethernet II and IEEE 802.3 frames; 14,400 frames per second filtering and forwarding p. 2
What this manual walks you through
- Checking the site before installing p. 2
- Connecting to a wired Ethernet hub over 10Base-T p. 2
- Placing and attaching one or two antennas p. 2
- Mounting flat or on a wall p. 2
- Connecting the power adapter and confirming the AP is ready p. 2
- Reading the status lights p. 2
- Regulatory limits for Europe and RF exposure p. 1
Good to know
- Antennas mounted externally or near users must stay at least 20 cm from all persons. p. 1
- In Europe the limit is 100mW EIRP; France and outdoor Belgium are restricted to narrower bands, and Italy requires a user license. p. 1
- Install in wet or dusty areas only with extra protection. p. 2
- When attached to a wired Ethernet, keep the AP on the same subnet. p. 2
- Antenna extension cables cost some range. p. 2
Questions this manual answers
What power supply does the Symbol AP-3020 use?
Power supply 50-24000-006 (115/230VAC, 50/60Hz) with US line cord 23844-00-00, or the AP-PS-11 remote power distribution system. p. 2
How fast is the AP-3021 wireless link?
It provides 1 and 2 Mbps data rates on the radio network. p. 2
What does the AP-3020 Status light mean?
One flash per second is normal; steady or irregular flashing means a fault. p. 2
Can the AP-3020 use two antennas?
Yes, it needs one and can use two for diversity; enable Antenna Selection in the user interface when two are fitted. p. 2
What is the range of the AP-3020?
The guide lists over 1000 ft. or 500 ft. in an open environment, and 125 to 250 ft. in a typical office or retail space. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
www.symbol.com
73-20992-01 Revision A
*73-20992-01* Symbol Technologies, Inc. One Symbol Place Holtsville, NY 11742-1300 This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900;5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,068,190; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172; D418,500; D419,548; D423,468; D424,035 Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan); European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713
Patents
Copyright © 2000 by Symbol Technologies, Inc. All rights reserved. No part of this publication may be modified or adapted in any way, for any purposes without permission in writing from Symbol Technologies, Inc. (Symbol). The material in this manual is subject to change without notice. Symbol reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication, estoppel, or otherwise under any Symbol Technologies, Inc., intellectual property rights. An implied license only exists for equipment, circuits And subsystems contained in Symbol products. Symbol, the Symbol logo and Spectrum24 are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged IBM is a registered trademark of International Business Machine Corporation. Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation. Novell and LAN Workplace are registered trademarks of Novell Inc. Toshiba is a trademark of Toshiba Corporation.
Quick Reference Guide
Access Point AP-3020/AP-3021
Copyright
Declaration of Conformity
We, Symbol Technologies Inc. of One Symbol Plaza, Holtsville, NY 11742-1300, USA declare under our sole responsibility that the product Spectrum24, LA-302C, 2Mbps Type II Radio Card without microprocessor To which this product relates, is in conformity with the following standards and/or other normative documents. ETS 300 328 (November 1996) Radio; Wideband 2.4GHz Spread Spectrum ETS 300 826 (November 1997) EMC: 2.4GHz wideband transmission systems EN 60950: 1992 Incl Amdt 1-4, 11 - Safety of Information Technology Equipment We hereby declare that all essential radio test suites have been carried out and that the above named product is in conformity to all the essential requirements of Directive 1999/5/EC. The conformity assessment procedure referred to in Article 10(5) and detailed in Annex IV of Directive 1999/5/EC has been followed with the involvement of the following Notified Body(ies): BABT, Claremont House, 34 Molesey Road, Walton-on-Thames, KT12 4RQ Identification mark: 0168 The equipment also carries the Class 2 equipment identifier The technical documentation relevant to the above equipment can be made available for inspection on application to: Symbol Technologies EMEA, Symbol Place, Winnersh Triangle, Berkshire, RG 41 5TP, UK Dornu Narnor (name)
Senior Director, Regulatory (title) (signature of authorised person)
7 September 2000 (date)
Customer Support
Regulatory Compliance
Symbol RF products are designed to be compliant with the rules and regulations in the locations into which they are sold and will be labeled as required. The majority of Symbol RF devices are type approved and do not require the user to obtain license or authorization before using the equipment. Any changes or modifications to Symbol Technologies equipment not expressly approved by Symbol Technologies could void the user’s authority to operate the equipment.
Radio Frequency Interference Requirements
This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commissions Rules and Regulation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. However, there is no guarantee that interference will not occur in a particular installation If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient or relocate the receiving antenna. Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that which the receiver connected.
" ""
Radio Frequency Interference Requirements - Canada
Symbol Technologies is committed to providing its customers with world-class customer service and technical support. The Symbol Support Center operates as the single point of contact for any technical problem, question or support issue. The Support Center operates all year, 24 hours a day, staffed by full-time professional Technical Specialists. If Symbol cannot solve the problem immediately within its tiered, technical-support center, access to all technical disciplines within Symbol become available for further assistance and support. First response / contact within 24 hours or one business day. Responses by email, fax or telephone.
North American Contacts
Inside North America, contact Symbol at: Symbol Technologies, Inc. One Symbol Plaza, Holtsville, New York 11742-1300 Telephone: 1-516-738-2400/1-800-SCAN 234; Fax: 1-516-738-5990 Symbol Support Center: Telephone: 1-800-653-5350; Fax: (516) 563-5410; Email: support@symbol.com
International Contacts
Outside North America, contact Symbol at: Symbol Technologies Technical Support 12 Oaklands Park; Berkshire, RG41 2FD, United Kingdom Tel: 011-44-118-945-7000 or 1-516-738-2400 ext. 6213
This Class A digital apparatus meets the requirements of the Canadian InterferenceCausing Equipment Regulations. Cet appareil numérique de la Classe A respecte toutes les exigences du Reglement sur le Materiél Brouilleur du Canada. To comply with FCC and Industry Canada exposure requirements, antennas that are mounted externally at remote locations or operating near users at stand-alone desktop or similar configurations must operate with a minimum separation of 20 cm from all persons.
European Economic Area
The European variant is intended for use throughout the European Economic Area, however authorization for use restricted as follows:
" " " "
European standards dictate maximum radiated transmit power of 100mW EIRP and frequency range 2.400 - 2.4835 Ghz. France, the equipment is to be restricted to the 2.4465 - 2.4835 GHz frequency range. Belgium outside, the equipment is to be restricted to the 2.460 - 2.4835 GHz frequency range. Operation in Italy requires a user license.
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Introduction
10Base-T UTP
The Ethernet Access Point (AP) provides a bridge between Ethernet wired LANs and Spectrum24 wireless networks. It provides transparent access between Ethernet wired networks and radio-equipped mobile units (MUs). MUs include all of Symbol Spectrum24 terminals, scanners, third-party devices and other equipment. The AP provides 1 and 2 Mbps data transfer rates on the radio network. For further information on Access Point configuration, refer to the Spectrum24 Access Point AP-3020/AP-3021 Product Reference Guide from the Symbol Technologies Web page: http: www.symbol.com.
Precaution
" ""
Before installing the AP verify the following: The location for the unit is dry and dust free. Install in wet or dusty areas only with additional protection. The environment has a temperature range between -20° C and 55° C If attaching to a wired Ethernet, keep AP on the same subnet.
Use a 10Base-T connection for multiple APs or an AP attached to a wired UTP Ethernet hub. Normal 10Base-T limitations apply. 1. Plug the data cable RJ-45 connector into the AP RJ-45 connector. 2. Plug the other end of the data cable into the LAN access port (possibly a hub or wall connection). 3. Add additional APs as needed.
LED Indicators
The top-panel LED provide a status display indicating transmission, error conditions and other activity. The indicators are:
Requirements
The minimum installation requirements for a single-cell, peer-to-peer network are a power outlet and an antenna. Note: Use and test the radio network with an MU. The AP supports a 10Base-T unshielded twisted pair (UTP) standard.
Power Options
" "
Standard power supply Part Number: 50-24000-006 -115/230VAC, 50/60Hz. US line cord Part Number: 23844-00-00 Remote power distribution system, Part Number: AP-PS-11
- See application note AP-PS-01 located on the Symbol Technologies Web page.
Status
One flash per second indicates normal operation. A steady on/off, or irregular flashing indicates a fault condition.
Serial
Flashing indicates serial port activity.
Wired LAN attached
On indicates a valid 10BaseT Ethernet Connection.
Wired LAN In Use
Flashing indicates data transfers using a wired connection.
Wireless LAN Attached
On indicates an MU is associated with the AP.
Wireless LAN In Use
Flickering indicates beacons and data transfer with MUs.
Attaching the Antenna(s)
Antenna coverage is analogous to lighting. Users might find an area lit from far away not bright enough. An area lit sharply might minimize coverage and create dark areas. Uniform antenna placement in an area (like an even placement of light bulbs) provides even, efficient coverage. Place the antenna using the following guidelines: Install the antenna as high as practical. Orient the antenna vertically for best reception. Point the antenna downward attaching the antenna to the ceiling. The AP requires one antenna and can use two. Two antennas provide diversity that can improve performance and signal reception. 1. Attach antennas to ANTENNA connectors on the back of the AP. For a single antenna, use the PRIMARY ANTENNA connector. 2. Refer to antenna documentation for mounting.
" "
The standard antenna performs well in most office environments. Obtain additional or higher performance antennas from Symbol. Contact a Symbol sales representative to order the following models:
" standard rubber antenna " single high performance antenna " twin high performance diversity antennas " mountable F-plane antenna
ML 2499-AP A1-00 ML 2499-HP A1-00 ML 2499-D V A1-00 ML 2499-PSA1-00
Symbol continues to add antenna options for Spectrum24 devices. Contact a Symbol sales representative for available antenna options. If installing two antennas, enable the Antenna Selection in the User Interface. Refer to Access Point Installation in the Spectrum24 Access Point AP-3020/AP-3021 Product Reference Guide.
Antenna Extension Cables
Symbol offers extension cables for AP antenna. Some range loss occurs when increasing the distance between the antenna and the AP.
ModelLengthLossRange Loss25-193716 ft.2.0 dB5%25-19371-0212 ft.4.0 dB10%
To order extension cables contact a Symbol representative.
Hardware Installation Mounting the AP
The AP rests on a flat surface or attaches to any hard, flat, stable surface. Position the AP at any angle. Use the standard-mounting kit provided. Users can obtain a universal wallmounting bracket (ML-2499-APB1-00) and an AP-3020 adapter bracket (12-20436-01) from Symbol for attaching the AP and antennas to the wall or ceiling. Contact a Symbol sales representative to order. Choose an option based on environment. Resting flat Rests on the four rubber pads on the underside of the AP. Place on a surface clear of debris and away from traffic. Attaching on the wall in any direction. Rests on screws. Orient the AP in any position on the wall.
" "
Specifications
Physical Characteristics: Dimensions: Weight: (w/power supply) Operating Temp: Humidity: Shock: ESD Drop
Radio Characteristics: Frequency Range Frequency Hopping
Connecting the Power Adapter
The power adapter connects to the rear of the AP and to the power outlet. 1. Verify that the power adapter matches the country-of-use adapter. 2. Plug power adapter cable into the socket on the AP back. 3. Plug adapter into outlet. When the Status indicator on the front of the AP flashes consistently and the Wireless LAN Activity indicator begins flickering the AP is functional and ready to associate with MUs. The AP works in a default configuration without user intervention after setup. Refer to Access Point Installation in the Spectrum24 Access Point AP-3020/AP3021 Product Reference Guide for complete installation instructions. Refer to the AP LED indicators to verify proper AP operation.
Radio Data Rate Radio Power Output 1Mbps Range 2 Mbps Range TX Maximum ERP
Network Connection
Locate connectors for Ethernet, antenna and power on the back of the AP.
Primary Antenna 10Base-T
Power Secondary Antenna
Serial Port (Male)
UAP3DRearPh3.cdr
Ethernet configurations vary according to the environment. Determine the Ethernet wiring to connect the AP. 10Base - T UTP or wireless mode single cell. Note: The site survey determines the APs to install and their location.
1.25” H x 5.5” L x 7.25” W (3.18 cm H x 14.97 cm L x 19.69 cm W) 1 lb (0.454 kg) -4°F to 131 °F (-20 °C to 55 °C) 10% to 95% non-conditioning 40 g, 11mS, half- sine meets CE-Mark Withstands up to a 30 in. (76 cm) drop to Concrete with possible surface marring.
Modulation TX Out of Band Emissions
country dependent; within 2400 MHz to 2500 MHz. Hops 79 standard 35 in France 27 in Spain 23 in Japan 20 in Belgium (outdoor) 29 in Mexico Hop Rate configurable Hop Sequences 79 (per IEEE 802.11) 1 and 2 Mbps per channel 100mW and 500mW versions open environment - over 1000 ft. (303 m) typical office or retail environment - between 180 and 250 ft. (54.5 to 75.7 m) open environment - 500 ft. (152 m) typical office or retail environment - between 125 and 175 ft. (38 to 53 m) US: FCC part 15.247 Europe: ETS 300,328 Japan: RCR STD-33 Binary GFSK US: FCC part 15,247, 15205, 15,209 Europe: ETS 300,328 Japan: RCR STD-33
Network Characteristics: Driver Support Ethernet Frame Filtering Packet Rate
Ethernet Connection Serial SNAP
CDI v1.6, NDIS v2.01 DIX, Ethernet II and IEEE 802.3 14,400 frames per second filtering and forwarding 10Base-T (RJ-45) PS/AT serial port - DB9-RS-232, 19200 bps Version 1, MIB-II and Symbol MIB