Page 343

802.11n 12-11

• Extra batteries for the laptop (if available) & charger. • Choose a method for data transfer. Due to the inclusion of MIMO technology in the 802.11n standard, 802.11n system performance can only be measured when data packets are sent from a specific AP to a specific client. LANPlanner provides three options for enforcing data transfers between the test AP and the client. • For local SiteSpy operation: Only one PC is required. Local SiteSpy operation is run from within the AP Performance mode measurement panel of LANPlanner and can be configured based on the instructions provided in the LANPlanner User’s Manual available at http://support.symbol.com/support/product/manuals.do. • For remote SiteSpy operation: Two computers are required, one as the SiteSpy server and one as the SiteSpy client. The SiteSpy server can be run using the SiteSpy application or from within LANPlanner and can be configured based on the instructions provided in the LANPlanner User’s Manual available at http://support.symbol.com/support/product/manuals.do. The SiteSpy client is run from within the AP Performance mode measurement panel of LANPlanner and can be configured based on the instructions provided in the LANPlanner User’s Manual available at http://support.symbol.com/support/product/manuals.do. • For operation in other modes: Any network application can be used (such as a file transfer, VOIP, video streaming, iPerf, etc.) as long as data is consistently transferred between the test AP and the client. • Test connectivity between the server and the client. Common causes of network disconnect include: Improperly assigned IP addresses on the test AP, client, or remote server. A firewall on the test AP, client, or remote server is prohibiting connectivity between the SiteSpy server and client. In such cases, the firewall will need to be either disabled or configured to allow all traffic from the client.

12.9.2 LANPlanner Survey By using a point-and-click measurement method, LANPlanner can obtain measurement data by simply roaming throughout the building environment and clicking on the associated position within the LANPlanner drawing. However, the validity and completeness of the measurement scenarios and the accuracy of measurement results should be guaranteed. The following tasks and activities need to be carefully performed when conducting an 802.11n survey:

Choose an appropriate method for site data collection Single marker and track run measurement modes are available for 802.11n surveys. The specifics of these two measurement methods is outlined in the LANPlanner User’s Manual available at http://support.symbol.com/support/product/manuals.do, however an important distinction needs to be made between their operations during 802.11n surveys. In both modes (when the user clicks to record a measurement), the software records the latest data available from the WLAN card. In single marker mode (if insufficient data is available when the software initially requests measurement data), the software waits up to 1 second to determine if a more reliable estimation of the RF performance can be obtained before recording the data. The 1 second timeout is not available in

Page 344

12-12 Enterprise WLAN Design Guide track run mode since the precise timing of the measurements is required for interpolating the position between the start and end points of the track run mode.

Maximize the reliability of the data collected at each measurement location If using SiteSpy for enforced data transfer, guarantee the connection between the SiteSpy server and the SiteSpy client when taking measurements A disconnect from the SiteSpy server can be determined when: 1. The status of the Network tab is Disconnected. The following shows the Network tab in a disconnected state.

Page 345

802.11n 12-13

2. No associated AP is in the Access Point Information window. If an associated AP was present, a green circle would appear to the left of the MAC address. Click the Connect button in the Network tab to reestablish network connection. If the network connection cannot be reestablished because the receiver has left the coverage area of the test AP, the measurement run should be stopped. Monitor the link information in real-time to ensure data is being transferred from the test AP to the client. This data is available in the Link Info tab within the AP Performance mode’s measurement panel.

In single marker mode, it is best to initiate measurements (by clicking on the measurement location in the drawing) when the Link Info tab is populated with valid data. If Link Info data is always Unknown, check the connection to the SiteSpy server in the Network tab. When link information is not consistently available (valid values are only present ~20% of the time), valid measurement data cannot be always obtained. Even if the client is connected to the SiteSpy server the measurement run should be stopped, and the measurement setup will need troubleshooting to correct the problem. Common causes of this problem include packets being too large. A small packet (64KB) is recommended for 802.11n measurements since it maximizes the number of packets that can be sampled for

Page 346

12-14 Enterprise WLAN Design Guide measurement data (in a short distance, even the largest packet can get 90% of the info). Another common cause is the receiver leaving the coverage area of the test AP. To eliminate these problematic conditions: • Take multiple measurements at each location, especially in single marker mode. Rotate the client to obtain one measurement at each rotation so collected data averages the effects of antenna orientation and body loss. • In single marker mode, maximize accuracy of the marker location by referring to visual cues captured in both the formatted building in software and in the actual environment. Door frames, hallways, and cubicles all serve as excellent visual cues to help maximize measurement location accuracy. • Define the measurement speed. In single marker mode, wait at least 2 seconds between each measurement. In track run mode, walk at a slow pace (~0.8m/s) during the survey.

Perform a complete survey of the 802.11n performance • Take measurements which fully capture the diversity of the RF environment. This includes: NLOS measurements LOS measurements Longer LOS measurements in hallways or canyons (LOS measurements at distances of 10m or more in a hallway). This scenario is particularly important to measure since it represents areas of usually poor MIMO performance and so every effort should be made to measure the full length of a hallway link (when the test AP and client are both in the hallway). Measurement locations that separate the test AP and the client with a diversity of obstructions. For example, the LOS path from the test AP to the client should be obstructed by drywall partitions, cubicles, inventory racks, or any other obstructions which characterize the measurement environment. • Cover enough RSSI range. Every effort should be made to measure the full range of signal strengths from the test AP (RSSI). This will help to obtain a full picture of the test AP performance in both good and bad environments. As an example, a typical range of RSSI values would cover all values from -40dBm to -90dBm. A full range of RSSI values should be gathered for both LOS and NLOS paths. Obviously, LOS paths may not receive RSSI values as low as NLOS paths, but every effort should be made to obtain as full of a RSSI range as possible. A good rule of thumb is to leave the coverage area of the test AP. This usually will guarantee that you have measured the lower end of the RSSI range. • Guarantee the number of the measurements. Take measurements in at least 75 different measurement locations per survey. Balance the measurement number between LOS and NLOS scenarios. A 50-50 distribution is a good method. Take at least 20 measurements per 10dBm RSSI range. Take multiple measurements at each location. A good rule of thumb is to take 3 or 4 measurements per location when rotating the receiver about its azimuth plane to include the effects of orientation and body loss.

Page 347

802.11n 12-15

Organize the measurement results • Use measurement filenames which adequately describe the type of survey conducted. • Save the measurement results (*.wvc file) and the layout with markers locations (*.dwg file). By keeping a separate drawing file which includes all information regarding the test AP placement and configuration it is less likely that the relevant network model for the measured data will be lost. NOTE: Measurement duration is based on the building scale and number of measurements. A typical survey of 100 measurement locations should take approximately 1 hour.

NOTE: Laptop recharging can be problematic. Make sure your laptop is fully charged before starting a measurement survey, and if possible bring extra batteries.

Page 348

12-16 Enterprise WLAN Design Guide

Page 349

Appendix A Customer Support Motorola’s Enterprise Mobility Support Center If you have a problem with your equipment, contact Enterprise Mobility support for your region. Contact information is available by visiting http://www.motorola.com/customersupport and after selecting your region, click on the appropriate link under Support for Business When contacting Enterprise Mobility support, please provide the following information: • Serial number of the unit • Model number or product name • Software type and version number Motorola responds to calls by email, telephone or fax within the time limits set forth in support agreements. If you purchased your Enterprise Mobility business product from a Motorola business partner, contact that business partner for support.