Spec sheet · Starrett
Data Collection Systems
Spec sheet13 pagesPDF 1.7 MB
Starrett catalog pages on data collection systems, including the No. 772A and 772B SPC Plus data collectors and their options.
What this file really is
The old site listed this file as a spec sheet for the Starrett 772. This is the Data Collection Systems section of a Starrett catalog, covering DataSure, the No. 761 multiplexer and SPC software as well as the No. 772 collectors, not a spec sheet for the 772 alone.
Filed under · 1 model
Filed under these models in the old catalog
Summary
What is in it
Catalog pages from Starrett covering its data collection systems for electronic measuring tools. They describe the DataSure wireless system (end nodes, routers and gateway), the No. 772A and 772B SPC Plus data collectors with their components, power supplies, input and output options, the No. 761 data multiplexer, computer interface adaptors and cables, and SPC software such as SPC IV Excel and Shop Floor Pro.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A Starrett catalog section on data collection systems, followed by a distributor's contact page. It covers the 772A and 772B data collectors, the 761 multiplexer, the DataSure wireless system, SPC software, and the cables and modules that link Starrett and other makers' tools. It lets a reader choose a collector, its options and the right tool cable.
- Device
- 772A and 772B: SPC data collectors for electronic gages, used fixed or portable, with keypad and LCD display p. 6
- Gage ports
- 772A: two gage ports; 772B: eight gage ports; ports take modules for Starrett and other suppliers' tools in any combination p. 6
- EDP numbers
- 772A: EDP 65899; 772B: EDP 65900 p. 7
- Power
- Line power or replaceable/rechargeable battery packs; furnished charger for 115/120 Volts/60 Cycle; European and UK chargers 100-240 VAC, 47-63Hz p. 6, 7
- Keys
- Keypad for manual entry; five function keys, two scroll keys, ten custom keys storing up to 16 keystrokes p. 6
- Display and charts
- LCD shows X-Bar, R and S charts and histograms with the optional program card; reads to six decimal places p. 6
- Furnished with
- Power supply charger, carrying strap, P.C.M.C.I.A. data storage card, custom key tab, instruction manual p. 7
- Triggering
- Foot switch or pendant switch inputs; programmable automatic trigger and trigger timer p. 6, 7
- PC connection
- Link 72 software and cable, No. PT99523 / EDP 65906: 3 1/2 inch disk and a cable with 9-pin female connectors on both ends p. 7
- Tool modules
- Module PT61192 (Starrett #3) supplied in the collector; also module PT61285 (Starrett #4) p. 7, 11
- Software
- Data Collection Software and Software Wedge No. 719 / EDP 66490; SPC Plus II software No. 739 / EDP 64955 p. 7, 10
- Other features
- Password capability, traceability with 4 fields, assignable cause option, flashing LED backing up the audible signal p. 6
- 761 Multiplexer
- 761A: PC gage interface supplied with 4 Starrett modules, expandable to 8 gages with the 761B; AC powered p. 8
- DataSure
- DataSure: wireless End Nodes, Routers and a USB or RS232 Gateway on a license-free 916MHz ISM band radio; End Node power CR2450 lithium or CR2477 p. 3, 5
What this sheet walks you through
- Choosing between the 772A and 772B collectors p. 6, 7
- Ordering 772 power, input and output options p. 7
- Linking the 772 to a PC with Link 72 software p. 7
- Matching Starrett tools to cables and modules for the 761 and 772 p. 11
- Cables and modules for other manufacturers' tools p. 12
- Connecting Starrett tools straight to a PC p. 8, 12
- Setting up the 761 multiplexer p. 8
- The DataSure wireless system: End Nodes, Routers and Gateway p. 2, 3, 5
- SPC software: SPC IV Excel, Shop Floor Pro and SPC Plus II p. 9, 10
Good to know
- Charting on the 772 needs the optional program card. p. 6
- DataSure End Nodes or Routers added to an existing system must match the Group Number on the label of the existing parts. p. 5
- DataSure software requires Windows XP Professional with Service Pack 2. p. 4
- The PT61768 computer interface adaptor needs the PT22938 cable. p. 8
- The 761B expansion unit is supplied without modules. p. 8
Questions this sheet answers
How many gages can a Starrett 772 collector take?
The 772A handles up to two gages at once and the 772B up to eight. p. 7
What comes with a Starrett 772 data collector?
A power supply charger, a carrying strap, a P.C.M.C.I.A. data storage card, a custom key tab and an instruction manual. p. 7
How do I get data from a 772 into a PC?
The Link 72 software and cable (No. PT99523) shows the 772 output on a PC screen and lets the PC keyboard control the 772. p. 7
Does the 772 work with Mitutoyo or other brands of gages?
Yes. Its gage ports take modules for other suppliers' tools, which use their standard cables; the list names Mitutoyo, Federal, Chicago Dial Indicator and Brown & Sharpe tools. p. 6, 12
Can the 772 run on batteries?
Yes. It runs on line power or on replaceable/rechargeable battery packs. p. 6
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 2 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file


