For the Siemens UID LDP

Page 21

UID-LDP & UID-DPM Operating Environment •

Operating Temperature:

32°F to 104°F (0°C to 40°C)

•

Storage Temperature:

122°F (50°C) Max

Choosing a PC The UID-LDP and UID-DPM systems require you to supply a PC running Microsoft Windows 2000, Windows XP, or Windows Vista Business with: •

Administrator privileges

•

At least a 2 GHz CPU

•

At least 512M RAM

•

A CD-ROM drive

•

At least 100 Mb of available hard disk space

•

A 10/100 Mb Network (Ethernet) Interface

•

Display capable of displaying at least 1024 by 768 pixels, true colors

Note: In some installations, you will need two network ports: one for your PC and one for the UID-LDP or UID-DPM. For more information, see “Networking to the UID-LDP & UID-DPM” on page 1-10.

Installing Optional Long Feet Spacers For UID-DPM, the feet with standard spacers are installed at the factory to provide the normal stand-off distance of 7/8 inch (22.2 mm). You can lengthen the feet using the optional spacers.

v2.3.1, Dec 2008

•

For labels and data plates with thicknesses up to 1/8 inches (3.2 mm), use the standard spacers.

•

For DPM parts with thicknesses up to 5/8 inches (15.9 mm), replace the standard spacers with the optional long spacers.

Getting Started With Your UID Compliance Verifier

1 Getting Started w/UID Compliance Verifier

UID-LDP & UID-DPM Operating Environment

1-7

Page 22

Chapter

1

Getting Started w/UID Compliance Verifier

•

For DPM parts with thicknesses up to 15/16 inches (23.8 mm), add the optional long spacers to the standard spacers.

Note: You need to make sure that the mark surface of the DPM part is approximately 7/8 inches (22.2 mm) from the bottom of the plate. To install the optional long feet spacer, or to re-install the standard feet, follow Figure 1–5. FIGURE 1–5. Installing the Feet on the UID-DPM (Standard Spacers Shown)

1-8

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 23

Powering Up the UID-LDP & UID-DPM 1.

Connect the power supply to the UID-LDP or UID-DPM, then plug the power supply into a 120V to 230V outlet.

2.

Connect the UID-LDP or UID-DPM to your Ethernet network. See “Networking to the UID-LDP & UID-DPM” on page 1-10 for details. Note: There may be a delay of up to 25 seconds while the verifier sets up to use the default DHCP settings.

Loading the Software Note: To install the UIDChecker™ software, you must be logged on with Administrator privileges. Contact your IT department for help getting Administrator privileges. You do not need to have Administrator privileges to run the UIDChecker™.

Note: You must remove older versions of the software before upgrading. If beta versions of this version software have been installed, the results directory must be moved, renamed, or deleted, as earlier database records are incompatible with the released version. Use the following procedure to install the UIDChecker™ software:

v2.3.1, Dec 2008

1.

Insert the UIDChecker™ Software CD into the CD-ROM drive. In a few moments, the UIDChecker™ software will automatically start the installation program. If this fails, select the CD-ROM drive in Windows Explorer and run the Setup.exe program.

2.

The installation program installs the UIDChecker™ application and the HawkEye 1500 Smart Camera firmware. (You will need to install the firmware to the HawkEye 1500 camera if you are upgrading your UID Compliance verifier). When the Install program is finished, you may have to reboot your PC. Just follow the on-screen instructions.

Getting Started With Your UID Compliance Verifier

1 Getting Started w/UID Compliance Verifier

Powering Up the UID-LDP & UID-DPM

1-9

Page 24

Chapter

1

Getting Started w/UID Compliance Verifier

By default, the installation of the UIDChecker™ application installs all the necessary components in the C:\Program Files\UIDChecker folder. The folder will be created if it doesn’t already exist. You can change the location of the file at installation. All subsequent files, data and images, are located under the main UIDChecker folder on the customer’s hard drive.

Networking to the UID-LDP & UID-DPM The UID-LDP and UID-DPM communicate to the PC using an Ethernet network. There are several ways to connect the UID-LDP/UID-DPM and the PC. Note: This is often the trickiest part of the installation, especially if you are not familiar with Ethernet and connecting equipment to your network. If this is the case, please contact your IT department for help or contact Microscan. 1.

The easiest way to connect your PC and the UID-LDP or UID-DPM is to connect them to an existing local area network (LAN) using the Ethernet cable that is already attached to the verifier. To do this, plug your PC into your LAN, and plug your verifier into your LAN (you will need two Ethernet ports).

FIGURE 1–6. PC & UID-LDP/UID-DPM on Your Ethernet Network

Your Ethernet Network Your PC - Connect to an Ethernet port on your Ethernet network

1-10

UID Verifier - Connect to a second Ethernet port on your Ethernet network

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 25

2.

The second way to connect your PC and the UID-LDP/UID-DPM is to connect them to each other using an Ethernet hub, switch or router (not supplied). You may need your IT department to help you select hardware and set this up.

FIGURE 1–7. Connection Using a Hub, Router or Switch

Hub, Router, or Switch

Your PC - Connect via a hub, router or switch to your to your network 3.

UID Verifier Connect via a hub router or switch to your network

The final way to connect the PC and the reader is to connect them directly to each other on their own private LAN. Do this by adding the supplied cross-link adapter to the reader’s Ethernet cable and plugging it directly into the PC’s network card.

FIGURE 1–8. Direct Connect PC & UID-LDP/UID-DPM using Cross-Link Adapter

Your PC - Connect to the UID Verifier

UID Verifier - Connect to your PC

Cross-Link Adapter (HEENET-XLA)

v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

1-11

1 Getting Started w/UID Compliance Verifier

Networking to the UID-LDP & UID-DPM

Page 26

Chapter

1

Getting Started w/UID Compliance Verifier

DHCP and Static IP Addresses Explained Note: If this is confusing or if you do not understand the terminology, contact your IT department for help. At the Microscan factory, the UID-LDP and UID-DPM are set to use Dynamic Host Communication Protocol (DHCP). In most cases, this means you simply have to plug the UID-LDP/UID-DPM into your network and plug your PC into your network, and the UIDChecker™ software will just find the verifier and work. This works because your network is set up to automatically assign IP addresses to the computers on the network. If there is no automatic assignment of IP addresses (no DHCP), then the PC’s IP address must be set to communicate with the address of the verifier. To do this, you must have Administrator privileges on the PC, and must do the following: 1.

Right click on Network Places and select Properties.

2.

Right click on your Network Card and select Properties.

3.

Scroll down in the Connection Components list.

4.

Select the Internet Protocol item - and select Properties.

5.

Select “Use the following IP address” and enter address 169.254.100.100 and mask 255.255.0.0, as shown in Figure 1–9.

FIGURE 1–9. Entering IP Address and Subnet Mask

6.

1-12

Click OK.

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 27

Upgrading the UIDChecker™ Software from V2.1 To upgrade an existing UID-CK reader running UIDChecker™ V2.1 or earlier to use the new verification type AIM DPM-1-2006 supported in V2.3, you will need to upgrade the hardware first before upgrading the software. To upgrade an existing UID-DPM001 running UIDChecker™ V2.1 or earlier to use the new verification type AIM DPM-1-2006 supported in V2.3, we recommend that you upgrade the hardware first before upgrading the software. If you want to use your existing hardware, you can upgrade only the software (see Appendix D, “Upgrading UID-DPM001 w/UIDChecker Software V2.3,” for more information). If your UIDChecker™ version is older than V2.1, first follow Appendix A, “Upgrading to UIDChecker™ V2.1,” to upgrade your system to running UIDChecker™ V2.1. Then, install the UIDChecker™ V2.3 software as follows: Put the software installation disk into your PC’s CD drive and run Setup. The automated program will prompt you to: 1.

Uninstall the older version of UIDChecker™ software. Just follow the prompts and click OK. Note: It will not delete your results!

2.

Uninstall the older version of HawkEye’s ReadRunner; this is no longer needed in UIDChecker V2.3. Again, just follow the prompts and click OK.

3.

Install the UIDChecker™ software. Just follow the prompts and click OK.

Before using the UIDChecker™ software, you need to upgrade the firmware on the UID reader unit: 1.

From the Start Menu, select Programs > UIDChecker > Utilities > Hawkeye Flasher. The HawkEye Flasher dialog box is displayed, as shown in Figure 1–10.

v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

1-13

1 Getting Started w/UID Compliance Verifier

Upgrading the UIDChecker™ Software from V2.1

Page 28

Chapter

1

Getting Started w/UID Compliance Verifier

FIGURE 1–10. Upgrade the HawkEye™ Flasher Dialog Box

2.

3.

In the Camera drop down list, select your UID Verifier and make sure you enable (check) all the check boxes for: –

Load VxWorks Kernel

–

Load Registry File

–

Load Bootloader.

Click Update!

When “Done” appears at the bottom of the terminal display, the process is complete and you can now start the UIDChecker™ software.

1-14

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 29

Lighting for the UID-LDP & UID-DPM Both the UID-LDP and UID-DPM support AIM DPM-1-2006 fully compliant lighting options. The UID-LDP uses the diffuse perpendicular lighting (90) for label and data plate applications. The UID-DPM uses the multifunction light that supports all light configurations required by MIL-STD-130M/Change 1 and MIL-STD-130N, as shown in Figure 1–11. In both UID-LDP and UID-DPM, the verification can be triggered from a hardware trigger button and the Read UID Mark software button on the UIDChecker™ GUI. FIGURE 1–11. Multifunction Light

For all verification types except AIM-DPM-1-2006, only diffuse perpendicular lighting (90) is supported in UID-DPM.

v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

1-15

1 Getting Started w/UID Compliance Verifier

Lighting for the UID-LDP & UID-DPM

Page 30

Chapter

1

Getting Started w/UID Compliance Verifier

Light Configurations The multifunction light in UID-DPM supports all the light configurations specified in the AIM DPM-1-2006: •

Diffuse perpendicular (on-axis/bright field) (90), A flat diffusing material is oriented such that the plane of the material is parallel to the plane of the symbol area. The symbol is uniformly illuminated with diffuse light incident at 90 ±15° relative to the optical axis to the plane of the symbol.

90° (+/-15)

•

Diffuse off-axis (D), A diffusely reflecting dome is illuminated from below so that the reflected light falls non-directionally on the part and does not cast defined shadows. This is commonly used for reading curved parts.

•

Low angle, four direction (30Q), Light is aimed at the part at an angle of 30 ±3° from the plane of the surface of the symbol from four sides such that the lines describing the center of the beams from opposing pairs of lights are co-planar and the planes at right angles to each other. One lighting plane is aligned to be parallel to the line formed by a horizontal edge of the image sensor to within ±5°. The lighting illuminates the entire symbol area with uniform energy.

30° (+/-3) from all 4 sides (North, East, South, West)

•

Low angle, two direction (30T), Light is aimed at the part at an angle of 30 ±3° from two sides. The light may be incident from either of the two possible orientations with respect to the symbol. The lighting plane is aligned to be parallel to the line formed by one edge of the image sensor to within ±5°. The lighting illuminates the entire symbol area with uniform energy.

30° (+/-3) from 2 sides (North/South or East/West)

1-16

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008