The text of a manual · part 15 of 15
Getting Started With Your UID Compliance Verifier, pages 141 to 148
Pages 141 to 148 of 148
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Siemens UID LDP
Page 141
G Certification & Specifications
APPENDIX G
CE Compliance The UID-LDP and UID-DPM have been certified to conform to the requirements of Council Directives 2004/108/EC, 73/23/EEC, and 93/68/EEC to comply with the following European Standards: EN61326:1997 A3:2003 Class A
•
EN61010-1:2001-02
•
EN60825-1:1993 A2 2001-01
•
EM61000-6-2:2001
•
EM61000-6-4:2001
G
This is a Class A product; in a domestic environment, this product may cause radio interference, in which case, the user may be required to make adequate measures. All Microscan products bearing the CE mark have been declared to be in conformance with the applicable EEC Council Directives. However, certain factory installed options or customer requested modifications may compromise electromagnetic compatibility and prohibit use of the CE mark. Note that the use of interconnect cables that are not properly grounded and shielded may affect CE compliance.
v2.3.1, Dec 2008
Getting Started With Your UID Compliance Verifier
G-1
Certification & Specifications
•
Page 142
Appendix
G
Certification & Specifications
FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case, you will be required to correct the interference at your own expense. Changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.
FDA Statement This equipment complies with: US21 CFR Subchapter J Part 1040.10 IEC 60825-1:1993 Amendment 2 2001-01
Caution The UID-LDP can be set to use targeting lasers. If the targeting lasers are activated, do not stare into the beams. The UID-LDP’s targeting lasers have been rated as Class II lasers by IEC 60825-1. Warning DO NOT LOOK DIRECTLY AT THE BEAMS OF THE LASER!
G-2
Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008
Page 143
Specifications
Specifications UID-LDP Physical Characteristics Dimensions:
13” L x 10” W x 11.6” H
Power Requirements:
AC Adapter 100-250 VAC, 0.5A 50/60 Hz input, 24V at 500 mA output
Illumination:
Embedded Class 1 LED Red LED: 640 nm
Targeting Lasers:
Class II
Weight:
17.2 lb (7.5 kg)
(33.0 cm L x 25.4 cm W x 29.4 cm H)
Performance Characteristics Ethernet for normal operation, RS-232 baud rates 115.2 Kbps for debugging
Field of View:
1.0” x 0.75” (25.4 mm x 19 mm)
Depth of Field:
0.125” (3.175 mm)
Minimum Element Size:
0.0075” (0.19 mm)
Optical Resolution:
660 x 494 Pixels
Light Configurations:
90
Programming:
Windows 2000 / XP / Vista Business
Decode Capability:
Data Matrix, ECC200
User Environment v2.3.1, Dec 2008
Operating Temperature:
32° F to 104° F (0° C to 40° C)
Storage Temperature:
122° F (50° C) Max
Getting Started With Your UID Compliance Verifier
G Certification & Specifications
Interfaces:
G-3
Page 144
Appendix
G
Certification & Specifications
UID-DPM Physical Characteristics Dimensions:
6.7” L x 6.1” W x 8.3” H (17.0 cm L x 15.5 cm W x 21.1 cm H)
Power Requirements:
AC Adapter 100-240 VAC, 1.6A 50/60 Hz input, 24V at 1.5A output
Illumination:
Embedded Class 1 LED Red LED: 640 nm
Weight:
5.95 lb (2.7 kg)
Performance Characteristics Interfaces:
Ethernet for normal operation, RS-232 baud rates 115.2 Kbps for debugging
Field of View:
1.19” x 0.86” (30.2 mm x 21.8 mm)
Depth of Field:
Up to 0.125” (3.175 mm)
Minimum Element Size:
0.0075” (0.19 mm)
Optical Resolution:
660 x 494 Pixels
Light Configurations:
90, D, 45Q, 30Q, 30T (North/South, East/West), 30S (North, East, South, West)
Programming:
Windows 2000 / XP / Vista Business
Decode Capability:
Data Matrix, ECC200
User Environment
G-4
Operating Temperature:
32° F to 104° F (0° C to 40° C)
Storage Temperature:
122° F (50° C) Max
Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008
Page 145
Index default 3-17 delete result 3-32 result(s) 3-34 learn photometry 3-17 live video 2-7, 2-9, 3-7, B-1, B-4 move 3-36 next result 3-32 normalize D-11 previous result 3-32 print result 3-9, 3-32, 3-34 read 3-8
A
ADO Components error messages 3-25 fixing error E-1 Allow Multiple Selection 3-34 Analyzing Results 4-1 UID compliance check 4-1 Apply Manual Photometry Values Button 3-17 Archive tab 3-34 to 3-35 Assembling Lights D-3 Attaching camera D-2 lights to camera D-4 Automatically Save the Result with Each Read 3-23 B
Back to Summary Button 3-30 Buttons apply manual photometry values 3-17 back to summary 3-30 cancel read and rotate B-4 clear log 3-6 log view 3-27 configure camera through serial port 3-11 connect via serial 3-12 copy 3-36 v2.3.1, Dec 2008 and rotate 3-8, 3-21, B-1, B-2 uid mark 3-8 save result 3-9 show summary results 3-32 start search 3-34 turn laser off 3-13 on 3-13 view result 3-9 C
Calibrate 3-13, 3-15 Calibration reflectance 2-3, D-12 testing 2-5 Camera attaching to uid-dpm stand D-2 Cancel Read And Rotate Button B-4 Cell Size Restrictions variance to override 3-25 Certification G-1 Change Results Path 3-27 Clear log button 3-6 log view button 3-27
Getting Started With Your UID Compliance Verifier
Index-1
Page 146
Index
Company Logo specifying your 3-21 Components 1-6 Configurations for the multifunction light 1-16 Configure Camera Through Serial Port Button 3-11 Configuring the Verifier D-9 Connect via Serial Button 3-12 Containing Text 3-34 Control the Lighting 1-17 Copy Button 3-36 Customer Fields defining 3-21 D
Data File Formats uidchecker software F-1 Data Matrix cell size 4-11 quality verification standard 4-11 Database mdb 3-23 table layout 3-24 Default Button 3-17 Define Customer Fields 3-21 Delete result button 3-32 result(s) button 3-34 DHCP Explained 1-12 Diffuse off-axis lighting 1-16 perpendicular lighting 1-16 E
ECC 200 4-11 Error Messages ADO components 3-25 validation 3-37 verification 3-39 Exit 3-10 Exposure 3-16 F
F8 hotkey to read a mark 3-8 File menu 3-10
Index-2 naming scheme 3-1 Files redirect output 3-27 Find Reader Menu Item 3-10 First Time Startup 2-1 FOV uid-dpm 1-3 uid-ldp 1-2 H
HawkEye Sensor Lighting Normalization D-10 I
Images store with results 3-23 Indicators light 3-4 Installing Long Feet Spacers 1-7 L
Layout of the Database Table 3-24 Learn Photometry Button 3-17 Lenses preparing D-3 Lighting 1-15, 3-16 configurations 1-16 control 1-17 diffuse off-axis 1-16 perpendicular 1-16 indicators 3-4 low angle four direction 1-16 one direction 1-17 two direction 1-16 medium angle four direction 1-17 Lights assembling D-3 attaching to camera D-4 Live 3-7 Live Video Button 1-17, 2-6, 2-7, 2-9, 3-7, B-1, B-4
Loading Software 1-9 Long Feet Spacers installing 1-7 Look In 3-34
Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008
Page 147
Index
Low Angle four direction lighting 1-16 one direction lighting 1-17 two direction lighting 1-16
Powering Up 1-9 Previous Result Button 3-32 Print Result Button 3-9, 3-32, 3-34
M
Read and rotate button 3-8, 3-21, B-1, B-2
Mark Quality understanding 4-11 MDB database 3-23 Measurements rotational consistency of B-1 Medium Angle Four Direction Lighting 1-17 Menus file 3-10 reader 3-10 Mode secured 3-2 Move Button 3-36 N
Network setting up D-9 Networking to the Reader 1-10 New Folder Name 3-36 Next Result Button 3-32 Normalization sensor lighting D-10 NORMALIZE Button D-11 O
Operating Temperature 1-7 Operation testing 2-8 Output Files redirect 3-27 Overview uidchecker buttons 3-7 user interface 3-2 P
PC requirements 1-7 Portable Operation uid-dpm 1-5 Positioning Data Matrix for Verification 1-17 v2.3.1, Dec 2008
R when it appears 3-21 button 3-8 menu turn laser off 3-13 uid mark button 3-8 Reader Menu 3-10 calibrate 3-13 find reader 3-10 Redirect Output Files 3-27 Reflectance Calibration 2-3, D-12 Requirements pc 1-7 Result List Box 3-34 Results analyzing 4-1 automatically save with each read 3-23 data file 4-6 path changing 3-27 setup 3-22 stored in mbd database 3-23 view 3-28 Rotational Consistency of Measurements B-1 S
Save result button 3-9 uid read result 3-23 Scheme file naming 3-1 Search Tab 3-32 Secured Mode 3-2 Setting Up network D-9 uid-dpm stand C-1 Setup results 3-22 Show summary results button 3-32
Getting Started With Your UID Compliance Verifier
Index-3
Page 148
Index uid details above image 3-23 verification details in on-screen results view 3-23 Software loading 1-9 upgrading D-9 Specifications G-1 Standards 3-36 Start Search Button 3-34 Startup 2-3 first time 2-1 Static IP Explained 1-12 Storage Temperature 1-7 Store images with results 3-23 results in mbd database 3-23 Summary Report B-6 T
Tabs archive 3-34 search 3-32 view 3-30 Testing calibration 2-5 operation 2-8 the uid compliance verifier 2-3 Triggers 1-18 Turn Laser off button 3-13 on button 3-13 U upgrading A-1 user interface overview 3-2
UID-DPM field of view 1-3 portable operation 1-5 setting up stand C-1 UID-LDP Field of View 1-2 Understanding Mark Quality 4-11 Upgrading from a previous version 1-13 software D-9 uidchecker A-1 V
Variance to Override Cell Size Restrictions 3-25
Verification details show in on-screen results view 3-23 positioning data matrix 1-17 type 3-18 Verifier configuring D-9 Verifier Setting recommended 25mm lens D-5 35mm lens D-7
View result button 3-9 results 3-28 tab 3-30 W
UID compliance check analyzing results 4-1 compliance verifier testing 2-3
Windows 2000 1-7 Vista Business 1-7 xp 1-7 details show above image 3-23 graphical display details 3-3 read details 3-3 results data file 4-6 UIDChecker buttons overview 3-7 data file formats F-1
Index-4
Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008