Page 131

Version 2.0 UIDDataLog.Dat File Format

UID Mark Reading results using perhaps a database scheme will be able to use this log file. Each saved result places a single line of data into the cumulative log file. The data is comma delimited in the following order:

v2.3.1, Dec 2008

–

Path and Name of Image, if image saving is enabled Or Result Number and “:No Image Saved”, if image saving is disabled

–

Month, Day, Year and Time of Result (e.g., April 20 2005 13:24:34”)

–

Software Version (e.g., “2.0.0”)

–

Last Calibration Date Month. Day, Year and Time (e.g., “Calibrated Since Restart - Last: UNKNOWN” or “Calibrated Since Restart - Last: Not Calibrated Since Restart” or “Calibrated Since Restart - Last: April 19 2005 13:24:34”)

Data File Formats for UIDChecker Software

F

–

The string “UII:” followed by the decoded UID string (e.g., “UII: UN077991289420243510936”) Or The string “UII: Not a valid UID Data Matrix” if the mark is invalid

–

“PASS”, if UID Compliant Or “FAIL”, if not UID Compliant

–

“FORMAT INVALID”, if raw data is not a UII format string Or UII Construct (e.g., “# 1”), if raw data is a UII format string

–

“RAW DATA:” followed by raw data, if raw data is not a UII format string Or If raw data is a UII format string: “Data Qualifier” followed by semantic code (e.g., “Data Qualifier: Data Identifier (DI)”) “Data Element 1:” followed by first data element (e.g., “Data Element 1: 12V077991289”) “Data Element 2:” followed by second data element “Data Element 3:” followed by third data element “Data Element 4:” followed by fourth data element

Getting Started With Your UID Compliance Verifier

F-5

Page 132

Appendix

F

Data File Formats for UIDChecker Software

“Data Element 5:” followed by fifth data element “Data Element 6:” followed by sixth data element –

The Verification Standard selected dictates the verification output reported. Use Table F–1 through Table F–5 as reference; use ONE verification standard in your data interpretation.

TABLE F–1. ISO/IEC 16022 Option

“ISO/IEC 16022" “Overall Grade:” followed by the currently displayed overall grade value (e.g., “A” or “B” or “C” or “D” or “F”) “Contrast Grade:” followed by the currently displayed contrast grade value (e.g., “A” or “B” or “C” or “D” or “F”) and its specific value (e.g., “Value = ##%” or “UN_Cal” or “SELF_Cal” or “REFL_Cal” or “???”) “Axial Non-Uniformity Grade:” followed by the current grade value (e.g., “A” or “B” or “C” or “D” or “F”) and its value (e.g., “Value = #.##”) “Print Growth Grade:” followed by the currently displayed print growth grade value (e.g., “A” or “B” or “C” or “D” or “F”) and its X and Y values (e.g., “X / Y = ##% / ##%”) “Unused Error Correction Grade:” followed by the current unused error correction grade value (e.g., “A” or “B” or “C” or “D” or “F”) and its value (e.g., “Value = #.##”) “Size: Height / Width =” followed by the current height and width and the units (e.g., “## / ## PIXELS” or “INCHES” or “???”) “ECC Level:” followed by the current ECC level (e.g., “ECC200” or “ECC140” or “ECC100” or “ECC080” or “ECC050” or “ECC000” or “ECC250” or “???”)

TABLE F–2. ISO/IEC 15415 Option

“ISO/IEC 15415" “Overall Grade:” followed by the currently displayed overall grade value (e.g., “A” or “B” or “C” or “D” or “F”) “Contrast Grade:” followed by the currently displayed contrast grade value (e.g., “A” or “B” or “C” or “D” or “F”) and its specific value (e.g., “Value = ##%” or “UN_Cal” or “SELF_Cal” or “REFL_Cal” or “???”) “Axial Non-Uniformity Grade:” followed by the current grade value (e.g. “A” or “B” or “C” or “D” or “F”) and its value (e.g., “Value = #.##”) “Grid Non-Uniformity Grade:” followed by the current grade value (e.g. “A” or “B” or “C” or “D” or “F”) and its value (e.g., “Value = #.##”)

F-6

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 133

Version 2.0 UIDDataLog.Dat File Format

TABLE F–2. ISO/IEC 15415 Option (continued)

“ISO/IEC 15415" “Unused Error Correction Grade:” followed by the current unused error correction grade value (e.g. “A” or “B” or “C” or “D” or “F”) and its value (e.g., “Value = #.##”) “Fixed Pattern Damage Grade:” followed by the current unused error correction grade value (e.g. “A” or “B” or “C” or “D” or “F”) “Modulation Grade:” followed by the current unused error correction grade value (e.g. “A” or “B” or “C” or “D” or “F”) “Reference Decode Grade:” followed by the current unused error correction grade value (e.g. “A” or “B” or “C” or “D” or “F”) “Print Growth Grade:” followed by the currently displayed print growth grade value (e.g. “A” or “B” or “C” or “D” or “F”) and its X and Y values (e.g., “X / Y = ##% / ##%”)

F Data File Formats for UIDChecker Software

“Cell Size:” followed by the current cell size and the units (e.g., “## / ## PIXELS” or “INCHES” or “???”) “Size: Height / Width =” followed by the current height and width and the units (e.g., “## / ## PIXELS” or “INCHES” or “???”) “ECC Level:” followed by the current ECC level (e.g., “ECC200” or “ECC140” or “ECC100” or “ECC080” or “ECC050” or “ECC000” or “ECC250” or “???”) “20x Clear Space:” followed by True or False

TABLE F–3. Dot Peen Option

“AS9132 Dot Peen” “Module Fill:” followed by the X and Y values (e.g., “X / Y = ##% / ##%”) “Nominal Module Size:” followed by Pass or Fail (e.g., “P” or “F”) and the value and units (e.g., “Value = ##” and “PIXELS” or “INCHES” or “???”) “Dot Size Offset:” followed by Pass or Fail (e.g., “P” or “F”) and the value (e.g., “Value = ##”) “Dot Center Offset:” followed by Pass or Fail (e.g., “P” or “F”) and the value (e.g., “Value = ##”)

v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

F-7

Page 134

Appendix

F

Data File Formats for UIDChecker Software

TABLE F–3. Dot Peen Option

“AS9132 Dot Peen” “Angle of Distortion:” followed by Pass or Fail (e.g., “P” or “F”) and the value (e.g., “Value = ##”) degrees “Matrix Size:” followed by Pass or Fail (e.g., “P” or “F”) and followed by COMMA (e.g., “,”) followed by “< 1.000 INCHES” or “> 1.000 INCHES” “Size: Height / Width =” followed by the current height and width and the units (e.g., “## / ## PIXELS” or “INCHES” or “???”) “ECC Level:” followed by the current ECC level (e.g., “ECC200” or “ECC140” or “ECC100” or “ECC080” or “ECC050” or “ECC000” or “ECC250: or “???”)

TABLE F–4. AS9132 Option

“AS9132 Electrochemical Etching” “Module Fill:” followed by the X and Y values (e.g., “X / Y = ##% / ##%”) “Contrast:” followed by Pass or Fail (e.g., “P” or “F”) and the contrast value (e.g., “Value = ## %”) and the qualifier (e.g., “UN_Cal” or “SELF_Cal” or “REFL_Cal” or “???”) “Angle of Distortion:” followed by Pass or Fail (e.g., “P” or “F”) and the value (e.g., “Value = ##”) degrees “Matrix Size:” followed by Pass or Fail (e.g., “P” or “F”) and followed by COMMA (e.g., “,”) followed by “< 1.000 INCHES” or “> 1.000 INCHES” “Cell Size:” followed by the current cell size and the units (e.g., “## / ## PIXELS” or “INCHES” or “???”) “Size: Height / Width =” followed by the current height and width and the units (e.g., “## / ## PIXELS” or “INCHES” or “???”) “ECC Level:” followed by the current ECC level (e.g., “ECC200” or “ECC140” or “ECC100” or “ECC080” or “ECC050” or “ECC000” or “ECC250” or “???”)

F-8

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 135

Version 2.0 UIDDataLog.Dat File Format

TABLE F–5. AS9132 Laser Option

“AS9132 Laser” “Module Fill:” followed by the X and Y values (e.g., “X / Y = ##% / ##%”) “Contrast:” followed by Pass or Fail (e.g., “P” or “F”) and the contrast value (e.g., “Value = ## “%”) and the qualifier (e.g., “UN_Cal” or “SELF_Cal” or “REFL_Cal” or “???”) “Angle of Distortion:” followed by Pass or Fail (e.g., “P” or “F”) and the value (e.g., “Value = ##”) degrees “Matrix Size:” followed by Pass or Fail (e.g., “P” or “F”) and followed by COMMA (e.g., “,”) followed by “< 1.000 INCHES” or “> 1.000 INCHES” “Size: Height / Width =” followed by the current height and width and the units (e.g., “## / ## PIXELS” or “INCHES” or “???”)

v2.3.1, Dec 2008

–

“Exposure:” and the exposure value

–

“Gain:” and the gain value

–

“Aperture:” and the current aperture value (e.g., AUTO or 4 or 5 or 6 or 7 or 8 or 9 or 10 or 11 or 12 or 13 or 14 or 15 or 16 or 17 or 18 or 19 or 20)

–

“Call Target Contrast:” and the Contrast% (e.g., ##%)

–

“Calibrated since Startup:” and the state (e.g., True or False)

–

“Pixels/(0.1)inch:” and the value

–

“Min/Max Raw Contrast Values:” and the values (e.g., ## / ##)

–

User defined Field 1

–

User defined Field 2

–

User defined Field 3

–

User defined Field 4

–

User defined Field 5

Getting Started With Your UID Compliance Verifier

F-9

Data File Formats for UIDChecker Software

F

“ECC Level:” followed by the current ECC level (e.g., “ECC200” or “ECC140” or “ECC100” or “ECC080” or “ECC050” or “ECC000” or “ECC250” or “???”)

Page 136

Appendix

F

Data File Formats for UIDChecker Software

–

Customer Graphics (e.g., “Logo:” and the Path to the Customer Logo file)

Version 2.1 UIDDataLog.csv File Format The following information is a detailed listing of the comma-delimited contents for a version 2.1 data file. Using this description, you should be able to transfer the data into your local Excel program or a database. Due to the complexity of parsing rules for the results as presented in the commadelimited results file, results are now provided in the same alphabetical order as in the MDB database record and each field is prefixed with a tag name in the form “<tag name>”, to make parsing easier. All fields are always written, even if empty. Note: The “Store Results in MDB database” option must be selected to generate a comma-delimited file output as the fields in the comma-delimited file are taken from the database record. This also has the advantage of providing the value without needing to parse it from a text string. <20xClearSpace>,FALSE,<Angle>,68,<AngleOfDistortionGrade>,,<AngleOfDistortionValue>,,<A perture>,5,…

Recording to an MDB database may be enabled through the Results Setup dialog by selecting the Store Results in MDB database and CSV file option. This setting is saved in the registry for the user so that it is remembered the next time UIDChecker™ is started. The first time a reading is taken after enabling the database, the dialogs displayed in Figure F–1 and Figure F–2 are displayed to provide positive feedback that the database was created and the table within the database was created. FIGURE F–1. MDB Database Startup Sequence

F-10

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 137

Version 2.1 DataBase Table Layout

FIGURE F–2. MDB Database Startup Sequence Continued

Version 2.1 DataBase Table Layout

The database table layout is as follows: TABLE F–6. Database Table Layout v2.3.1, Dec 2008

Variable

Size,

20xClearSpace

VarChar(32),

Angle int,

AngleOfDistortionGrade

VarChar(4),

AngleOfDistortionValue int,

Aperture

VarChar(8),

AxialNonUniformityGrade

VarChar(4),

AxialNonUniformityValue

Double,

Calibrated

VarChar(64),

CalibratedSinceStartup

VarChar(64),

CalTargetContrast int,

CellSizeError

VarChar(16),

CellSizeGrade

VarChar(4),

CellSizeValue

Double,

CellUnitReportString

VarChar(8),

Construct

VarChar(32),

Getting Started With Your UID Compliance Verifier

F-11

F Data File Formats for UIDChecker Software

Note: This database is fully described in “Store Results in MDB Database and CSV File” starting on page 3-23. Please refer to this section for implementation details.

Page 138

Appendix

F

Data File Formats for UIDChecker Software

TABLE F–6. Database Table Layout (continued)

F-12

Variable

Size,

ContrastGrade

VarChar(4),

ContrastReportString

VarChar(32),

ContrastValue int,

CustomerFields1

VarChar(132),

CustomerFields2

VarChar(132),

CustomerFields3

VarChar(132),

CustomerFields4

VarChar(132),

CustomerFields5

VarChar(132),

DataElement1

VarChar(64),

DataElement2

VarChar(64),

DataElement3

VarChar(64),

DataElement4

VarChar(64),

DataElement5

VarChar(64),

DataElement6

VarChar(64),

DataQualifier

VarChar(64),

DotCenterOffsetGrade

VarChar(4),

DotCenterOffsetValue int,

DotSizeOffsetGrade

VarChar(4),

DotSizeOffsetValue int,

ECCLevel

VarChar(8),

Exposure int,

FixedPatternDamageGrade

VarChar(4),

Gain int,

GridNonUniformityGrade

VarChar(4),

GridNonUniformityValue

Double,

HTMLFileName

VarChar(255),

ImgFileName

VarChar(255),

LastUIDString

VarChar(128),

Logo

VarChar(255),

MatrixHeightValue

Double,

MatrixSizeError

VarChar(16),

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 139

Version 2.1 DataBase Table Layout

TABLE F–6. Database Table Layout (continued)

v2.3.1, Dec 2008

Size,

MatrixSizeGrade

VarChar(4),

MatrixWidthValue

Double,

MaxRawContrastValue int,

MinRawContrastValue int,

ModulationGrade

VarChar(4),

ModuleFillGrade

VarChar(4),

ModuleFillXValue int,

ModuleFillYValue int,

NominalModuleSizeGrade

VarChar(4),

NominalModuleSizeValue

Double,

OverrideCellSize

VarChar(8),

OvalityGrade

VarChar(4),

OvalityValue int,

OverallGrade

VarChar(4),

PixelsPerInch int,

PrintGrowthGrade

VarChar(4),

PrintGrowthXValue int,

PrintGrowthYValue int,

RawData

VarChar(255),

ReaderName

VarChar(32),

ReferenceDecodeGrade

VarChar(4),

SequenceNumber

VarChar(12),

SoftwareRev

VarChar(8),

TimeofLastResult date,

UnusedErrorCorrectionGrade

VarChar(4),

UnusedErrorCorrectionValue

Double,

ValidAndVerifPass

VarChar(8),

ValidateFailure

VarChar(128),

ValidISO15434Pass

VarChar(8),

ValidUIDPass

VarChar(8),

Getting Started With Your UID Compliance Verifier

F Data File Formats for UIDChecker Software

Variable

F-13

Page 140

Appendix

F

Data File Formats for UIDChecker Software

TABLE F–6. Database Table Layout (continued)

Variable

Size,

VerificationPass

VarChar(8),

VerificationType

VarChar(32),

VerifyFailure

VarChar(128),

VerifyReadPass

VarChar(8),

Version 2.2 DataBase Table Layout The Version 2.2 database table layout is identical to the Version 2.3 database table layout except for the following: TABLE F–7. Database Table Layout Differences Between V2.3 & V2.2

F-14

V2.3

V2.2

AssociatedCpnLbnString

AssociatedPartNumberString

EditUIIforCpnLbn

EditUIIforPartNumber

EnableCpnLbnSupport

EnablePNRSupport

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008