The text of a manual · part 12 of 15
Getting Started With Your UID Compliance Verifier, pages 111 to 120
Pages 111 to 120 of 148
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Siemens UID LDP
Page 111
D Upgrading UID-DPM001 w/UIDChecker Software V2.3
APPENDIX D
Before you upgrade your UID DPM Compliance Kit (UID-DPM001), make sure you have the following parts.
v2.3.1, Dec 2008
1.
HawkEye 1510 camera with serial cable (FIS-HE15-0CS0)
2.
AC power cable for camera (P/N HEPS-1500)
3.
DOAL-50 V2, R(660) LED-D
4.
AC power cable for light (P/N CPS-12 )
5.
DOAL-50 mounting hardware HELTMA-4L (98-LG17-0XX0)
6.
C-mount lens 25mm (P/N 928-0057-4) or 35mm (P/N 928-0057-5)
7.
Extension ring (P/N C0206)
8.
UID stand (98-UA10-0ST0)
9.
Ethernet cable (P/N HEENET-007)
10.
Thumb screws (4) to attach light mount to the camera (P/N 972-0282-1)
11.
Calibration Test Card (98-UA10-0CC0)
12.
UID Checker software CD (P/N A1-40266-1V230)
Getting Started With Your UID Compliance Verifier
D-1
Upgrading UIDDPM001
D
Page 112
Appendix
D
Upgrading UID-DPM001 w/UIDChecker Software V2.3
13.
Ethernet crossover adapter (P/N HEENET-XLA)
14.
Spiral wire wrap (P/N 966-0195-1)
Setting Up the UID-DPM Stand FIGURE D–1. Dowel Pins and Thumb Screw
Dowel Pins
Thumb Screw
1.
Remove the stand base and upright arm from the packaging.
2.
Place the base on a level flat surface.
3.
Slide the upright arm onto the two dowel pins in the back of the base.
4.
Fasten the upright arm using the large thumb screw provided with the kit.
5.
Be careful while moving the upright arm. The camera mounting head is spring-loaded and can move while carrying the arm.
Attaching the Camera
D-2
1.
Attach the HawkEye™ 1510 camera to the stand using the ¼-20 thumb screw that protrudes from the front of the camera mount head.
2.
Connect the HEPS-1500 power cable to the camera.
3.
Plug the HEPS-1500 power cable into a 110V outlet.
4.
Connect the HEENET-007 network cable to the camera.
Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008
Page 113
Assembling the Lights
5.
Loop the power and Ethernet cable in the wire hook on the back rear of the camera mounting head.
D Upgrading UIDDPM001
Assembling the Lights FIGURE D–2. HELTMA-4L Bracket
1.
Assemble the HELTMA-4L to the DOAL-50 using two M6x10mm screw.
Preparing the Lenses v2.3.1, Dec 2008
1.
Take the lenses out of their boxes and remove the plastic over-wrap. Store the lenses with the lens covers on.
2.
Remove the extension tubes from the box and remove plastic over-wrap.
Getting Started With Your UID Compliance Verifier
D-3
Page 114
Appendix
D
Upgrading UID-DPM001 w/UIDChecker Software V2.3
3.
Remove the lens protective cap from the bottom of the HawkEye™ 1510 camera.
Attaching the Lights to the Camera FIGURE D–3. Small Hole Caps
1.
Using a small screwdriver, remove the 4 small hole caps (two on each side) on the sides of the HawkEye™ camera.
FIGURE D–4. Thumb Screws
Thumb Screws
2.
D-4
Using the 4 thumb screws provided, attach the HELTMA-4L bracket to the HawkEye™ camera.
Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008
Page 115
Recommended Verifier Setting with 25mm Lens
Plug the CPS-12 power supply into a 110V outlet and attach the DB-9 connector to the light attached to the HELTMA bracket.
4.
Center the light on the camera by loosening the four button head screws on the side of the HELTMA and centering the light.
Recommended Verifier Setting with 25mm Lens f-stop = 2 Extension Ring = 6mm Distance from front of camera to part = 8 inches (203.2 mm) Distance from bottom of light to part = 2 inches (50.8 mm) Field of View = 1.19 inches x 0.86 inches (30.2 mm x 21.8 mm)
v2.3.1, Dec 2008
Getting Started With Your UID Compliance Verifier
D Upgrading UIDDPM001
3.
D-5
Page 116
Appendix
D
Upgrading UID-DPM001 w/UIDChecker Software V2.3
FIGURE D–5. Setting 1, 25mm Lens with 6mm Extension Ring
HE1510 25mm f-stop=2
1mm
5mm
DOAL 50
8”
D-6
Getting Started With Your UID Compliance Verifier
2” v2.3.1, Dec 2008
Page 117
Recommended Verifier Setting with 35mm Lens
Recommended Verifier Setting with 35mm Lens f-stop = 3
D Upgrading UIDDPM001
Extension Ring = 10mm Distance from front of camera to part = 9 inches (228.6 mm) Distance from bottom of light to part = 2 inches (50.8 mm) Field of View = 0.89 inches x 0.67 inches (22.6 mm x 17.0 mm)
v2.3.1, Dec 2008
Getting Started With Your UID Compliance Verifier
D-7
Page 118
Appendix
D
Upgrading UID-DPM001 w/UIDChecker Software V2.3
FIGURE D–6. Setting 2, 35mm Lens with 10mm Extension Ring
HE1510
35mm f-stop=3
10mm
DOAL 50
9”
D-8
2”
Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008
Page 119
Setting Up the Network
Setting Up the Network
1.
If you are not using a company LAN or a router between the camera and PC, you can use the included HEENET-XLA Ethernet crossover adapter. Note: Do not use the crossover adapter if you are using a router, switch, or company LAN.
2.
Follow “Networking to the UID-LDP & UID-DPM” on page 1-10 for setting up DHCP or static IP communications between your camera and PC.
Upgrading the Software 1.
Configure the hardware to Setting 1 or 2, based on the lens used.
2.
Power up the HawkEye 1510 with Ethernet cable and RS-232 serial cable connected.
3.
Install UIDChecker v2.2 to the PC and use the HawkEye_flasher to upgrade the camera firmware.
Configuring the Verifier The verifier needs to be configured every time the firmware is updated.
v2.3.1, Dec 2008
1.
Run HyperTerminal and configure the COM port to 115200, 8, Parity None, Stop bits 1, Flow control None.
2.
Select the Connect icon to make the serial connection.
Getting Started With Your UID Compliance Verifier
D-9
Upgrading UIDDPM001
D
FIGURE D–7. HEENET-XLA Ethernet Crossover Adapter
Page 120
Appendix
D
Upgrading UID-DPM001 w/UIDChecker Software V2.3
3.
Type Ctrl-P to get the prompt >.
4.
Type CONTROL.
5.
Type XLIGHTCHANNELS 1.
6.
For DOAL-50 with wavelength 660nm, type WAVELENGTH 660.
7.
Type SAVE BOOT.
8.
Type RELEASE.
9.
Type Ctrl-P.
10.
Click the Disconnect icon to disconnect.
HawkEye Sensor/Lighting Normalization To normalize the sensor response with respect to the lighting setup, use the HawkEye Normalization tool: 1.
Go to \Program Files\UIDChecker\Utilities.
2.
Double click HawkEyeNormalization.exe. The screen in Figure D–8 is displayed.
D-10
Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008