Page 41
ZT1, PNP types Technical data
ZT1-
Scanning distance typ. Light source 1), light type Light spot diameter Supply voltage VS 2) Ripple 3) Current consumption 4) Switching outputs Switching mode
5 ... 155 mm LED, infrared light, 880 nm Approx. 31 mm at 150 mm 10 ... 30 V DC < 5 VPP < 20 mA q: PNP Light switching Dark switching 50 mA 200 Hz Cable (PVC), 2 m, 3-wire Cable with plug 150 mm, M8, 4-pin Cable with plug 150 mm, M12, 4-pin
Output current IA max. Switching frequency 5) Connection type
VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature Housing material Included with delivery
A, D IP 67 Operation –25 ... +50 °C Storage –40 ... +70 °C ABS, fibreglass reinforced Mounting nut M18
1)
4)
2) 3)
Average service life 100,000 h, at TA = +25 °C Limit values Must be within VS tolerances
5) 6)
Without load With light/dark ratio 1:1 Reference voltage 50 V DC
Scanning distance 1 2 3
5
155 10
115 20
68
0 (mm) 30
60
P5215 F5215 P5221 F5221 P5231 F5231
90
120
150
7)
A = VS connections reverse-polarity protected D = Outputs overcurrent and shortcircuit protected
Order information Type ZT1-P5215 ZT1-F5215 ZT1-P5221 ZT1-F5221 ZT1-P5231 ZT1-F5231
Order no. 1045559 1045560 1045575 1045576 1045591 1045592
1 Scanning distance on white, 90 % remission 2 Scanning distance on grey, 18 % remission 3 Scanning distance on black, 6 % remission
2009-02-18
SICK
41
Page 42
ZT2 Photoelectric proximity switch, energetic, V-optic, infrared light, NPN tyDimensional drawing 13.6
Ø 3.5
24
Energetic type with V-optic Infrared light Clear housing for perfect indicator LED visibility 18 mm front and flange mounting possibility Power and output indicator
34.6
Photoelectric proximity switch
14.1 M18
25.4
Scanning distance 155 mm
10
21.9
Connection types ZT2-N5215
ZT2-N5231
ZT2-N5221
ZT2-E5215
ZT2-E5231
ZT2-E5221
3 x 0.23 mm2
M8, 4-pin
M12, 4-pin
®
Accessories Reflectors Mounting systems
42
SICK brn
L+ blu
M blk
Q
1 3 4 2
L+ M Q NC
1 3 4 2
L+ M Q NC
2009-02-18
Page 43
ZT2, NPN types Technical data
ZT2-
Scanning distance typ. Light source 1), light type Light spot diameter Supply voltage VS 2) Ripple 3) Current consumption 4) Switching outputs Switching mode
5 ... 155 mm LED, infrared light, 880 nm Approx. 31 mm at 150 mm 10 ... 30 V DC < 5 VPP < 20 mA q: NPN Light switching Dark switching 50 mA 200 Hz Cable (PVC), 2 m, 3-wire Cable with plug 150 mm, M8, 4-pin Cable with plug 150 mm, M12, 4-pin
Output current IA max. Switching frequency 5) Connection type
VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature Housing material Included with delivery
A, D IP 67 Operation –25 ... +50 °C Storage –40 ... +70 °C ABS, fibreglass reinforced Mounting nut M18
1)
4)
2) 3)
Average service life 100,000 h, at TA = +25 °C Limit values Must be within VS tolerances
5) 6)
Without load With light/dark ratio 1:1 Reference voltage 50 V DC
Scanning distance 1 2 3
5
155 10
115 20
68
0 (mm) 30
60
N5215 E5215 N5221 E5221 N5231 E5231
90
120
150
7)
A = VS connections reverse-polarity protected D = Outputs overcurrent and shortcircuit protected
Order information Type ZT2-N5215 ZT2-E5215 ZT2-N5221 ZT2-E5221 ZT2-N5231 ZT2-E5231
Order no. 1045403 1045406 1045419 1045422 1045435 1045438
1 Scanning distance on white, 90 % remission 2 Scanning distance on grey, 18 % remission 3 Scanning distance on black, 6 % remission
2009-02-18
SICK
43
Page 44
ZT2 Photoelectric proximity switch, energetic, V-optic, infrared light, PNP types Dimensional drawing 13.6
Ø 3.5
24
Energetic type with V-optic Infrared light Clear housing for perfect indicator LED visibility 18 mm front and flange mounting possibility Power and output indicator
34.6
Photoelectric proximity switch
14.1 M18
25.4
Scanning distance 155 mm
10
21.9
Connection types ZT2-P5215
ZT2-P5231
ZT2-P5221
ZT2-F5215
ZT2-F5231
ZT2-F5221
3 x 0.23 mm2
M8, 4-pin
M12, 4-pin
®
Accessories Reflectors Mounting systems
44
SICK brn
L+ blu
M blk
Q
1 3 4 2
L+ M Q NC
1 3 4 2
L+ M Q NC
2009-02-18
Page 45
ZT2, PNP types Technical data
ZT2-
Scanning distance typ. Light source 1), light type Light spot diameter Supply voltage VS 2) Ripple 3) Current consumption 4) Switching outputs Switching mode
5 ... 155 mm LED, infrared light, 880 nm Approx. 31 mm at 150 mm 10 ... 30 V DC < 5 VPP < 20 mA q: PNP Light switching Dark switching 50 mA 200 Hz Cable (PVC), 2 m, 3-wire Cable with plug 150 mm, M8, 4-pin Cable with plug 150 mm, M12, 4-pin
Output current IA max. Switching frequency 5) Connection type
VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature Housing material Included with delivery
A, D IP 67 Operation –25 ... +50 °C Storage –40 ... +70 °C ABS, fibreglass reinforced Mounting nut M18
1)
4)
2) 3)
Average service life 100,000 h, at TA = +25 °C Limit values Must be within VS tolerances
5) 6)
Without load With light/dark ratio 1:1 Reference voltage 50 V DC
Scanning distance 1 2 3
5
155 10
115 20
68
0 (mm) 30
60
P5215 F5215 P5221 F5221 P5231 F5231
90
120
150
7)
A = VS connections reverse-polarity protected D = Outputs overcurrent and shortcircuit protected
Order information Type ZT2-P5215 ZT2-F5215 ZT2-P5221 ZT2-F5221 ZT2-P5231 ZT2-F5231
Order no. 1045404 1045405 1045420 1045421 1045436 1045437
1 Scanning distance on white, 90 % remission 2 Scanning distance on grey, 18 % remission 3 Scanning distance on black, 6 % remission
2009-02-18
SICK
45
Page 46
ZT2 Photoelectric proximity switch, energetic, V-optic, infrared light, NPN types Dimensional drawing
25.4 25.4
Ø 3.5
34.6
Energetic type with V-optic Infrared light Clear housing for perfect indicator LED visibility 18 mm front and flange mounting possibility Power and output indicator
41.9
Photoelectric proximity switch
14.1 M18
24
13.6
24
Scanning distance 155 mm
10 18
31.7 14.1 M18
34.6
45.2
13.6
Ø 3.5
10 18
31.7
Connection types ZT2-N5238
ZT2-N5228
ZT2-E5238
ZT2-E5228
M8, 4-pin
M12, 4-pin
®
Accessories Reflectors Mounting systems
1 3 4 2
46
SICK
L+ M Q NC
1 3 4 2
L+ M Q NC
2009-02-18
Page 47
ZT2, NPN types Technical data
ZT2-
Scanning distance typ. Light source 1), light type Light spot diameter Supply voltage VS 2) Ripple 3) Current consumption 4) Switching outputs Switching mode
5 ... 155 mm LED, infrared light, 880 nm Approx. 31 mm at 150 mm 10 ... 30 V DC < 5 VPP < 20 mA q: NPN Light switching Dark switching 50 mA 200 Hz M8 plug, 4-pin M12 plug, 4-pin
Output current IA max. Switching frequency 5) Connection type VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature Housing material Included with delivery
A, D IP 67 Operation –25 ... +50 °C Storage –40 ... +70 °C ABS, fibreglass reinforced Mounting nut M18
1)
4)
2) 3)
Average service life 100,000 h, at TA = +25 °C Limit values Must be within VS tolerances
5) 6)
Without load With light/dark ratio 1:1 Reference voltage 50 V DC
Scanning distance 1 2 3
5
155 10
115 20
68
0 (mm) 30
60
N5238 E5238 N5228 E5228
90
120
7)
A = VS connections reverse-polarity protected D = Outputs overcurrent and shortcircuit protected
Order information Type ZT2-N5238 ZT2-E5238 ZT2-N5228 ZT2-E5228
Order no. 1045484 1045487 1045468 1045471
150
1 Scanning distance on white, 90 % remission 2 Scanning distance on grey, 18 % remission 3 Scanning distance on black, 6 % remission
2009-02-18
SICK
47
Page 48
ZT2 Photoelectric proximity switch, energetic, V-optic, infrared light, PNP types Dimensional drawing
25.4 25.4
Ø 3.5
34.6
Energetic type with V-optic Infrared light Clear housing for perfect indicator LED visibility 18 mm front and flange mounting possibility Power and output indicator
41.9
Photoelectric proximity switch
14.1 M18
24
13.6
24
Scanning distance 155 mm
10 18
31.7 14.1 M18
34.6
45.2
13.6
Ø 3.5
10 18
31.7
Connection types ZT2-P5238
ZT2-P5228
ZT2-F5238
ZT2-F5228
M8, 4-pin
M12, 4-pin
®
Accessories Reflectors Mounting systems
1 3 4 2
48
SICK
L+ M Q NC
1 3 4 2
L+ M Q NC
2009-02-18
Page 49
ZT2, PNP types Technical data
ZT2-
Scanning distance typ. Light source 1), light type Light spot diameter Supply voltage VS 2) Ripple 3) Current consumption 4) Switching outputs Switching mode
5 ... 155 mm LED, infrared light, 880 nm Approx. 31 mm at 150 mm 10 ... 30 V DC < 5 VPP < 20 mA q: PNP Light switching Dark switching 50 mA 200 Hz M8 plug, 4-pin M12 plug, 4-pin
Output current IA max. Switching frequency 5) Connection type VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature Housing material Included with delivery
A, D IP 67 Operation –25 ... +50 °C Storage –40 ... +70 °C ABS, fibreglass reinforced Mounting nut M18
1)
4)
2) 3)
Average service life 100,000 h, at TA = +25 °C Limit values Must be within VS tolerances
5) 6)
Without load With light/dark ratio 1:1 Reference voltage 50 V DC
Scanning distance 1 2 3
5
155 10
115 20
68
0 (mm) 30
60
P5238 F5238 P5228 F5228
90
120
7)
A = VS connections reverse-polarity protected D = Outputs overcurrent and shortcircuit protected
Order information Type ZT2-P5238 ZT2-F5238 ZT2-P5228 ZT2-F5228
Order no. 1045485 1045486 1045469 1045470
150
1 Scanning distance on white, 90 % remission 2 Scanning distance on grey, 18 % remission 3 Scanning distance on black, 6 % remission
2009-02-18
SICK
49
Page 50
ZL1 Photoelectric reflex switch, red light, NPN types Dimensional drawing 13.6
Ø 3.5
24
Visible red light With polarization filter Cross talk immunity 18 mm front and flange mounting possibility Power and output indicator Clear housing for perfect indicator LED visibility
34.8
Photoelectric reflex switch
14.1 M18
25.4
Scanning range 0.1 … 4.8 m
10
23
Connection types ZL1-N2415
ZL1-N2431
ZL1-N2421
ZL1-E2415
ZL1-E2431
ZL1-E2421
3 x 0.23 mm2
M8, 4-pin
M12, 4-pin
®
Accessories Reflectors Mounting systems
50
SICK brn
L+ blu
M blk
Q
1 3 4 2
L+ M Q NC
1 3 4 2
L+ M Q NC