The text of a spec sheet · part 3 of 7
Data Sheet: Z sensor, pages 21 to 30
Pages 21 to 30 of 68
The original document is the PDF (6.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick ZT1
Page 21
ZT2, PNP types Technical data
ZT2-
Scanning distance typ. Light source 1), light type Light spot diameter Supply voltage VS 2) Ripple 3) Current consumption 4) Switching outputs Switching mode
1 ... 100 mm LED, infrared light, 880 nm Approx. 20 mm at 100 mm 10 ... 30 V DC < 5 VPP < 20 mA q: PNP Light switching Dark switching 50 mA 200 Hz Cable (PVC), 2 m, 3-wire Cable with plug 150 mm, M8, 4-pin Cable with plug 150 mm, M12, 4-pin
Output current IA max. Switching frequency 5) Connection types
VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature Housing material Included with delivery
A, D IP 67 Operation –25 ... +50 °C Storage –40 ... +70 °C ABS, fibreglass reinforced Mounting nut M18
1)
4)
2) 3)
Average service life 100,000 h, at TA = +25 °C Limit values Must be within VS tolerances
5) 6)
Without load With light/dark ratio 1:1 Reference voltage 50 V DC
Scanning distance 1
1
100
2
3
3
6
0 (mm) 20
82 74
40
P4215 F4215 P4221 F4221 P4231 F4231
60
80
100
7)
A = VS connections reverse-polarity protected D = Outputs overcurrent and shortcircuit protected
Order information Type ZT2-P4215 ZT2-F4215 ZT2-P4221 ZT2-F4221 ZT2-P4231 ZT2-F4231
Order no. 1045412 1045413 1045428 1045429 1045444 1045445
1 Scanning distance on white, 90 % remission 2 Scanning distance on grey, 18 % remission 3 Scanning distance on black, 6 % remission
2009-02-18
SICK
21
Page 22
ZT2 Photoelectric proximity switch, energetic, infrared light, NPN types Dimensional drawing
25.4 25.4
Ø 3.5
34.6
Energetic type Infrared light Clear housing for perfect indicator LED visibility 18 mm front and flange mounting possibility Output indicator
41.9
Photoelectric proximity switch
14.1 M18
24
13.6
24
Scanning distance 100 mm
10 18
31.7 14.1 M18
34.6
45.2
13.6
Ø 3.5
10 18
31.7
Connection types ZT2-N4238
ZT2-N4228
ZT2-E4238
ZT2-E4228
M8, 4-pin
M12, 4-pin
®
Accessories Reflectors Mounting systems
1 3 4 2
22
SICK
L+ M Q NC
1 3 4 2
L+ M Q NC
2009-02-18
Page 23
ZT2, NPN types Technical data
ZT2-
Scanning distance typ. Light source 1), light type Light spot diameter Supply voltage VS 2) Ripple 3) Current consumption 4) Switching outputs Switching mode
1 ... 100 mm LED, infrared light, 880 nm Approx. 20 mm at 100 mm DC 10 ... 30 V < 5 VPP < 20 mA q: NPN Light switching Dark switching 50 mA 200 Hz M8 plug, 4-pin M12 plug, 4-pin
Output current IA max. Switching frequency 5) Connection type VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature Housing material Included with delivery
A, D IP 67 Operation –25 ... +50 °C Storage –40 ... +70 °C ABS, fibreglass reinforced Mounting nut M18
1)
4)
2) 3)
Average service life 100,000 h, at TA = +25 °C Limit values Must be within VS tolerances
5) 6)
Without load With light/dark ratio 1:1 Reference voltage 50 V DC
Scanning distance 1
1
100
2
3
3
6
0 (mm) 20
82 74
40
N4238 E4238 N4228 E4228
60
80
7)
A = VS connections reverse-polarity protected D = Outputs overcurrent and shortcircuit protected
Order information Type ZT2-N4238 ZT2-E4238 ZT2-N4228 ZT2-E4228
Order no. 1045492 1045495 1045476 1045479
100
1 Scanning distance on white, 90 % remission 2 Scanning distance on grey, 18 % remission 3 Scanning distance on black, 6 % remission
2009-02-18
SICK
23
Page 24
ZT2 Photoelectric proximity switch, energetic, infrared light, PNP types Dimensional drawing
25.4 25.4
Ø 3.5
34.6
Energetic type Infrared light Clear housing for perfect indicator LED visibility 18 mm front and flange mounting possibility Output indicator
41.9
Photoelectric proximity switch
14.1 M18
24
13.6
24
Scanning distance 100 mm
10 18
31.7 14.1 M18
34.6
45.2
13.6
Ø 3.5
10 18
31.7
Connection types ZT2-P4238
ZT2-P4228
ZT2-F4238
ZT2-F4228
M8, 4-pin
M12, 4-pin
®
Accessories Reflectors Mounting systems
1 3 4 2
24
SICK
L+ M Q NC
1 3 4 2
L+ M Q NC
2009-02-18
Page 25
ZT2, PNP types Technical data
ZT2-
Scanning distance typ. Light source 1), light type Light spot diameter Supply voltage VS 2) Ripple 3) Current consumption 4) Switching outputs Switching mode
1 ... 100 mm LED, infrared light, 880 nm Approx. 20 mm at 100 mm 10 ... 30 V DC < 5 VPP < 20 mA q: PNP Light switching Dark switching 50 mA 200 Hz M8 plug, 4-pin M12 plug, 4-pin
Output current IA max. Switching frequency 5) Connection types VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature Housing material Included with delivery
A, D IP 67 Operation –25 ... +50 °C Storage –40 ... +70 °C ABS, fibreglass reinforced Mounting nut M18
1)
4)
2) 3)
Average service life 100,000 h, at TA = +25 °C Limit values Must be within VS tolerances
5) 6)
Without load With light/dark ratio 1:1 Reference voltage 50 V DC
Scanning distance 1
1
100
2
3
3
6
0 (mm) 20
82 74
40
P4238 F4238 P4228 F4228
60
80
7)
A = VS connections reverse-polarity protected D = Outputs overcurrent and shortcircuit protected
Order information Type ZT2-P4238 ZT2-F4238 ZT2-P4228 ZT2-F4228
Order no. 1045493 1045494 1045477 1045478
100
1 Scanning distance on white, 90 % remission 2 Scanning distance on grey, 18 % remission 3 Scanning distance on black, 6 % remission
2009-02-18
SICK
25
Page 26
ZT1 Photoelectric proximity switch, energetic, V-optic, red light, NPN types Dimensional drawing 13.6
Ø 3.5
24
Energetic type with V-optic Red light Clear housing for perfect indicator LED visibility 18 mm front and flange mounting possibility Power and output indicator
34.8
Photoelectric proximity switch
14.1 M18
25.4
Scanning distance 60 mm
10
23
Connection types ZT1-N2215
ZT1-N2231
ZT1-N2221
ZT1-E2215
ZT1-E2231
ZT1-E2221
3 x 0.23 mm2
M8, 4-pin
M12, 4-pin
®
Accessories Reflectors Mounting systems
26
SICK brn
L+ blu
M blk
Q
1 3 4 2
L+ M Q NC
1 3 4 2
L+ M Q NC
2009-02-18
Page 27
ZT1, NPN types Technical data
ZT1-
Scanning distance typ. Light source 1), light type Light spot diameter Supply voltage VS 2) Ripple 3) Current consumption 4) Switching outputs Switching mode
5 ... 60 mm LED, red light, 660 nm Approx. 8 mm at 60 mm 10 ... 30 V DC < 5 VPP < 20 mA q: NPN Light switching Dark switching 50 mA 200 Hz Cable (PVC), 2 m, 3-wire Cable with plug 150 mm, M8, 4-pin Cable with plug 150 mm, M12, 4-pin
Output current IA max. Switching frequency 5) Connection types
VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature Housing material Included with delivery
A, D IP 67 Operation –25 ... +50 °C Storage –40 ... +70 °C ABS, fibreglass reinforced Mounting nut M18
1)
4)
2) 3)
Average service life 100,000 h, at TA = +25 °C Limit values Must be within VS tolerances
5) 6)
Without load With light/dark ratio 1:1 Reference voltage 50 V DC
Scanning distance 1 2
5
60 10
0 (mm) 10
45
20
30
40
50
1 Scanning distance on white, 90 % remission 2 Scanning distance on grey, 18 % remission 3 Scanning distance on black, 6 % remission
2009-02-18
N2215 E2215 N2221 E2221 N2231 E2231
60
7)
A = VS connections reverse-polarity protected D = Outputs overcurrent and shortcircuit protected
Order information Type ZT1-N2215 ZT1-E2215 ZT1-N2221 ZT1-E2221 ZT1-N2231 ZT1-E2231
Order no. 1045554 1045557 1045570 1045573 1045586 1045589
SICK
27
Page 28
ZT1 Photoelectric proximity switch, energetic, V-optic, red light, PNP types Dimensional drawing 13.6
Ø 3.5
24
Energetic type with V-optic Red light Clear housing for perfect indicator LED visibility 18 mm front and flange mounting possibility Power and output indicator
34.8
Photoelectric proximity switch
14.1 M18
25.4
Scanning distance 60 mm
10
23
Connection types ZT1-P2215
ZT1-P2231
ZT1-P2221
ZT1-F2215
ZT1-F2231
ZT1-F2221
3 x 0.23 mm2
M8, 4-pin
M12, 4-pin
®
Accessories Reflectors Mounting systems
28
SICK brn
L+ blu
M blk
Q
1 3 4 2
L+ M Q NC
1 3 4 2
L+ M Q NC
2009-02-18
Page 29
ZT1, PNP types Technical data
ZT1-
Scanning distance typ. Light source 1), light type Light spot diameter Supply voltage VS 2) Ripple 3) Current consumption 4) Switching outputs Switching mode
5 ... 60 mm LED, red light, 660 nm Approx. 8 mm at 60 mm 10 ... 30 V DC < 5 VPP < 20 mA q: PNP Light switching Dark switching 50 mA 200 Hz Cable (PVC), 2 m, 3-wire Cable with plug 150 mm, M8, 4-pin Cable with plug 150 mm, M12, 4-pin
Output current IA max. Switching frequency 5) Connection types
VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature Housing material Included with delivery
A, D IP 67 Operation –25 ... +50 °C Storage –40 ... +70 °C ABS, fibreglass reinforced Mounting nut M18
1)
4)
2) 3)
Average service life 100,000 h, at TA = +25 °C Limit values Must be within VS tolerances
5) 6)
Without load With light/dark ratio 1:1 Reference voltage 50 V DC
Scanning distance 1 2
5
60 10
0 (mm) 10
45
20
30
40
50
1 Scanning distance on white, 90 % remission 2 Scanning distance on grey, 18 % remission 3 Scanning distance on black, 6 % remission
2009-02-18
P2215 F2215 P2221 F2221 P2231 F2231
60
7)
A = VS connections reverse-polarity protected D = Outputs overcurrent and shortcircuit protected
Order information Type ZT1-P2215 ZT1-F2215 ZT1-P2221 ZT1-F2221 ZT1-P2231 ZT1-F2231
Order no. 1045555 1045556 1045571 1045572 1045587 1045588
SICK
29
Page 30
ZT2 Photoelectric proximity switch, energetic, V-optic, red light, NPN types Dimensional drawing 13.6
Ø 3.5
24
Energetic type with V-optic Red light Clear housing for perfect indicator LED visibility 18 mm front and flange mounting possibility Power and output indicator
34.6
Photoelectric proximity switch
14.1 M18
25.4
Scanning distance 60 mm
10
21.9
Connection types ZT2-N2215
ZT2-N2231
ZT2-N2221
ZT2-E2215
ZT2-E2231
ZT2-E2221
3 x 0.23 mm2
M8, 4-pin
M12, 4-pin
®
Accessories Reflectors Mounting systems
30
SICK brn
L+ blu
M blk
Q
1 3 4 2
L+ M Q NC
1 3 4 2
L+ M Q NC
2009-02-18