The text of a spec sheet · part 2 of 2
W 4-2 Photoelectric switches (SENSICK Catalogue 2000), pages 9 to 16
Pages 9 to 16 of 16
The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick WT4
Page 9
WL 4-2 Photoelectric reflex switches, red light, dark-switching -- DC
Scanning range 2.8 m
Dimensional drawing
12
16
Photoelectric reflex switches
2 3
15.6 installed opposite each other ■ Permissible operating temperature
9
-- 40 °C . . . + 60 °C
4 max. 17.5
■ Rapid response time
M3
3.5
■ Reliable operation if devices are
32
(HF lamps, flashing warning lamps)
5.5
1
■ Insensitive to ambient light sources
9.5
1 2 3 4
LED signal strength indicator Optical axis, receiver Optical axis, sender M 3 threaded mounting hole
Connection types WL 4-2E 132 WL 4-2F 132
WL 4-2E 330 WL 4-2F 330
WL 4-2E 331 WL 4-2F 331
3 x 0.25 mm2
3-pin, M 8
3-pin, M 8
C
Accessories Cable receptacles Reflectors page 496 520 brn
L+ brn
1 blu
M blu
3
Q blk
4 blk
54
SENSICK CATALOGUE
L+ brn
1
M blu
3
Q blk
4
L+ M Q
Page 10
WL 27-2 Technical data
WL 4-2
Scanning range, max. typical/ on reflector Light source 1), light type Light spot diameter At focal point
LED, red light 230 mm at 1.5 m Approx. 3.5 mm at 90 mm
Supply voltage VS Ripple 3) Current consumption 4)
10 . . . 30 V DC 2) 5 VSS < 20 mA
Switching outputs Switching mode Output current IA max.
PNP, Q NPN, Q Dark-switching 100 mA
PNP; signal voltage HIGH PNP; signal voltage LOW NPN; signal voltage HIGH NPN; signal voltage LOW Response time5) Max. switching frequency 6)
VS – (< 2.5 V) Approx. 0 V Approx. VS < 1.5 V < 500 µs 1000/s
Connection types
Cable 7), 2 m Plug M 8 Cable 7), 100 mm, with plug
VDE protection class Circuit protection 8) Enclosure rating 9) Ambient temperature TA
E 132 E 330 E 331 F 132 F 330 F 331
2.8 m/PL 80 A
A, B, C IP 67 Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 20 g
Weight Polarising filter Housing material
PC, polycarbonate
1) Average service life 100,000 h where TA = + 25 °C 2) Limit values 3) May not exceed or fall short of VS tolerances
4) Without load 5) Signal transit time with resistive load 6) With light/dark ratio 1:1 7) Do not bend below 0 °C
9) IP 67: with screw-in cable receptacles IP 65: with plug-in cable receptacles
8) A = VS connections reverse-polarity protected B = Output Q short-circuit protected C = Interference pulse suppression
Order information Type Part no. WL 4-2E 132 1 015 770
Operating range and operating reserve 100 1 0
1.7
2 0
1.1
3 0
0.8
4 0 0.4
2.8
WL 4-2E 330 WL 4-2E 331 WL 4-2F 132 WL 4-2F 330 WL 4-2F 331
1.8 1.5
0.8 0.7
6 0 0.4
0.7
0 (m) 0.5
1
1.5
2
Reflector type
Operating range
1
PL 80 A PL 50 A
0 . . .1.7 m 0 . . .1.1 m
PL 40 A PL 30 A PL 20 A Reflective tape Diamond Grade
0 . . . 0.8 m 0 . . . 0.4 m 0 . . . 0.4 m 35 . . . 400 mm
2 3 4 5 6
1 015 766 1 015 762 1 015 768 1 015 764 1 015 760
10 2.5
3
1 Operating reserve
5 0 0.4
WL 4-2
6 Scanning range, max. typical
1 (m)
1
Operating range
3
2
3
SENSICK CATALOGUE
55
Page 11
WL 4G-2 Photoelectric reflex switches, for transparent objects, red light -- DC Dimensional drawing
12
16
3
Scanning range 1.6 m Photoelectric reflex switches
(HF lamps, flashing warning lamps)
3
15.6
■ Reliable operation if devices are installed opposite each other
9
M3
■ Permissible operating temperature
4 max. 17.5
-- 40 °C . . . + 60 °C ■ Rapid response time
3.5
2
5.5
■ Insensitive to ambient light sources
32
1
■ Detects glass and transparent films
9.5
4.9
5
Adjustments possible WL 4G-2F 330
1 2 3 4 5
5
Connection type WL 4G-2F 330
C
Accessories Cable receptacles Reflectors
56
SENSICK CATALOGUE page 496 520
3-pin, M 8 brn
1 blu
3 blk
4
L+ M Q
LED signal strength indicator Optical axis, receiver Optical axis, sender M 3 threaded mounting hole Sensitivity control
Page 12
WL 4G-2 Technical data
WL 4G-2
Scanning range, max. typical/ on reflector Sensitivity
Adjustable
Light source 1), light type Light spot diameter
LED, red light 230 mm at 1.5 m
Supply voltage VS Ripple 3) Current consumption 4)
10 . . . 30 V DC 2) 5 VSS < 20 mA
Switching outputs Switching mode Output current IA max. PNP; signal voltage HIGH PNP; signal voltage LOW Response time5) Max. switching frequency 6)
PNP, Q Dark-switching 100 mA VS – (< 2.5 V) Approx. 0 V < 500 µs 1000/s
Connection type
Plug M 8
VDE protection class Circuit protection 7) Enclosure rating 8) Ambient temperature TA
F 330
1.6 m/PL 80 A
A, B, C IP 67 Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 20 g
Weight Polarising filter Housing material
PC, polycarbonate 4) Without load 5) Signal transit time with resistive load 6) With light/dark ratio 1:1
1) Average service life 100,000 h where TA = + 25 °C 2) Limit values 3) May not exceed or fall short of VS tolerances
8) IP 67: with screw-in cable receptacles IP 65: with plug-in cable receptacles
7) A = VS connections reverse-polarity protected B = Output Q short-circuit protected C = Interference pulse suppression
Order information Type Part no. WL 4G-2F 330 1 016 209
Operating range and transmission attenuation 0.05
2
0.05
3
0.05
4
0.05
0 (m)
20
1.0 0.6 0.5 0.35
0.2
0.4
0.6
■ Operating range Reflector type
Operating range
1 PL 80 A 2 PL 50 A
0.05 . . .1.0 m 0.05 . . . 0.6 m
3 PL 40 A 4 PL 30 A
0.05 . . . 0.5 m 0.05 . . . 0.35 m
0.8
1.0
Transmission attenuation in % (single light beam)
1
18 16 14 12 10 8 6 4 2 0 (m)
0.2
0.4
0.6
0.8
1
SENSICK CATALOGUE
57
Page 13
WS/WE 4-2 Through-beam photoelectric switches, light-switching -- DC Dimensional drawing
Scanning range 4m
12
16
Through-beam photoelectric switches
3
15.6
-- 40 °C . . . + 60 °C ■ Rapid response time
9
■ Test input for system diagnosis
M3
3.5
2
■ Permissible operating temperature
5.5
(HF lamps, flashing warning lamps)
32
1
■ Insensitive to ambient light sources max. 17.5
4
9.5
1 2 3 4
LED signal strength indicator Optical axis, receiver Optical axis, sender M 3 threaded mounting hole
Connection types
C
Accessories Cable receptacles
Sender page 496
Receiver
WS/WE 4-2P 132 WS/WE 4-2N 132
WS/WE 4-2P 330 WS/WE 4-2N 330
WS/WE 4-2P 331 WS/WE 4-2N 331
3 x 0.25 mm2
3-pin, M 8
3-pin, M 8 brn
L+ brn
1 blu
M blu
3 blk
TE blk
4 brn
L+ brn
1 blu
M blu
3
Q blk
4 blk
58
SENSICK CATALOGUE
L+ brn
1
M blu
3
TE blk
4
L+ brn
1
M blu
3
Q blk
4
L+ M TE
L+ M Q
Page 14
WS/WE 4-2 Technical data
WS/WE 4-2
Scanning range, max. typical
0...4 m
Light source 1), light type Light spot diameter Angle of dispersion
LED, red light Approx. 340 mm at 2 m Approx. 12°
Supply voltage VS Ripple 3) Current consumption 4) sender receiver
10 . . . 30 V DC 2) 5 VSS < 50 mA < 20 mA < 30 mA
Switching outputs
PNP, Q NPN, Q
Switching mode Output current IA max. PNP; signal voltage HIGH PNP; signal voltage LOW NPN; signal voltage HIGH NPN; signal voltage LOW Response time 5) Max. switching frequency 6)
Light-switching 100 mA VS – (< 2.5 V) Approx. 0 V Approx. VS < 1.5 V < 500 µs 1000/s
Test input ”TE” Sender OFF
TE to 0 V
Connection types
Cable 7), 2 m Plug M 8 Cable 7), 100 mm, with plug
VDE protection class Circuit protection 8) Enclosure rating 9) Ambient temperature TA
P 132 P 330 P 331 N 132 N 330 N 331
A, B, C IP 67 Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 20 g PC, polycarbonate
Weight Housing material 1) Average service life 100,000 h where TA = + 25 °C 2) Limit values 3) May not exceed or fall short of VS tolerances
4) Without load 5) Signal transit time with resistive load 6) With light/dark ratio 1:1 7) Do not bend below 0 °C
9) IP 67: with screw-in cable receptacles IP 65: with plug-in cable receptacles
8) A = VS connections reverse-polarity protected B = Output Q short-circuit protected C = Interference pulse suppression
Operating range and operating reserve
Order information Type Part no. WS/WE 4-2P 132 1 015 779 WS/WE 4-2P 330 1 015 775 WS/WE 4-2P 331 1 015 771 WS/WE 4-2N 132 1 015 781 WS/WE 4-2N 330 1 015 777 WS/WE 4-2N 331 1 015 773
100 0
1
■ Operating range
2
3
4
4 range, ■ Scanning max. typical 10
Operating reserve
0 (m)
3.5
Operating range Scanning range, max. typical 1 (m)
1
2
3
4 SENSICK CATALOGUE
59
Page 15
WS/WE 4-2 Through-beam photoelectric switches, dark-switching -- DC Dimensional drawing
Scanning range 4m
12
16
Through-beam photoelectric switches
3
15.6
-- 40 °C . . . + 60 °C ■ Rapid response time
9
■ Test input for system diagnosis
M3
3.5
2
■ Permissible operating temperature
5.5
(HF lamps, flashing warning lamps)
32
1
■ Insensitive to ambient light sources max. 17.5
4
9.5
1 2 3 4
LED signal strength indicator Optical axis, receiver Optical axis, sender M 3 threaded mounting hole
Connection types
C
Accessories Cable receptacles
Sender page 496
Receiver
WS/WE 4-2E 132 WS/WE 4-2F 132
WS/WE 4-2E 330 WS/WE 4-2F 330
WS/WE 4-2E 331 WS/WE 4-2F 331
3 x 0.25 mm2
3-pin, M 8
3-pin, M 8 brn
L+ brn
1 blu
M blu
3 blk
TE blk
4 brn
L+ brn
1 blu
M blu
3
Q blk
4 blk
60
SENSICK CATALOGUE
L+ brn
1
M blu
3
TE blk
4
L+ brn
1
M blu
3
Q blk
4
L+ M TE
L+ M Q
Page 16
WS/WE 4-2 Technical data
WS/WE 4-2
Scanning range, max. typical
0...4 m
Light source 1), light type Light spot diameter Angle of dispersion
LED, red light Approx. 340 mm at 2 m Approx. 12°
Supply voltage VS Ripple 3) Current consumption 4) sender receiver
10 . . . 30 V DC 2) 5 VSS < 50 mA < 50 mA < 30 mA
Switching outputs Switching mode Output current IA max. PNP; signal voltage HIGH PNP; signal voltage LOW NPN; signal voltage HIGH NPN; signal voltage LOW Response time 5) Max. switching frequency 6)
PNP, Q NPN, Q Dark-switching 100 mA VS – (< 2.5 V) Approx. 0 V Approx. VS < 1.5 V < 500 µs 1000/s
Test input ”TE” Sender OFF
TE to 0 V
Connection types
Cable 7), 2 m Plug Cable 7), 100 mm, with plug
VDE protection class Circuit protection 8) Enclosure rating 9) Ambient temperature TA
E 132 E 330 E 331 F 132 F 330 F 331
A, B, C IP 67 Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 20 g PC, polycarbonate
Weight Housing material 1) Average service life 100,000 h where TA = + 25 °C 2) Limit values 3) May not exceed or fall short of VS tolerances
4) Without load 5) Signal transit time with resistive load 6) With light/dark ratio 1:1 7) Do not bend below 0 °C
9) IP 67: with screw-in cable receptacles IP 65: with plug-in cable receptacles
8) A = VS connections reverse-polarity protected B = Output Q short-circuit protected C = Interference pulse suppression
Operating range and operating reserve
Order information Type Part no. WS/WE 4-2E 132 1 015 782 WS/WE 4-2E 330 1 015 778 WS/WE 4-2E 331 1 015 774 WS/WE 4-2F 132 1 015 780 WS/WE 4-2F 330 1 015 776 WS/WE 4-2F 331 1 015 772
100 0
1
■ Operating range
2
3
4
4 range, ■ Scanning max. typical 10
Operating reserve
0 (m)
3.5
Operating range Scanning range, max. typical 1 (m)
1
2
3
4 SENSICK CATALOGUE
61