For the Sick WL27

Page 9

DB W 27-2_Teil 1_en.qxp 28.06.2002 14:47 Uhr Seite 9

WT 27-2 Technical data

WT 27-2

Scanning distance

100 . . .1500 mm, adjustable

Light source 1), light type Light spot diameter

LED, infrared light Approx. 25 mm at 800 mm

Supply voltage VS Ripple3) Current consumption4)

10 . . . 30 V DC 2) ≤ 5 VPP ≤ 25 mA ≤ 35 mA, front screen heating

Output current IA max. Response time 5)

– PNP, Q and Q – NPN, Q and Q 100 mA 2 ms

Max. switching frequency6) Selectable delay ranges

250/s 0.5 . . .10 s/0.02 . . . 0.5 s

Test input “TE”, sender OFF

PNP : Test input to 0 V NPN : Test input to VS

Connection types

Cable 7), 2 m Plug

VDE protection class 8) Circuit protection 9) Enclosure rating

V

Switching outputs

F 112 F 410 N 410 F 411 F 440 P 410 P 610 N 610 F 710

A, B, C IP 67 IP 65 Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 100 g

Ambient temperature TA Weight Front screen heating Housing material

ABS

1)

3)

Average service life 100,000 h at TA = + 25 °C 2) Limit values

May not exceed or fall short of VS tolerances 4) Without load 5) Signal transit time with resistive load

6)

9)

With light/dark ratio 1:1 Do not bend below 0 °C 8) Reference voltage 50 V DC 7)

Order information Type Part no. WT 27-2F 112 1 015 076 WT 27-2F 410 1 013 268 WT 27-2N 410 1 016 030 WT 27-2F 411 1 015 085 WT 27-2F 440 1 015 079 WT 27-2P 410 1 015 138 WT 27-2P 610 1 015 089 WT 27-2N 610 1 015 087 WT 27-2F 710 1 015 083

Scanning distance 1

30

2

30

3

30

0 (mm)

20

800

18

1200

16

1500

300

600

900

1200

1500

14

1 Scanning distance on black, 6 % remission

12

2 Scanning distance on grey, 18 % remission

10

6%/90% 1

3 Scanning distance on white, 90 % remission

18%/90% 2

% of scanning distance

A = VS connections reverse-polarity protected – B = Output Q and Q short-circuit protected C = Interference pulse suppression

8 6 90%/90%

4

3 2 0

(mm)

300

600

900

1200

1500

SENSICK

9

Page 10

DB W 27-2_Teil 1_en.qxp 28.06.2002 14:47 Uhr Seite 10

WT 27-2 Photoelectric proximity switches, background suppression, infrared light -- UC Dimensional drawing

24.6

Photoelectric proximity switches

2

7

17

6 8 61

70

4

43.5

3

80

1

50

Infrared light Adjustable background suppression Selectable time delay

53.5

18

Scanning distance 100 . . . 1500 mm

5.2 max. 16 5

5

40 50

Adjustments possible WT 27-2S 112 WT 27-2R 610

WT 27-2S 710

6

7

8 t0 t0 t1+t2 t1+ t2 dark light t1 t2 t1 t2

0,5 – 10 s

Accessories Connectors Mounting systems

10

SENSICK

1 2 3 4 5

Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l 5.2 mm 6 Sensitivity adjustment 7 Time control 8 Time delay selector switch X Light-switching ● Dark-switching Switch-selectable time delay 0.5 – 10 s t0 Without time delay t1 OFF-delay from trailing edge of object t2 ON-delay from leading edge of object t1 + t2 OFF- and ON-delay

Connection type WT 27-2S 112

WT 27-2R 610

WT 27-2S 710

5 x 0.25 mm2

6-pin, Q6, AC/UC

7-pin, Q7, AC/UC blk blk blu blu red red brn brn ora ora

5

Page 11

DB W 27-2_Teil 1_en.qxp 28.06.2002 14:47 Uhr Seite 11

WT 27-2 Technical data

WT 27-2

Scanning distance

100 . . .1500 mm, adjustable

Light source 1), light type Light spot diameter

LED, infrared light Approx. 25 mm at 800 mm

Supply voltage VS Current consumption

24 . . . 240 V UC (+ 10 %, – 20 %) < 2 VA

Switching outputs Max. switching voltage Max. switching current Max. switching capacity Response time Max. switching frequency 3)

SPDT, isolated 2) 250 V AC / DC 120 V 4 A / 240 V AC or 24 V DC AC 1000 V A / DC 100 W < 6 ms 10/s

Delay range

0.5 . . .10 s

Connection types

Cable 4), 2 m Plug

VDE protection class 5)

V

Circuit protection 6) Enclosure rating

A, C IP 67 IP 65

Ambient temperature TA Weight Housing material

Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 100 g ABS

1)

3)

Average service life 100,000 h at TA = + 25 °C 2) Provide suitable spark suppression for inductive and capacitive loads

S 112 R 6107) S 710

6)

With light/dark ratio 1:1 Do not bend below 0 °C 5) Reference voltage 250 V AC 4)

A = VS connections reverse-polarity protected C = Interference pulse suppression

20 30

2

30

3

30

0 (mm)

800

18 1200

Relay contacts are separate from the power supply by basis insulation of 3 mm

Order information Type Part no. WT 27-2S 112 1 015 093 WT 27-2R 610 1 015 091 WT 27-2S 710 1 015 096

Scanning distance 1

7)

16 1500

300

600

900

1200

14

1500

6%/90%

12 1 Scanning distance on black, 6 % remission

1 10

2 Scanning distance on grey, 18 % remission

2 % of scanning distance

3 Scanning distance on white, 90 % remission

18%/90%

8 6 90%/90%

4

3 2 0

(mm)

300

600

900

1200

1500

SENSICK

11

Page 12

DB W 27-2_Teil 1_en.qxp 28.06.2002 14:47 Uhr Seite 12

WT 27-2 ASI Photoelectric proximity switches, background suppression, red/infrared light -- DC Dimensional drawing

24.6

53.5

2

50

5.2 max. 16 5 WT 27-2Z 210 WT 27-2Z 240

6

Connection type WT 27-2Z 230 WT 27-2Z 210 WT 27-2Z 240

4-pin, M 12

AS-i +

AS-i –

SENSICK

5

40 50

Adjustments possible WT 27-2Z 230

12

6

61

4

Red/infrared light Adjustable background suppression Front screen heating, optional (only for infrared type) Integrated AS-i chip

Accessories Connectors Mounting systems AS-i

3

43.5

18

1 Photoelectric proximity switches

70

Scanning distance 100 . . . 1500 mm

80

Scanning distance 100 . . . 1000 mm

1 2 3 4 5 6

5

Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l 5.2 mm Sensitivity adjustment

Page 13

DB W 27-2_Teil 1_en.qxp 28.06.2002 14:47 Uhr Seite 13

WT 27-2 Technical data

WT 27-2

Scanning distance

100 . . .1000 mm, adjustable 100 . . .1500 mm, adjustable

Light source 1), light type

LED, red light LED, infrared light Approx. 15 mm at 500 mm Approx. 25 mm at 800 mm

Light spot diameter

Response time 5) Max. switching frequency 6)

26.5 . . . 31.6 V DC 2) ≤ 5 VPP ≤ 30 mA ≤ 40 mA, front screen heating 2 ms 250/s

Pre-failure signalling output Alarm Test input “TE” Connection type

Plug

VDE protection class Circuit protection 7)

A, C

Supply voltage VS Ripple3) Current consumption4)

Enclosure rating AS-i profile Ambient temperature TA

IP 67 S 1.1 Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 100 g

Weight Front screen heating Housing material

ABS

1)

4)

Average service life 100,000 h at TA = + 25 °C 2) Limit values 3) May not exceed or fall short of VS tolerances

7)

Without load Signal transit time with resistive load 6) With light/dark ratio 1:1 5)

Assignment of data bits D0

Z 230 Z 210 Z 240

(Host level)

D1

Switching state Mode: light-switching Alarm

D2

NC

D3

Test function

0 Light is not received 1 Light is received 0 Active 1 Inactive 0 1 0 Sender ON 1 Sender OFF

8)

A = VS connections reverse-polarity protected C = Interference pulse suppression

Black = 16 % remission Grey = 18 % remission White = 90 % remission

Assignment of parameter bits

Input

P0*

NC

Input

P1*

Light-/dark-switching

Input

P2*

NC

Output

P3*

NC

(Host level) 0 1 0 Dark-switching 1 Light-switching 0 1 0 1

Parameter Parameter Parameter Parameter * Default setting = 1

Order information Type Part no. WT 27-2Z 230 1 015 099 WT 27-2Z 210 1 015 098 WT 27-2Z 240 1 015 137

Scanning distance 20 1

30

2

30

3

30

4

30

5

30

6

30

18

3 4 5 6

800

6%/90% 1 14

800

6%/90%

2

4 12

1200 1500

600

18%/90%

16

1000

900

1200

Scanning distance on black 8)

red light

Scanning distance on grey 8) Scanning distance on white 8) Scanning distance on black 8) Scanning distance on grey 8) Scanning distance on white 8)

red light red light infrared light infrared light infrared light

1500

5

10 % of scanning distance

0 (mm) 300 1 2

500

18%/90%

8 90%/90%

6

90%/90% 6

3

4 2 0

(mm)

300

600

900

1200

1500 SENSICK

13

Page 14

DB W 27-2_Teil 2_en.qxp 28.06.2002 14:39 Uhr Seite 14

WL 27-2 Photoelectric reflex switches, red light -- DC

24.6

53.5

2

5 17

10

Red light Front screen heating, optional Selectable time delay

43.5

1

6

3

7

50

61

70

Photoelectric reflex switches

Dimensional drawing

80

Scanning range 14 m

5.2 max. 16 5

4

40 50

Adjustments possible

5

6

<0,5 s

WL 27-2P 630 WL 27-2N 630

>0,5 s

WL 27-2F 132 WL 27-2F 440 t0 t3 t1 t2 t1+ t2

7 Sensitivity

Sensitivity

Connection types WL 27-2F 132 WL 27-2F 430 WL 27-2F 440 WL 27-2F 450

Accessories Connectors Mounting systems Reflectors

14

SENSICK

4 x 0.25 mm2

LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l 5.2 mm Time control Time delay selector switch Sensitivity adjustment t0 t4 t3+t4

1 2 3 4 5 6 7

5

4-pin, M 12

Switch-selectable time delay 0.5 – 10 s t0 Without time delay t3 ON-delay from interruption light path t4 OFF-delay from reset of light path t3 + t4 ON- and OFF-delay

0.02 – 0.5 s t0 Without time delay t1 ON-delay from interruption light path t2 OFF-delay from reset of light path t1 + t2 ON- and OFF-delay

WL 27-2F 431

WL 27-2P 630 WL 27-2N 630

WL 27-2F 730

4-pin, M 18

6-pin, Q6, DC

7-pin, Q7, DC

Page 15

DB W 27-2_Teil 2_en.qxp 28.06.2002 14:39 Uhr Seite 15

WL 27-2 Technical data

WL 27-2

F 132 F 430 F 431 F 440 F 450 P 630 F 730 N 630

Scanning range, max. typ./on reflector 14 m /PL 80 A Adjustable sensitivity Light source 1), light type Light spot diameter

LED, red light Approx. 220 mm at 10 mm

Supply voltage VS Ripple3) Current consumption4)

10 . . . 30 V DC2) ≤ 5 VPP ≤ 25 mA ≤ 35 mA, front screen heating

Output current IA max.

– PNP, Q and Q – NPN, Q and Q 100 mA

Response time5) Max. switching frequency6) Selectable delay ranges

≤ 500 µs 1000/s 0.5 . . .10 s/0.02 . . . 0.5 s

Test input “TE”, sender OFF

PNP : Test input to 0 V NPN : Test input to VS

Connection types

Cable 7), 2 m Plug

VDE protection class 8) Circuit protection 9) Enclosure rating

V

Switching outputs

A, B, C IP 67 IP 65 Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 100 g

Ambient temperature TA Weight Front screen heating Polarising filter Housing material

ABS

1)

3)

Average service life 100,000 h at TA = + 25 °C 2) Limit values

6)

May not exceed or fall short of VS tolerances 4) Without load 5) Signal transit time with resistive load

9)

With light/dark ratio 1:1 Do not bend below 0 °C 8) Reference voltage 50 V DC 7)

Order information Type Part no. WL 27-2F 132 1 015 100 WL 27-2F 430 1 013 269 WL 27-2F 431 1 015 106 WL 27-2F 440 1 015 101 WL 27-2F 450 1 015 102 WL 27-2P 630 1 015 108 WL 27-2F 730 1 015 104 WL 27-2N 630 1 015 107

Operating range and operating reserve 80

1

0.1

2

0.3

3

0.1

4

0.1

6.2

9

5

0.1

6.5

9.5

6

0.1

4.2

7

0.3 2

4.3

■

6

Reflector type

3 4

PL 50 A PL 40 A

5

PL 30 A PL 20 A Reflective tape “Diamond Grade”

6 7

10

60

■

4

50

7

2 4 6 Operating range

6

70

10 7

1 PL 80 A 2 C 110

14

1

40

8 10 12 14 Scanning range, max. typ.

Operating range 0,1. . .10,0 m 0,3 . . . 6,0 m 0,1. . . 7,0 m 0,1. . . 6,2 m 0,1. . . 6,5 m

Operating reserve

0 (m)

10

A = VS connections reverse-polarity protected – B = Output Q and Q short-circuit protected C = Interference pulse suppression

30 20

7

10

Scann. range, max. typical

0

1

3

Operating range 5

7

9

11

13

15 m

0,1. . . 4,2 m 0,3 . . . 2,0 m

SENSICK

15

Page 16

DB W 27-2_Teil 2_en.qxp 28.06.2002 14:39 Uhr Seite 16

WL 27-2 Photoelectric reflex switches, red light -- UC

24.6

53.5

2

6 7

50

61

3

5 17

10

Red light Selectable time delay

43.5

1

70

Photoelectric reflex switches

Dimensional drawing

80

Scanning range 14 m

5.2 max. 16 5

4

5

40 50

Adjustments possible WL 27-2S 132 WL 27-2R 630

WL 27-2S 730

6 light

5 dark

0,5 - 10 s t0 t1 t0 t1 t2 t2 t1+t2 t1+ t2

7 Sensitivity

Accessories Connectors Mounting systems Reflectors

Sensitivity

1 2 3 4 5

LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l 5.2 mm Time control 6 Time delay selector switch X Light-switching ● Dark-switching 7 Sensitivity adjustment Switch-selectable time delay 0.5 – 10 s t0 Without time delay t1 ON-delay from interruption of light path t2 OFF-delay from reset of light path t1 + t2 ON- and OFF-delay

Connection types WL 27-2S 132 WL 27-2R 630

WL 27-2S 730

5 x 0.25 mm2

6-pin, Q6, AC/UC

7-pin, Q7, AC/UC blk

1

1 blu blu

2

2 red red

3

3 brn brn

4

4 ora ora

5

5

6

6 blk

7

16