Page 9
DB W 27-2_Teil 1_en.qxp 28.06.2002 14:47 Uhr Seite 9
WT 27-2 Technical data
WT 27-2
Scanning distance
100 . . .1500 mm, adjustable
Light source 1), light type Light spot diameter
LED, infrared light Approx. 25 mm at 800 mm
Supply voltage VS Ripple3) Current consumption4)
10 . . . 30 V DC 2) ≤ 5 VPP ≤ 25 mA ≤ 35 mA, front screen heating
Output current IA max. Response time 5)
– PNP, Q and Q – NPN, Q and Q 100 mA 2 ms
Max. switching frequency6) Selectable delay ranges
250/s 0.5 . . .10 s/0.02 . . . 0.5 s
Test input “TE”, sender OFF
PNP : Test input to 0 V NPN : Test input to VS
Connection types
Cable 7), 2 m Plug
VDE protection class 8) Circuit protection 9) Enclosure rating
V
Switching outputs
F 112 F 410 N 410 F 411 F 440 P 410 P 610 N 610 F 710
A, B, C IP 67 IP 65 Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 100 g
Ambient temperature TA Weight Front screen heating Housing material
ABS
1)
3)
Average service life 100,000 h at TA = + 25 °C 2) Limit values
May not exceed or fall short of VS tolerances 4) Without load 5) Signal transit time with resistive load
6)
9)
With light/dark ratio 1:1 Do not bend below 0 °C 8) Reference voltage 50 V DC 7)
Order information Type Part no. WT 27-2F 112 1 015 076 WT 27-2F 410 1 013 268 WT 27-2N 410 1 016 030 WT 27-2F 411 1 015 085 WT 27-2F 440 1 015 079 WT 27-2P 410 1 015 138 WT 27-2P 610 1 015 089 WT 27-2N 610 1 015 087 WT 27-2F 710 1 015 083
Scanning distance 1
30
2
30
3
30
0 (mm)
20
800
18
1200
16
1500
300
600
900
1200
1500
14
1 Scanning distance on black, 6 % remission
12
2 Scanning distance on grey, 18 % remission
10
6%/90% 1
3 Scanning distance on white, 90 % remission
18%/90% 2
% of scanning distance
A = VS connections reverse-polarity protected – B = Output Q and Q short-circuit protected C = Interference pulse suppression
8 6 90%/90%
4
3 2 0
(mm)
300
600
900
1200
1500
SENSICK
9
Page 10
DB W 27-2_Teil 1_en.qxp 28.06.2002 14:47 Uhr Seite 10
WT 27-2 Photoelectric proximity switches, background suppression, infrared light -- UC Dimensional drawing
24.6
Photoelectric proximity switches
2
7
17
6 8 61
70
4
43.5
3
80
1
50
Infrared light Adjustable background suppression Selectable time delay
53.5
18
Scanning distance 100 . . . 1500 mm
5.2 max. 16 5
5
40 50
Adjustments possible WT 27-2S 112 WT 27-2R 610
WT 27-2S 710
6
7
8 t0 t0 t1+t2 t1+ t2 dark light t1 t2 t1 t2
0,5 – 10 s
Accessories Connectors Mounting systems
10
SENSICK
1 2 3 4 5
Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l 5.2 mm 6 Sensitivity adjustment 7 Time control 8 Time delay selector switch X Light-switching ● Dark-switching Switch-selectable time delay 0.5 – 10 s t0 Without time delay t1 OFF-delay from trailing edge of object t2 ON-delay from leading edge of object t1 + t2 OFF- and ON-delay
Connection type WT 27-2S 112
WT 27-2R 610
WT 27-2S 710
5 x 0.25 mm2
6-pin, Q6, AC/UC
7-pin, Q7, AC/UC blk blk blu blu red red brn brn ora ora
5
Page 11
DB W 27-2_Teil 1_en.qxp 28.06.2002 14:47 Uhr Seite 11
WT 27-2 Technical data
WT 27-2
Scanning distance
100 . . .1500 mm, adjustable
Light source 1), light type Light spot diameter
LED, infrared light Approx. 25 mm at 800 mm
Supply voltage VS Current consumption
24 . . . 240 V UC (+ 10 %, – 20 %) < 2 VA
Switching outputs Max. switching voltage Max. switching current Max. switching capacity Response time Max. switching frequency 3)
SPDT, isolated 2) 250 V AC / DC 120 V 4 A / 240 V AC or 24 V DC AC 1000 V A / DC 100 W < 6 ms 10/s
Delay range
0.5 . . .10 s
Connection types
Cable 4), 2 m Plug
VDE protection class 5)
V
Circuit protection 6) Enclosure rating
A, C IP 67 IP 65
Ambient temperature TA Weight Housing material
Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 100 g ABS
1)
3)
Average service life 100,000 h at TA = + 25 °C 2) Provide suitable spark suppression for inductive and capacitive loads
S 112 R 6107) S 710
6)
With light/dark ratio 1:1 Do not bend below 0 °C 5) Reference voltage 250 V AC 4)
A = VS connections reverse-polarity protected C = Interference pulse suppression
20 30
2
30
3
30
0 (mm)
800
18 1200
Relay contacts are separate from the power supply by basis insulation of 3 mm
Order information Type Part no. WT 27-2S 112 1 015 093 WT 27-2R 610 1 015 091 WT 27-2S 710 1 015 096
Scanning distance 1
7)
16 1500
300
600
900
1200
14
1500
6%/90%
12 1 Scanning distance on black, 6 % remission
1 10
2 Scanning distance on grey, 18 % remission
2 % of scanning distance
3 Scanning distance on white, 90 % remission
18%/90%
8 6 90%/90%
4
3 2 0
(mm)
300
600
900
1200
1500
SENSICK
11
Page 12
DB W 27-2_Teil 1_en.qxp 28.06.2002 14:47 Uhr Seite 12
WT 27-2 ASI Photoelectric proximity switches, background suppression, red/infrared light -- DC Dimensional drawing
24.6
53.5
2
50
5.2 max. 16 5 WT 27-2Z 210 WT 27-2Z 240
6
Connection type WT 27-2Z 230 WT 27-2Z 210 WT 27-2Z 240
4-pin, M 12
AS-i +
AS-i –
SENSICK
5
40 50
Adjustments possible WT 27-2Z 230
12
6
61
4
Red/infrared light Adjustable background suppression Front screen heating, optional (only for infrared type) Integrated AS-i chip
Accessories Connectors Mounting systems AS-i
3
43.5
18
1 Photoelectric proximity switches
70
Scanning distance 100 . . . 1500 mm
80
Scanning distance 100 . . . 1000 mm
1 2 3 4 5 6
5
Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l 5.2 mm Sensitivity adjustment
Page 13
DB W 27-2_Teil 1_en.qxp 28.06.2002 14:47 Uhr Seite 13
WT 27-2 Technical data
WT 27-2
Scanning distance
100 . . .1000 mm, adjustable 100 . . .1500 mm, adjustable
Light source 1), light type
LED, red light LED, infrared light Approx. 15 mm at 500 mm Approx. 25 mm at 800 mm
Light spot diameter
Response time 5) Max. switching frequency 6)
26.5 . . . 31.6 V DC 2) ≤ 5 VPP ≤ 30 mA ≤ 40 mA, front screen heating 2 ms 250/s
Pre-failure signalling output Alarm Test input “TE” Connection type
Plug
VDE protection class Circuit protection 7)
A, C
Supply voltage VS Ripple3) Current consumption4)
Enclosure rating AS-i profile Ambient temperature TA
IP 67 S 1.1 Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 100 g
Weight Front screen heating Housing material
ABS
1)
4)
Average service life 100,000 h at TA = + 25 °C 2) Limit values 3) May not exceed or fall short of VS tolerances
7)
Without load Signal transit time with resistive load 6) With light/dark ratio 1:1 5)
Assignment of data bits D0
Z 230 Z 210 Z 240
(Host level)
D1
Switching state Mode: light-switching Alarm
D2
NC
D3
Test function
0 Light is not received 1 Light is received 0 Active 1 Inactive 0 1 0 Sender ON 1 Sender OFF
8)
A = VS connections reverse-polarity protected C = Interference pulse suppression
Black = 16 % remission Grey = 18 % remission White = 90 % remission
Assignment of parameter bits
Input
P0*
NC
Input
P1*
Light-/dark-switching
Input
P2*
NC
Output
P3*
NC
(Host level) 0 1 0 Dark-switching 1 Light-switching 0 1 0 1
Parameter Parameter Parameter Parameter * Default setting = 1
Order information Type Part no. WT 27-2Z 230 1 015 099 WT 27-2Z 210 1 015 098 WT 27-2Z 240 1 015 137
Scanning distance 20 1
30
2
30
3
30
4
30
5
30
6
30
18
3 4 5 6
800
6%/90% 1 14
800
6%/90%
2
4 12
1200 1500
600
18%/90%
16
1000
900
1200
Scanning distance on black 8)
red light
Scanning distance on grey 8) Scanning distance on white 8) Scanning distance on black 8) Scanning distance on grey 8) Scanning distance on white 8)
red light red light infrared light infrared light infrared light
1500
5
10 % of scanning distance
0 (mm) 300 1 2
500
18%/90%
8 90%/90%
6
90%/90% 6
3
4 2 0
(mm)
300
600
900
1200
1500 SENSICK
13
Page 14
DB W 27-2_Teil 2_en.qxp 28.06.2002 14:39 Uhr Seite 14
WL 27-2 Photoelectric reflex switches, red light -- DC
24.6
53.5
2
5 17
10
Red light Front screen heating, optional Selectable time delay
43.5
1
6
3
7
50
61
70
Photoelectric reflex switches
Dimensional drawing
80
Scanning range 14 m
5.2 max. 16 5
4
40 50
Adjustments possible
5
6
<0,5 s
WL 27-2P 630 WL 27-2N 630
>0,5 s
WL 27-2F 132 WL 27-2F 440 t0 t3 t1 t2 t1+ t2
7 Sensitivity
Sensitivity
Connection types WL 27-2F 132 WL 27-2F 430 WL 27-2F 440 WL 27-2F 450
Accessories Connectors Mounting systems Reflectors
14
SENSICK
4 x 0.25 mm2
LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l 5.2 mm Time control Time delay selector switch Sensitivity adjustment t0 t4 t3+t4
1 2 3 4 5 6 7
5
4-pin, M 12
Switch-selectable time delay 0.5 – 10 s t0 Without time delay t3 ON-delay from interruption light path t4 OFF-delay from reset of light path t3 + t4 ON- and OFF-delay
0.02 – 0.5 s t0 Without time delay t1 ON-delay from interruption light path t2 OFF-delay from reset of light path t1 + t2 ON- and OFF-delay
WL 27-2F 431
WL 27-2P 630 WL 27-2N 630
WL 27-2F 730
4-pin, M 18
6-pin, Q6, DC
7-pin, Q7, DC
Page 15
DB W 27-2_Teil 2_en.qxp 28.06.2002 14:39 Uhr Seite 15
WL 27-2 Technical data
WL 27-2
F 132 F 430 F 431 F 440 F 450 P 630 F 730 N 630
Scanning range, max. typ./on reflector 14 m /PL 80 A Adjustable sensitivity Light source 1), light type Light spot diameter
LED, red light Approx. 220 mm at 10 mm
Supply voltage VS Ripple3) Current consumption4)
10 . . . 30 V DC2) ≤ 5 VPP ≤ 25 mA ≤ 35 mA, front screen heating
Output current IA max.
– PNP, Q and Q – NPN, Q and Q 100 mA
Response time5) Max. switching frequency6) Selectable delay ranges
≤ 500 µs 1000/s 0.5 . . .10 s/0.02 . . . 0.5 s
Test input “TE”, sender OFF
PNP : Test input to 0 V NPN : Test input to VS
Connection types
Cable 7), 2 m Plug
VDE protection class 8) Circuit protection 9) Enclosure rating
V
Switching outputs
A, B, C IP 67 IP 65 Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Approx. 100 g
Ambient temperature TA Weight Front screen heating Polarising filter Housing material
ABS
1)
3)
Average service life 100,000 h at TA = + 25 °C 2) Limit values
6)
May not exceed or fall short of VS tolerances 4) Without load 5) Signal transit time with resistive load
9)
With light/dark ratio 1:1 Do not bend below 0 °C 8) Reference voltage 50 V DC 7)
Order information Type Part no. WL 27-2F 132 1 015 100 WL 27-2F 430 1 013 269 WL 27-2F 431 1 015 106 WL 27-2F 440 1 015 101 WL 27-2F 450 1 015 102 WL 27-2P 630 1 015 108 WL 27-2F 730 1 015 104 WL 27-2N 630 1 015 107
Operating range and operating reserve 80
1
0.1
2
0.3
3
0.1
4
0.1
6.2
9
5
0.1
6.5
9.5
6
0.1
4.2
7
0.3 2
4.3
■
6
Reflector type
3 4
PL 50 A PL 40 A
5
PL 30 A PL 20 A Reflective tape “Diamond Grade”
6 7
10
60
■
4
50
7
2 4 6 Operating range
6
70
10 7
1 PL 80 A 2 C 110
14
1
40
8 10 12 14 Scanning range, max. typ.
Operating range 0,1. . .10,0 m 0,3 . . . 6,0 m 0,1. . . 7,0 m 0,1. . . 6,2 m 0,1. . . 6,5 m
Operating reserve
0 (m)
10
A = VS connections reverse-polarity protected – B = Output Q and Q short-circuit protected C = Interference pulse suppression
30 20
7
10
Scann. range, max. typical
0
1
3
Operating range 5
7
9
11
13
15 m
0,1. . . 4,2 m 0,3 . . . 2,0 m
SENSICK
15
Page 16
DB W 27-2_Teil 2_en.qxp 28.06.2002 14:39 Uhr Seite 16
WL 27-2 Photoelectric reflex switches, red light -- UC
24.6
53.5
2
6 7
50
61
3
5 17
10
Red light Selectable time delay
43.5
1
70
Photoelectric reflex switches
Dimensional drawing
80
Scanning range 14 m
5.2 max. 16 5
4
5
40 50
Adjustments possible WL 27-2S 132 WL 27-2R 630
WL 27-2S 730
6 light
5 dark
0,5 - 10 s t0 t1 t0 t1 t2 t2 t1+t2 t1+ t2
7 Sensitivity
Accessories Connectors Mounting systems Reflectors
Sensitivity
1 2 3 4 5
LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l 5.2 mm Time control 6 Time delay selector switch X Light-switching ● Dark-switching 7 Sensitivity adjustment Switch-selectable time delay 0.5 – 10 s t0 Without time delay t1 ON-delay from interruption of light path t2 OFF-delay from reset of light path t1 + t2 ON- and OFF-delay
Connection types WL 27-2S 132 WL 27-2R 630
WL 27-2S 730
5 x 0.25 mm2
6-pin, Q6, AC/UC
7-pin, Q7, AC/UC blk
1
1 blu blu
2
2 red red
3
3 brn brn
4
4 ora ora
5
5
6
6 blk
7
16
SENSICK