Spec sheet · Sick
W 27-2: The photoelectric switch series with expanded possibilities (Data Sheet)
Spec sheet32 pagesPDF 1.3 MB
Data sheet for the SICK W 27-2 photoelectric switch series: WT 27-2 proximity, WL 27-2 reflex and WS/WE 27-2 through-beam switches.
Names · 1 model
The models it names
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
A data sheet for the SICK W 27-2 series of photoelectric switches, built on a modular design. It covers the WT 27-2 photoelectric proximity switches with background suppression (red light, infrared and laser types, DC or UC supply), the WL 27-2 photoelectric reflex switches and the WS/WE 27-2 through-beam switches, plus AS-i versions. For each type it gives dimensional drawings, connection types and pinouts, technical data (scanning distance, supply voltage, outputs, response time, enclosure rating, temperatures), scanning distance charts and order part numbers, followed by accessories.
From the sheet
Key facts from this sheet
Each line names its page in the PDF.
This is a SICK data sheet for the W 27-2 series of photoelectric switches: WT 27-2 proximity switches with background suppression, WL 27-2 reflex switches and WS/WE 27-2 through-beam switches. It gives the technical data, connection types and order numbers of each version, plus the connectors, cables, brackets and reflectors that go with them.
- Device type
- Photoelectric switch series: WT 27-2 proximity switches with background suppression and WL 27-2 reflex switches p. 1
- Supply voltage
- 10 to 30 V DC or 24 to 240 V UC, by version; AS-i versions 26.5 to 31.6 V DC p. 1, 19
- Switching outputs
- DC versions: PNP or NPN, 100 mA max.; UC versions: isolated SPDT relay, 4 A at 240 V AC or 24 V DC p. 15, 17
- Connections
- Plug (M 12 or M 18 4-pin, Q6 6-pin, Q7 7-pin) or 2 m cable, by version p. 14, 15
- Enclosure rating
- IP 67 or IP 65 p. 15
- Scanning range
- WL27: 14 m max. typical on a PL 80 A reflector p. 15
- Scanning distance
- WT27: adjustable, 100 to 1000 mm with red light, 100 to 1500 mm with infrared, 100 to 800 mm for the laser type WT 27L-2 p. 3, 5, 9
- Operating temperature
- WL27: -40 to +60 °C; WT27: -40 to +60 °C, laser type WT 27L-2 -10 to +45 °C p. 3, 5, 15
- Time delay
- WL27: switch-selectable ON- and OFF-delay, DC versions 0.5 to 10 s or 0.02 to 0.5 s, UC versions 0.5 to 10 s p. 14, 15, 17
- AS-i versions
- WL 27-2Z 230, WL 27-2Z 240, WT 27-2Z 230, WT 27-2Z 210 and WT 27-2Z 240 have an integrated AS-i chip, AS-i profile S 1.1 p. 12, 13, 18, 19
- Reflectors
- WL27: PL 20 A (part no. 1 012 719), PL 30 A (1 002 314), PL 50 A (1 000 132); PL 40 A, PL 80 A and C 110 also listed p. 15, 31
- M 12 connectors
- 4-pin female cables DOL-1204-G02M (part no. 6 009 382), DOL-1204-G05M (6 009 866), right angle DOL-1204-W02M (6 009 383); female connectors DOS-1204-G (6 007 302), DOS-1204-W (6 007 303) p. 26, 27
- WL27 part numbers
- WL27: WL 27-2F 430 is 1 013 269, WL 27-2P 630 is 1 015 108, WL 27-2N 630 is 1 015 107, WL 27-2-R 630 is 1 015 109 p. 15, 17
What this sheet walks you through
- Setting sensitivity and the switch-selectable time delay p. 14
- Choosing a reflector for the WL 27-2 and reading its operating range p. 15
- Switching the sender off with the test input p. 15
- Connection diagrams for the UC relay versions p. 16
- Reading the WT 27-2 scanning distance on black, grey and white objects p. 5
- Assigning AS-i data and parameter bits p. 19
- Housing dimensions and mounting holes p. 14
- Ordering connectors and connecting cables p. 26, 27, 28, 29
- Mounting with bar clamps and a weather protection hood p. 30
Good to know
- Relay output versions need suitable spark suppression for inductive and capacitive loads. p. 17
- Versions with a fixed cable: do not bend the cable below 0 °C. p. 15
- Connector cables in dynamic use need a bend radius of at least 20 times the cable diameter. p. 26
- The data sheet states the WT 27L-2 laser type is laser class 2. p. 3
- Supply ripple must stay at or below 5 VPP and may not take the voltage outside its tolerances. p. 15
Questions this sheet answers
What is the range of the SICK WL27 reflex switch?
Up to 14 m typical, on a PL 80 A reflector. p. 15
What supply voltage does the WT27 photoelectric switch need?
DC versions run on 10 to 30 V DC and UC versions on 24 to 240 V UC. p. 5, 7
What is the part number of the WL 27-2F 430?
The data sheet lists part no. 1 013 269. p. 15
Which M12 connector cables are listed for the W 27-2 series?
Female M 12 4-pin cables such as DOL-1204-G02M (part no. 6 009 382) and DOL-1204-G05M (6 009 866). p. 26
The whole text · 4 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file