Spec sheet · Sick
Sick WL18 Spec Sheet
Spec sheet2 pagesPDF 214 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Two SICK catalog pages on the WL 18-2 red-light photoelectric reflex switches for DC, in PNP types WL 18-2P 132 to 2P 630 and NPN types WL 18-2N 132 to 2N 630. They give the dimensional drawing, connection types, technical data, reflector operating ranges and order information.
- Device
- Photoelectric reflex switch, red light, DC, with an autocollimation system p. 1
- Types
- WL 18-2P 132, 2P 135, 2P 430, 2P 630, 2N 132, 2N 135, 2N 430, 2N 630 p. 1
- Scanning range
- 7 m max. typical, on reflector PL 80 A p. 1, 2
- Switching outputs
- PNP or NPN, Q and Q, depending on type; output current 100 mA max. p. 2
- Response time
- < 500 µs; max. switching frequency 1000/s p. 2
- Test input TE
- PNP: sender OFF with test input to 0; NPN: sender OFF with test input to V+ p. 2
- Connection
- Cable 2 m or 5 m, or plug (4-pin M 12 or 6-pin), depending on type p. 1, 2
- Ambient temperature
- Operation -40 °C to +60 °C; storage -40 °C to +75 °C p. 2
- Weight
- Approx. 100 g p. 2
- Housing
- ABS, acrylonitrile butadiene styrene p. 2
- Adjustment
- LED signal strength indicator, sensitivity adjustment and alignment sight p. 1
- Features
- No mutual interference when installed opposite each other; insensitive to ambient light sources such as HF lamps p. 1
What this sheet walks you through
- Mounting dimensions and adjustment points p. 1
- Operating range for each reflector type p. 2
- Ordering a WL 18-2 type p. 2
Good to know
- The cable must not be bent below 0 °C. p. 2
Questions this sheet answers
What temperature range does the WL18 operate in?
-40 °C to +60 °C in operation; storage is -40 °C to +75 °C. p. 2
How do I switch off the WL 18-2 sender for a test?
Use the test input TE: on PNP types connect it to 0, on NPN types to V+. p. 2
How fast does the WL 18-2 respond?
Response time is under 500 µs, with a maximum switching frequency of 1000/s. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
WL 18-2 Photoelectric reflex switches, red light -- DC Dimensional drawing
17
Photoelectric reflex switches
32.5 5677514 6.3 4.1 3max. 14 4
(HF lamps, flashing alarm lamps)
- No mutual interference if devices are installed opposite each other
- Operating temperature -- 40 °C . . . + 60 °C
- Fast response time
- Test input for system diagnosis, optional
- Autocollimation system
55
- Insensitive to ambient light sources
30.32422 30
Adjustments possible WL 18-2P 132 WL 18-2P 135 WL 18-2P 430
WL 18-2N 132 WL 18-2N 135 WL 18-2N 430 WL 18-2N 630
1 2 3 4 5
Centre of optical axis LED signal strength indicator Mounting hole l 4.1 mm Sensitivity adjustment Alignment sight
4
C V
Connection types WL 18-2P 132 WL 18-2P 430
WL 18-2P 630WL 18-2P 135WL 18-2N 430WL 18-2N 6304-pin, M 126-pin
WL 18-2N 132 WL 18-2N 135
Accessories Cable receptacles Mounting brackets
page 496 510Reflectors5205 x 0.25 mm2 redbrn11grablk44orawht25blublu32trq6 3182SENSICK CATALOGUE33.3Scanning range 7m
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
WL 27-2 Technical dataWL 18-2WL 18-2
P 132 P 135 P 430 P 630 N 132 N 135 N 430 N 630
Scanning range, max. typ./on reflector Sensitivity Light source 1), light type Light spot diameter Supply voltage VS Ripple 3) Current consumption 4) Switching outputs
7 m/PL 80 A adjustable LED, red light 40 mm at 2 m 10 . . . 30 V DC2) ≤ 5 VSS < 25 mA – PNP, Q and Q – NPN, Q and Q Output current IA max. 100 mA PNP; signal voltage HIGH VS – (< 2.9 V) PNP; signal voltage LOW Approx. 0 V NPN; signal voltage HIGH Approx. VS NPN; signal voltage LOW < 1.5 V Response time 5)/Max. switching freq.6) < 500 µs; 1000/s Test input ”TE” PNP, sender OFF Test input to 0 NPN, sender OFF Test input to V+ Connection types Cable 7), 2 m Cable 7), 5 m Plug VDE protection class 8) V Circuit protection 9) A, B, C Enclosure rating IP 67 IP 65 Ambient temperature TA Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Weight Approx. 100 g Polarising filter Housing material ABS, acrylonitrile butadiene styrene 4) Without load 5) Signal transit time with resistive load 6) With light/dark ratio 1:1 7) Do not bend below 0 °C 8) Reference voltage 50 V DC
1) Average service life 100,000 h at TA = + 25 °C 2) Limit values 3) May not exceed or fall short of VS tolerances
9) A = VS connections reverse-polarity protected – B = Output Q and Q short-circuit protected C = Interference pulse suppression
Order information Type Part no. 1 012 906 WL 18-2P 132
Scanning range and operating reserve 100 1 0
52 03 44 06.635 02.56 0216.6 3.8310212■ Operating range34
range,
- Scanning max. typical
Reflector typeOperating range1PL 80 A C 110
0 . . . 5.0 m 0 . . . 3.0 m
PL 50 PL 40 A PL 30 A PL 20 A Reflective tape Diamond Grade
0 . . . 4.0 m 0 . . . 3.0 m 0 . . . 2.5 m 0 . . . 2.0 m 0 . . .1.0 m
5
1 012 908
WL 18-2P 630 WL 18-2N 132
1 012 912 1 012 903
WL 18-2N 135 WL 18-2N 630
1 012 911 1 012 904WL 18-2N 4301 016 205
5 Scanning distance, max. typical
71 (m)1 012 907WL 18-2P 430Operating distance1.7Operating reserve10 (m)2 3 4 5 6 7WL 18-2P 1355.53 07 071234567SENSICK CATALOGUE183