Two SICK catalog pages on the WL 18-2 red-light photoelectric reflex switches for DC, in PNP types WL 18-2P 132 to 2P 630 and NPN types WL 18-2N 132 to 2N 630. They give the dimensional drawing, connection types, technical data, reflector operating ranges and order information.

Device
Photoelectric reflex switch, red light, DC, with an autocollimation system p. 1
Types
WL 18-2P 132, 2P 135, 2P 430, 2P 630, 2N 132, 2N 135, 2N 430, 2N 630 p. 1
Scanning range
7 m max. typical, on reflector PL 80 A p. 1, 2
Switching outputs
PNP or NPN, Q and Q, depending on type; output current 100 mA max. p. 2
Response time
< 500 µs; max. switching frequency 1000/s p. 2
Test input TE
PNP: sender OFF with test input to 0; NPN: sender OFF with test input to V+ p. 2
Connection
Cable 2 m or 5 m, or plug (4-pin M 12 or 6-pin), depending on type p. 1, 2
Ambient temperature
Operation -40 °C to +60 °C; storage -40 °C to +75 °C p. 2
Weight
Approx. 100 g p. 2
Housing
ABS, acrylonitrile butadiene styrene p. 2
Adjustment
LED signal strength indicator, sensitivity adjustment and alignment sight p. 1
Features
No mutual interference when installed opposite each other; insensitive to ambient light sources such as HF lamps p. 1

What this sheet walks you through

  • Mounting dimensions and adjustment points p. 1
  • Operating range for each reflector type p. 2
  • Ordering a WL 18-2 type p. 2

Good to know

  • The cable must not be bent below 0 °C. p. 2

Questions this sheet answers

What is the scanning range of the SICK WL 18-2?

7 m maximum typical, on a PL 80 A reflector. p. 1, 2

What temperature range does the WL18 operate in?

-40 °C to +60 °C in operation; storage is -40 °C to +75 °C. p. 2

How do I switch off the WL 18-2 sender for a test?

Use the test input TE: on PNP types connect it to 0, on NPN types to V+. p. 2

How fast does the WL 18-2 respond?

Response time is under 500 µs, with a maximum switching frequency of 1000/s. p. 2

The file

Size and text

Pages2
PDF214 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Sick WL18 Spec Sheet

The text of page 1, from the PDF itself

WL 18-2 Photoelectric reflex switches, red light -- DC Dimensional drawing

17

Photoelectric reflex switches

32.5 5677514 6.3 4.1 3max. 14 4

(HF lamps, flashing alarm lamps)

  • No mutual interference if devices are installed opposite each other
  • Operating temperature -- 40 °C . . . + 60 °C
  • Fast response time
  • Test input for system diagnosis, optional
  • Autocollimation system

55

  • Insensitive to ambient light sources

30.32422 30

Adjustments possible WL 18-2P 132 WL 18-2P 135 WL 18-2P 430

WL 18-2N 132 WL 18-2N 135 WL 18-2N 430 WL 18-2N 630

1 2 3 4 5

Centre of optical axis LED signal strength indicator Mounting hole l 4.1 mm Sensitivity adjustment Alignment sight

4

C V

Connection types WL 18-2P 132 WL 18-2P 430

WL 18-2P 630WL 18-2P 135WL 18-2N 430WL 18-2N 6304-pin, M 126-pin

WL 18-2N 132 WL 18-2N 135

Accessories Cable receptacles Mounting brackets

page 496 510Reflectors5205 x 0.25 mm2 redbrn11grablk44orawht25blublu32trq6 3182SENSICK CATALOGUE33.3Scanning range 7m

Page 2 of Sick WL18 Spec Sheet

The text of page 2, from the PDF itself

WL 27-2 Technical dataWL 18-2WL 18-2

P 132 P 135 P 430 P 630 N 132 N 135 N 430 N 630

Scanning range, max. typ./on reflector Sensitivity Light source 1), light type Light spot diameter Supply voltage VS Ripple 3) Current consumption 4) Switching outputs

7 m/PL 80 A adjustable LED, red light 40 mm at 2 m 10 . . . 30 V DC2) ≤ 5 VSS < 25 mA – PNP, Q and Q – NPN, Q and Q Output current IA max. 100 mA PNP; signal voltage HIGH VS – (< 2.9 V) PNP; signal voltage LOW Approx. 0 V NPN; signal voltage HIGH Approx. VS NPN; signal voltage LOW < 1.5 V Response time 5)/Max. switching freq.6) < 500 µs; 1000/s Test input ”TE” PNP, sender OFF Test input to 0 NPN, sender OFF Test input to V+ Connection types Cable 7), 2 m Cable 7), 5 m Plug VDE protection class 8) V Circuit protection 9) A, B, C Enclosure rating IP 67 IP 65 Ambient temperature TA Operation – 40 °C . . . + 60 °C Storage – 40 °C . . . + 75 °C Weight Approx. 100 g Polarising filter Housing material ABS, acrylonitrile butadiene styrene 4) Without load 5) Signal transit time with resistive load 6) With light/dark ratio 1:1 7) Do not bend below 0 °C 8) Reference voltage 50 V DC

1) Average service life 100,000 h at TA = + 25 °C 2) Limit values 3) May not exceed or fall short of VS tolerances

9) A = VS connections reverse-polarity protected – B = Output Q and Q short-circuit protected C = Interference pulse suppression

Order information Type Part no. 1 012 906 WL 18-2P 132

Scanning range and operating reserve 100 1 0

52 03 44 06.635 02.56 0216.6 3.8310212■ Operating range34

range,

  • Scanning max. typical

Reflector typeOperating range1PL 80 A C 110

0 . . . 5.0 m 0 . . . 3.0 m

PL 50 PL 40 A PL 30 A PL 20 A Reflective tape Diamond Grade

0 . . . 4.0 m 0 . . . 3.0 m 0 . . . 2.5 m 0 . . . 2.0 m 0 . . .1.0 m

5

1 012 908

WL 18-2P 630 WL 18-2N 132

1 012 912 1 012 903

WL 18-2N 135 WL 18-2N 630

1 012 911 1 012 904WL 18-2N 4301 016 205

5 Scanning distance, max. typical

71 (m)1 012 907WL 18-2P 430Operating distance1.7Operating reserve10 (m)2 3 4 5 6 7WL 18-2P 1355.53 07 071234567SENSICK CATALOGUE183