Page 7

Functionality of Molex Interface (J3)

1

+24 V DC RxD (RS 232)

The 24 V DC version of the PS 52 (PS 52-0000) has a 2-position terminal of DC input. The input is polarity independent for ease of wiring.

TxD (RS 232)

This connector is an extension of the terminal block. It's intended use is to provide extra connectivity without consuming the terminal block connections.

GND OUTPUT 1 OUTPUT 2 OUTPUT 3 SENSOR 2 9

SENSOR 1

+ -

9 1 www.sickoptic.com

5

800•325•7425

Page 8

CLV 410, 412, 414 Standard Configuration

1

To PC running CLV Setup Software for programming CLV or To Host Device for data transmission (PC, computer, etc.)

1

7 021 851 7 021 849

800•325•7425

2 m Interface Cable 3 m Interface Cable

6 www.sickoptic.com

Page 9

CLV 21X, 220 Standard Configuration

To PC running CLV Setup Software for programming CLV

1

CLV 21X, 220 1

To Host Device for data transmission (PC, computer, etc.)

1

7 021 851 7 021 849 www.sickoptic.com

2 m Interface Cable 3 m Interface Cable

7

800•325•7425

Page 10 read from a scan by OCR; it may hold reading errors

Dimensional Drawings

Dimensions in mm (in)

| 118 | r (4.53 }

(a4 SICK

Oo Oo me (335) wees pli: |

1.13 Hed, - i PA curbing Bole Cire ee) o a o = Ta Bey (a0) (233) H 1a | i (4.08) |

Figure 6

800*325*7425 SICK www.sickoptic.com

Page 11

Technical Specifications PS 52 POWER SUPPLY Input Voltage

115 V AC / 230 V AC 60/50 Hz

Output Voltage

24 V DC ±20%

Max. Power Output

350 mA

Enclosure Material

Polycarbonate

Enclosure Rating

NEMA 12 (pending), FCC Class A Part 15 compliance, CE compliant

Transformer Rating

UL, CSA

Dimensions (L x W x H)

115 x 90 x 80 mm (4.53 x 3.54 x 3.15 in)

Weight

0.64 kg (1.40 lb)

Operating Temperature

0…70° C (32…158° F)

Relative Humidity

90% non-condensing

Mounting

One side, 4 holes, 4.76 mm (.19 in) diameter

Power Cord Length

1.83 m (6 ft)

Figure 7 www.sickoptic.com

9

800•325•7425

Page 12

Industrial Automation Products for North America and the World. S a l e s

•

S e r v i c e

•

S u p p o r t

For more information and application assistance, please call:

800-325-7425 Visit us on the World Wide Web:

www.sickoptic.com Email:

info@sickoptic.com

SICK, INC. • 6900 WEST 110TH STREET • BLOOMINGTON MN 55438 USA PHONE (952) 941-6780 • FAX (952) 941-9287 7 022 644.0006