The text of a manual · part 1 of 8
Technical Description: Proximity Laser Scanner PLS, pages 1 to 10
Pages 1 to 10 of 78
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick PLS101
Page 1
T E C H N I C A L
D E S C R I P T I O N
PLS_TB_Titel_en_KV1_0.qxd 09.07.2004 10:35 Uhr Seite 1
Proximity Laser Scanner PLS
Page 2
This document is protected by the law of copyright, whereby all rights established therein remain with the company SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Alteration or abridgement of the document is not permitted without the explicit written approval of the company SICK AG.
ESPE 17LL
2
8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
PLS_TB_GB_06_05_02_M844.pmd
2
08.07.2004, 15:54
Page 3
Table of Contents 0 General Safety Notes and Protective Measures ....................... 4 1 Approval and Certificates .................................................................... 5 2 Notices / Regulation Use ..................................................................... 6
9.11 Interrogate fault memory (system diagnosis) ................................................................... 57 Initial fault diagnosis ................................................................ 57 Interrogate PLS fault memory .............................................. 57 10 Checks ...................................................................................................... 59
3 How the PLS Works ................................................................................ 7 Principle of function .................................................................... 7 Fields and measuring range of the PLS ............................. 8 4 Fields of Application - What the PLS Can Do .............................. 9 Area protection ............................................................................. 9 Internal space protection ......................................................... 9 Vehicle protection and navigation ....................................... 10 Measurement of contours ..................................................... 10 5 Location planning .................................................................................. 11 5.1
5.2
5.3
Range of the PLS ....................................................................... 11 Stationary protection with PLS ............................................ 12 Important notes on configuration ....................................... 12 Location planning ...................................................................... 13 Restart definition ........................................................................ 16 Mounting recommendations for PLS ................................. 16 Mobile protection with PLS ................................................... 19 Location planning ..................................................................... 20 Calculation of the necessary protective fields ............. 21 Configuration examples ........................................................ 22 If you use several PLS units ................................................ 23
10.1 Check PLS ................................................................................... 59 10.2 Check list ..................................................................................... 60 11 Care and Maintenance ....................................................................... 61 11.1 SICK Service / Hotline ............................................................ 61 11.2 LEDs on the PLS ...................................................................... 62 11.3 PLS fault table ........................................................................... 63 11.4 Service questionnaire ............................................................ 65 12 Appendix ................................................................................................... 67 12.1 Characteristics ........................................................................... 67 12.2 Accessories ................................................................................ 68 Mounting kits .............................................................................. 68 Connection set .......................................................................... 68 Interface cables ........................................................................ 68 Documentation and PLS / LSI user software ................ 68 Other SICK accessories ........................................................ 68 And also ....................................................................................... 68 12.3 Technical data ........................................................................... 69 12.4 Standards and regulations ................................................... 74 12.5 Notes on non-certified PLS types ..................................... 75 13 Glossary .................................................................................................... 77
6 Supply Package ..................................................................................... 24 Recommended accessories ................................................ 24 Connection set .......................................................................... 24 Interface cable ........................................................................... 24 7 Mounting the PLS ................................................................................. 25
This technical description contains all the information necessary for project planning and setting up the PLS. You will find in it the information you need for mechanical mounting, electrical installation and programming of the PLS.
8 Connecting the PLS ............................................................................. 28 Connecting the power connector ...................................... 29 Connection examples ............................................................. 29 Notes about the connection examples ........................... 33 Connecting the interface connector ................................. 34 Short-term connection to a PC ........................................... 35 Permanent connection to an evaluation computer .... 35 9 Programming the PLS with the User Software ........................ 36 9.1
Installing the user software ................................................. 36 System requirements ............................................................. 36 9.2 What to do ................................................................................... 37 Essential steps ........................................................................... 37 Other options .............................................................................. 37 9.3 Starting: the initial configuration ........................................ 38 Configure hardware ................................................................. 39 Send configuration to PLS .................................................... 42 Edit monitoring range .............................................................. 43 Send monitoring range to PLS ............................................ 46 9.4 Edit / dimension fields ............................................................ 47 Convert fields .............................................................................. 47 Change scale of segmented field ....................................... 47 Copy and paste fields ............................................................. 48 Save individual fields ............................................................... 48 Fix co-ordinates ......................................................................... 48 9.5 Teach-in protective field ....................................................... 49 9.6 Monitor protective field .......................................................... 51 9.7 Check settings .......................................................................... 52 9.8 Receive and store configuration ....................................... 53 9.9 Change password .................................................................... 54 9.10 Change screen view ............................................................... 55
The description covers the following PLS types: – PLS 101-312 (certified for personal protection to IEC/EN 61496-1) – PLS 201-313 (non certified) To avoid confusion between the certified and non-certified types, the main part of this technical description relates only to the certified types. You can find the relevant information on the non-certified types in condensed form in the Appendix in Chapter 12.5. Along with the technical description, you are also provided with an instruction manual containing important information for dayto-day use of the PLS. Keep the technical description and instruction manual readily to hand at all times. The information given in this description can be altered and amended without prior notice. Essential chapters you should read: General safety notes ..................................... Chapter 0 Important notes ............................................... Chapter 2 Location planning ............................................ Chapter 5 Supply / package Mounting and connecting up the PLS .... Chapters 6 to 8 Getting to know the user software .......... Sections 9.1 to 9.3 Checks ................................................................. Chapter 10 Technical data .................................................. Section 12.3
8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
PLS_TB_GB_06_05_02_M844.pmd
3
08.07.2004, 15:54
3
Page 4
0
General Safety Notes and Protective Measures
Safety regulations and notes 1. The use/installation of proximity scanners used as noncontact protective devices, as well as the recurrent technical checks, are covered by national/international legal regulations, in particular
• • • •
Machine Directive 98/37 EU, Use of Work Materials Directive 89/655 EEC, the safety regulations and the accident prevention and safety regulations.
Manufacturers and operators of machinery equipped with our protective systems are responsible for consulting with the relevant authorities about, and complying with, all the applicable safety regulations. 2. Furthermore, our instructions, particularly with regards to the check regulations (see Chapter 10 “Checks”) detailed in this technical description or instruction manual (e.g. concerning the use, extension, installation or integration in the machine controller), must be heeded and complied with without fail. 3. The checks must be carried out by skilled or authorised and instructed personnel, and are to be documented in a clear and comprehensible manner. 4. Our operating instructions are to be made available to the employee (operator) using the machinery equipped with our protective systems. The employee is to be instructed in their use by skilled personnel. 5. A check list for manufacturer and outfitter checks is supplied as an enclosure to this brochure.
4
8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
PLS_TB_GB_06_05_02_M844.pmd
4
08.07.2004, 15:54
Page 5
1
Declaration of Conformity
Note: Additional certification by Underwriters Laboratories Inc. (UL) as per UL 1998 and CSA C22.2 Number 0.8-M 1996.
8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
PLS_TB_GB_06_05_02_M844.pmd
5
08.07.2004, 15:54
5
Page 6
2
Notices / Regulation Use
The PLS proximity laser scanner is a device designed to protect people and property. It is intended to monitor hazardous areas in enclosed spaces. PLS is not designed for outdoor use. Observe the instructions relating to regulation use. SICK cannot be held liable for damage arising from use of the PLS other than stipulated.
• • •
•
• • • •
•
•
•
• •
6
Install the PLS in a dry location and protect the unit against dirt and damage. Lay all wires and connecting cables such that they are protected against damage. Avoid the creation of strong electrical fields which could, for example, arise in the immediate vicinity of welding or induction cables, or which could also be caused by mobile telephones being used nearby. Make sure that no obstacles in the monitoring range can obstruct the field of vision of the PLS or cause shadows. Such shadow areas cannot be monitored by the PLS. Where there are unavoidable areas of shadow, check whether they present any risk. Take additional precautionary measures as necessary. Keep the monitoring range free of smoke, fog, steam and other air pollution. The functioning of the PLS may otherwise be impaired and error shutdowns may occur. Avoid placing strongly reflective objects such as retroreflectors in the scanning plane of the PLS, as they may influence its measurement results. Mount the PLS so that it cannot be dazzled by sunlight. Also avoid stroboscopic and fluorescent lamps, as they may influence the PLS under certain circumstances. In mounting, installation and use of the PLS, observe the standards and regulations applicable in your country. The Appendix presents a summary of the most important regulations. For programming of the monitoring range, take note of the description of the user software as from Chapter 9. This describes how to connect the PLS to a PC and how to work with the user software. Before releasing the machine for use, test whether access to the hazard area is fully covered by the safety devices. After release, also check at regular intervals (such as every morning before beginning work) that the PLS is activated properly when an infringement of the protective field occurs. This test should be carried out along all protective field limits, in accordance with application-specific regulations. If you want to deploy one or more PLS together with an LSI (Laser Scanner Interface) in your application, to work with several different switchable or variable protective fields for example, please also take note of the technical description of the LSI. If you employ the PLS for vehicle protection: please note that the PLS can only be used on electrically driven vehicles. The PLS must be disposed of in a proper and environmentally friendly manner at the end of its useful service life.
8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
PLS_TB_GB_06_05_02_M844.pmd
6
08.07.2004, 15:54
Page 7
3
How the PLS Works
Principle of function The PLS is an optical sensor which scans its surroundings with infrared laser beams. It is used to monitor a hazardous area on a machine or vehicle. The PLS can be used on manually controlled- vehicles, such as narrow-aisle forklifts and other lift trucks, as well as in driverless transport systems (DTS) such as shunting cars and free-navigating vehicles. As a result of its scanning principle, the PLS requires neither separate receivers nor reflectors. This has the following advantages: – You can adapt the monitoring range precisely to the hazardous area of a machine. – Since you do not need not need any receivers or additional reflectors, you keep the entire-area freely accessible and driveable. – If the hazardous area changes, you can alter the sensor simply by- reprogramming the software, with no additional mounting. – Different reflective materials do not influence the functioning of the sensor. This makes the PLS highly versatile in its uses.
∆t
S
E
0 t
S
0
E
S t s ~∆t
The sensor operates on the principle of reflex light time measurement. It emits very short light pulses. At the same time an “electronic stopwatch” runs. If the light encounters an object, it is reflected and thrown back to the sensor. From the time between sending and receiving, the sensor calculates its distance from the object. In the sensor there is also a uniformly rotating mirror, which deflects the light pulses so that they sweep a semicircular area. By determining the mirror angle, the PLS detects in which direction the object is located. The sensor determines its precise position from the measured distance and the direction of the object.
8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
PLS_TB_GB_06_05_02_M844.pmd
7
08.07.2004, 15:54
7
Page 8
Fields and measuring range of the PLS The monitoring range of the sensor consists of a protective field and a warning field. You can use the applied software to define the two fields and store them in the memory. The protective field protects the hazardous area of a machine or vehicle. As soon as the sensor detects an object in the protective field, it deactivates the safety outputs, thereby switching off the machinery or stopping the vehicle. This is a safety function. Its safety integrity corresponds to Cat. 3 as per EN 954-1: The test basis is Type 3 as per EN 61496-1
'Viewed' area (e.g. plant wall)
measuring length warning field protective field
You can define the warning field such that the sensor detects on object before it enters the actual hazardous area, and triggers an alarm signal, for example. Independent of its evaluation of the protective and warning fields, the sensor continually scans its surroundings for additional measuring tasks, such as to navigate a DTS or measure contours.
8
4 m max. protected area approx 15 m max. warning field range
8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
PLS_TB_GB_06_05_02_M844.pmd
8
08.07.2004, 15:54
Page 9
4
Fields of Application – What the PLS Can Do
These pages provide an overview of the key fields of applica-tion of the PLS. Area protection On hazardous stationary machinery the PLS ensures that the machine (or only its hazardous environment) is shut down as soon as someone enters the hazardous area. This is done by means of a protective field ➊ which you can define according to your needs and store in the PLS. You can also define a warning field ➋ in front of the actual hazardous area which triggers an alarm signal as soon as someone approaches the hazardous area. The person can then move out of the warning area without the machine or its hazardous movement having to be stopped. This helps you to safeguard continuous production.
Host r Powpely Sup
➀ ➁
Internal space protection Where internal spaces exist in large machines, the PLS ensures that the machine can only start up when the internal space is clear. This is important especially with regard to internal spaces which are not clearly visible, or not visible at all, from the outside. In this application the PLS performs only a secondary protective function. The actual personal protection is provided by a light grid, whilst the PLS monitors restarting of the machine.
8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
PLS_TB_GB_06_05_02_M844.pmd
9
08.07.2004, 15:54
9
Page 10
Vehicle protection and navigation You can employ the PLS on vehicles, such as driverless transport systems (DTS), forklifts and shunting cars, to safeguard a vehicle's path – on its way through a factory hall for example. The protective field ➊ of the PLS ensures that the protective semiconductor outputs (OSSDs) are deactivated, thereby stopping the vehicle if a person or obstacle is standing in the way. You can also define a warning field ➋ which, for example, triggers an alarm signal some distance before the person or obstacle is reached and cuts the speed of the vehicle. You can protect both manually controlled vehicles and driverless transport systems (DTS).
➀ ➁ ➂
Independent of the protective and warning field settings, the PLS continually monitors the positions of objects in its surroundings ➌. Vehicles with an internal navigation system can use this ambient data to update their system. For this, the PLS is permanently linked to the on-board computer of the PLS. The data transmitted by the PLS is encoded in telegrams. The telegram description can be ordered from SICK.
Measurement of contours You can use the measurement principle of the PLS for a wide variety of measuring tasks, such as: – Size measurement of goods – Position detection of goods (e.g. pallets) – Cross-section measurement in aisles and tunnels – Profile measurement of goods or vehicles – Position measuring of goods on shelves – Filling level measurement – Length measurement If you want solutions for measurement problems of this kind, please order documentation from our LMS laser scanner series, which is suitable for such tasks.
10
Y
H
B X
8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
PLS_TB_GB_06_05_02_M844.pmd
10
08.07.2004, 15:54