Page 21

Operating Instructions

Installation

Chapter 4

OTS400

4

Installation

4.1 Installation sequence •

Mount the frame above the reading location (if not already installed)

•

Mount the bar code scanners

•

Align and adjust the bar code scanners with the objects and range in which bar codes can appear

•

Mount the sensor for generating the reading pulse (if a reading interval signal is not already provided)

•

Install OTS400/ OTC400

4.2 Preparations for installation 4.2.1 • •

Hinged bracket (no. 2018435) or basic mounting bracket (no. 2013824) with the enclosed screws 2 screws for fixing each bar code scanner to the frame (if already provided)

4.2.2 • • • • • • • •

Required components to be mounted

OTS400/ OTC400 CLV bar code scanners Reflection photoelectric switch for external reading interval control Connector covers with EEPROM Connecting cables Terminating resistor Hinged bracket or mounting bracket Frame (if not already provided)

4.2.3 • • •

Required accessories

Required tools

Tool Measuring tape (max. required length 3,000 mm) Protractor

4.2.4

Procedure for mounting the bar code scanners

The procedure for mounting bar code scanners is described in detail in Chapter 4 Installation in the Operating Instructions of the bar code scanner in question.

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

4-1

Page 22

Chapter 4

Installation

Operating Instructions OTS400 Omni Tracking System

4.3 Mounting the OPS 4.3.1

Mounting the OTS400/ OTC400

1

Install the frame and the bar code scanners.

2

Install the OTS400/ OTC400. The OTS400/OTC400 is attached near the CLVs. See Section 3.4 Maximum cable lengths. The OTS400/ OTC400 must be mounted in such a way that the open device can be accessed at any time.

Mounting holes are provided on the OTS400/OTC400 or OTC400 (stand-alone) for securing the devices. See 11.2 Dimensional drawings OTS400/ OTC400. 4.3.2

Mounting the external reading pulse sensor

See Chapter 4 Installation in the Operating Instructions of the bar code scanner in question. 4.3.3

Mounting sensors for detecting the object distance

The CLV490 bar code scanner, which is mainly used in the OPS, is equipped with an autofocus function for detecting the object distance automatically. For this reason, sensors for detecting the object distance are usually unnecessary. If you want to use sensors for detecting the object, nevertheless, proceed as described in Chapter 4 Installation for the bar code scanner in question.

4.4 Disassembling the OPS 1. 2. 3. 4.

Switch off the operating voltage. Disconnect all cables Remove the bar code scanners and OTS400/ OTC400 from the mounting device Remove the frame if necessary

For information on environmentally-friendly disposal, please refer to Section 9.3 Disposal.

4-2

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 23

Electrical installation

Operating Instructions

Chapter 5

OTS400

5

Electrical installation

5.1 Installation sequence •

Connect the bar code scanners to the OTS400/ OTC400

•

Connect the data and function interfaces of the OTS400/ OTC400

•

Connect the PC to the OTS400/ OTC400

•

Connect the OTS400 or OTC400 to the operating voltage

5.2 Electrical connections and cables The power supply for the OTS400 is connected via the screw terminals (top left in the OTS400, see Fig. 3-2 on page 3-4). Terminal specifications: Connection cable

Cross section

Rigid

0.2 ... 4 mm2

Flexible

0.2 ... 4 mm2

Table 5-1: Power supply connection cable for OTS400

PVC cables are suitable for all connections. Neither heat protection nor halogen-free cables are required. The load carrying capacity of each terminal is 30 A. The OTC400 can also be used separately (without an OTS400). In this case, a functional extra-low voltage of 24 V DC +20%/–10% % pursuant to IEC 364-4-41 is required. The functional extra-low voltage can be generated by using a safety transfomer pursuant IEC 742. The is voltage wired directly on the terminal strip on the front panel. Specification of the connection terminal: Connection cable

Cross section

Rigid

0.2 ... 2.5 mm2

Flexible

0.2 ... 2.5 mm2

Table 5-2: Power supply connection cable for OTC400

Furthermore, the following connections can be made using the terminals on the front panel: •

RS 232 or RS 422/485 host interface (connection to the host)

•

CAN Bus/CANOpen connection for communication with the bar code scanners

•

Power supply for the bar code scanners

•

Four switching outputs

•

A relay switching output

•

Three trigger inputs for external reading pulse triggers

•

Two travel increment inputs for external incremental encoders

•

Seven sensor inputs (“Sensor 1-1 ... 1-7”) that can be freely defined (e.g. for height photoelectric switches)

•

Four sensor inputs (“Sensor 2-1 ... 2-4”) that can be freely defined (e.g. for height photoelectric switches)

•

An "AUX" connection (9-pin D Sub HD connector) for test/diagnosis and parameter purposes

•

A "CAN" connection (9-pin D Sub HD socket) for test and diagnosis purposes

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

5-1

Page 24

Chapter 5

Electrical installation

Operating Instructions OTS400 Omni Tracking System

¾

All connections, with the exception of the relay switching output must be wired with copper leads with a minimum wire cross-section of 0.125 mm2!

¾

Connections for the relay switching output at least 1 mm2.

5.3 Connector pin assignment 5.3.1

"CAN" connection

Pin

Signal

Function

2

CAN L

CAN Bus (IN/OUT)

3

GND

Ground

CAN H

CAN Bus (IN/OUT)

1

4 5 6 7 8 9 Table 5-3: Pin assignment of the 9-pole D Sub socket "CAN"

5.3.2

"AUX" connection

Pin

Signal

Function

1

T+ (RS 422/485)

Host interface (RS 422/485)

2

RxD_T

Aux interface (RS 232)

3

TxT_T

Aux interface (RS 232)

4

R+ (RS 422/485)

Host interface (RS 422/485)

5

GND

Ground

6

T- (RS 422/485), TxD (RS 232)

Host interface (RS 422/485)

7

RTS_T

Aux interface (RS 232)

8

CTS_T

Aux interface (RS 232)

9

R- (RS 422/485), RxD (RS 232)

Host interface (RS 422/485)

Tab. 5-4: Pin assignment of the 9-pole D Sub "AUX" plug

5-2

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 25

Electrical installation

Operating Instructions

Chapter 5

OTS400

CAN interface

Aux interface

Fig. 5-1: OTC400 - front view

In addition to the 9-pin connectors of the auxiliary interface, the individual connections for the host and auxiliary interface (AUX) are available in two connector strips. See Fig. 5-1.

5.4 Preparations for electrical installation 5.4.1

Requirements of the host interface

The host interface of the OTS400/OTC400 can be operated as an RS 422/485 or RS 232 interface. Table 5-3 shows the recommended maximum cable length, in accordance with the data transmission rate. Interface type

Transmission rate

Distance to host

RS 232

Up to 19,200 bd max. 10m

38,400 bd max. 3m max. 38,400 bd max. 1200 m

1)

RS 422/485

1) with appropriate line termination

Table 5-5: Maximum cable length between the OTS400 and host

Alternatively, bus connection modules can be used, see Chapter 3 Product description. 5.4.2

Supply voltage

The OTS400 with OTC400 requires an operating voltage of 230 V AC (115 V AC) –15%/+10% with protective grounding. In stand-alone operation (without the OTS400), the OTC400 requires an operating voltage of 24 V DC –10%/+20% (functional extra-low voltage pursuant to IEC 364-4-41). For connecting the power supply to the OTS400, see Fig. 3-2. For connecting the power supply to the OTC400 in stand-alone operation at the 24 V IN connector strip, see Fig. 5-1.

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

5-3

Page 26

Electrical installation

Chapter 5

Operating Instructions OTS400 Omni Tracking System

5.5 Electrical installation 5.5.1

Connecting the bar code scanners

Photoelectric switch No. 6021166

CAN Bus / CAN Open Protocol

OTS Host connection

OTC CLV490

CLV490

CLV490

Incremental encoder Fig. 5-2: Wiring diagram

Cable no. 6021166 is available for connecting the first bar code scanner to the OTS400/ OTC400. A socket is provided for connection to the bar code scanner; open cable heads are available for the connection to the OTC400.

Recommendation: the supply cable should be shortened as much as possible, in order to prevent unnecessary transmission losses. Pin

Signal

Color

Connection OTC400

1

Shield

2

+24 V

Red

+24 V

3

GND

Black

0V

4

CAN_H

White

H

5

CAN_L

Blue

L

Shield*)

*) with the OTS400, apply the shield directly over the conduit thread (housing entry).

Table 5-6: Pin assignment of the connection cables

For connecting the cables, see Fig. 5-3.

5-4

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 27

Electrical installation

Operating Instructions

Chapter 5

OTS400

Danger of irreparable damage to the OTC400 When operating the OTC400 as a stand-alone device: ¾ The power supply for the bar code readers may only be supplied at the 24V and 0V terminals in the CAN field. The correct currents are only available at these terminals.

Abb. 5-3: Ansicht OTC400

4: CAN H 5: CAN L 3: GND 2: +24V 1: Shield

Plug-in jumpers

Fig. 5-3: OTC400 - front view

The cables for connecting the individual bar code scanners are available in 3 different lengths: Order No.

Length

Article

6021166

5m

Supply cable (1x open end/ 1x socket)

6021175

10 m

Supply cable (1x open end/ 1x socket)

6021164

0.7 m

Cable (1x connector/ 1x socket)

6021165

3m

Cable (1x connector/ 1x socket)

6021168

5m

Cable (1x connector/ 1x socket)

6021293

10 m

Return cable (1x connector/ 1x open end)

Table 5-7: Length of cables

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

5-5

Page 28

Chapter 5

Electrical installation

Operating Instructions OTS400 Omni Tracking System

The connector cover with EEPROM parameter memory (no. 2021264) should be attached between the connection cables and the bar code scanner. The operating principle of the connector cover is described in detail in the CLV490 Operating Instructions. The basic design is shown in Fig. 5-4. The last bar code scanner is provided with a terminating resistor (no. 6021167). This is also pluggable. A maximum of 2 branch lines per OTS400/ OTC400 are possible.

Fig. 5-4: CLV490 bar code scanner with connector cover and connection cables

5.5.1

Connecting the incremental encoder

An incremental encoder is to assign the bar codes to the various objects and must be connected directly to the OTC400. The terminal INC 1 is provided for this purpose. The plug-in jumper "0V – OV 3" is used to connect the frame potential of the incremental encoders with the frame potential of the OTC400 (top position of the plug-in jumper), if the latter is to be powered via the OTC400. The terminal strip below the INC 1 terminal is used to connect the power supply. Otherwise, the external potential should be assigned to the incremental encoder (bottom position of the plug-in jumper). A dual-channel incremental encoder can also be connected if necessary. The OTC400 then evaluates the two phase-shifted signals. Switching behavior:

Provision of an incremental signal at a distance of 10 to 15 mm per increment. Between 4 and 5 increments should be always available for the smallest object gap. See Fig. 5-5.

Characteristics:

Opto-decoupled, non-interchangeable

Electrical values:

Low: –10V ≤ Vi ≤ +10V; –3mA ≤ Ii ≤ +3mA High: –30V ≤ Vi ≤ –15V; –10mA ≤ Ii ≤ –5mA High: +30V ≤ Vi ≤ +15V; +10mA ≤ Ii ≤ +5mA

Table 5-8: Characteristic data of the "incremental encoder" input

5-6

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 29

Operating Instructions

Electrical installation

Chapter 5

OTS400

5.5.2

Connecting the reading pulse sensor

The TRIGGER 1 terminal is provided for connecting the reading pulse sensor. The plug-in jumper "0V – OV 1" is used to connect the ground potential of the reading pulse sensor with the ground potential of the OTC400 (top position of the plug-in jumper), if the latter is to be powered via the OTC400. The terminal strip below the TRIGGER terminal is used to connect the power supply. Otherwise, the external potential should be assigned to the reading pulse sensor (bottom position of the plug-in jumper). A 2nd and 3rd reading pulse sensor (TRIGGER 2 or 3) can also be connected, with power supply and assigned ground potential (plug-in jumper "0V – 0V2"). Switching behavior:

Start reading interval when input is live (default: active high, de-bouncing: standard). For connection diagram, see Fig. 5-5.

Characteristics:

Opto-decoupled, non-interchangeable

Electrical values:

Low: –10V ≤ Vi ≤ +10V; –3mA ≤ Ii ≤ +3mA High: –30V ≤ Vi ≤ –15V; –10mA ≤ Ii ≤ –5mA High: +30V ≤ Vi ≤ +15V; +10mA ≤ Ii ≤ +5mA

Table 5-9: Characteristic data of the "TRIGGER 1, 2, and 3" inputs

5.5.3

Connecting sensors

Additional sensors can be connected if necessary. The SENSOR 1 (1-1 ...1-7) and SENSOR 2 (2-1 ... 2-4) terminal strips are provided for this purpose. A plug-in jumper (0V – 0V4) is also available for SENSOR 1. At present, the switching function is not defined and can be configured by the customer. Switching function:

Undefined. See Fig. 5-5.

Characteristics:

Opto-decoupled, non-interchangeable

Electrical values:

Low: –10V ≤ Vi ≤ +10V; –3mA ≤ Ii ≤ +3mA High: –30V ≤ Vi ≤ –15V; –10mA ≤ Ii ≤ –5mA High: +30V ≤ Vi ≤ +15V; +10mA ≤ Ii ≤ +5mA

Table 5-10: Characteristic data of the "SENSOR" inputs

Fig. 5-5: Input circuits

The GND shown in Fig. 5-5 is the external GND. To connect this to the internal GND, change the jumper setting.

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

5-7

Page 30

Electrical installation

Chapter 5

Operating Instructions OTS400 Omni Tracking System

5.5.4

Connecting the outputs

The 4 switching outputs and the relay output can be assigned various result functions, independent of one another. If the associated event occurs during the read operation, the corresponding output becomes live at the end of the reading pulse for the selected pulse duration. Switching outputs: The 4 outputs have the same characteristic data. Switching behavior:

Switches with respect to the supply voltage VS and ground

Characteristics:

Short-circuit-proof, temperature-protected, not electrically isolated from Vs

Function assignment (defaults)

Output 1: "Device ready" (static), output 2: "Good read", output 3: "No read", Output 4: "Data pulse", pulse duration 100ms

Electrical values:

0V ≤ Vo ≤ Vs Io ≤ 100mA

Guaranteed: Vo ≥ Vs –2.5V for Io ≤ 100mA

Table 5-11: Characteristic data of the 4 switching outputs

1)

Vs Short circuit monitor

Temperature monitor

Fig. 5-6: Circuit diagram of the 4 switching outputs (Here: output 1 in detail)

Relay output:

Characteristics:

Not short-circuit-proof, not temperature-protected, electrically isolated, floating

Function setting (defaults) Relay output: "Device ready" (static) Electrical values:

Alternating voltage/direct voltage 0V ≤ VSWITCH ≤ 250V according to VDE 0110 group C Max. current 1.5 A for 24 V DC Max. current 0.2 A for 250 V DC Max. current 1.5 A for 250 V AC

Table 5-12: Characteristic data of the relay output

5-8

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30