Page 11
Operating Instructions
Safety information
Chapter 2
OTS400
2.4 Quick stop and quick restart 2.4.1 Switching off the OTS400 ¾
Switch off the operating voltage at the mains switch.
¾
If the OTC400 is installed without the OTS400, the operating voltage for the OTC400 must be disconnected.
This will result in the loss of (at the most): • The application-specific parameter block if it was only stored temporarily in the OTS400/OTC400 or in the bar code scanners • The last reading result • Daily operating hours counter of the individual the bar code scanners and the OTC400 (operating hours counter, number of reading intervals, number of good reads, maximum time of the reading interval, minimum time of the reading interval, average identification quality) 2.4.2
Switching on the OTS400 again
¾
Switch on the operating voltage at the mains switch.
¾
If the OTC400 is installed without an OTS400, switch on the operating voltage for the OTC400 again. The OTS400 and the connected bar code scanners resume operation with the parameter set that was last stored permanently and reset the daily operating data.
2.5 Environmental information The OTS400/ OTC400 is designed to minimize the impact on the environment. It neither contains nor emits any substances that are harmful to the environment. 2.5.1
Power consumption
The power consumption of the device is low and mainly depends on the number of bar code scanners that are operated in the OPS. The typical power consumption of an OTS400 with one CLV 490 bar code scanner is 30 VA and, with 8 CLV 490 bar code scanners, 130 VA. 2.5.2
Disposal after removal from service
Unusable or irreparable devices should be disposed of in an environmentally-friendly manner in line with the applicable national waste disposal regulations. The OTS400/OTC400 can be separated into reusable secondary raw materials (housing) and problem waste (boards as electronic scrap). See Section 9.3 Disposal. At present, SICK AG does not accept any devices that can no longer be used or repaired.
8008869/RA61/2007-07-30
© SICK AG · Auto Ident · Germany · All rights reserved
2-3
Page 12
Chapter 2
Safety information
Operating Instructions OTS400 Omni Tracking System
Notes:
2-4
© SICK AG · Auto Ident · Germany · All rights reserved
8008869/RA61/2007-07-30
Page 13
Operating Instructions
Product description
Chapter 3
OTS400
3
Product description
3.1 Design 3.1.1
Scope of delivery
The OTS400 Omni Tracking System is supplied with: •
An information sheet (notes on device, yellow)
• A CD-ROM “Manuals & Software Bar Code Scanners“ (no. 2029112) with – “CLV-Setup“ programm for WindowsTM (version V4.4 or higher) and the “CLV-Setup Help“ online help system (HTML files) – “CLV-Connect“ PC software (HTML files showing terminal diagrams) – OTS400 Operating Instructions in English and German as PDF edition as well as additional publications (connections modules, other SICK bar code scanners) – freely available “Acrobat Reader“ PC software for reading PDF files *) All versions lower than V4.4 are not longer valid for the OTS400/ OTC400. SICK does not deliver any longer the versions lower than V4.4. Note: The latest versions of all current publications/programs on the CD-ROM can also be downloaded from www.sick.com. Chapter 12 SICK Accessories provides an overview of mounting accessories, connection modules, cables, and connector covers. 3.1.2
Variants
The OTS400 Omni Tracking System is currently available in the following variants: Order no
Type
Description
1017867
OTS400-0000
OTS400 Omni Tracking System with RS 232/ RS 422/485 host interface
*
OTS400-1000
OTS400 Omni Tracking System with bus interface module for Profibus-DP
*
OTS400-2000
OTS400 Omni Tracking System with bus interface module for Interbus-S
*
OTS400-3000
OTS400 Omni Tracking System with bus interface module for Device Net
*
OTS400-x100
OTS400 Omni Tracking System with display
* Available on request
Table 3-1: OTS400 variants
The OTC400 Omni Tracking Controller is currently available with the following variants: Order no
Type
Description
1017866
OTC400-0000
OTC400 Omni Tracking Controller without display
*
OTC400-1000
OTC400 Omni Tracking Controller with display
* Available on request
Table 3-2: OTC400 variants
8008869/RA61/2007-07-30
© SICK AG · Auto Ident · Germany · All rights reserved
3-1
Page 14
Chapter 3
Product description
Operating Instructions OTS400 Omni Tracking System
3.1.3
System requirements
1. Requirements for mounting and starting up the OTS400 with OTC400: •
An operating voltage of 230 V AC (115 V AC) –15%/ +10% with protective grounding. The power consumption depends on the number of bar code scanners connected. The typical power consumption with one CLV490 bar code scanner is 30 VA. The typical power consumption with 8 CLV490 bar code scanners is 130 VA.
Risk of irreparable damage to the power supply unit The power supply is equipped with a switch that is set to an operating voltage of 230 V AC at the factory. If set to 115V AC but operated at 230 V AC, the power supply unit may be damaged irreparably. ¾ Never operate the OTS400 at 230 V AC if the power supply unit is set to 115 V AC.
2. Requirements for mounting and starting up the OTC400: •
An operating voltage of 24V DC –10%/ +20% (functional extra-low voltage according to IEC 364-4-41). The power consumption depends on the number of bar code scanners connected. The typical power consumption with one CLV490 bar code scanner is 20 W. The typical power consumption with 8 CLV490 bar code scanners is 120 W. The operating voltage supplied must be protected by electrical separation according to IEC 742.
3. Requirements for mounting and starting up the OTS400 with OTC400, or the OTC400: •
A suitable sensor, e.g. a reflection photoelectric switch, to signal the presence of an object with a bar code, if an external reading pulse is supplied via the "Trigger 1“,"Trigger 2“, or "Trigger 3“ terminal
•
An external incremental encoder for connecting to the "INC 1" or "INC 2" terminal for internal object assignment. The incremental signal should be resolved every 10 ... 15 mm. A minimum of 4 clock pulses should be transmitted, however, in the smallest possible gap between the objects.
•
A connection to the required host interface (RS 232, RS 422/485) for the OTS400-0000 or the OTC400-0000; or a connection to the required bus interface module (OTS400-1000/-2000/-3000).
4. Requirements for accessing the auxiliary interface of the OTC400: •
A PC with the Windows-based "CLV Setup“ program, version 4.4 or higher (can be run on Windows 95TM/98 TM or Windows NTTM, Windows 2000TM or Windows XPTM) and a serial port (port "COM x“)
•
An RS 232 data connection cable with two 9-pole D Sub sockets, e.g. no. 2014054. Pin 2 (RxD) and pin 3 (TxD) are crossed in each case.
3-2
© SICK AG · Auto Ident · Germany · All rights reserved
8008869/RA61/2007-07-30
Page 15
Operating Instructions
Product description
Chapter 3
OTS400
3.1.4
Design
Mounting hole, ∅ 8.5 mm (3 x top, 3 x bottom)
Fig. 3-1: OTS400 (outside view)
8008869/RA61/2007-07-30
© SICK AG · Auto Ident · Germany · All rights reserved
3-3
Page 16
Chapter 3
Product description
Operating Instructions OTS400 Omni Tracking System
Main switch
Connection for operating voltage (customer)
OTC400
Fig. 3-2: OTS400 (inside view)
3-4
© SICK AG · Auto Ident · Germany · All rights reserved
8008869/RA61/2007-07-30
Page 17
Operating Instructions
Product description
Chapter 3
OTS400
CAN interface
Aux interface (AUX)
Fig. 3-3: OTC400 (front view)
3.2 Operating principle The OTS400 Omni Tracking System combines the information supplied by the individual bar code scanners on the code content, and (in the case of line scanners with oscillating mirror) code angle, assignment of the bar code to the object etc., and transfers this bar code information for each object to the host, together with any required additional information. The OTS400 also powers the bar code scanners and photoelectric switches required in the OPS. The OTS400 and OTC400 communicate using the CAN Bus/ CAN Open protocol. The OTS400/ OTC400 provides each bar code scanner with the beginning and the end of an object, which is assigned a fixed number. The current travel increment is continuously communicated to each bar code scanner. If the bar code scanner detects a bar code, it sends this information immediately to the OTS400/ OTC400. The OTS400/ OTC400 then combines the results from the individual bar code scanners and sends these to the host at a defined output point. The individual bar code scanners are also monitored by the OTC400 for possible system errors. In this way, the OTS400/OTC400 can notify the host, and therefore the plant operator, if maintenance is required.
8008869/RA61/2007-07-30
© SICK AG · Auto Ident · Germany · All rights reserved
3-5
Page 18
Product description
Chapter 3
Operating Instructions OTS400 Omni Tracking System
3.3 Indicators and control elements The OTS400/ OTC400 operates with a total of 26 LEDs. The device is operated (operating mode selection) and parameterized using the Windows-based "CLV Setup" PC software or alternatively using command strings. See Section 8.3 Setting parameters with CLV Setup. 3.3.1
Functions of the LEDs
The LEDs are located on the front of the OTC400 and have the following functions: Indicator
Color
Function
Device ready green
Indicates that the OTS400/ OTC400 is ready in reading mode: lights up after the device has been switched on if the automatic self-test was performed successfully. Extinguishes when a different operating mode/function is selected.
Read result yellow
In reading mode: Lights up after a successful read (good read) Lights up if the match code comparison is activated and the bar code read matches the specified match code(s) Always lights up until the start of the next reading pulse
Data yellow
Blinks while the OTS400/ OTC400 is transmitting data to the host on the serial interface in reading mode
Output (4x)
yellow
Lights up when active
Output relay (1x)
yellow
Lights up when active
Input trigger (3x)
green/ red*)
Lights up when active, trigger 1: internal or external ground, Trigger 2 and 3: internal or external ground
Input INC (2x)
green/ red*)
Lights up when active, internal or external ground
Input Sensor 1 (7x)
*)
green/ red
Lights up when active, internal or external ground
Input Sensor 2 (4x)
green/ red*)
Lights up when active, internal or external ground
Input 24V (1x)
green
Lights up when active
Input CAN (1x)
green
Blinks while data is being exchanged between the OTS400/OTC400 and the bar code scanners on the CAN Bus.
*) red if interchanged
Table 3-3: Functions of the LEDs
3-6
© SICK AG · Auto Ident · Germany · All rights reserved
8008869/RA61/2007-07-30
Page 19
Product description
Operating Instructions
Chapter 3
OTS400
3.4 Maximum cable lengths Due to voltage losses on the cables connecting the bar code scanners, the overall cable length is limited in accordance with the number of scanners connected on each branch line. A maximum of 2 branch lines are allowed for each OTS400/OTC400. The maximum cable lengths are based on the cables provided by SICK AG. See the following tables. 3.4.1 Maximum cable lengths for an OTS400 The power supply unit in the OTS400 is set to 26 V at the factory. The cable lengths are as follows: Number of scanners per branch line
Maximum cable length
2
70 m
3
50 m
4
36 m
5
28 m
6
24 m
7
20 m
8
18 m
9
16 m
10
14 m
11
13 m
12
12 m
Table 3-4: Max. cable length for OTS400
8008869/RA61/2007-07-30
© SICK AG · Auto Ident · Germany · All rights reserved
3-7
Page 20
Product description
Chapter 3
Operating Instructions OTS400 Omni Tracking System
3.4.2 Maximum cable lengths for an OTC400 If the OTC400 is used as a stand-alone device (without OTS400), the maximum cable length depends on the supply voltage. The values in the following table are based on typical supply voltages of 24 V DC and 21.6 V DC (24 V DC minus 10%). Maximum cable lengths for other voltages are available on request. Number of scanners per branch line
Maximum cable length for DC 24 V
Maximum cable length for DC 21.6 V (DC 24 V minus 10%)
2
50 m
34 m
3
36 m
22 m
4
28 m
16 m
5
22 m
13 m
6
18 m
11 m
7
15 m
-
8
13 m
-
9
12 m
-
10
11 m
-
11
10 m
-
12
-
-
Table 3-5: Max. cable length for OTC400
3.4.3 Maximum transmission rates The transmission rate on the data transmission cables between the OTS400/ OTC400 and bar code scanners depends on the cable lengths: Cable length transmission rate
Up to 40m
1 Mbit/s
> 40m
500 kbit/s
Table 3-6: Max. transmission rate
3-8
© SICK AG · Auto Ident · Germany · All rights reserved
8008869/RA61/2007-07-30