Spec sheet · Sick
Sick NT8 Spec Sheet
Spec sheet2 pagesPDF 212 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
This is a two-page SICK catalog sheet for the NT 8 contrast scanner, with a white light source. It gives the dimensions, adjustments, connections, technical data and order numbers for types NT 8-01412 and NT 8-02412.
- Device
- Contrast scanner with white light, selectable light or dark switching and adjustable switching threshold p. 1
- Scanning distance
- 9 mm ± 2 mm from the front edge of the lens p. 1, 2
- Light spot
- 1.5 x 3.5 mm p. 2
- Light source
- White incandescent lamp, average service life 10,000 h at +25 °C p. 2
- Supply voltage
- 10 to 30 V DC, ripple under 2 V, under 50 mA without load p. 2
- Lamp supply
- 4.5 V ± 10 %, 840 mA p. 2
- Output
- NPN, HIGH = VS, LOW under 2 V; 200 mA; light or dark switching p. 2
- Speed
- 50 µs response time; 10 kHz maximum switching frequency p. 2
- Connections
- 2 m cable with 6-pin plug + PE, or 2 m cable without plug p. 1, 2
- Part numbers
- NT 8-01412: 1 005 981; NT 8-02412: 1 005 985 p. 2
- Enclosure
- IP 67, cast metal housing, 300 g p. 2
- Temperature
- Operation -10 °C to +50 °C; storage -25 °C to +85 °C p. 2
- Circuit protection
- Reverse-polarity protected supply, short-circuit protected output, interference pulse suppression p. 2
- Mounting
- M 5 threaded mounting hole, 5.5 mm deep p. 1
What this sheet walks you through
Good to know
- The cable must not be bent below 0 °C. p. 2
- Supply ripple must stay within the supply voltage tolerances. p. 2
Questions this sheet answers
What is the scanning distance of the SICK NT 8?
9 mm, within ± 2 mm, measured from the front edge of the lens. p. 1, 2
What voltage does the NT 8 contrast scanner need?
10 to 30 V DC for the sensor; the lamp runs on 4.5 V ± 10 % at 840 mA. p. 2
What is the part number of the NT 8-01412?
1 005 981. The NT 8-02412 is 1 005 985. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Lichtschranken Baureihe WL 27-2 NT 8 Contrast scanners Dimensional drawing
Scanning distance 9 mm764.556Contrast scanners 6.528
- Light- or dark-switching selectable
2130■ White light source 4■ Rapid response times123
- Adjustable switching threshold 18.5
58.538.6 5 11281006051.5
Adjustments possible NT 8-01412
1 2NT 8-024123 4 5 6 798 9
Cover for adjuster M 5 threaded mounting hole, 5.5 mm deep Dry cartridge with sight glass, can be replaced by Item 4 Lens, can be replaced by Item 3 2 m cable with 6-pin plug + PE 2 m cable Control for switching threshold ”Light-/dark-switching” selector switch Function signal indicator
78C V
Connection types NT 8-01412 NT 8-02412
Accessories
page
Cable receptacles Cable Lens
496 509 556
2 x 0.5 mm2 2 x 0.14 mm2 1 x 0.14 mm2 sheathed
Cable + 6-pin plug + PE
redL+2whtQ1blkM6grnL+lamp4Mlamp5 3414SENSICK CATALOGUE15.56200020002L+ Q M L+lamp Mlamp PE
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
NT 8 Technical data Scanning distance from front edge of lens Light
NT 89 mm ± 2 mm 1.5 x 3.5 mm
Light source 1), light type Light spot direction
Incandescent lamp, white Longitudinal Transverse
Supply voltage VS Ripple 3) Current consumption 4)
10 . . . 30 V DC 2) <2V < 50 mA
Supply voltage for lamp Current consumption for lamp
4.5 V ± 10 % 840 mA
Switching outputs
Light-/dark-switching, selectable NPN: HIGH = VS / LOW = < 2 V 200 mA 50 µs 10 kHz
Output current lA max. Response time 5) Max. switching frequency 6)
01412 02412
Connection types
Cable 7) with 6-pin plug + PE Cable 7) without plug
VDE protection class 8) Enclosure rating Circuit protection 9)
V
Ambient temperature TA Shock load Weight Housing material
Operation – 10 °C . . . + 50 °C Storage – 25 °C . . . + 85 °C To IEC 68 300 g Cast metal
1) Average service life 10,000 h at TA = + 25 °C 2) Limit values
3) May not exceed or fall short of VS tolerances 4) Without load
IP 67 A, B, C
9) A = VS connections reverse-polarity protected B = Output Q short-circuit protected C = Interference pulse suppression
5) Signal transit time with resistive load 6) With light/dark ratio 1:1 7) Do not bend below 0 °C 8) Reference voltage 50 V DC
Order informationScanning distanceTypePart no.NT 8-014121 005 981NT 8-024121 005 985100 1Operating reserve101 (mm) 11 Scanning distance10100 9 mmSENSICK CATALOGUE415