For the Sick DME2000

Page 1

DME distance measuring devices/distance sensors

Distance sensors Proximity mode

Distance sensors Reflector mode

DME 2000/DME 3000: Precise non-contact distance determination Two versions are available. The DME 2000 measures distances of up to 130 metres and, in proximity mode (i.e. without reflector), up to 2 metres. The DME 3000 has a scanning range of 500 metres – distances of up to ten metres can be measured in the proximity version.

Serial interfaces permit external further processing of the measur-

I be connected to warehouse con- distance measuring devices are trol circuits via the SSI interface.

components that are subject to wear, such as rotary transducers. They allow high-bay stackers, cranes, lift cabins or automated guided vehicle systems to be positioned with precision. The visible red light of the Class 2 laser sender facilitates alignment and handling. Adjustment and adaptation to individual automation tasks can be carried out quickly and easily by means of programming buttons on the device, an eight-digit display and the user-friendly menu-driven dialogue.

SENSICK CATALOGUE is also possible and the DME can

In handling systems, DME the perfect alternative to control

450 ed values. Interfacing to Profibus

Page 2

DME v Crane monitoring with DME: The distance measuring device triggers the emergency stop when a minimum distance is undershot.

v Non-wearing, precise and flexible: A DME 3000 sensor used for v Positioning high-bay stackers with the DME 3000 distance positioning a rail-mounted rack-serving unit with millimetre precision;

measuring device.

mechanical switches are no longer required, new docking points can be set quickly without any assembly requirements.

v DME process information: The weight of a coil can be v A DME distance measuring device used to detect drill holes as determined from its diameter.

part of inspection/quality control.

SENSICK CATALOGUE

451

Page 3

DME 2000 Distance measuring devices Measurement range 100 . . . 2047 mm

Dimensional drawing 35 12 2

M6 25.2

28

Measurement range 0,1 . . . 130 m Distance measuring devices

28.5

127.5

5 3

94

105

4

69 59

1

M4

Adjustments possible DME 2000-000

6

40 1 2 3 4

4

9

6

76

69.5

5 6

Centre of optical axis M 6 threaded mounting hole, 10 mm deep M 4 threaded mounting hole, 14 mm deep (this side only) 8-digit alphanumeric indicator Programming switches M 4 threaded mounting hole, 6 mm deep

4

5

Connection type DME 2000-000

C V 12-pin, M 16 Laser class 2

Accessories Cable receptacles page 496

Mounting brackets Link mountings

510 510

Reflectors Special accessories

520 556

Dust covers Cooling plates Remote positioning tubes

452

SENSICK CATALOGUE

5

35 and reproducibility thanks to timeof-flight measurement ■ Simple adjustment using visible red light ■ Freely programmable parameters -- 2 switching outputs -- pre-failure signalling output -- plausibility control ■ RS 232 serial interface ■ Analogue output

138

54

78

■ Excellent measurement accuracy wht

A brn

B grn

C yel

D gra

E pnk

F red

G blk

H vio

I gra/pnk

K red/blu

L blu

M

DTR

Data terminal ready (RS 232 output)

Q1

Q1 switching output

CTS

Clear to send (RS 232 input)

QA

QA analogue output

QS

QS service output

QP

QP plausibility output

L+

+ 18 . . . 30 V DC VS

RXD

R x D (receive data, RS 232 input)

S&H

Blanking input

TXD

T x D (send data, RS 232 output)

Q2

Q2 switching output

M

0 V (earth)

Page 4

DME 2000 Technical Data Light source1), light type Laser category Supply voltage VS Ripple Power consumption Switching outputs Q1, Q2, QP, QS Output voltage Output current IA Q1 and Q2 switching outputs Switching limit Switching hysteresis QP plausibility output QS service output Blanking input S/H

Analogue output Connection type VDE protection class 5) Circuit protection 6) Enclosure rating Ambient temperature TA Weight Shock load Serial interface Temperature drift 1) Average service life 50,000 h at TA = +25 °C

Measurement range 7) Resolution Light spot dimensions Effect of compressed air Effect of air temperature Measured value output cycle Target remission Max. running speed Reproducibility 8) Statistical error 1 σ Statistical error 3 σ 9)

DME 2000-

000

Laser diode, red light 2 (IEC 825-1 /EN 60825-1) 18 . . . 30 V DC 2) < 5 VSS3) < 6 W 4) PNP HIGH = VS – ≤ 2 V/LOW = 2 V 100 mA Reversible Adjustable in 1 mm increments Adjustable in 2mm increments, 0 . . . 254 mm HIGH: measurement correct/ LOW: measurement error HIGH: device has no faults/ LOW: pre-failure signalling output HIGH: ≥ 10 V; ≤ VS/ LOW: ≤ 2 V or unswitched; HIGH: Measured value stored/ LOW: free-running 0 . . . 20 mA or 4 . . . 20 mA Plug

V A, B, C IP 65 (IEC 529) Operation – 10 °C . . . + 45 °C Storage – 25 °C . . . + 75 °C Approx. 980 g To IEC 68 RS 232 (4.8/9.6, 19.2 kBaud) Type 0.4 mm/K 2) Limit values 3) May not exceed or fall short of VS tolerances

4) Without load 5) Reference voltage 50 V DC

6) A = VS connections reverse-polarity protected B = Output Q reverse-polarity protected C = Interference pulse suppression

Mode 1.1: Proximity mode

Mode 2.1: Reflector mode

Order information

100. . . 2047 mm 1 mm Approx. 3 mm/2 m

0.1. . .130 m 1 mm Approx. 250 mm/130 m 0.3 ppm/mbar 1 ppm/K 100 ms Reflective tape 3 m/s 2 mm 3 . . .130 m APM reflective tape 3 . . .100 m Diamond Grade 0.1. . . 90 m reflective tape 7610 0.1. . . 40 m reflective tape 3290 + 5/– 20 mm In range as below reproducibility stated

Standard type

Part no.

DME 2000-000

1 010 578

29 ms > 6 . . . < 36000 % 1 mm (= 90 % remission) 3 mm (> 18 % remission) 25 mm (> 6 % remission) Typical 1 mm; max. 2 mm

Accuracy 10)

± 5 mm (= 90 % remission) ± 11 mm (> 18 % remission) ± 65 mm (> 6 % remission)

7) Relative to front edge of object 8) Environmental conditions constant at 30 min. minimum switching period 9) Measurement distance 1 m, 90 % remission

10) 20 °C ambient temperature, 1013 mbar, 30 min. switching period, re-calibration recommended after 25,000 h

SENSICK CATALOGUE

453

Page 5

DME 3000-1 Distance measuring devices Measurement range up to 500 m

Dimensional drawing 35 12 2 28

Distance measuring devices

138

54 28.5

127.5

5 3

94

105

4

69 59

1

5

76 M4

6

69.5 Adjustments possible DME 3000-111 DME 3000-111P DME 3000-311

40 1 2 3 4

4

9

6

35

78 reproducibility thanks to time-of-flight measurement ■ Simple adjustment using visible red light ■ Easy handling due to programmable parameters -- 2 switching outputs -- pre-failure signalling output -- plausibility control ■ RS 422 serial interface and SSI interface ■ Profibus ■ Gateway to Interbus, DeviceNet

M6 25.2

■ Excellent measurement accuracy and

5 6

Centre of optical axis M 6 threaded mounting hole, 10 mm deep M 4 threaded mounting hole, 14 mm deep (this side only) 8-digit alphanumeric signal indicator Programming switches M 4 threaded mounting hole, 6 mm deep

4

5

Connection types DME 3000-111

DME 3000-111P

DME 3000-311 C B

C V

A Adapter not incuded in delivery 12-pin, M 16

Laser class 2

Accessories Cable receptacles Mounting brackets page 496 510

Link mountings

510

Reflectors Special accessories Dust covers Cooling plates Remote positioning tube

520 556 wht

A brn

B grn

C gra pnk red blk gra/pnk red/blu blu

454

SENSICK CATALOGUE

4-pin, M 12 Send data TX+ ( SSI: data + )

Q1

RX+ Receive data ( SSI: Clock + ) D NC E QS F QP G L+ H Receive data RX - ( SSI: Clock – ) I NC K TX - Send data ( SSI: data – ) L Q2 M M

5-pin, M 12 A

1 2 3 4

5-pin, M 12

5V

Q2 cable A

M

M

Q1

C

B

L+ cable B Shield

1 2 3 4 5

NC cable A NC cable B Shield

Page 6

DME 3000-1 Technical Data

DME 3000-

Light spot diameter Resolution

0.1. . . 500 m1), depending on reflector, see below ± 5 mm Depending on measurement range, see below 1 m (measurement distance 500 m) 0.125 mm

Light source 5), light type Laser category Supply voltage VS Ripple Power consumption

Laser diode, red light 2 (IEC 825-1/EN 60825-1) 18 . . . 30 V DC 6) < 5 VSS7) ≤ 6 W 8)

Switching outputs Q1, Q2, Q P, Q S Output current IA max. Q1 and Q2 switching outputs Switching limit/switching hysteresis QP plausibility output

PNP/NPN HIGH = VS – < 2 V/LOW = < 2 V 100 mA – Reversible Q /Q Adjustable HIGH: measurement correct / LOW: measurement error HIGH: OK / LOW: pre-failure signalling output

Measurement range Accuracy 2) 3) Reproducibility 4)

QS service output

Connection type VDE protection class 9) Circuit protection 10) Enclosure rating Ambient temperature TA Weight Interfaces Serial interface Profibus Effect of compressed air Effect of air temperature Temperature drift

111

311

111P

Plug

V A, B, C IP 65 Operation – 10 °C . . . + 45 °C Storage – 25 °C . . . + 75 °C Approx. 980 g SSI: GRIS/BINARY adjust., 24 or 25 bits RS 422: 4.8/9.6/19.2/38.4 kBaud Max. 12 MBaud 0,3 ppm / hPa 1 ppm /K Typical 0.4 mm/K Typical 0.2 mm/K

Measured value output SSI/Profibus RS 422, 38.4 kBaud Initialisation period Max. running speed

1.5 ms 18 ms 6s 6 m/s

1) Relative to front edge of object 2) 23 °C air temperature, 977 hPa, min switching period 30 min 3) Re-calibration recommended after 25,000 h

4) Environmental conditions constant, min. switching period 30 min. 5) Average service life 100,000 h at TA = +25 °C 6) Limit values

7) May not exceed or fall short of VS tolerances 8) Without load 9) Reference voltage 50 V DC

0.5 mm

2 mm

Order information

Measurement range Reproducibility Statistical error 1 σ (switching period min. 30 min, environmental conditions constant) Measurement range with reflector Reflective tape 3290 Reflective tape 7610 Reflective tape «Diamond Grade» Reflective tape APM Multi-reflector PL 240 F Multi-reflector PL 560 F Multi-reflector PL 880 F

10) A = VS connections reverse-polarity protected B = Output Q short-circuit protected C = Interference pulse suppression

Type DME 3000-111

Part no. 1 013 110

DME 3000-311

1 016 283 1 018 063

DME 3000-111P 0.1 m . . . 20 m 0.1 m . . . 40 m 2.0 m . . . 70 m 2.0 m . . . 90 m 0.1 m . . . 250 m 0.1 m . . . 270 m 10 m . . . 300 m

0.1 m . . . 40 m 0.1 m . . . 90 m 0.5 m . . . 250 m 1.0 m . . . 200 m 0.1 m . . . 300 m 0.1 m . . . 350 m 8.0 m . . . 500 m SENSICK CATALOGUE

455

Page 7

DME 3000-2 Distance measuring devices Measurement range up to 10 m

Dimensional drawing 35 12 2

M6 25.2

28

Distance measuring devices

■ Excellent measurement accuracy and

138

54 28.5

127.5

5 3

94

105

4

69 59

1

5

76 M4

6

69.5 Adjustments possible DME 3000-232 DME 3000-211 DME 3000-212 DME 3000-211P

40 1 2 3 4

4

9

6

35

78 reproducibility thanks to time-of-flight measurement ■ Simple adjustment using visible red light ■ Easy handling due to programmable parameters -- 2 switching outputs -- pre-failure signalling output -- plausibility control ■ RS 422 serial interface and SSI interface ■ Profibus ■ Gateway to Interbus, DeviceNet

5 6

Centre of optical axis M 6 threaded mounting hole, 10 mm deep M 4 threaded mounting hole, 14 mm deep (this side only) 8-digit alphanumeric indicator Programming switches M 4 threaded mounting hole, 6 mm deep

4

5

Connection types DME 3000-211

DME 3000-211P

DME 3000-212 DME 3000-232

C B

C V

A Adapter not incuded in delivery 12-pin, M 16

Laser class 2, 3 B

Accessories Cable receptacles Mounting brackets page 496 510

Link mountings Special accessories

510 556

Dust covers Cooling plates Remote positioning tubes wht

A brn

B grn

C gra pnk red blk gra/pnk red/blu blu

456

SENSICK CATALOGUE

4-pin, M 12

TX+

Send data ( SSI: data + )

Q1

RX+ Receive data ( SSI: Clock + ) D NC E QS F QP G L+ H Receive data RX - ( SSI: Clock – ) I NC K TX - Send data ( SSI: data – ) L Q2 M M

5-pin, M 12 A

1 2 3 4

5-pin, M 12

5V

Q2 cable A

M

M

Q1

C

B

L+ cable B Shield

1 2 3 4 5

NC cable A NC cable B Shield

Page 8

DME 3000-2 Technical Data

211

DME 3000-

Measurement range

232

211P

100 . . . 8,000 mm 100 . . .10,000 mm 5 mm (measurement distance 8 m) 0.125 mm Diode laser, red light 2 (IEC 825-1/EN 60825-1) 3 B (IEC 825-1/EN 60825-1) MTTF 50,000 h

Light spot diameter Resolution Light source 2), light type Laser category Laser category Service life (at 25 °C) NIR blocking filter Supply voltage VS Ripple Power consumption

18 . . . 30 V DC 3) < 5 VSS4) ≤ 6 W 5)

Switching outputs Q1, Q2, Q P, Q S Output current IA max. Q1 and Q2 switching outputs Switching limit/switching hysteresis QP plausibility output QS service output

Connection type VDE protection class 6) Circuit protection 7) Enclosure rating Ambient temperature TA

PNP/NPN HIGH = VS – < 2 V/LOW = < 2 V 100 mA – Reversible Q /Q Adjustable HIGH: measurement correct / LOW: measurement error HIGH: OK / LOW: pre-failure signalling output Plug

V A, B, C IP 65 Operation – 10 °C . . . + 45 °C Storage – 25 °C . . . + 75 °C Approx. 980 g SSI: GRIS/BINARY adjust., 24 or 25 bits RS 422: 4.8/9.6/19.2/38.4 kBaud Max. 12 MBaud Typical 0.4 mm/K (compensation on request)

Weight Interfaces Serial interface Profibus Temperature drift Measured value output SSI/Profibus RS 422, 38.4 kBaud Initialisation period

21 ms 21 ms 6s

1) Relative to front edge of object 2) Average service life 50,000 h at TA = + 25 °C 3) Limit values

4) May not exceed or fall short of VS tolerances 5) Without load 6) Reference voltage 50 V DC

7) A = VS connections reverse-polarity protected B = Output Q short-circuit protected C = Interference pulse suppression

Reproducibility and accuracy as a function of measurement distance DME 3000 21 . . 232 21 . . 232 21 . . 232 1m 2m 4m Measurement distance Reproducibility 8) White, 90 % remission Grey, 18 % remission Black, 6 % remission Accuracy 9)10) White, 90 % remission Grey, 18 % remission Black, 6 % remission

212

1 mm 2 mm 5 mm

0.5 mm 2 mm 1 mm 5 mm 2 mm 25 mm

1 mm 5 mm 2.5 mm 25 mm 8 mm –

2 mm 5 mm 25 mm

18) Environmental conditions constant, min. switching period 30 min. 19) 23 °C air temp, 977 hPA, min. switching period 30 min. 10) Re-calibration recommended after 25,000 h.

Order information Type 21 . .

10 mm – –

232 6m 5 mm 25 mm –

21 . . 8m

232 10 m

25 mm – –

20 mm – –

DME 3000-211 DME 3000-212 DME 3000-232 DME 3000-211P

Part no. 1 013 782 1 015 906 1 015 794 1 018 064

±5 mm ±5 mm ±5 mm ±5 mm ±10 mm ±5 mm ±20 mm ±5 mm ±30 mm ±20 mm ±5 mm ±5 mm ±10 mm ±5 mm ±30 mm ±10 mm – ±25 mm – – ±10 mm ±5 mm ±20 mm ±10 mm – ±10 mm – – – –

SENSICK CATALOGUE

457