Spec sheet · Sick
DME 2000/DME 3000: Precise non-contact distance determination
Spec sheet8 pagesPDF 690 KB
SENSICK catalog spec sheet for the SICK DME 2000 and DME 3000 laser distance measuring devices: ranges, wiring, technical data and part numbers.
Covers · 1 model
The models it covers
Summary
What is in it
Catalog pages from the SENSICK catalog covering the DME 2000 and DME 3000 non-contact laser distance measuring devices, used to position high-bay stackers, cranes, lift cabins and automated guided vehicles. It gives application examples, dimensional drawings, connector pin assignments, full technical data (measurement range, accuracy, reproducibility, outputs, interfaces, supply voltage, enclosure and temperatures) and order information for the DME 2000-000 and the DME 3000-1 and DME 3000-2 versions.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Eight pages from the SICK SENSICK catalogue on the DME 2000 and DME 3000 laser distance measuring devices, including the DME 3000-1 and DME 3000-2 series. For each it gives the features, a dimensional drawing, the connector pin assignment, technical data and part numbers, with application examples such as cranes, high-bay stackers and rail-mounted units.
- Device
- DME 2000: laser distance measuring device using time-of-flight; up to 130 m with a reflector, up to 2 m in proximity mode p. 1, 3
- Measurement range
- DME 2000: proximity mode 100 to 2047 mm; reflector mode 0.1 to 130 m p. 3, 4
- Power
- DME 2000: 18 to 30 V DC; under 6 W without load p. 3, 4
- Interfaces
- DME 2000: RS 232 serial (4.8, 9.6, 19.2 kBaud); analog output 0 to 20 mA or 4 to 20 mA; 2 switching outputs, plausibility and pre-failure outputs p. 3, 4
- Connector
- DME 2000-000: 12-pin M 16 plug p. 3
- Display, setup
- 8-digit alphanumeric display and programming switches with a menu-driven dialogue p. 1, 3
- Temperature
- Operation -10 °C to +45 °C; storage -25 °C to +75 °C p. 4
- Part number
- DME 2000-000: 1 010 578 p. 4
- Light source
- Visible red laser diode p. 1, 4
- Weight
- Approx. 980 g p. 4
- Applications
- Positioning high-bay stackers, cranes, lift cabins and automated guided vehicles p. 1
- DME 3000 range
- DME 3000: up to 500 m with a reflector, up to 10 m in the proximity version p. 1
- DME 3000 interfaces
- DME 3000: RS 422 serial and SSI interface, Profibus, gateway to Interbus and DeviceNet p. 5
What this sheet walks you through
- Mounting dimensions and threaded holes p. 3
- Wiring the DME 2000 12-pin connector: wire colors and signals p. 3
- DME 3000 measurement range with each reflective tape or multi-reflector p. 6
- DME 3000-2 reproducibility and accuracy by distance and target color p. 8
- Application examples: crane monitoring, rack-serving units, coil weight, drill holes p. 2
Good to know
- The sheet states laser class 2 for the DME 2000; the DME 3000-2 page lists class 2 and 3 B. p. 3, 7
- Re-calibration is recommended after 25,000 hours. p. 4
- For the DME 3000 connection types, the adapter is not included in delivery. p. 5
- The sheet states an IP 65 enclosure rating for the DME 2000. p. 4
Questions this sheet answers
How far can the SICK DME 2000 measure?
Up to 130 m with a reflector and up to 2 m in proximity mode, without a reflector. p. 1
What is the part number of the DME 2000?
The standard type DME 2000-000 is part no. 1 010 578. p. 4
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file