Technical Description "Network Controller CLX 200"

CLX 200 Operating and parametrization menu

(Values printed in bold are set as the basic setting.)

Parametrization Net interface Baud rate *19200 Bd | | | *38400 Bd | | ACK/NAK _____s *Noo | | *yes | | | Host interface Data format Baud rate *300,.., 9600,.., 38400 Bd | | | | | | | Data bits. *7 | | | | *8 | | | Parity *no | | | | *even | | | | *odd | | | | *space | | | | *mark | | | Stop bits *1 | | | *2 | | | | | Protocol type __ CLX Header *02 00 00 00 00 00 | | Standard Terminator *03 00 00 00 00 00 | | Time-out *100 ,... 2000,.., 6000 ms | | Interface control___ *No | | | *RTS/ CTS | | | *®XON/ XOFF | | ACK/NAK____ *INoo | | *framed | | *unframed | | | *Output configuration | | | Standard configuration_*No | *yes | Emulation *CLE 200 | w Language shift *deutsch © Start of menu | *english | *italiano | *francais | Quit menu *temporary *no change *permanent

Fig. 5. Summary of menu (software version V 1.00)

The complete parameter setting can be output at the terminal interface with the "Output configuration" menu function.

Erwin Sick GmbH, Optik-Elektronik, Material Handling Automation, Nimburger StraBe 11, D-79276 Reute

Page 41

Page 42 read from a scan by OCR; it may hold reading errors

Technical Description "Network Controller CLX 200" Issue: 28/06/93

6. Network operation

After power-up, the CLX 200 polls all stations. Stations answering correctly are entered in a poll list. All the stations entered in the list are then continuously polled in sequence. In each polling cycle, a station not on the list is additionally polled, thereby setting an optimum polling cycle for any number of stations. Stations added subsequently are detected and entered in the polling list. Switched-off stations are not entered in the list. The CLX 200 provides the network stations with 32 buffers for the reception of their reading data. If the data buffers are full, the CLX 200 stops with network operation until data is again received by the host, thereby freeing a data buffer in the CLX 200 for code reader data. In network operation, an ACK/ NAK protocol can be used for data security. The network stations must have the same protocol setting.

6.1. Polling cycle time

The polling cycle time is the time between two pollings of the CLX 200 at the same network station. For each network setting (network protocol; network baud rate) there is a minimum processing time per network station, provided the transmitted useful-data length does not exceed specified values (Fig. 6). The sum of the processing times of all of the stations present and one "search station” gives the polling cycle time of the network,

The processing time for a network station is extended only if the useful-data length of the data string exceeds the parameter-dependent limiting value. The processing time is extended by 520 us (19200 Bd network Baud rate) respectively 260 us (38400 Bd network Baud rate) for every extra data byte. These times are maximum values and only apply if all the network stations transmit data to the CLX 200 simultaneously. If data transmission is staggered, the network controller attempts to achieve an average polling cycle time by reducing the polling time for stations which have presented no data.

Example: The following average polling cycle time is obtained with five network stations without ACK/ NAK at 19200 Bd

Tpoll cycle time = (541) Polls/ cycle x 11ms = 66 ms/ cycle

The sixth poll is needed for the search poll for a new network station. After this time at the very latest, the CLX 200 starts to output to the host the data supplied by the first station.

The diagram shows the maximum processing time for a network station as a function of the network Baud rate, network protocol setting and quantity of useful data being transmitted with simultaneous data transmission from all network stations.

Page 42 Erwin Sick GmbH, Optik-Elektronik, Material Handling Automation, Nimburger StraBe 11, D-79276 Reute

Page 43 read from a scan by OCR; it may hold reading errors

Issue: 28/06/93 Technical Description "Network Controller CLX 200"

TPoll/Stations

[ms] | with ACK/NAK 14 | \ 7” | . . . . . . . v: . . 19 200 Bd | . . - oy. . . . without ACK/NAK | “ . ” . . . . . . 11 =| Pa . . . 8 | ~~ with ACK/NAK, . | . . . . . es ”. . . . without ACK/NAK - ied a ye 400 Bd 6 ue, - e | 0 | Useful data a ee

Fig. 6. Polling cycle time as a function of quantity of useful data

7. Host interface

The code reader data obtained in network operation is output at the host interface of the CLX 200. The output parameters of the electrical interface (Baud rate;data format) can be set in the parametrization menu. The host string of the CLX 200 consists of the reading data, apparatus number of code reader and parameterizable header/ terminator of the CLX 200. The structure of the CLX 200 string is as follows:

< HEADER CLV_ID ------ data ------- TERMINATOR > max. 6 bytes 2 bytes max. 128 bytes max. 6 bytes

The header and terminator are parameterized in the CLX 200 menu. At least one character must be defined as the header/ terminator. Framing the host data string is absolutely essential for both data directions. The code identification (see CLV 2xx Operating Instructions) can be set as the parametenizable header/ terminator character. This setting can be achieved by setting the highest numerical value above

7F hex in the header/ terminator positions that are to be set. The identifier for code identification is "ID". In data strings from host to CLX 200, the header/ terminator position parameterized with "ID" is not checked.

7.1. Data output CLX 200, Host

Data obtained on the network is passed on to the host as soon as it is available at the CLX 200. If the ACK/ NAK protocol is set at the host interface, subsequent data is not output until the protocol has been executed.

Erwin Sick GmbH, Optik-Elektronik, Material Handling Automation, Nimburger StraBe 11, D-79276 Reute Page 43

Page 44 read from a scan by OCR; it may hold reading errors

Technical Description "Network Controller CLX 200" Issue: 28/06/93

7.1.1. ACK/ NAK

The data protocol (ACK/ NAK) which can be set at the host interface permits repetition of reading data when errors/ faults occur in data transmission. Activation of the ACK /NAK protocol affects both data directions between host and CLX 200. Using the protocol calls for setting the time-out constant for the host's protocol response. This value should be chosen so as to ensure reliable operation with the maximum response delay of the host computer. In protocol operation, a data format with header/ terminator is similarly required for the framed protocol string.

The following situations can arise with CLX 200 data output:

Step CLX 200 Host 1 data 1 ----- (time-out) ----->

<----- ACK 2 data 2 ----- (time-out) ----- >

<------- NAK 3 data 2 ----- (time-out) ----->

<- - - -- ACK 4 data 3 ----- (time-out) -----> no reply 5 EOT ------ (time-out) -----> 6 data 4 ----- (time-out) > eta Key;

to step 1) After the data string has been output by the CLX 200, the CLX 200 starts a "time-out", during which a reaction is expected from the host computer. An ACK received during the time-out causes the CLX 200 to output the next data string.

to step 2) If the host computer acknowledges the data string sent by the CLX 200 with a NAK, the CLX 200 repeats the data up to a maximum of three further times until either an ACK is received or the time-out has elapsed and no protocol reply is received. If the CLX 200 receives no positive acknowledgement, an EOT string like that in 5.) is sent.

to step 4) If the data string output by the CLX 200 is not acknowledged within the time-out, the CLX 200 outputs an EOT to inform the host computer that there is a breach of protocol. After the EOT, the time-out again extends until the CLX 200 sends the next data buffer to the host.

7.2. Data reception CLX 200, Host Data received at the host interface of the CLX 200 is immediately passed on to the network station. When using the ACK/ NAK protocol, the CLX 200 responds to the host with the protocol string after the data has been received by the CLX 200.

Page 44 Erwin Sick GmbH, Optik-Elektronik, Material Handling Automation, Nimburger StraBe 11, D-79276 Reute

Page 45 read from a scan by OCR; it may hold reading errors

Issue: 28/06/93 Technical Description "Network Controller CLX 200"

7.2.1. ACK/ NAK

The CLX 200 responds with ACK, provided there is no fault/ error in transmission or in the message structure. If an error is recorded when receiving the host data, a NAK is transmitted to the host until a correct data message has been received. For the CLX 200 to reply with a NAK, at least the first header character must have been correctly received. Regardless of this, errors in the string structure of the host string from the first character onwards are indicated.

The following situations can occur with CLX 200 data reception:

Step CLX 200 Host

1 <----- data 1 ACK ------ >

2 <----- data 2 NAK ------ >

3 <----- data 2 ACK ------ >

Key:

to step 1) Correct host data is immediately answered with an ACK.

to step 2) Faulty data is answered with a NAK and a repetition of the data string is anticipated.

7.3. Interface control

Regardless of the data protocol used, the host interface can be operated with RTS /CTS or XON/ XOFF control. RTS/ CTS control is possible only when using an RS-232 host interface module.

7.3.1 RTS/ CTS

The host computer can use the CTS input at the host interface of the CLX 200 to interrupt the output of data strings. Interruption takes place after the CLX 200 has recognized the control signal. Data output is resumed when the control signal is cancelled.

If the buffer capacity is reached during data reception, the CLX 200 sets the RTS control signal to notify the host of full buffers. The control signal is reset again when there is free buffer space.

7.3.2. XON/ XOFF

XON/ XOFF control works in a similar way to RTS/ CTS control. The Host/ CLX 200 transmits an XOFF (13 hex) as a contro! signal to stop data output by the partner device. An XON (11 hex) causes resumption of data output.

7.4. Baud rates

Baud rates of 300 to 38400 Bd can be used at the host interface. A host/ network Baud-rate combination of 19200/ 38400 Bd is not possible. Should this combination be set, the value of the network Baud rate is adopted as the host Baud rate. In the "Output configuration" menu function, the parameters used are output at the terminal interface.

Erwin Sick GmbH, Optik-Elektronik, Material Handling Automation, Nimburger StraBe 11, D-79276 Reute Page 45

Page 46 read from a scan by OCR; it may hold reading errors

Technical Description "Network Controller CLX 200" Issue: 28/06/93

8. Terminal interface

The terminal interface is used as a logging interface and can alternatively be used as an operating interface for the CLX 200's parameterizing menu. During reading mode, all the error messages which occur are output at the terminal interface. In contrast to the display indication, the error message that is output for each error/ fault permits a qualitative statement conceming error frequency and cause of error.

9. Error] fault messages

During network operation, the working of the device is monitored and incorrect procedures (e.g. transmission errors) are signalled. Error messages are output on the display and at the terminal interface. Error messages overwrite the current screen contents and can be deleted by pressing a key on the keyboard of the device. The error messages at the terminal interface can be logged with a printer/ PC.

#xy Error message

The first line of the error message shows the error/ fault code number (# xy). This is followed by the error text, giving an indication of the cause of the error.

The following errors are detected at the host interface:

# 10 Character error, _(parity/ framing/ Baud rate) # 20 String error (error in message structure) # 30 Protocol error (host sending no/ three NAKs)

# 40 Host > CLV (no reception of data possible) Buffer overflow

The following errors are detected at the network interface:

#01, Character error, (parity/ framing) # 02 String error (incorrect string structure on network) # 03 Protocol error (no protocol reply from network station)

# 04 CLV, Host (polling on network interrupted until the host Buffer overflow has received another CLX data string)

#05 Network interface (RS 485 network interface module faulty) defective

If errors/ faults are observed in the parameter store at power-up, error output takes place and the standard parameters are used.

# 98 Parameter error

Page 46 Erwin Sick GmbH, Optik-Elektronik, Material Handling Automation, Nimburger StraBe 11, D-79276 Reute

Page 47 read from a scan by OCR; it may hold reading errors

Issue: 28/06/93 Technical Description "Network Controller CLX 200"

10. CLE 200 emulation

Emulation of the CLE 200 can be set in the CLX 200's parameterizing menu. It is consequently possible to set the parameters of a connected code reader in the CLV 2xx series-(Fig. 7). The mode of operation of the device in "CLE Emulation" can be obtained from the Technical Description/ Operating Instructions of the CLE 200 (Part No. 8 007 023).

The standard CLE 200/ CLV 2xx data connection cable (Part No. 2 013 568) enables diagnostic data for a CLV 2xx to be shown on the display of the CLX 200, and the parameters of the connected code reader to be set. The CLE 200 operating mode presupposes that the RS-422/ 485 version is used as the type of interface for a connected CLV 2xx.

CLV 21x CLX 200 CLV 23x CLE Emulation

|Host / |Term. CLV

| | | | | | | | | | | | 1 | {1 |: |9 | |

9

| CLV/CLE | Data cable |

| | | | | | | | | | | | | | | | |

Fig. 7. Emulation of the CLE 200 Operating Unit by the CLX 200

"CLE 200 Emulation" is selected in the parameterizing menu (see 5. Operating and parametrization menu). After this menu function has been selected, the CLX 200 behaves like a CLE 200. The device no longer works as a network controller. A return from "CLE 200 Emulation" to the menu of the network controller is achieved by calling up the CLX 200 menu again ("" and "2" respectively "Q"). CLE 200 Emulation is switched off and the CLX 200 menu is resumed from the place at which selection of Emulation was made.

CLX 200 > ESC ed > CLX- - - CLE Emulation > CLE-, ESC em > CLV- Network operat. < Quitmenu «< Menu ¢« Qed «€ Operation < Quit menu <¢ Menu

Power-up mode of the CLX 200 is always the network controller operating mode, regardless of the CLE 200 Emulation last used.

Erwin Sick GmbH, Optik-Elektronik, Material Handling Automation, Nimburger Stra3e 11, D-79276 Reute Page 47

Page 48 read from a scan by OCR; it may hold reading errors

Technical Description "Network Controller CLX 200" il. Technical data

Type CLX 200- Function Network controller Number of network stations Max. 31

Communication in network

Polling of network stations

Displays

LCD, 2 x 16 digit, illuminated; 1 LED status indicator to signal variable parameter values

Keyboard

Membrane keyboard, 5 keys with tangible action-point

Operating modes

Network controller, CLE 200 emulation

Parametrization und operating

Via menu (4 languages)

Electrical connections

"CLV" (Network), "Host", "Terminal" and "I/O" via 9-pin D-Sub connectors

Data interface "CLV" (Network)

RS-485, electrical isolated

Output buffers 32, each with 128 bytes Termination 390 Q / 220 Q/ 390 Q Data transmission rate 19200 / 34800 Bd Data format 7 data bits; parity odd; 1 stop bit Protocol ACK/ NAK, adjustable Line length Max. 1200 m Spur-line length Max. 3m Network cable Twisted screen-pair cable (e.g. MISCO 1865) Data interface "Host" CL 20 mA active (options: CL 20 mA passive, RS-232, RS-422) Input buffers 16, each with 128 bytes Data transmission rate 300 to 34800 Bd Data format 7/ 8 data bits; parity even, odd, mark, space or no; 1/ 2 stop bit Data output format Header, CLV-identification, data, terminator Protocol ACK/ NAK (framed ord unframed), adjustable

Interface control

XON/ XOFF or RTS/ CTS (only for RS-232)

Recommended cable length

CL 20 mA: max. 1200 m; RS 232: max. 15 m; RS 422: max. 1200 m

Data interface "Terminal"

RS 232

Data transmission rate 2400 Bd Data format 8 data bits, arity none, 1 stop bit Data output format Fixed Protocol No Recommended cable length Max. 15m Function interface "/O" Only for CLE 200 emulation

Switching inputs IN

"Sensor’, opto-decoupled, Uin= max. 30 V

Switching outputs OUT

"Dev. Rdy”, 1 x PNP, lout= max. 20 mA; 2 x PNP reserved

Operating voltage 230 VAC/ (option: 115 VAC) +10%/- 15% Current consumption Approx. 6 W (with CLE 200 emulation and CLV 2 approx.35 W) Housing Diecast aluminium

Enclosure rating

IP 31 (housing); with plug cups IP 65 to DIN 40 050

Protection class

1 to VDE 0106/160

EMV test IEC 801, 71-5 Vibration test IEC 68, T2-6 test FC Shock test IEC 68, T2-27 test EA Fixing To floor, using two lugs provided Ambient operating temperature Oto + 40°C Storage temperature -20 to + 70 °C Max. rel. humdity 90%, non-condensing Weight 2.2 Kg

Dimensioned (L x W x H)

200 mm x 100 mm x 80 mm

Table 1

Page 48 Erwin Sick GmbH, Optik-Elektronik, Material Handling Automation, Nimburger StraBe 11, D-79276 Reute

Issue: 28/06/93

Page 49 read from a scan by OCR; it may hold reading errors

Issue: 28/06/93 Technical Description "Network Controller CLX 200"

12. Ordering information

12.1 Network controller

Part No. Type Network interface | Host interface -| Operating voltage 1012 216 CLX 200-3021 RS 485 CL 20 mA passive 230 VAC

1011 949 CLX 200-3041 RS 485 RS 232 230 VAC

1 012 230 CLX 200-3031 RS 485 RS 422 230 VAC

1012 231 CLX 200-1041 RS 485 RS 232 115 VAC

1 012 232 CLX 200-1031 RS 485 RS 422 115 VAC

Table 2

12.2 Accessories

Part No. Description Cores Length Connection 2 013 428 Mains conncetion lead with 3-pin mains plug and 4-pin cable 3 5m CLX 200 to mains receptacle 6 007 225 Receptacle (of part No. 2 013 428) - - - 6 007 508 Data connection cable, twisted pair, round, 4 x 2 cores, screened | 8 supplied by | CLK 200 to CLV metre

6 009 438 D-Sub plug-connector housing for 9-pin inserts - - - 6 007 335 D-Sub plug-connector insert, 9-pin, socket connector (receptacle) | - - - 6 007 336 D-Sub plug-connector insert, 9-pin, pin connector (plug) - - -

2 012 981 IP 65 plug cup with 9-pin D-Sub plug and receptacle - - - (quantity needed: two for CLX 200)

Table 3

13. Dimensioned diagram aa Cae

117 t~

| 187 "| Hole diam. $ mm G | a <4 bo 4 } i va All dimensions in mm

Fig, 8. Dimensions of CLX 200 network controller

Erwin Sick GmbH, Optik-Elektronik, Material Handling Automation, Nimburger StraBe 11, D-79276 Reute Page 49

Page 50 read from a scan by OCR; it may hold reading errors

Technical Description "Network Controller CLX 200" Issue: 28/06/93

14. Electrical connections

14.1. Electrical connections (summary)

5 4 4 5, - _* Receptacle Plug (oo) 9-pin, baxg 9-pin,, D-Sub, D-Sub 9 6 6 9 "CLV" (Network) connection "Terminal" connection Pin | Terminal!) CLV (RS-485) Pin | Signal 1 + 24 VDC - 1 reserved 2 TxD - 2 RxD 3 RxD : 3. | TD 4 - Term 4 reserved 5 GND - 5 GND 6 reserved 6 reserved 7 : GND_NET 7 reserved 8 - R/T + 8 reserved 9 - RT - 9 reserved 1) only for CLE 200 emulation Table 6 Table 4 _ 41 5 5 4, - Plug Receptacle (oEre] | 9-pin, aay] 9-pin, D-Sub D-Sub 6 9 9 6 "Host" connection "/O" connection Pin | Signal’) Pin | Signal!) 1 - 4 + 24 VDC 2 - 2 IN 1 3 - 3 Sensor 4 - 4 Dev Rdy 5 GND 5 GND 6 RxD/ R+ 6 IN V+ 7 CTS/ R- 7 OUT 1 8 TxD/ T+ 8 OUT 2 9 RTS/ T- 9 IN GND 1) Host data according to type of used 1) only for CLE 200 emulation interface Table 7 Table 5 Note: - "Power" Pin | Signal | Function If using the RS 232 interface don't link connection [1 L1 230 VAC / 115 VAC) the CLX 200 to a PC via a common 2 - . RS 232 interface cable. Round 3 N 230 VAC / 115 VAC?) There is a different pin allocation given plug, 4 PE Protective conductor at the CLX 200. 4-pin 1) see type plate Table 8

Fig. 9. Pin allocation of electrical connections

Page 50 Erwin Sick GmbH, Optik-Elektronik, Material Handling Automation, Nimburger StraBe 11, D-79276 Reute