Page 147

Operating instructions

Appendix

Chapter 10

CLV 43x/44x Bar Code Scanner

10.4.4

CLV Setup user interface

The graphical user interface (GUI) of CLV Setup is largely self explanatory. The online CLV Setup Help function provides a description of how to use the program under HELP, PROGRAM INFORMATION. The GUI is shown in Fig. 10-26 below. The GUI comprises the following elements: •

Title bar that displays the program name, current configuration file and status, e.g. "No File"

•

Menu bar with pull-down menus

•

Toolbar with buttons for triggering various functions

•

Drop-down list (top right) for selecting the device type

•

9 tabs (READING CONFIGURATION, DEVICE CONFIGURATION etc.). The parameters on the tabs are grouped according to their function. Some of these parameters open further dialog boxes.

•

A status bar (at the bottom of the window) with two display fields for the communication activities between CLV Setup and the CLV, display of interface parameters of the PC, error display field (system errors) of the CLV, device specification field and status display for the connection to the CLV.

Fig. 10-26: User interface of the "CLV Setup" software

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-31

Page 148

Chapter 10

Appendix

Operating instructions CLV 43x/44x Bar Code Scanner

10.4.5

Functions

The CLV Setup program features functions to carry out the following: •

Loading the default setting of the parameter set from the database

•

Automatic communication attempt with the CLV when the program is started

•

Automatic software compatibility check in the CLV

•

Uploading parameter set stored in the CLV

•

Changing the parameter values on the tabs

•

CLV Assistant for simplified parameterization

•

Saving the changes to the parameter set in the CLV (download)

•

Saving the changes to the parameter set as a configuration file "*.scl"

•

Printing the configuration files

•

Exporting the configuration files in RTF format

•

Printing the parameter set in the form of profile bar codes

•

Direct access to the CLV via a Terminal Emulator (select operating mode, start operating functions, log file for communication between the CLV and CLV Setup, extended terminal mode, e.g. for displaying CLV messages)

•

AutoBaud detect for automatic communication setup with the CLV

•

Selecting the COM port for adapting the data transfer parameters

•

Monitoring the data communication of the CLV host interface

•

Selecting the display language

•

Selecting the units of measure

•

Displaying the last 10 configuration files that were processed

•

Saving the CLV type that was selected last

•

Automatic storage confirmation prompt when changes are made to the configuration file

•

Wizards for individual functions

•

Setting switches for starting the program in the "CLVmain.ini" file

•

Hot keys [F keys] for essential functions (program operation without a mouse)

•

Starting program with SCL file as argument

•

Context-sensitive help via the [F1] key

10.4.6

“CLV Setup Help“ online help

The online help program "CLV Setup Help" assists you in operating the "CLV Setup" software. The help program runs in an HTML browser (e.g. Netscape NavigatorTM, Microsoft Internet ExplorerTM or the accompanying I-ViewProTM). You can call up context-sensitive help on each parameter as well as a description of its function and permissible values.

10-32

1.

Press the [F1] key. The browser is launched automatically and displays the help topic.

2.

If the program cannot find a browser, it asks you to specify the storage location on the hard disk. Enter the name of the executable file and the path in the dialog box (e.g. Iviewpro32.exe in the "Iview" directory).

3.

Use the [ALT] + [TAB] keys to switch between the CLV Setup and CLV Setup Help applications and prevent several browser windows from being opened.

4.

To display an overview of the help function, select HELP, CONTENTS from the CLV Setup menu bar.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 149

Operating instructions

Appendix

Chapter 10

CLV 43x/44x Bar Code Scanner

5.

To display information on a tab, click the tab in the top, horizontal frame. The vertical frame on the left-hand side of the screen then displays a list of parameters.

6.

Click on a parameter for a description. CLV Setup Help then displays the associated help text in the right-hand frame and jumps to the parameter heading.

10.4.7

Transferring parameter sets between CLV Setup and the CLV

See Chapter 6.4.1 "Configuring CLV with the user interface of CLV Setup", Page 6-5. 10.4.8

Unknown parameters

Uploading from the CLV If the CLV Setup program does not recognize the parameters or parameter values of the CLV transferred during the upload, it outputs a warning message. Unknown parameters/ parameter values can result from the following, for example: The CLV is a special device or the version of CLV Setup is older than the software of the CLV. CLV Setup displays the unknown parameters in the window on the EXTRAS tab. The parameters are displayed in the form of command strings and can be edited using the command string conventions. In this way, upward compatibility with the CLV is ensured. When the parameter set is saved as a configuration file in CLV Setup, these parameters/values are also taken into account as with a download to the CLV. Downloading to the CLV If the CLV does not accept individual parameters or parameter values in the parameter set downloaded with CLV Setup, it outputs a separate warning for each parameter on the screen. The is due to the fact that one of the CLV Setup software versions is newer than the software in the CLV, and it contains new parameters/values arising from the continued development of this CLV type. The effected CLV contains an older software version which does not recognize these parameters/values, however. We recommend that you check the effects of warnings in the CLV as follows:

8 008 568/K949/10-06-2002

1.

Check whether the CLV functions correctly after the parameter set is downloaded.

2.

Click in the toolbar. CLV Setup loads the default setting from the database.

3.

Click in the toolbar. CLV Setup copies the problem parameter set from the CLV.

4.

Click in the toolbar. CLV Setup prints out the problem parameter set when you confirm the dialog box.

5.

Open the previous configuration file "*.scl" for the CLV.

6.

Click in the toolbar. CLV Setup prints out the problem parameter set when you confirm the dialog box.

7.

Compare the two parameter sets. To restore the previous status, correct individual parameters in the problem parameter set if necessary and download them to the CLV again.

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-33

Page 150

Chapter 10

Appendix

Operating instructions CLV 43x/44x Bar Code Scanner

Opening configuration files "*.scl" Every time it loads configuration files, CLV Setup checks whether it recognizes all the parameters/values. If the program detects an error, it outputs a warning and enters the problem parameter/ value in the window on the "EXTRAS" tab. 10.4.9

Log file in Terminal Emulator

The Terminal Emulator can log the communication between CLV Setup and the CLV. CLV Setup stores the data transmitted in both directions with the following identifiers: CLV -->:

CLV sending to CLV Setup

--> CLV:

CLV receiving from CLV Setup

1.

Click in the toolbar. The Terminal Emulator window is then displayed.

2.

Click the empty checkbox in front of the WRITE LOGFILE option on the right. The SAVE LOG FILE AS... dialog box is then displayed.

3.

Enter a file name with the extension ".log" and exit the window with SAVE. CLV Setup saves the file in the "data" subdirectory and records communication in the log file.

4.

To terminate logging, click the checkbox in front of the WRITE LOGFILE radio button again or close the Terminal Emulator.

10.4.10 Starting CLV Setup with an INI file as an argument When the program is started, CLV Setup can also be transferred the name of an INI file as a parameter. To do so, enter "/INI" in front of the file. Example: "CLVmain32.exe\data\Set 1_430.scl /INI user.ini" CLV Setup is launched with the initialization data contained in the "user.ini" file and loads the configuration file "Set1_430.scl" from the "data" directory right away. The "user.ini" file must be stored in the same directory as "CLVmain32.exe". You can use this method to link CLV Setup to several different configurations on your Windows desktop. In this way, for example, you can prevent CLV Setup from attempting to establish a connection when a CLV is not connected. 10.4.11 CLV Assistant CLV Assistant simplifies parameterization and testing of the CLV, among other things. It carries out configuration of the CLV for a user-specific reading situation with one bar code in individual steps. The determined settings are transferred to CLV Setup.

10-34

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 151

Operating instructions

Appendix

Chapter 10

CLV 43x/44x Bar Code Scanner

10.5

Configuring the CLV with profile bar codes

10.5.1

Activating AutoSetup with a profile bar code

Profile programming uses special bar codes to parameterize the CLV via the optical interface (reading window) and to initiate device functions. The profile bar codes contain encoded parameter values or commands. It is not necessary to connect a PC to the CLV in order to carry out profile programming. Profile bar code no. 10 on the card supplied starts and ends AutoSetup. It can be presented to the CLV either immediately after the power supply has been switched on, during the wait time in the Free Running mode or during a reading pulse in the Reading mode. Z

Preparing AutoSetup

1.

AutoSetup overwrites important values in the current parameter set of the CLV. If the CLV has already been configured for a particular application, it is advisable to save the existing parameter set as a configuration file "*.scl" in CLV Setup (see Chapter 6.4.1 "Configuring CLV with the user interface of CLV Setup", Page 6-5).

2.

Have card no. 8 008 085 with the 12 preprinted profile bar codes ready.

Running AutoSetup after switching on the power supply 1.

Fold the card with the profile bar codes in such a way that only profile bar code no. 10 is visible.

2.

Switch on the power supply of the AMV/S 40 Connection Module (of the CLV). The CLV confirms that the self-test has been completed successfully by outputting a tone via the beeper. The "Device Ready" LED lights up. It then switches to the Free Running mode for 5 seconds. The scan line appears when the "Laser On" LED lights up. Line scanner with oscillating mirror: In AutoSetup mode, the CLV behaves as follows: – In "Oscillating" mode (default setting: oscillating with fixed Amplitude) switches to Oscillating mode and positions the scan line at the angle CW = 50 (corresponds to an angle of emergence under 105°). This position cannot be changed. – In "One-shot" mode, it also positions the scan line under the angle CW = 50. – In "Fixed Position" mode, on the other hand, the selected scan line position remains unchanged.

8 008 568/K949/10-06-2002

3.

Present profile bar code no. 10 within 5 seconds. The CLV confirms that AutoSetup has started by outputting a tone via the beeper. It temporarily activates the standard decoder. The "Device Ready" LED is extinguished.

4.

Present the application-specific bar code at the maximum reading distance for the application. Note the limit values of the CLV here (refer also to the reading field graphs in Chapter 10.2 "Specification diagrams", Page 10-1). To prevent surface reflections, rotate the bar code towards the CLV approximately 15° away from the vertical axis (see Fig. 4-8, Page 4-6). Leave the bar code in this position.

5.

The CLV confirms that AutoSetup has been completed successfully by outputting two consecutive acoustic signals via the beeper and activating the "Result" LED for 100 ms (default setting). It overwrites the appropriate parameter values in the current parameter set in the RAM and stores these permanently in the EEPROM. The CLV returns to the Reading mode with the decoder parameterized for this purpose. The "Device Ready" LED lights up. The CLV only evaluates the presented code type and length the next time a bar code is read.

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-35

Page 152

Chapter 10

Appendix

Operating instructions CLV 43x/44x Bar Code Scanner

Running AutoSetup in the Reading mode 1.

Fold the card with the profile bar codes in such a way that only profile bar code no. 10 is visible.

2.

Start the reading pulse: block the light path of the photoelectric switch or close the switch. The "Laser On" LED lights up. The scan line then appears.

3.

Present profile bar code no. 10. The CLV confirms that AutoSetup has started by outputting a tone via the beeper. It temporarily activates the standard decoder. The "Device Ready" LED is extinguished.

Continue AutoSetup from Step 4 as in Running AutoSetup after switching on the power supply, Page 10-35. AutoSetup canceled by the CLV in the event of a No Read If the CLV was not able to execute AutoSetup successfully, it cancels the search mode by outputting a long acoustic signal via the beeper. The current parameter set in the CLV does not change. The CLV returns to the Reading mode with the decoder parameterized for this purpose. The "Device Ready" LED lights up. Running AutoSetup again 1.

Switch the power supply of the connection module (of the CLV) off and on again.

2.

Present profile bar code no. 10 again after the first tone from the beeper. The CLV confirms that AutoSetup has started by outputting an acoustic signal via the beeper. It temporarily activates the standard decoder. The "Device Ready" LED is extinguished.

– or – 1.

Start the reading pulse again: block the light path of the photoelectric switch or close the switch. The "Laser On" LED lights up. The scan line then appears.

2.

Present profile bar code no. 10. The CLV confirms that AutoSetup has started by outputting an acoustic signal via the beeper. It temporarily activates the standard decoder. The "Device Ready" LED is extinguished.

Continue AutoSetup as described in Step 4 in Chapter "Running AutoSetup after switching on the power supply", Page 10-35.

¾ If AutoSetup is unsuccessful again, check whether the CLV is able to read the bar code correctly (reading distance, tilt, more than one bar code in the reading field). Terminating AutoSetup prematurely

¾ Present profile bar code no. 10 again during AutoSetup. The CLV confirms that AutoSetup has been aborted by outputting a long tone via the beeper. The current parameter set in the CLV does not change. The CLV returns to the Reading mode with the decoder parameterized for this purpose. The "Device Ready" LED lights up.

10-36

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 153

Operating instructions

Appendix

Chapter 10

CLV 43x/44x Bar Code Scanner

Checking the determined read and code configurations Check the CLV settings with a percentage evaluation. A PC with the "CLV Setup" program installed on it has to be connected for this purpose. See also Chapter "Activating AutoSetup via the user interface of CLV Setup", Page 6-16. 10.5.2

Profile programming

Profile programming uses special bar codes to parameterize the CLV via the optical interface (reading window). The profile bar codes contain encoded parameter values. It is not necessary to connect a PC to the CLV in order to carry out profile programming. The profile bar codes are presented to the CLV individually for reading. It copies the parameter values to the current parameter set. The changes are permanently valid after programming has been completed; in some cases, they also have an immediate effect on the reading and output characteristics of the CLV. The profile bar codes can be presented to the CLV either immediately after the power supply has been switched on, during the wait time in the Free Running mode or during a reading pulse in the Reading mode. During profile programming, the CLV does not output a reading result and does not respond to an external reading pulse. Profile bar codes are created and printed via the user interface of CLV Setup after the application-specific parameter set has been compiled (see Section "Printing profile bar codes"). The enclosed card no. 8 008 085 ("Configuration Profiles for CLV 41x Bar Code Scanners") contains 12 preprinted profile bar codes. They can be used to parameterize tested settings or to trigger specific functions (e.g. AutoSetup). Table 10-7, Page 10-40 explains the meanings of the individual profile bar codes. Profile bar codes no. 11 and no. 12 on the card are of no significance for CLV 43x/44x. Preparing profile programming 1.

Profile programming overwrites values in the current parameter set of the CLV. If the CLV has already been configured for a particular application, it is advisable to save the existing parameter set as a configuration file "*.scl" in CLV Setup (see Chapter 6.4.1 "Configuring CLV with the user interface of CLV Setup", Page 6-5).

2.

Have the printed profile bar codes of the compiled parameter set or card no. 8 008 085 ready.

Performing profile programming after switching on the power supply 1.

Switch on the power supply of the AMV/S 40 Connection Module (of the CLV). The CLV confirms that the self-test has been completed successfully by outputting a tone via the beeper. The "Device Ready" LED lights up. It then switches to the Free Running mode for 5 seconds. The scan line appears when the "Laser On" LED lights up. Line scanner with oscillating mirror: The CLV behaves as follows: – In "Oscillating" mode (default setting: oscillating with fixed Amplitude) switches to Oscillating mode and positions the scan line at the angle CW = 50 (corresponds to an angle of emergence under 105°). This position cannot be changed. – In "One-shot" mode, it also positions the scan line under the angle CW = 50. – In "Fixed Position" mode, on the other hand, the selected scan line position remains unchanged.

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-37

Page 154

Appendix

Chapter 10

Operating instructions CLV 43x/44x Bar Code Scanner

2.

Present the first profile bar code in the printed sequence (or the desired profile bar code from the card) within 5 seconds. Fold the printout/card in such a way that only one profile bar code is visible at any one time. The CLV confirms that the bar code has been read successfully by outputting a tone via the beeper and waits 10 seconds for the next profile bar code. It copies the new parameter value(s) to the current parameter set in the RAM.

3.

Present the next profile bar code within 10 seconds. The CLV confirms that the bar code has been read successfully as described in Step 2.

4.

Allow 10 seconds to pass after the last profile bar code has been read. The CLV exits the programming mode and saves the new parameter values permanently in the EEPROM. It also switches off the laser diode. Following this, it returns to the Reading mode and confirms this by outputting two consecutive acoustic signals via the beeper. The "Device Ready" LED lights up.

The CLV then uses the new parameter values. Performing profile programming in the Reading mode 1.

Start the reading pulse: block the light path of the photoelectric switch or close the switch. The "Laser On" LED lights up. The scan line then appears.

2.

Present the first profile bar code in the printed sequence (or the desired profile bar code from the card). Fold the printout/card in such a way that only one profile bar code is visible at any one time. The CLV confirms that the bar code has been read successfully by outputting a tone via the beeper and waits 10 seconds for the next profile bar code. It copies the new parameter value(s) to the current parameter set in the RAM.

Continue profile programming from Step 3 in Chapter "Performing profile programming after switching on the power supply", Page 10-37. Note

When the profile bar code is presented to the CLV, note that the changes caused by the new parameter values in the RAM can have an immediate effect on the reading characteristics of the CLV. Under unfavorable conditions, the CLV will only be able to read profile bar codes with great difficulty or not at all. Changes to the active evaluation range of the scan line (min./max. CP value), increases in the scan frequency and changes to the focus position for each profile bar code must be handled with care. If the CLV is not able to read any further profile bar codes, it must be corrected accordingly on the tabs via the user interface of CLV Setup. A PC must be connected to the CLV for this purpose. Canceling profile programming

¾ Switch off the power supply of the CLV within 10 seconds of presenting the last profile bar code. The temporary changes to the current parameter set in the RAM are lost. After the power supply has been switched on again, the CLV uses the values from the last parameter set that was stored permanently.

10-38

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 155

Operating instructions

Appendix

Chapter 10

CLV 43x/44x Bar Code Scanner

Printing profile bar codes Profile bar codes are created and printed out via the user interface of CLV Setup. It is not necessary to connect a PC to the CLV if the current parameter set of the CLV has been saved as a configuration file "*.scl" in CLV Setup. CLV Setup creates a minimum set of profile bar codes using the parameter values in the tabs and the default setting of the CLV. This comprises: •

A standard profile (all codes types active or all code types locked)

•

A host interface profile

•

A greater or smaller number of profile bar codes depending on the difference between the two above-mentioned profiles and the current setting of the entire parameter set.

CLV Setup prints out the bar codes in a defined sequence. The size, position and number of codes on the page can be set. 1.

Open the configuration file "*.scl" of the current parameter set. CLV Setup displays the parameter values of the CLV on the tabs.

2.

If desired, make any necessary changes to the parameter set. Save the new parameter set in the configuration file "*.scl" under a new name.

3.

In the menu bar, choose PROFILES and CONFIGURE PRINTING. Confirm the print option default setting for the profile bar codes or define new ones (see below).

4.

In the menu bar, choose PROFILES and PRINT PROFILES. CLV Setup determines the required number of bar codes. The PRINT dialog box is then displayed.

5.

Specify the number of printouts. Define the page format if necessary. For this purpose, click the PROPERTIES button. Relatively long profile bar codes must be printed in landscape format!

6.

Confirm the dialog box with "OK". CLV Setup then prints out the profile bar codes.

Defining print options for profile bar codes 1.

In the menu bar, choose PROFILES and CONFIGURE PRINTING. The BARCODE PRINTING OPTIONS dialog box is then displayed.

2.

Choose the desired print options in the BARCODE and PAGE LAYOUT tabs and confirm the dialog box. CLV Setup then asks if the print options are to be saved.

3.

To save the print options, confirm this prompt with "OK". The SAVE SETTINGS AS... dialog box is then displayed.

4.

Enter a file name in the "*.prf" format: Confirm the dialog box with SAVE. CLV Setup saves the print options in a configuration file in the directory "CLV".

The default setting of the print options is active when CLV Setup is started. Preprinted profile bar codes The enclosed card no. 8 008 085 ("Configuration Profiles for CLV 41x Bar Code Scanners") contains 12 preprinted profile bar codes. They can be used to parameterize tested settings or to trigger specific functions (e.g. AutoSetup). The individual segments of the card can be folded in such a way that the CLV only reads the desired profile bar code. The profile bar

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-39

Page 156

Chapter 10

Appendix

Operating instructions CLV 43x/44x Bar Code Scanner codes are explained in Table 10-7, Page 10-40, and the functions of the individual parameters in "CLV Setup Help". Bar code

Function

Profile 1

Default setting of CLV for all parameter values. Code configuration: all code types, except for Pharmacode, enabled for evaluation. Overwrites a code configuration created by AutoSetup!

Profile 2

Only changes configuration of host interface: – Data transfer rate: 38 400 bits/s – Data format: 8 data bits, no parity, 1 stop bit – Handshake: none

Profile 3

Only changes configuration of host interface: – Activation of RS 422/485 interface – SICK network protocol (standard) – Data transfer rate: 38 400 bits/s – Data format: 7 data bits, parity odd, 1 stop bit – Device number: 99

Profile 4

Only changes configuration of host interface: Reading result is output as soon as evaluation criteria are fulfilled

Profile 5

Only changes configuration of host interface: – Output of error status "ST" in separator – Output of CLV: <CR> <LF> in terminator (jumps to start of new line after each code)

Profile 6

Parameterizes CLV as master in master/slave configuration – No. of slaves: 1 – Timeout: automatic

Profile 7

As profile 6, but no. of slaves: 2

Profile 8

Parameterizes CLV as slave in master/slave configuration

Profile 9

Parameterizes CLV for pass-through mode: output of " / " and device number in header

Profile 10

Starts and ends CLV AutoSetup

Profile 11

No function for CLV 43x/44x

Profile 12

No function for CLV 43x/44x

Table 10-7: Functions of preprinted profile bar codes on card no. 8 008 085

10-40

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002