Page 127
Appendix
Operating instructions
Chapter 10
CLV 43x/44x Bar Code Scanner
10.2.10 Reading field diagram for CLV 432 Line scanner with oscillating (side reading window)
Reading field height [mm]
CLV 432-6010
100
50
Resolution 0.20 mm 0.35 mm
0
0.5 mm
-50
-100
50
0
100
150
200
250
Reading distance [mm]
Scanning frequency/reading distance characteristics: see Fig. 10-17, Page 10-20
Deflection range: see Fig. 10-18, Page 10-20
Reading conditions: see Table 10-1, Page 10-1
Fig. 10-8: CLV 432-6010: reading range (DOF) for Line scanner with oscillating mirror
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-11
Page 128
10-12 120
140
160
180
© SICK AG · Division Auto Ident · Germany · All rights reserved
Reading range (DOF) = max. reading distance minus min. reading distance
Scanning frequency/reading distance characteristics: see Fig. 10-17, Page 10-20
200 min. reading distance
220 Focus position [mm]
50°/25°
0.20 mm
Appendix
0 80
50
100
150 max. reading distance Aperture angle 50°
200
Aperture angle:
Resolution:
max. reading distance Aperture angle 25°
100
Reading conditions: see Table 10-1, Page 10-1
250
300
Reading distance [mm]
CLV 440-0010 (front reading window)
Chapter 10 Operating instructions
CLV 43x/44x Bar Code Scanner
10.2.11 Reading field diagrams for CLV 440 Line scanner (front reading window)
Fig. 10-9: CLV 440-0010: min. and max. reading distance for Line scanner as a function of the focus position at resolution 0.2 mm
8 008 568/K949/10-06-2002
Page 129
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
120
160
240
50°/25°
0.25 mm
Focus position [mm]
280 min. reading distance max. reading distance Aperture angle 50° max. reading distance Aperture angle 25°
Aperture angle:
Resolution:
Scanning frequency/reading distance characteristics: see Fig. 10-17, Page 10-20
200
Reading conditions: see Table 10-1, Page 10-1
Appendix
Reading range (DOF) = max. reading distance minus min. reading distance
0 80
50
100
150
200
250
300
350
400
Reading distance [mm]
CLV 440-0010 (front reading window)
Operating instructions Chapter 10
CLV 43x/44x Bar Code Scanner
Fig. 10-10: CLV 440-0010: min. and max. reading distance for Line scanner as a function of the focus position at resolution 0.25 mm
10-13
Page 130
10-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
180
Reading range (DOF) = max. reading distance minus min. reading distance
130
280
50°/25°
0.35 mm
330 Focus position [mm] min. reading distance max. max. reading reading distance distance Aperture Aperture angle angle 50 25°° max. reading reading distance distance Aperture angle 25°° Aperture angle 25
Aperture angle:
Resolution:
Scanning frequency/reading distance characteristics: see Fig. 10-17, Page 10-20
230
Reading conditions: see Table 10-1, Page 10-1
Appendix
0 80
100
200
300
400
500
600
Reading distance [mm]
CLV 440-0010 (front reading window)
Chapter 10 Operating instructions
CLV 43x/44x Bar Code Scanner
Fig. 10-11: CLV 440-0010: min. and max. reading distance for Line scanner as a function of the focus position at resolution 0.35 mm
8 008 568/K949/10-06-2002
Page 131
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
120
160
200
280
320
50°/25°
0.50 mm
360 400 Focus position [mm] min. reading distance max. max.reading readingdistance distanc °° Aperture Apertureangle angle50 25 max. max.reading readingdistance distanc °° Aperture Apertureangle angle25 25
Aperture angle:
Resolution:
Scanning frequency/reading distance characteristics: see Fig. 10-17, Page 10-20
240
Reading conditions: see Table 10-1, Page 10-1
Appendix
Reading range (DOF) = max. reading distance minus min. reading distance
0 80
100
200
300
400
500
600
700
Reading distance [mm]
CLV 440-0010 (front reading window)
Operating instructions Chapter 10
CLV 43x/44x Bar Code Scanner
Fig. 10-12: CLV 440-0010: min. and max. reading distance for Line scanner as a function of the focus position at resolution 0.50 mm
10-15
Page 132
Appendix
Chapter 10
Operating instructions CLV 43x/44x Bar Code Scanner
Reading field height [mm]
CLV 440-0010 (front reading window)
Resolution:
1.00 mm
Aperture angle: Scanning frequency: Focus position:
800 Hz
800
1000
50° 400 mm
500 400 300 200 100 0 -100
-200
-300 -400 -500
0
200
400
600
Reading distance [mm] Scanning frequency/reading distance characteristics: see Fig. 10-17, Page 10-20
Reading conditions: see Table 10-1, Page 10-1
Fig. 10-13: CLV 440-0010: reading range (DOF) for Line scanners at resolution 1.0 mm
10-16
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 133
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
200
240
Deflection range: see Fig. 10-18, Page 10-20
Scanning frequency/reading distance characteristics: see Fig. 10-17, Page 10-20
280 Focus position [mm]
Appendix
Reading range (DOF) = max. reading distance minus min. reading distance
0 80
50
100
150 min. reading distance
200
160
50°/25°
0.25 mm max. reading max. readingdistance distanc Aperture angle Aperture angle25 25°°
Aperture angle:
Resolution:
max. reading reading distance max. distanc Aperture angle50 25°° Aperture angle
120
Reading conditions: see Table 10-1, Page 10-1
250
300
Reading distance [mm]
CLV 440-6010 (side reading window)
Operating instructions Chapter 10
CLV 43x/44x Bar Code Scanner
10.2.12 Reading field diagrams for CLV 440 Line scanner with oscillating mirror (side reading window)
Fig. 10-14: CLV 440-6010: min. and max. reading distance for Line scanner with oscillating mirror as a function of the focus position at resolution 0.25 mm
10-17
Page 134
10-18
© SICK AG · Division Auto Ident · Germany · All rights reserved
160
200
Reading range (DOF) = max. reading distance minus min. reading distance
120
240
320 min. reading distance
Deflection range: see Fig. 10-18, Page 10-20
50°/25°
0.35 mm
360 400 Focus position [mm] max. max. reading readingdistance distanc Apertureangle angle50 25 °° Aperture max. max.reading readingdistance distanc °° Aperture Apertureangle angle25 25
Aperture angle:
Resolution:
Scanning frequency/reading distance characteristics: see Fig. 10-17, Page 10-20
280
Reading conditions: see Table 10-1, Page 10-1
Appendix
0 80
50
100
150
200
250
300
350
400
450
Reading distance [mm]
CLV 440-6010 (side reading window)
Chapter 10 Operating instructions
CLV 43x/44x Bar Code Scanner
Fig. 10-15: CLV 440-6010: min. and max. reading distance for Line scanner with oscillating mirror as a function of the focus position at resolution 0.35 mm
8 008 568/K949/10-06-2002
Page 135
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
160
200
240
280
320
Deflection range: see Fig. 10-18, Page 10-20
Scanning frequency/reading distance characteristics: see Fig. 10-17, Page 10-20
360 400 Focus position [mm] min. reading distance
Appendix
Reading range (DOF) = max. reading distance minus min. reading distance
0 80
100
200
300
400
50°/25°
0.50 mm max. max. reading readingdistance distanc Apertureangle angle50 25 °° Aperture
Aperture angle:
Resolution:
500
120
Reading conditions: see Table 10-1, Page 10-1 max. max.reading readingdistance distanc °° Aperture Apertureangle angle25 25
600
Reading distance [mm]
CLV 440-6010 (side reading window)
Operating instructions Chapter 10
CLV 43x/44x Bar Code Scanner
Fig. 10-16: CLV 440-6010: min. and max. reading distance for Line scanner with oscillating mirror as a function of the focus position at resolution 0.50 mm
10-19
Page 136
Appendix
Chapter 10
Operating instructions CLV 43x/44x Bar Code Scanner
10.2.13 CLV 43x/440 characteristics field of scanning frequency l
Scanning frequency [Hz] 800
Resolution
700
0.20 mm 0.25 mm
600
0.35 mm
500
0.50 mm
400 300 200 100 0
0
100
200
300
400
500
600
700
800
Reading distance [mm] Reading conditions: see Table 10-1, Page 10-1 Fig. 10-17: CLV 43x/440: scanning frequency characteristic as a function of the reading distance and resolution
10.2.14 Deflection range of Line scanner with oscillating mirror
Deflection range [mm]
CLV 440-6010: focus position F = 280 mm
400 300 200
20
40 mm m 5 . 0 5m 0.3
100 0 -100 -200 -200
-100
0
100
200
300
400
500
Reading distance [mm] Fig. 10-18: CLV 430-/440-6010: deflection range as a function of the reading distance, deflection angle and resolution
10-20
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002