Page 1

f o r o n e C L V 21 x , C L V 2 2 x o r C L V 2 3 x / 2 5 x / 2 8 x

T E C H N I C A L

I N F O R M A T I O N

AMV 30-041 Connection Module

The AMV 30-041 connection module (below referred as "AMV"), is used to connect one SICK bar code scanner of the CLV 21x/22x or CLV 23x/25x/28x series to the peripheral devices (Host/PLC/sensor) and to the required operating voltage. The AMV realizes the direct connection to the host (point to point) as well as the wiring of simple bus structures (e.g. SICK network). The device supportes all types of host interfaces of the bar code scanners and the function inputs and outputs, too.

1. Features • Terminal strips for connection of the bar code scanner • Internal D Sub connector for access to terminal interface of bar code scanner (operating and paramatrization) • Internal control indicator and fuse for DC 24 V operating voltage • Integrated and switchable current sources to convert the CL 20 mA host interface (passive - active (AMV) - passive) • Connecting and forwarding of operating voltage (knot) • Cable routing and cable clamping via PG conduit thread

2. Scope of delivery • AMV 30-041 connection module for wall mounting without cables • Notes on device • this Technical information "AMV 30-041 Connection Module"

3. System requirements The following is needed to set up and operate the AMV:

w DC 24 V voltage supply to IEC 742 (control voltage) w A PC with “CLV Setup“ software (SICK) for access to the terminal interface of the bar code scanner w a RS 232 interface cable (with 9pin D Sub socket for AMV), e.g. no. 2 014 054

Page 2

AMV 30-041 Connection Module

Technical Information

4. Assembly Ø Mount the AMV near the bar code scanner. Therefore use the four fixing holes in the screw well (corresponding hole dimensions see fig. 9, page 7). Suitable screw diameter: up to 4 mm. Recommended cable lenghts between the CLV and the host: Type of interface

Data transmission rate

Distance to host

CL 20 mA max. 9,600 Bit/s max. 1,000 m

RS 232 up to 19,200 Bit/s 38,400 to 57,600 Bit/s max. 10 m max. 3 m

RS 422/4851)

max. 38,400 Bit/s max. 57,600 Bit/s max. 1,200 m max. 500 m

1) it must be ensured that the correct cable terminations are used

Table 1

5. Design

➊

➋

➌ ➍

➎

➏

➓

➒

➐

➑

Key: ➊ Terminal strips KL to wire the data interface and the function interfaces ➋ DIL switches S1 and S2 for internal configuration of the host interface ➌ LED indicator for operating voltage ➍ Screw well with fixing hole, dia. 4.5 mm ➎ Fuse (operating voltage) ➏ Terminal strips for DC 24 V operating voltage ➐ PG 11 conduit thread ➑ LED indicator for switchable current source (CL 20 mA) ➒ 9pin D Sub socket for service ➓ "Term 1" D Sub plug, 9pin and terminal strip (for access to the terminal interface of the bar code scanner)

Fig. 1. Construction of the AMV 30-041

Overview: functions of S 1 and S 2 DIL switches DIL

Function

Position for stand alone network

DIL

Function

Position for stand alone network

S 1.1

KL 3: bridge from R– to T–

OFF

ON

S 2.1

-

OFF

OFF

S 1.2

KL 3: bridge from T+ zu R+

OFF

ON

S 2.2

-

OFF

OFF

S 1.3

Bridge T+, KL 3 to Pin 3, KL 8

ON

ON

S 2.3

-

OFF

OFF

S 1.4

Bridge T–, KL 3 to Pin 4, KL 8

ON

ON

S 2.4

Bridge Sen., KL 4 to Sen., KL 9

ON

ON OFF

S 1.5

Bridge R+, KL 3 to Pin 5, KL 8

ON

ON

S 2.5

Bridge T–, KL 3 to GND

OFF/ON2)

S 1.6

Bridge R–, KL 3 to Pin 6, KL 8

ON

ON

S 2.6

-

OFF

OFF

S 1.7

Termination Term–

OFF/ON1)

OFF/ON1)

S 2.7

-

OFF

OFF

Termination Term+

OFF/ON1)

OFF/ON1)

Bridge R–, KL 3 to GND

OFF/ON2)

OFF

S 1.8

1) optional switchable

S 2.8

2) for switching the current sources of CL 20 mA interface

Table 2

2

© SICK AG · Auto Ident · Germany · All rights reserved

8 008 165/I938/12-2000

Page 3

Technical Information

AMV 30-041 Connection Module

6. Electrical Installation 6.1 Terminal assignment (overview) Terminal block KL 1

Terminal block KL 2

Terminal

1

3

1

Signal

+24V GND (0V)

Shield

+24V GND (0V)

2

2

Signal

1

2

3

+24V GND (0V)

4

Sensor

5

1

Signal

+24V GND (0V)

2

1

Shield

Shield GND (0V)

-

Dev. Rdy.

6

1

GND (0V)

Shield GND (0V)

3

4

5

6

IN0

-

Read GND Result (0V)

3

4

5

6

R+ RxD

R–

T+ TxD

T–

2

3

4

5

6

I+ R+ I+ T+ 20mA 20mA 20mA 20mA

1

2

3

+24V +24V GND (0V)

4

5

6

GND (0V)

RxD/ IN1

TxD/ IN2

Terminal block KL 9

Terminal block KL 8 Terminal

1

3

4

5

6

1

Signal

Shield GND (0V)

-

-

-

+24V GND (0V)

2

2

Terminal block KL 7

Terminal block KL 6 Terminal

3

Terminal block KL 5

Terminal block KL 4 Terminal

Terminal block KL 3

2

Terminal block KL 13

3

4

5

6

1

2

3

Sensor

-

-

GND (0V)

RxD

TxD

GND (0V)

Fig. 2. Terminal assignment of AMV 30-041

For wiring the AMV you are supported by the connection diagram fixed inside the cover of device as well as by the connecting diagrams and notes in this chapter.

IMPORTANT

The AMV should be installed by trained personnel only. Observe the applicable safety specifications at all times when carrying out work on electrical equipment!

• The external power supply that supplies the AMV with the DC 24 V operating voltage should provide the following permanent power output by nominal voltage: For device

Power output

Required wire cross-section

CLV 21x/22x approx. 6 W at least 0.09 mm2

CLV23x to 28x approx. 15 W at least 0.28 mm2

Table 3

• The AMV is not suitable for supplying a bar code scanner with integrated heating

ATTENTION

The output circuit of the power supply must be electrically insulated to the input circuit as per IEC 742 by means of double insulation and a safety isolating transformer.

• The routed cables are clamped by the PG conduit threads • Connect the host interface of the bar code scanner to the host using shielded cables (to fulfill the EMC requirements). See table 1 for the maximum cable lengths • To prevent interferences, do not lay the data cables over a long distance parallel to power supply and motor cables, e.g. in cable ducts • Sick recommends to connect the shield only at one side

8 008 165/I938/12-2000

© SICK AG · Auto Ident · Germany · All rights reserved

3

Page 4

AMV 30-041 Connection Module

Technical Information

6.2 Connection procedure 1. Configuring the AMV: Incorrect setting of the DIL switches S1 and S2 (host interface) may destroy internal modules in the connected bar code scanner. ATTENTION

Basic setting of all switches: OFF. Overview about functions: table 2, page 2 Ø Configurate the host interface (various types!) inside of the AMV with the S1 and S2 DIL switches (see corresponding connection diagram on page 5 to 7) 2. Connect the AMV to the CLV, to the host and the external sensors: Ø Remove the covering on the cables to be connected approx. 100 mm, strip the insulation on the wires approx. 5 mm. Insert the cables in the PG conduit threads and connect them to the terminal strips. For terminal strip allocation see connecting diagrams. For wire cross-section see table 3, page 3 Ø Check finally the wiring before applying the DC 24 V operating voltage Ø Unused inlets must be sealed with blank covers (delivered with the AMV) to order to reach the enclosure rating IP 65 Ø For access to the terminal interface of the bar code scanner (operating menue) connect the PC (Port „COM x“) to the "Term 1" D Sub plug, 9pin inside the AMV Ø Set the communication parameters of the PC in the “CLV Setup“ software to: 2,400 Bit/s, 8 data bits, no parity, 1 stop bit

IN 1

IN 2

GND Read Result

1

3

2

4

5

6

IN 2

IN 0

121212121212

KL 7 121212121212

123 12312 1212 1212 1212 1212 12 1

2

IN 2

INGND

GND

KL 6

IN 1

Device Ready

6

5

4

3

4

5

6

12121231231212

1231212 KL 4 1212123

GND

Read Result

IN 0

Device Ready

PLC

6

CLV

3

0 V = GND = optional cable

1

Sensor

OFF

KL 2

ON

24 V out

2

3

2

KL 9

7

8

R.Result

Sensor

GND

+24 V

3

5

2

S2

4

1

Sensor

1

Shield

24 V

3

GND/0V

0V

2

24 V

12 1212 1212 12 24 V

1

GND/0V Shield

12 12 12 12 12 12 12 12 12 12 12 12 12

0V

24 V

Sensor

Term 1 KL 1

6

5

4

IN 0

3

2

Device Ready

1

INGND

TxD (Term)

3

GND

2 3 5

RxD (Term)

2

24 V in

3

Sensor

1 = RxD 2 = TxD 3 = GND

12 1212 12123 123

2

„Term 1“ +24 V

TxD (Term)

RxD (Term)

GND

1

KL 13 1

KL 13

12 1212 1212 1212 12123 123123 123 12121212123123 KL 5

IN 1

CLV

Shield

6.3 Connection of function inputs/outputs, operating voltage and terminal interface

S 2.4 to ON!

Fig. 3. Allocation diagram of terminal strips in the AMV 30-041 for the function interfaces, operating voltage and terminal interface

4

© SICK AG · Auto Ident · Germany · All rights reserved

8 008 165/I938/12-2000

Page 5

Technical Information

AMV 30-041 Connection Module

6.4 Connection of the host interface RS 232 interface for CLV 21x for CLV 22x

6

5

12 12 12 KL 8

12 12 KL 4

1

6

GND

TxD (Host)

CLV

RxD (Host)

2

6

GND

5

RxD (CLV)

4

4

12 12 TxD (CLV)

3

3

Shield

2

Shield

RxD (CLV)

1

TxD (Host)

2

RxD (Host)

CLV

1

Shield

TxD (CLV)

RxD (CLV)

12 1212 1212 1212 1212 1212 12 KL 7

12 123 123 1212 1212 12123 123 123 123 KL 8

6

5

4

GND

3

2

GND

Shield

1

TxD (CLV)

KL 3 123 12312 1212 1212 1212 1212 12

GND

Shield

TxD (CLV)

RxD (CLV)

GND

Shield for CLV 23x/25x/28x

Host

Host Connection principle of RS 232: S1 RxD

5 (5)

3*)

3 (6)

*)

TxD

6

7

8 for CLV 23x/25x/28x:

TxD

2

5*)

GND

1) *)= 9pin D-Sub connector

RxD GND

AMV (KL 8/7)

(Bridge from KL 3 to KL 8)

OFF

ON

1

2

3

4

5

S1 DIL position S 1.3 ON S 1.5 ON

Host (PC)1)

Fig. 4. Allocation diagram of terminal strips in the AMV 30-041 for host interface (RS 232)

5

6

ð T– (Host)

KL 9

Host

Connection principle of RS 422:

RS 422 line termination: To improve the signal-to-noise ratio terminating resistors can be switch to the receiver of the bar code scanner, if necessary. AMV 4 GND

3

221 Ω

392 Ω

R–

392 Ω R+

(Bridge from KL 3 to KL 8)

S1 DIL position S 1.7 ON Term– S 1.8 ON Term+

ð

S1 DIL position S 1.3 ON S 1.4 ON S 1.5 ON S 1.6 ON

Term 422

1

2

3

4

5

6

7

8

S1

OFF

4

T+ (Host)

R+ (Host)

KL 4

CLV

ON

R– (CLV)

3

T– (CLV)

2

R+ (CLV)

T+ (CLV)

1

R– (Host)

R–

T+

R+

GND

6

ð

ð Shield

Shield

5

4

Shield

3

ð

2

12 12123 12312 12 12 1212 12123 123123 12312 1212 12 KL 8

KL 6

T–

1

GND

1212312121212

KL 3 12 12123 12312 1212 1212 1212 12

GND

T– (CLV)

T+ (CLV)

R– (CLV)

R+ (CLV)

GND

KL 7

T+ T– R+ R–

3

GND

2

AMV KL 8

4 5 6

ð

R+ R–

ð

Shield

RS 422 interface

T+ T– GND Host effected connection Fig. 5. Allocation diagram of terminal strips in the AMV 30-041 for host interface (RS 422)

8 008 165/I938/12-2000

© SICK AG · Auto Ident · Germany · All rights reserved

5

Page 6

AMV 30-041 Connection Module

Technical Information

R– (CLV)

T– (CLV)

T+ (CLV)

R+ (CLV)

ð

KL 9

Host

Connection principle of CL 20 mA: (passive to active):

OFF

1

2

3

4

5

6

7

8

S 1 DIL position S 1.3 ON S 1.4 ON S 1.5 ON S 1.6 ON

3

T+ T– R+ R–

4 5 6

ð

R+

ð

S1

ON

6

5

4

T+ (Host)

GND

KL 4

CLV

3

T– (Host)

2

R+ (Host)

ð T+

R–

R+

GND

1

ð

ð Shield

6

5

4

12 12123 123123 12312 1212 1212 12 KL 8

Shield

3

2

T–

1

KL 6

R– (Host)

12312312121212

KL 3 123 123123 12312 1212 1212 1212 12

Shield

KL 7

GND

T– (CLV)

R– (CLV)

T+ (CLV)

R+ (CLV)

GND

Shield

CL 20 mA interface (passive CLV via AMV to active host)

T+ T–

R–

HOST active

CLV/AMV passive KL 8

(Bridge from KL 3 to KL 8)

Fig. 6. Allocation diagram of terminal strips in the AMV 30-041 for host interface (CL 20 mA, passive to active)

CL 20 mA interface with conversion (passive CLV via active AMV to passive host)

Host

They blink briefly during data transmission: CL „T“: CLV is sending data CL „R“: CLV is receiving data

6

7

8

S2

4

5

6

ð

I+ (CLV)

5

T+ (CLV)

4

Connection principle of CL 20 mA: (passive - active - passive):

ON

(white)

CL T

CL R

(yellow)

Switching of the current sources: S 2 DIL position S 2.5 ON S 2.8 ON

I+ T+ I+ R+

5 6 3 4

ð

R+

ð

CLV

OFF

1

2

3

T–

T+

R–

R+

GND

ð Shield

6

3

R+ (CLV)

5

4

Shield

3

2

I+ (CLV)

1

GND

T+ (CLV)

T– (CLV)

R– (CLV)

R+ (CLV)

GND

Shield

ð

2

The both LEDs light up constantly when the respective cables are connected to KL 5 and no data is transmitted (rest level).

123 12312 1212 1212 1212 1212 12 1231212121212 KL 5

121212121212 KL 3 121212121212 1

ð R– (Host)

T– (Host)

R+ (Host)

T+ (Host)

GND

Shield

"CL R" and "CL T" LEDs:

T+ T–

CLV passive AMV active KL 5

R–

HOST passive

20 mA LED control indicators

Fig. 7. Allocation diagram of terminal strips in the AMV 30-041 for host interface (CL 20 mA, active to passive)

6

© SICK AG · Auto Ident · Germany · All rights reserved

8 008 165/I938/12-2000

Page 7

Technical Information

AMV 30-041 Connection Module

1231212121212

KL 3 1231212121212 1

2

3

R–/T– (CLV)

R–/T– (CLV)

R+/T+ (CLV)

R+/T+ (CLV)

12 12123 12312 1212 1212 1212 12 KL 8

KL 6

1

6

5

4

Shield

KL 7

GND

T– (CLV)

R– (CLV)

T+ (CLV)

R+ (CLV)

Shield

GND

RS 485 interface (SICK network)

3

2

5

4

6

2

Shield

GND

R–/T–

R+/T+

S 1 DIL position S 1.7 ON Term– S 1.8 ON Term+

AMV 4 GND

3

392 Ω

221 Ω

392 Ω

R–/T–

Line termination (optional switchable):

R+/T+

(Bridges from KL 3 to KL 8)

from network

Term 422

8 7 6 5 and from R– to T–)

S 1 DIL position S 1.1 ON R–/T– S 1.2 ON R+/T+

3

4

(Brigde from R+ to T+

S 1 DIL position S 1.3 ON S 1.4 ON S 1.5 ON S 1.6 ON

OFF

1

R–/T– to network

S1

ON

R+/T+

Shield

CLV

GND

KL 9

T–

T+

R–

R+

GND

Shield

KL 4 effected connection

Fig. 8. Allocation diagram of terminal strips in the AMV 30-041 for host interface (RS 485)

7. Dimensional drawing

75

163

146

129

112

95

78

61

0

25

20.5

All dimension in mm

200

120

28.5

89

188

Mounting holes, ∅ 4.5 mm in the bottom Fig. 9. Dimensions of the AMV 30-041

8 008 165/I938/12-2000

© SICK AG · Auto Ident · Germany · All rights reserved

7

Page 8

8. Technical data AMV 30-041 LED indicator (internal)

3

Fuse (operating voltage)

4 A, slow-blowing, dia. 5 mm x 20 mm

Terminal interface

9pin D Sub plug/ terminal strips

Service interface (host interface)

9pin D Sub socket

Electrical connections

Terminal strips/ 7 x PG 11 conduit thread (for cable dia. 4 to 10 mm)

Operating voltage

DC 24 V ± 20 % (to IEC 742)

Housing

Poly carbonate

Enclosure rating/ protection class

IP 65 (to DIN 40 050)/ class 3 (to VDE 0106)

Weight approx. 600 g

Ambient operating/storage temperature

0 to +40 °C/ –20 to +75 °C

Max. rel. air humidity

90%, non-condensing

Table 4

9. Ordering information Connection module Order No.

Type

1 015 435 AMV 30-041

Description

For device

Connection module with terminal strips and PG conduit threads, internal plug for access to the terminal interface of the CLV, service socket, enclosure rating IP 65

CLV 21x/22x CLV 23x to 28x

Table 5

8 008 165/I938/12-2000 · ICAI <PM 6.0> · RPF · Printed in Germany · Subject to change without prior notice · PreE2905sw

Cables and connectors Order No.

Description

Wires

Length Connection

6 010 137

Connection cable for data and function interfaces, dia. 6.5 mm, shielded, with 15pin D Sub HD socket and open end (stripped)

15

2m

CLV 21x/22x to AMV 30

2 020 262

Connection cable for data interfaces ( „Host/Term“ connection), dia. 7.4 mm, shielded, with 9pin D Sub socket and open end (stripped)

9

3m

CLV 23x...28x to AMV 30

2 013 574

Connection cable for function interfaces ( „I/O“ connection), dia. 7.4 mm, shielded, with 9pin D Sub plug and open end (stripped)

9

3m

CLV 23x...28x to AMV 30

2 014 054

RS 232 data cable, dia. 5 mm, shielded, with two 9pin D Sub sockets

3

3m

PC to AMV

6 005 695

Data cable, dia. 7 mm, twisted pair, shielded, for CL 20 mA, RS 422 and RS 232 interfaces as well as common use

4x2x 0.2 mm2 by meter

AMV 30 to host

6 007 508

Data cable, dia. 8,5 mm, twisted pair, shielded, for RS 485 network

2x2x by 0.23 mm2 meter

AMV 30 to network

6 009 438

D Sub connector housing (metal) for 9pin as well as 15pin HD inserts

-

-

6 007 335

D Sub connector insert, 9pin socket connector

-

-

-

6 007 336

D Sub connector insert, 9pin plug connector

-

-

-

6 010 019

D Sub connector insert, 15pin HD socket connector

-

-

-

6 010 020

D Sub connector insert, 15pin HD plug connector

-

-

-

Table 6