AMV 30-041 Connection Module: Technical Information, pages 1 to 8
Pages 1 to 8 of 8
The original document is the PDF (344 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Sick AMV30-061
Page 1
f o r o n e C L V 21 x , C L V 2 2 x o r C L V 2 3 x / 2 5 x / 2 8 x
T E C H N I C A L
I N F O R M A T I O N
AMV 30-041 Connection Module
The AMV 30-041 connection module (below referred as "AMV"), is used to connect one SICK bar code scanner of the CLV 21x/22x or CLV 23x/25x/28x series to the peripheral devices (Host/PLC/sensor) and to the required operating voltage. The AMV realizes the direct connection to the host (point to point) as well as the wiring of simple bus structures (e.g. SICK network). The device supportes all types of host interfaces of the bar code scanners and the function inputs and outputs, too.
1. Features • Terminal strips for connection of the bar code scanner • Internal D Sub connector for access to terminal interface of bar code scanner (operating and paramatrization) • Internal control indicator and fuse for DC 24 V operating voltage • Integrated and switchable current sources to convert the CL 20 mA host interface (passive - active (AMV) - passive) • Connecting and forwarding of operating voltage (knot) • Cable routing and cable clamping via PG conduit thread
2. Scope of delivery • AMV 30-041 connection module for wall mounting without cables • Notes on device • this Technical information "AMV 30-041 Connection Module"
3. System requirements The following is needed to set up and operate the AMV:
w DC 24 V voltage supply to IEC 742 (control voltage) w A PC with “CLV Setup“ software (SICK) for access to the terminal interface of the bar code scanner w a RS 232 interface cable (with 9pin D Sub socket for AMV), e.g. no. 2 014 054
Page 2
AMV 30-041 Connection Module
Technical Information
4. Assembly Ø Mount the AMV near the bar code scanner. Therefore use the four fixing holes in the screw well (corresponding hole dimensions see fig. 9, page 7). Suitable screw diameter: up to 4 mm. Recommended cable lenghts between the CLV and the host: Type of interface
Data transmission rate
Distance to host
CL 20 mA max. 9,600 Bit/s max. 1,000 m
RS 232 up to 19,200 Bit/s 38,400 to 57,600 Bit/s max. 10 m max. 3 m
RS 422/4851)
max. 38,400 Bit/s max. 57,600 Bit/s max. 1,200 m max. 500 m
1) it must be ensured that the correct cable terminations are used
Table 1
5. Design
➊
➋
➌ ➍
➎
➏
➓
➒
➐
➑
Key: ➊ Terminal strips KL to wire the data interface and the function interfaces ➋ DIL switches S1 and S2 for internal configuration of the host interface ➌ LED indicator for operating voltage ➍ Screw well with fixing hole, dia. 4.5 mm ➎ Fuse (operating voltage) ➏ Terminal strips for DC 24 V operating voltage ➐ PG 11 conduit thread ➑ LED indicator for switchable current source (CL 20 mA) ➒ 9pin D Sub socket for service ➓ "Term 1" D Sub plug, 9pin and terminal strip (for access to the terminal interface of the bar code scanner)
Fig. 1. Construction of the AMV 30-041
Overview: functions of S 1 and S 2 DIL switches DIL
Function
Position for stand alone network
DIL
Function
Position for stand alone network
S 1.1
KL 3: bridge from R– to T–
OFF
ON
S 2.1
-
OFF
OFF
S 1.2
KL 3: bridge from T+ zu R+
OFF
ON
S 2.2
-
OFF
OFF
S 1.3
Bridge T+, KL 3 to Pin 3, KL 8
ON
ON
S 2.3
-
OFF
OFF
S 1.4
Bridge T–, KL 3 to Pin 4, KL 8
ON
ON
S 2.4
Bridge Sen., KL 4 to Sen., KL 9
ON
ON OFF
S 1.5
Bridge R+, KL 3 to Pin 5, KL 8
ON
ON
S 2.5
Bridge T–, KL 3 to GND
OFF/ON2)
S 1.6
Bridge R–, KL 3 to Pin 6, KL 8
ON
ON
S 2.6
-
OFF
OFF
S 1.7
Termination Term–
OFF/ON1)
OFF/ON1)
S 2.7
-
OFF
OFF
Termination Term+
OFF/ON1)
OFF/ON1)
Bridge R–, KL 3 to GND
OFF/ON2)
OFF
S 1.8
1) optional switchable
S 2.8
2) for switching the current sources of CL 20 mA interface
Table 2
2
© SICK AG · Auto Ident · Germany · All rights reserved
8 008 165/I938/12-2000
Page 3
Technical Information
AMV 30-041 Connection Module
6. Electrical Installation 6.1 Terminal assignment (overview) Terminal block KL 1
Terminal block KL 2
Terminal
1
3
1
Signal
+24V GND (0V)
Shield
+24V GND (0V)
2
2
Signal
1
2
3
+24V GND (0V)
4
Sensor
5
1
Signal
+24V GND (0V)
2
1
Shield
Shield GND (0V)
-
Dev. Rdy.
6
1
GND (0V)
Shield GND (0V)
3
4
5
6
IN0
-
Read GND Result (0V)
3
4
5
6
R+ RxD
R–
T+ TxD
T–
2
3
4
5
6
I+ R+ I+ T+ 20mA 20mA 20mA 20mA
1
2
3
+24V +24V GND (0V)
4
5
6
GND (0V)
RxD/ IN1
TxD/ IN2
Terminal block KL 9
Terminal block KL 8 Terminal
1
3
4
5
6
1
Signal
Shield GND (0V)
-
-
-
+24V GND (0V)
2
2
Terminal block KL 7
Terminal block KL 6 Terminal
3
Terminal block KL 5
Terminal block KL 4 Terminal
Terminal block KL 3
2
Terminal block KL 13
3
4
5
6
1
2
3
Sensor
-
-
GND (0V)
RxD
TxD
GND (0V)
Fig. 2. Terminal assignment of AMV 30-041
For wiring the AMV you are supported by the connection diagram fixed inside the cover of device as well as by the connecting diagrams and notes in this chapter.
IMPORTANT
The AMV should be installed by trained personnel only. Observe the applicable safety specifications at all times when carrying out work on electrical equipment!
• The external power supply that supplies the AMV with the DC 24 V operating voltage should provide the following permanent power output by nominal voltage: For device
Power output
Required wire cross-section
CLV 21x/22x approx. 6 W at least 0.09 mm2
CLV23x to 28x approx. 15 W at least 0.28 mm2
Table 3
• The AMV is not suitable for supplying a bar code scanner with integrated heating
ATTENTION
The output circuit of the power supply must be electrically insulated to the input circuit as per IEC 742 by means of double insulation and a safety isolating transformer.
• The routed cables are clamped by the PG conduit threads • Connect the host interface of the bar code scanner to the host using shielded cables (to fulfill the EMC requirements). See table 1 for the maximum cable lengths • To prevent interferences, do not lay the data cables over a long distance parallel to power supply and motor cables, e.g. in cable ducts • Sick recommends to connect the shield only at one side
8 008 165/I938/12-2000
© SICK AG · Auto Ident · Germany · All rights reserved
3
Page 4
AMV 30-041 Connection Module
Technical Information
6.2 Connection procedure 1. Configuring the AMV: Incorrect setting of the DIL switches S1 and S2 (host interface) may destroy internal modules in the connected bar code scanner. ATTENTION
Basic setting of all switches: OFF. Overview about functions: table 2, page 2 Ø Configurate the host interface (various types!) inside of the AMV with the S1 and S2 DIL switches (see corresponding connection diagram on page 5 to 7) 2. Connect the AMV to the CLV, to the host and the external sensors: Ø Remove the covering on the cables to be connected approx. 100 mm, strip the insulation on the wires approx. 5 mm. Insert the cables in the PG conduit threads and connect them to the terminal strips. For terminal strip allocation see connecting diagrams. For wire cross-section see table 3, page 3 Ø Check finally the wiring before applying the DC 24 V operating voltage Ø Unused inlets must be sealed with blank covers (delivered with the AMV) to order to reach the enclosure rating IP 65 Ø For access to the terminal interface of the bar code scanner (operating menue) connect the PC (Port „COM x“) to the "Term 1" D Sub plug, 9pin inside the AMV Ø Set the communication parameters of the PC in the “CLV Setup“ software to: 2,400 Bit/s, 8 data bits, no parity, 1 stop bit
IN 1
IN 2
GND Read Result
1
3
2
4
5
6
IN 2
IN 0
121212121212
KL 7 121212121212
123 12312 1212 1212 1212 1212 12 1
2
IN 2
INGND
GND
KL 6
IN 1
Device Ready
6
5
4
3
4
5
6
12121231231212
1231212 KL 4 1212123
GND
Read Result
IN 0
Device Ready
PLC
6
CLV
3
0 V = GND = optional cable
1
Sensor
OFF
KL 2
ON
24 V out
2
3
2
KL 9
7
8
R.Result
Sensor
GND
+24 V
3
5
2
S2
4
1
Sensor
1
Shield
24 V
3
GND/0V
0V
2
24 V
12 1212 1212 12 24 V
1
GND/0V Shield
12 12 12 12 12 12 12 12 12 12 12 12 12
0V
24 V
Sensor
Term 1 KL 1
6
5
4
IN 0
3
2
Device Ready
1
INGND
TxD (Term)
3
GND
2 3 5
RxD (Term)
2
24 V in
3
Sensor
1 = RxD 2 = TxD 3 = GND
12 1212 12123 123
2
„Term 1“ +24 V
TxD (Term)
RxD (Term)
GND
1
KL 13 1
KL 13
12 1212 1212 1212 12123 123123 123 12121212123123 KL 5
IN 1
CLV
Shield
6.3 Connection of function inputs/outputs, operating voltage and terminal interface
S 2.4 to ON!
Fig. 3. Allocation diagram of terminal strips in the AMV 30-041 for the function interfaces, operating voltage and terminal interface
4
© SICK AG · Auto Ident · Germany · All rights reserved
8 008 165/I938/12-2000
Page 5
Technical Information
AMV 30-041 Connection Module
6.4 Connection of the host interface RS 232 interface for CLV 21x for CLV 22x
6
5
12 12 12 KL 8
12 12 KL 4
1
6
GND
TxD (Host)
CLV
RxD (Host)
2
6
GND
5
RxD (CLV)
4
4
12 12 TxD (CLV)
3
3
Shield
2
Shield
RxD (CLV)
1
TxD (Host)
2
RxD (Host)
CLV
1
Shield
TxD (CLV)
RxD (CLV)
12 1212 1212 1212 1212 1212 12 KL 7
12 123 123 1212 1212 12123 123 123 123 KL 8
6
5
4
GND
3
2
GND
Shield
1
TxD (CLV)
KL 3 123 12312 1212 1212 1212 1212 12
GND
Shield
TxD (CLV)
RxD (CLV)
GND
Shield for CLV 23x/25x/28x
Host
Host Connection principle of RS 232: S1 RxD
5 (5)
3*)
3 (6)
*)
TxD
6
7
8 for CLV 23x/25x/28x:
TxD
2
5*)
GND
1) *)= 9pin D-Sub connector
RxD GND
AMV (KL 8/7)
(Bridge from KL 3 to KL 8)
OFF
ON
1
2
3
4
5
S1 DIL position S 1.3 ON S 1.5 ON
Host (PC)1)
Fig. 4. Allocation diagram of terminal strips in the AMV 30-041 for host interface (RS 232)
5
6
ð T– (Host)
KL 9
Host
Connection principle of RS 422:
RS 422 line termination: To improve the signal-to-noise ratio terminating resistors can be switch to the receiver of the bar code scanner, if necessary. AMV 4 GND
3
221 Ω
392 Ω
R–
392 Ω R+
(Bridge from KL 3 to KL 8)
S1 DIL position S 1.7 ON Term– S 1.8 ON Term+
ð
S1 DIL position S 1.3 ON S 1.4 ON S 1.5 ON S 1.6 ON
Term 422
1
2
3
4
5
6
7
8
S1
OFF
4
T+ (Host)
R+ (Host)
KL 4
CLV
ON
R– (CLV)
3
T– (CLV)
2
R+ (CLV)
T+ (CLV)
1
R– (Host)
R–
T+
R+
GND
6
ð
ð Shield
Shield
5
4
Shield
3
ð
2
12 12123 12312 12 12 1212 12123 123123 12312 1212 12 KL 8
KL 6
T–
1
GND
1212312121212
KL 3 12 12123 12312 1212 1212 1212 12
GND
T– (CLV)
T+ (CLV)
R– (CLV)
R+ (CLV)
GND
KL 7
T+ T– R+ R–
3
GND
2
AMV KL 8
4 5 6
ð
R+ R–
ð
Shield
RS 422 interface
T+ T– GND Host effected connection Fig. 5. Allocation diagram of terminal strips in the AMV 30-041 for host interface (RS 422)
8 008 165/I938/12-2000
© SICK AG · Auto Ident · Germany · All rights reserved
5
Page 6
AMV 30-041 Connection Module
Technical Information
R– (CLV)
T– (CLV)
T+ (CLV)
R+ (CLV)
ð
KL 9
Host
Connection principle of CL 20 mA: (passive to active):
OFF
1
2
3
4
5
6
7
8
S 1 DIL position S 1.3 ON S 1.4 ON S 1.5 ON S 1.6 ON
3
T+ T– R+ R–
4 5 6
ð
R+
ð
S1
ON
6
5
4
T+ (Host)
GND
KL 4
CLV
3
T– (Host)
2
R+ (Host)
ð T+
R–
R+
GND
1
ð
ð Shield
6
5
4
12 12123 123123 12312 1212 1212 12 KL 8
Shield
3
2
T–
1
KL 6
R– (Host)
12312312121212
KL 3 123 123123 12312 1212 1212 1212 12
Shield
KL 7
GND
T– (CLV)
R– (CLV)
T+ (CLV)
R+ (CLV)
GND
Shield
CL 20 mA interface (passive CLV via AMV to active host)
T+ T–
R–
HOST active
CLV/AMV passive KL 8
(Bridge from KL 3 to KL 8)
Fig. 6. Allocation diagram of terminal strips in the AMV 30-041 for host interface (CL 20 mA, passive to active)
CL 20 mA interface with conversion (passive CLV via active AMV to passive host)
Host
They blink briefly during data transmission: CL „T“: CLV is sending data CL „R“: CLV is receiving data
6
7
8
S2
4
5
6
ð
I+ (CLV)
5
T+ (CLV)
4
Connection principle of CL 20 mA: (passive - active - passive):
ON
(white)
CL T
CL R
(yellow)
Switching of the current sources: S 2 DIL position S 2.5 ON S 2.8 ON
I+ T+ I+ R+
5 6 3 4
ð
R+
ð
CLV
OFF
1
2
3
T–
T+
R–
R+
GND
ð Shield
6
3
R+ (CLV)
5
4
Shield
3
2
I+ (CLV)
1
GND
T+ (CLV)
T– (CLV)
R– (CLV)
R+ (CLV)
GND
Shield
ð
2
The both LEDs light up constantly when the respective cables are connected to KL 5 and no data is transmitted (rest level).
123 12312 1212 1212 1212 1212 12 1231212121212 KL 5
121212121212 KL 3 121212121212 1
ð R– (Host)
T– (Host)
R+ (Host)
T+ (Host)
GND
Shield
"CL R" and "CL T" LEDs:
T+ T–
CLV passive AMV active KL 5
R–
HOST passive
20 mA LED control indicators
Fig. 7. Allocation diagram of terminal strips in the AMV 30-041 for host interface (CL 20 mA, active to passive)
6
© SICK AG · Auto Ident · Germany · All rights reserved
8 008 165/I938/12-2000
Page 7
Technical Information
AMV 30-041 Connection Module
1231212121212
KL 3 1231212121212 1
2
3
R–/T– (CLV)
R–/T– (CLV)
R+/T+ (CLV)
R+/T+ (CLV)
12 12123 12312 1212 1212 1212 12 KL 8
KL 6
1
6
5
4
Shield
KL 7
GND
T– (CLV)
R– (CLV)
T+ (CLV)
R+ (CLV)
Shield
GND
RS 485 interface (SICK network)
3
2
5
4
6
2
Shield
GND
R–/T–
R+/T+
S 1 DIL position S 1.7 ON Term– S 1.8 ON Term+
AMV 4 GND
3
392 Ω
221 Ω
392 Ω
R–/T–
Line termination (optional switchable):
R+/T+
(Bridges from KL 3 to KL 8)
from network
Term 422
8 7 6 5 and from R– to T–)
S 1 DIL position S 1.1 ON R–/T– S 1.2 ON R+/T+
3
4
(Brigde from R+ to T+
S 1 DIL position S 1.3 ON S 1.4 ON S 1.5 ON S 1.6 ON
OFF
1
R–/T– to network
S1
ON
R+/T+
Shield
CLV
GND
KL 9
T–
T+
R–
R+
GND
Shield
KL 4 effected connection
Fig. 8. Allocation diagram of terminal strips in the AMV 30-041 for host interface (RS 485)
7. Dimensional drawing
75
163
146
129
112
95
78
61
0
25
20.5
All dimension in mm
200
120
28.5
89
188
Mounting holes, ∅ 4.5 mm in the bottom Fig. 9. Dimensions of the AMV 30-041
8 008 165/I938/12-2000
© SICK AG · Auto Ident · Germany · All rights reserved
7
Page 8
8. Technical data AMV 30-041 LED indicator (internal)
3
Fuse (operating voltage)
4 A, slow-blowing, dia. 5 mm x 20 mm
Terminal interface
9pin D Sub plug/ terminal strips
Service interface (host interface)
9pin D Sub socket
Electrical connections
Terminal strips/ 7 x PG 11 conduit thread (for cable dia. 4 to 10 mm)
Operating voltage
DC 24 V ± 20 % (to IEC 742)
Housing
Poly carbonate
Enclosure rating/ protection class
IP 65 (to DIN 40 050)/ class 3 (to VDE 0106)
Weight approx. 600 g
Ambient operating/storage temperature
0 to +40 °C/ –20 to +75 °C
Max. rel. air humidity
90%, non-condensing
Table 4
9. Ordering information Connection module Order No.
Type
1 015 435 AMV 30-041
Description
For device
Connection module with terminal strips and PG conduit threads, internal plug for access to the terminal interface of the CLV, service socket, enclosure rating IP 65
CLV 21x/22x CLV 23x to 28x
Table 5
8 008 165/I938/12-2000 · ICAI <PM 6.0> · RPF · Printed in Germany · Subject to change without prior notice · PreE2905sw
Cables and connectors Order No.
Description
Wires
Length Connection
6 010 137
Connection cable for data and function interfaces, dia. 6.5 mm, shielded, with 15pin D Sub HD socket and open end (stripped)
15
2m
CLV 21x/22x to AMV 30
2 020 262
Connection cable for data interfaces ( „Host/Term“ connection), dia. 7.4 mm, shielded, with 9pin D Sub socket and open end (stripped)
9
3m
CLV 23x...28x to AMV 30
2 013 574
Connection cable for function interfaces ( „I/O“ connection), dia. 7.4 mm, shielded, with 9pin D Sub plug and open end (stripped)
9
3m
CLV 23x...28x to AMV 30
2 014 054
RS 232 data cable, dia. 5 mm, shielded, with two 9pin D Sub sockets
3
3m
PC to AMV
6 005 695
Data cable, dia. 7 mm, twisted pair, shielded, for CL 20 mA, RS 422 and RS 232 interfaces as well as common use
4x2x 0.2 mm2 by meter
AMV 30 to host
6 007 508
Data cable, dia. 8,5 mm, twisted pair, shielded, for RS 485 network
2x2x by 0.23 mm2 meter
AMV 30 to network
6 009 438
D Sub connector housing (metal) for 9pin as well as 15pin HD inserts
-
-
6 007 335
D Sub connector insert, 9pin socket connector
-
-
-
6 007 336
D Sub connector insert, 9pin plug connector
-
-
-
6 010 019
D Sub connector insert, 15pin HD socket connector
-
-
-
6 010 020
D Sub connector insert, 15pin HD plug connector
-
-
-
Table 6
Handed over by your SICK partner:
SICK AG Auto Ident Nimburger Straße 11 79276 Reute Germany Local sales offices see internet homepage http://www.sick.de
-