Spec sheet · Shackleton
Shackleton SSD 5570 Spec Sheet
Spec sheet4 pagesPDF 58 KB
All 4 pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A four-page catalog section of DC drive accessories, filed here under the 5570 diagnostic unit. Besides the hand-held 5570, it lists line reactors, an armature DC contactor, dynamic braking resistors and contacts, a control transformer, blower motor starters, AC line fuse kits, the 5590 armature voltage feedback unit and a three-phase line filter for 590 and 590+ Series drives. It helps a reader pick the right accessory and its catalog number.
- Device
- Hand-held diagnostic unit for drives p. 4
- Display
- 3-digit LCD readout p. 4
- Test points
- Access to 27 key test points on the drives p. 4
- Output
- Oscilloscope/recorder output p. 4
- Works with
- 514C and 5401 field controller p. 4
- Purpose
- Shortens commissioning time and simplifies troubleshooting p. 4
- 5590 feedback unit
- Armature voltage feedback unit for analog drives: motor voltages 100 to 550 V, IR compensation up to 11%, DIN rail mounting p. 4
- 590 line reactors
- For 590 Series three-phase controllers, 35 to 720 DC amps, 230 and 480 VAC supplies p. 1
- EMC line reactors
- CE approved, ratings to 180 A, used with EMC filters: CO466449U015, CO466449U040, CO463037, CO463038, CO463039 p. 1
- Armature DC contactor
- 3-pole DC loop contactor for 590+ frames 1 and 2: 955+ADC30, 955+ADC60, 955+ADC130, 955+ADC220 p. 1
- AC line fuse kits
- Three high speed fuses with fuseblocks, 300 to 800 A, 500 VAC: 655-FK33, 655-FK43, 655-FK53, 655-FK63, 655-FK83 p. 3
- Control transformer
- 590+ DRV option for 208 through 500 VAC supplies without 120 VAC control power; add -CX suffix to the part number p. 3
- Blower motor starter
- Manual motor circuit controller option inside 590+ DRV drives through 100 HP, 0.10 to 6.30 A ranges p. 3
- Line filter
- Three-phase line filter for 460 VAC systems and a fuse kit for it: LA048357, LA353827 p. 4
What this sheet walks you through
- Choosing a three-phase line reactor by DC amps and horsepower p. 1
- Line reactor dimensions and weights p. 1
- Selecting dynamic braking resistor kits by horsepower at 240 VDC and 500 VDC p. 2
- Selecting a dynamic braking contact kit for 590+ DRV drives p. 2
- Ordering a blower motor starter by motor current p. 3
- AC line fuse kit ratings and dimensions p. 3
Good to know
- When power is lost, the dynamic braking contactor will not close on Size 6 or larger drives. p. 2
- Dynamic braking with the armature DC contactor needs an additional braking resistor kit. p. 1
- Do not order the armature DC contactor with the Dynamic Braking Contact Option; the contact is in the assembly. p. 1
- The AC line fuse kits do not include panel mounting hardware. p. 3
- A line filter is already included in all 590+ DRVs above 100 horsepower at 500 VDC. p. 4
Questions this sheet answers
What is the SSD 5570?
A hand-held diagnostic unit with a 3-digit LCD readout that gives access to 27 key test points on the drives. p. 4
Which controllers does the 5570 diagnostic unit work with?
The 514C and 5401 field controller. p. 4
Does the 5570 have an oscilloscope output?
Yes, it has an oscilloscope/recorder output. p. 4
What does the 5590 armature voltage feedback unit do?
It isolates and attenuates motor armature voltage to levels compatible with drive input signals, for analog drives. p. 4
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
ACCESSORIES
DC Accessories Three-Phase Line Reactors
COMPACT DESIGN UL AND CSA APPROVALS THROUGH 110A RATING FOR 230 AND 480 VAC SUPPLIES
These reactors are intended for use with the 590 Series three-phase controllers. They may be used when voltage transformation or supply isolation is not required. Line reactors: – Reduce the level of voltage notching on the supply – Limit total radiated RF interference – Reduce current spikes in the supply lines during commutation of the SCR bridge. Dimensions Amps 35 70 110 180 250 360 550 720
Height (H) 4.5 (114) 5.5 (140) 5.5 (140) 13.0 (330) 15.0 (380) 15.0 (380) 15.7 (398) 15.7 (398)
Width (W) 6.1 (155) 6.1 (155) 6.1 (155) 7.5 (191) 11.0 (280) 11.0 (280) 14.5 (366) 14.5 (366)
Depth (D) 4.75 (121) 4.75 (121) 4.75 (121) 6.25 (159) 10.0 (255) 10.0 (255) 12.0 (306) 12.0 (306)
Weight 8 (3.6) 11 (5.0) 15 (6.8) 27 (12.3)
TAB TERMINAL CONNECTIONS Horsepower 230VAC 10 20 30 50 60 100 150 200
460VAC 20 40 60 100 150 200 300 400
DC Amps 35 70 110 180 250 360 550 720
Description Catalog No. Reactor 50 µH (UL/CSA) CO352378 Reactor 50 µH (UL/CSA) CO352379 Reactor 50 µH (UL/CSA) CO352380 Reactor 50 µH CO055255 Reactor 25 µH CO057960 Reactor 25 µH CO057961 Reactor 25 µH CO057962 Reactor 25 µH CO057963
All dimensions are in inches (mm) and weights are in Lb. (Kg).
Three-Phase Line Reactors for EMC These reactors are used with EMC filters (see page 26) for DC controllers that must meet CE standards.
CE APPROVED RATINGS TO 180A Three-Phase Line Reactors Size* DC Amps 15 40 70 110 180
Catalog No. CO466449U015 CO466449U040 CO463037 CO463038 CO463039
*Above 180 Amps use the standard line reactors listed above
Armature DC Contactor Option For use with 590+ frames 1 and 2, this assembly provides a 3-pole DC loop contactor (includes dynamic braking contact) that isolates the motor from the drive. Dynamic Braking requires an additional braking resistor kit. Note: Do not order with Dynamic Braking Contact Option, contact included in assembly.
22
Telephone : 704-588-3246
Fax : 704-588-3249
1 TO 100 HP Horsepower 240VDC 1 - 7.5 10 - 15 20 - 40 50
500VDC 1 - 15 20 - 30 40 - 75 100
Catalog No. 955+ADC30 955+ADC60 955+ADC130 955+ADC220
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
ROOF/PANEL MOUNTING HORSEPOWER RATED FOR EASIER SELECTION INTEGRAL COVERS FOR ADDED SAFETY 240 VDC DB Resistors Hp 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400 500
Ohms 8.6 6.04 4.6 3 2 2 1.4 1 1 0.742 0.58 0.452 0.384 0.325 0.255 0.196 0.176 0.137 0.1
Catalog No. CZ353160* CZ353161* CZ353162* CZ353163* CZ353164* CZ353165* CZ353166* CZ353167* CZ353168* CZ353169 CZ353170 CZ353171 CZ353172 CZ353173* CZ353174* CZ353175* CZ353176* CZ353177* CZ353178*
Ohms 62 36 36 20 12 10 7 7 4.5 4.5 4 2.8 2 1.71 1.28 1.11 0.768 0.72 0.504 0.38 0.38 0.288 0.23 0.23 0.2
Catalog No. CZ353134* CZ353135* CZ353136* CZ353137* CZ353138* CZ353139* CZ353140* CZ353141* CZ353142* CZ353143* CZ353144* CZ353145* CZ353146* CZ353147 CZ353148 CZ353149 CZ353150 CZ353151* CZ353152* CZ353153* CZ353154* CZ353155* CZ353156* CZ353157* CZ353158*
500 VDC DB Resistors Hp 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400 500 600 700 800 900 1000
The Dynamic Braking Resistor kits are designed for stopping a motor at full load current from base speed with 2 times motor energy, three times in rapid succession (NEMA ICS 3-302.62 Dynamic Braking Stop Option). Dynamic braking provides a low initial cost solution when motor braking can be less precise. When braking is required frequently in the application (for example, unwinds), a regenerative drive would be a better solution.
Dynamic Braking Contact 590+ DRV frames 1, 2 and 6+ require a separate dynamic braking contact kit if dynamic braking is required. The kits through 100 Hp use a four-pole AC contactor pre-wired to connect to the 590+ terminals. Above 100 Hp, kits use a single-pole DC contactor that requires 120 VAC control power to close. The dynamic braking contact must be factory installed and requires a larger panel. The Dynamic Braking Contact Kits are designed to meet NEMA dynamic braking requirements (see Dynamic Braking Resistors above).
ACCESSORIES
DC Accessories Dynamic Braking Resistors
COMPACT DESIGN
Note: When power is lost, the DB contactor will not close on Size 6 or larger drives.
500 VDC RATED MEET NEMA DYNAMIC BRAKING STANDARDS Horsepower 240VDC 1 - 10 15 - 20 25 - 30 0 - 50 150 - 700 800 - 1000
500VDC 1 - 20 30 - 40 50 - 60 75 - 100 300 - 1500 1750 - 2000
Catalog No. 955+DBC35 955+DBC70 955+DBC110 955+DBC162 955-DBC2400* 955-DBC3000*
- Factory installed option only.
Kits with an ‘*’ require an additional dynamic braking contact.
Telephone : 704-588-3246
Fax: 704-588-3249
23
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
ACCESSORIES
DC Accessories 590+ DRV Control Transformer
OPERATION WITH 208 THROUGH 500 VAC SUPPLIES MOUNTS INSIDE THE FRAME 1 AND 2 DRVS NOT NEEDED ON DRVS ABOVE 100 HP (AT 500 VDC)
The 590+ DRV Control Transformer option enables 590+ DRVs to be used in systems that do not use 120 VAC control power.
Blower Motor Starter
Add -CX suffix to the 590+ DRV part number
UL LISTING AND CSA CERTIFICATION
The 590+ DRV Blower Motor Starter Option uses a manual motor circuit controller to provide motor overload and branch circuit protection for a singleor three-phase AC blower motor. The option mounts inside 590+ DRV DC Drives through 100 HP.
INSTANTANEOUS MAGNETIC SHORT-CIRCUIT PROTECTION THERMAL OVERLOAD PROTECTION WITH ADJUSTABLE TRIP CURRENT SETTING
START/STOP-RESET SWITCHING WITH "TRIPPED" PUSHBUTTON INDICATION
NORMALLY-OPEN AUXILIARY CONTACT WIRED TO TERMINAL Ordering Information Catalog No. AMPS 0.10-0.16 0.16-0.25 0.25-0.40 0.40-0.63 0.63-1.00 1.00-1.60 1.60-2.50 2.50-4.00 4.00-6.30
Controller AC Line Fuse Kits
All Other 955-BMS160 955-BMS250 955-BMS40 955-BMS630 955-BMS11 955-BMS161 955-BMS251 955-BMS41 955-BMS631
Frame 1 & 2 955+BMS016 955+BMS025 955+BMS040 955+BMS063 955+BMS100 955+BMS160 955+BMS250 955+BMS400 955+BMS630
ALL UL LISTED OR RECOGNIZED COMPONENTS CSA CERTIFIED
The AC line fuse kits provide SCR protection for the 590+ Series controllers. Fuse kits protect drives against transients that may occur in drive supply lines. Each fuse kit contains three high speed fuses with fuseblocks. Note: (a) The customer is responsible for complying with all local codes when installing these fuse kits. Eurotherm Drives will not accept any responsibility for mounting the fuse kits improperly. (b) The kits do not include panel mounting hardware.
300 TO 800 AMPERES 500VAC COMPRESSION TERMINAL FOR CONNECTIONS Horsepower 230VAC 75 100 125 150 200
460VAC 150 200 250 300 400
Amps 300 400 500 600 800
Catalog No. 655-FK33 655-FK43 655-FK53 655-FK63* 655-FK83*
Width (W)* 8.56 (217) 9.00 (229)
Depth (D) 4.44 (113) 3.44 (87)
*Require ring terminals for connection.
H
Dimensions Fuse Kit 655-FK33, -FK353, -FK43 655-FK63, -FK83
W
24
Telephone : 704-588-3246
D
Fax : 704-588-3249
Height (H) 8.75 (222) 7.5 (191)
- Widths include minimal space for electrical clearance to equipment mounted next to the fuse kits
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
Ordering Information Description Armature voltage feedback unit
Catalog No. 5590
Diagnostic Unit 5570
3 DIGIT LCD READOUT ACCESS TO 27 TEST POINTS OSCILLOSCOPE/RECORDER OUTPUT Ordering Information Description Diagnostic unit
This unit provides a means of isolating and attenuating motor armature voltage to levels compatible with drive input signals to give cost effective voltage feedback. It is designed specifically for use with analog drives.
Catalog No. 5570
An easy to use hand held diagnostic unit. The 5570 can be used in conjunction with the 514C and 5401 field controller. It gives access to 27 key test points on the drives, rapidly decreasing commissioning time and simplifying trouble shooting.
ACCESSORIES
DC Accessories Armature Voltage Feedback Unit 5590
SUITABLE FOR MOTOR VOLTAGES 100 - 550V IR COMPENSATION UP TO 11% DIN RAIL MOUNTING BI-DIRECTIONAL OPERATION TRIM OUTPUT POTENTIOMETER
Three-Phase Line Filter
Ordering Information Description Three-phase line filter Fuse kit for three-phase line filter
Catalog No. LA048357 LA353827
The filter provides additional protection against spikes induced on the AC line by DC controllers on 460 VAC systems. It is recommended when accessories (such as blower motors) are connected to the same main supply as the controller without isolation. The completely wired fuse kit contains fuses and fuseblocks to provides branch circuit protection for the line filter. 5.00" (126mm)
RATING FOR 230 AND 480 VAC SUPPLIES 1/4 INCH TAB TERMINAL CONNECTIONS PANEL MOUNTED
Note: A line filter is included in all 590+ DRVs above 100 horsepower (at 500 VDC)
2.00" (51mm)