For the Sentech STC-1100

Page 9

STC-1100 Specifications B&W Progressive Scan CCD Camera e. Gamma Correction Switch

Gamma = 0.45 Position Gamma = 1 Position Gamma Correction Switch

4. Input/ Output Signals a. External Sync. Input Signals i) HD Input Signal Level:

2 – 5Vp-p

Termination Impedance:

75 Ω or high Impedance

Sync. Frequency:

15.734KHz + 1% (Normal Speed Progressive) 31.468KHz + 1% (Double Speed Progressive) 15.734KHz + 1% (Normal Speed 2:1 Interlace) 31.468KHz + 1% (Double Speed 2:1 Interlace)

ii) VD Input Signal Level:

2 – 5Vp-p

Termination Impedance:

75 Ω or high Impedance

Sync. Frequency:

29.97Hz (Normal Speed Progressive) 59.94Hz (Double Speed Progressive) 59.94Hz (Normal Speed 2:1 Interlace) 119.88Hz (Double Speed 2:1 Interlace)

b. Sync. Output Signals i) HD Input Signal Level:

2 Vp-p at 75 Ω termination 5 Vp-p at high impedance

9/16

Rev. 5 / November 5, 2001

Page 10

STC-1100 Specifications B&W Progressive Scan CCD Camera

Termination Impedance:

75 Ω or high Impedance

Sync. Frequency:

15.734KHz + 1% (Normal Speed Progressive) 31.468KHz + 1% (Double Speed Progressive) 15.734KHz + 1% (Normal Speed 2:1 Interlace) 31.468KHz + 1% (Double Speed 2:1 Interlace)

ii) VD Input Signal Level:

2 Vp-p at 75 Ω termination 5 Vp-p at high impedance

Termination Impedance:

75 Ω or high Impedance

Sync. Frequency:

29.97Hz (Normal Speed Progressive) 59.94Hz (Double Speed Progressive) 59.94Hz (Normal Speed 2:1 Interlace) 119.88Hz (Double Speed 2:1 Interlace)

c. Variable Integration Shutter Trigger Input Signals Low level;

0 – 0.5V

High level:

4 – 5V

Pulse duration:

Please see the section 4

5. Variable Integration Shutter Trigger Operations (Note) Double speed 2:1 interlace mode is not used in these variable integration shutter trigger operations.

IMPOTANT!:

DIPswitch No. 5 must be turned ON and No. 6 must be turned OFF when the camera operates in the “Variable Integration Shutter Trigger Mode”. a. One-pulse variable integration shutter trigger operations 1) Functions With this “one-pulse variable integration shutter trigger mode”, one trigger pulse input signal can control camera’s integration time based on its pulse duration time. In other words, the

10/16

Rev. 5 / November 5, 2001

Page 11

STC-1100 Specifications B&W Progressive Scan CCD Camera integration time starts at the falling edge of the trigger pulse then ends at its rising edge (see the drawing below). Since “XSUB” is activated in the camera at the falling edge of the trigger pulse and “XSG” is activated at the rising edge, the integration time is controlled very accurately. Video signal output is sent out from the camera at the moment “t2” period ends. “t2” starts at the rising edge of the trigger pulse and ends at the 18th internal HD pulse (2:1 interlace mode) or 33rd internal HD pulse (progressive mode) after the rising edge of the trigger pulse. Therefore, t2 is exactly 19H (2:1 interlace mode) or 34H (progressive mode) if the rising edge of the trigger pulse is synchronizing to the internal HD pulse. In the case the rising edge of the trigger pulse is not synchronizing to the internal HD pulse, this “t2” fluctuate depending on the relational timing of the two pulses as described in section 2). Iii) below. This camera provides a capability to synchronize to External HD in the variable integration shutter trigger mode. With this feature, user can easily create HD-synchronized trigger pulse for the above-mentioned operation since the internal HD synchronizes to the external HD applied to the camera. 2) Timing chart Trigger (M-Trig: No.11) T: Integration period Internal HD Td: Delay t1 t2

Video Out

11/16

Rev. 5 / November 5, 2001

Page 12

STC-1100 Specifications B&W Progressive Scan CCD Camera i) T: Integration period must be set within the following time length. Normal speed interlace:

– 16.7msec

Normal speed progressive: – 16.7msec Double speed progressive: – 8.3msec ii) t1: from the rising edge of the trigger pulse to the vertical sync. pulse Normal speed interlace:

4H + Td (5H with HD-synchronized trigger)

Normal speed progressive: 4H + Td (5H with HD-synchronized trigger) Double speed progressive: 4H + Td (5H with HD-synchronized trigger) iii)

t2: from the rising edge of the trigger pulse to the video out Normal speed interlace:

18H + Td (19H with HD-synchronized trigger)

Normal speed progressive: 33H + Td (34H with HD-synchronized trigger) Double speed progressive: 33H + Td (34H with HD-synchronized trigger) i)

Minimum trigger intervals are the following. Cycle speed of each trigger must be greater than these values. Normal speed interlace:

18msec

Normal speed progressive: 36msec Double speed progressive: 18msec

12/16

Rev. 5 / November 5, 2001

Page 13

STC-1100 Specifications B&W Progressive Scan CCD Camera b. Two-pulse variable integration shutter trigger operations 1) Functions The camera functions in this mode is exactly the same as above a. except that two trigger input pulses are required. The integration time starts at the falling edge of the first pulse (M-Trig) then it ends at the falling edge of the second pulse (S-Trig). 2) Timing chart M-Trig Tx S-Trig Tx T: Integration period

Internal HD Td: Delay t1 t2

Video Out ii)

T: Integration period must be set within the following time length. Normal speed interlace:

– 16.7msec

Normal speed progressive: – 16.7msec Double speed progressive: – 8.3msec

13/16

Rev. 5 / November 5, 2001

Page 14

STC-1100 Specifications B&W Progressive Scan CCD Camera iii)

t1: from the rising edge of the trigger pulse to the vertical sync. pulse Normal speed interlace:

4H + Td (5H with HD-synchronized trigger)

Normal speed progressive: 4H + Td (5H with HD-synchronized trigger) Double speed progressive: 4H + Td (5H with HD-synchronized trigger) iv)

t2: from the rising edge of the trigger pulse to the video out Normal speed interlace:

18H + Td (19H with HD-synchronized trigger)

Normal speed progressive: 33H + Td (34H with HD-synchronized trigger) Double speed progressive: 33H + Td (34H with HD-synchronized trigger) v)

Tx: trigger pulse width must be set between and 1msec.

vi) Minimum trigger intervals are the following. Cycle speed of each trigger must be greater than these values. Normal speed interlace:

18msec

Normal speed progressive: 36msec Double speed progressive: 18msec

6. Vertical Reset Operations a. Vertical reset operations In this “Vertical Reset Mode”, when the camera receives one VD pulse, only one field of video signal (2:1 interlace mode) or one frame of video signal (progressive mode) is sent out. 1) Turn “Sync. Mode Switch” (3.b) to “External Sync.”. 2) Turn DIP switch No. 2 (3.c.ii) to “ON (Internal or External Sync.)”. The camera switches to external mode automatically when external HD is supplied. 3) The vertical operates as “Direct Reset Mode”, 4) In the case of 2:1 interlace, even or odd field is determined by the timing of the falling edge of the Vertical reset pulse (see note on next page).

14/16

Rev. 5 / November 5, 2001

Page 15

STC-1100 Specifications B&W Progressive Scan CCD Camera b. Timing chart a) Normal and double speed 2:1 Interlace i) Odd field reset HD V.Reset VDO

9H ii) Even field reset HD V.Reset VDO

9H

(Note) Field (odd or even) determination V. Reset

HD tp1 tp3 tp2 tp4 VDO tp5 Odd

VDO

Even

15/16

Rev. 5 / November 5, 2001

Page 16

STC-1100 Specifications B&W Progressive Scan CCD Camera

Sign Definition tp1 Area to reset to Odd field tp2 Area to reset to Even field tp3 Area to reset to Odd field tp4 Prohibited area tp5 Prohibited area b) Normal and double speed progressive scan

Normal Speed 21.98s 31.68s 200 ns 200 ns

Double Speed

/8s 3 100ns 100ns

HD V.Reset VDO 9H

16/16

Rev. 5 / November 5, 2001