AD TOUCH TRACKER 16 System Operator's Manual: Chapter 1: About AD Touch Tracker 16

Pages 11 to 22 of 108, from AD TOUCH TRACKER 16 System Operator's Manual

The original document is the PDF (568 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sensormatic TouchTracker 16

Page 11

C H A P T E R

1

A B

Peel Info

C

1 Me nu

2

Ou tputOn

D 3

4

Off Clea r

Flip

5 6

Vi ew

7 Clos

Patte rn

8 e Iris

9

Op en

Cam era

Repea P atte t rn

0 Dis pla

Seq y

P rev Next

About AD TOUCH TRACKER 16 In This Chapter • • • • •

Understanding Your AD TOUCH TRACKER 16 System AD TOUCH TRACKER 16 Features AD TOUCH TRACKER 16 Equipment An Overview of the TOUCH TRACKER Modes of Operation

Page 12

Understanding Your AD TOUCH TRACKER 16 System This manual describes those features that are available to you as an AD TOUCH TRACKER 16 operator, and it provides instructions for using these features. It is up to you, however, to assimilate these features and apply them in your specific environment. Every site and situation has different concerns, capabilities, and vulnerabilities. Understanding how your AD TOUCH TRACKER 16 system works will enable you to address these concerns and overcome these vulnerabilities. Use this manual to learn how to customize your system to meet the needs of your environment. Most importantly, get comfortable using the system. The more familiar you are with the system's features and functions, the better you will be able to secure your site. Once you become comfortable using the system, you will find it a valuable - and time-saving - security and management tool.

AD TOUCH TRACKER 16 Features The AD TOUCH TRACKER 16 system enables you to oversee activity throughout your facility as it happens. This powerful overview allows you to document activity and can help you to prevent unwanted activity from taking place. The system can include either one or two camera controllers, called TOUCH TRACKERs. These TOUCH TRACKERs can control cameras simultaneously, and enable two users to operate the system concurrently. As an alternative, a single user could control both TOUCH TRACKERs at the same time for twohanded operation. Features available to AD TOUCH TRACKER 16 operators are:

1-2

•

The ability to manually call up video from individual cameras, one at a time by using a compatible quad splitter or multiplexer

•

The capability to display video from up to four cameras on one monitor simultaneously in a 2x2 format by using a quad splitter Operator’s Manual

Page 13

•

The capability to display video from up to 16 cameras on one monitor simultaneously in a 2x2 format, 3x3 format, or 4x4 format by using a multiplexer

•

The capability to single-handedly control a camera's panning and tilting movements, as well as its zoom, focus, and iris commands

•

An “Apple Peel” feature that allows a SpeedDome to run a default pattern, providing you with complete video coverage of an area

•

A SpeedDome “flip” feature that enables you to flip the SpeedDome 180° in the opposite direction it is currently looking

•

The ability to define and display Quick Views, which are immediate camera call-ups of pre-defined views, with automatic zoom and focus

•

The ability to define and run Patterns, which comprise a sequential series of pan, tilt, zoom, and focus movements from a single camera

•

The capability to incorporate up to 16 of the pre-defined Quick Views and Patterns in a Sequence, where the Quick Views and Patterns are automatically displayed one after the other on the Main monitor

•

The capability to toggle the state of up to 64 dome outputs which, if hooked up through relays, can control lights, door locks, etc., via the TOUCH TRACKER

•

The ability to define up to 64 different alarms; the alarms are triggered by dome inputs, and they automatically call up a pre-defined Quick View, Pattern, or fixed shot and/or initiate a dome output

•

The ability to clear alarms via the Main TOUCH TRACKER; the system can store up to four alarms at one time in its queue

•

Utilities that can be accessed from the TOUCH TRACKER for the following functions: reset the SpeedDome, swap the zoom and focus buttons, calibrate the TOUCH TRACKER, select a language for the TOUCH TRACKER's LCD display, and designate the Main and Call TOUCH TRACKERs

About AD TOUCH TRACKER 16

1-3

Page 14

AD TOUCH TRACKER 16 Equipment Every AD TOUCH TRACKER 16 system consists of a unique set of equipment. Some equipment is required, while other equipment is optional. The following figure shows some components typically installed for an AD TOUCH TRACKER 16 system. This simplified illustration gives only a very broad overview of the different types of equipment and how the components connect to one another.

1-4

Operator’s Manual

Page 15

Programmable and Non-Programmable Domes

SensorNet

Quad Splitter or Multiplexer

RS 232

Main Monitor

Call Monitor

A B

Peel Info Men u

C

1 2

OutputOn

Main TOUCH TRACKER

D

3 4

Off

F li p

5

Clea r

6

V iew

7 Clos

P att

8 e Iris Open

9 Cam era ern

Rep Patt eat ern

0

S eq

Dis play

Prev Nex t

SensorNet A B

Peel Info

C

1 2

O

Output n

Men u

Off

4

D

3 F li p

5

Clea r

6

V iew

7 Clos

Call TOUCH TRACKER

About AD TOUCH TRACKER 16 e

P att

8

Iris Open

9 Cam era ern

Rep Patt eat ern

0

S eq

Dis play

Prev Nex t

1-5

Page 16

1-6

•

The system's cameras enable you to monitor activity throughout a facility from a single location. You can see video from up to 16 cameras. The AD TOUCH TRACKER 16 system is compatible with programmable and non-programmable domes, PTZ cameras, and fixed cameras.

•

The TOUCH TRACKER is the device you use to select cameras and manually control their movement, as well as adjust their zoom, focus, and iris. The TOUCH TRACKER enables you to perform automated camera operations and clear system alarms. With the TOUCH TRACKER you can access the menu to program automated system functions and use the utilities.

•

If there are two TOUCH TRACKERs installed with your system, you must configure one as the Main TOUCH TRACKER and the other as the Call TOUCH TRACKER. The Main TOUCH TRACKER employs all of the functionality described in this manual. The Call TOUCH TRACKER, however, has no programming capabilities, and it cannot select a monitor display format, initiate the Sequence, or clear alarms.

•

The video monitor displays the camera's video. You may have only one monitor, you may have two monitors, or you may have a separate monitor dedicated for every camera. If a system contains two monitors, one is referred to as the Main monitor and the other as the Call monitor. The Main monitor displays video in a multiplexed format and is controlled by the Main TOUCH TRACKER. The Call monitor is dedicated for full-screen view only, and its video is controlled by the Call TOUCH TRACKER.

•

The Quad Splitter or Multiplexer is the unit that allows video to be displayed in a multiplexed format. The quad splitter enables you to see video from up to 4 cameras simultaneously on one monitor. A multiplexer enables you to see video from up to 16 cameras simultaneously on one monitor.

Operator’s Manual

Page 17

An Overview of the TOUCH TRACKER The TOUCH TRACKER, shown here, is a video control station that provides you with easy access to a variety of video control features - from basic camera control to advanced automated functions. LCD

Keypad A B

Pee l Info

Zoom Men u

C

1 2

Outp On ut

D 3

Off

4

Flip

5

Cle ar

6

Vie w

7 Clo Ir se is Ope n

8

Patt ern

9 Cam e ra

Re p Patt eat ern

0 Dis

Se q pla y

Pre v iou s

Ne xt

Focus Tracker Ball

The Tracker Ball provides variable speed control of a camera's pan and tilt. The zoom and focus buttons enable you to control a camera's zoom and focus. When used with the LCD menu, the zoom and focus buttons allow you to select the menu items displayed on the LCD. According to your own preference, you can designate which button is zoom and which is focus; the configuration shown above is the default button setup.

About AD TOUCH TRACKER 16

1-7

Page 18

The keypad contains buttons that call up video from individual cameras and control the pre-programmed movement of those cameras. It also contains the buttons for camera iris control, dome output control, and monitor display formats. It also allows you to clear dome alarms from the TOUCH TRACKER keypad. The LCD, located at the top of the keypad, displays the currently selected camera number, Pattern Number, and Quick View number. It enables you to see the numbers you enter from the keypad as you enter them. The LCD displays system prompts and messages; it also displays the menu.

Modes of Operation The TOUCH TRACKER has four different modes of operation: •

Camera control mode

•

Menu/programming mode

•

Sequence mode

•

Alarm mode

The system functions differently depending upon the mode of operation. Each of these modes is described briefly in this section.

Camera Control Mode When the TOUCH TRACKER is in the camera control mode, you can:

1-8

•

Determine the format in which the cameras are displayed on the monitor. (Refer to Chapter 2, “Monitor Display formats”)

•

Select individual cameras and display their video on the monitor. (Refer to Chapter 3, “Controlling Cameras and Their Outputs”)

•

Control cameras manually. (Refer to Chapter 3, “Controlling Cameras and Their Outputs”)

•

Initiate automatic system functions. (Refer to Chapter 3, “Controlling Cameras and Their Outputs”)

Operator’s Manual

Page 19

•

Display the ID code for the currently selected dome. (Refer to “Displaying a Dome's ID Code,” in Chapter 5.)

In the camera control mode, the currently selected camera number appears on the LCD. If there is a Quick View or a Pattern running, this is also indicated. In this mode the Tracker Ball functions as the camera pan/tilt controller, and the zoom and focus buttons control the zoom and focus of the currently selected camera.

Menu/Programming Mode You activate the menu/programming mode by pressing the Menu button on the keypad. When the TOUCH TRACKER is in the menu/programming mode, the LCD displays the available menu selections, and the Tracker Ball functions as a cursor controller, enabling you to scroll through the menu selections. The zoom and focus buttons enable you to select an item on the menu. There are always two menu items visible at one time on the LCD. Use the left button (the default “zoom” button) to select the item on the top line. Use the right button (default “focus” button) to select the item on the bottom line.

About AD TOUCH TRACKER 16

1-9

Page 20

A B

Press this button to select the top line of the LCD (in this example “Calibration”).

Cal i Def bratio n ine Seq uen ce

Pee l Info Men u

C

1 2

Outp On ut

D 3

4

Off

Flip

5

Cle ar

6

Vie w

7 Clo se Iris Ope n

8

Patt ern

9 Cam e ra

Re p Patt eat ern

0 Dis

Se q pla y

Pre v Ne xt

Press this button to select the bottom line of the LCD (in this example “Define Sequence”).

Tip: You may also use the A or B buttons on the Touch Tracker to select menu items on the LCD. Use A to select the top item on the LCD; use B to select the bottom item on the LCD.

The C and D buttons on the Touch Tracker may be used to scroll through the LCD menu. Use C to scroll to the previous menu item; use D to scroll to the next menu item.

1-10

Operator’s Manual

Page 21

In the menu/programming mode, you can perform the following activities: •

Program the Quick Views for each programmable dome. (Refer to “Defining Quick Views,” in Chapter 4.)

•

Program the Patterns for each programmable dome. (Refer to “Defining Patterns,” in Chapter 4.)

•

Assign the Quick Views, Patterns, and fixed shots to be included in the Sequence. (Refer to “Defining the Sequence” in Chapter 4.)

•

Define which inputs will trigger an alarm, and what camera action and/or output initiates when that alarm is triggered. (Refer to “Defining Dome Alarms,” in Chapter 4.)

•

Indicate which external device your system is connected to: a quad splitter, a 4-camera multiplexer, a 9-camera multiplexer, a 16-camera multiplexer, a PC, or no unit. (Refer to “Designating Which Type of Unit You Are Connected to,” in Chapter 2.)

•

Tune the Tracker Ball sensor for maximum range of motion. (Refer to “Calibrating the Tracker Ball,” in Chapter 5.)

•

Reset a SpeedDome if it is not responding as expected to TOUCH TRACKER commands. (Refer to “Resetting a Dome,” in Chapter 5.)

•

Select from 10 different languages in which to display the LCD text. (Refer to “Selecting a Language,” in Chapter 5.)

•

Assign the Main and Call TOUCH TRACKERs. (Refer to “Designating Main Versus Call TOUCH TRACKER,” in Chapter 5.)

•

Swap the functionality of the zoom and focus buttons. (Refer to “Swapping the Zoom and Focus Buttons,” in Chapter 5.)

Sequencing Mode You activate the sequencing mode by pressing the Seq button; this initiates the Sequence you defined in the menu/programming mode. The Sequence consists of up to 16 of the previously defined Quick Views and Patterns (called events). These events run one after the other on the About AD TOUCH TRACKER 16

1-11

Page 22

monitor. The sequencing mode provides you with an unattended surveillance of your facility; it runs continuously until you stop it manually. When the TOUCH TRACKER is in the sequencing mode, the LCD displays the camera number whose video appears on the monitor. It also displays the event number (1 through 16) of the Sequence is currently displaying. In addition, the LCD displays how many seconds the current event will remain on the screen until it is replaced by the next event. For more information on the sequencing mode, refer to the section “Running the Sequence,” in Chapter 3.

Alarm Mode Regardless of the current mode of the system, the TOUCH TRACKER will automatically go into the alarm mode when an alarm is triggered. When the alarm mode is active, the TOUCH TRACKER beeps intermittently for 60 seconds if you have Automatic Alarm Acknowledging enabled (or you clear the alarm by pressing the Clear button). You set up the alarms in the programming mode. When you set up an alarm you determine what will trigger the alarm, and what the alarm will do when it is triggered. The following illustration shows an example of the TOUCH TRACKER LCD in the alarm mode. Cam 3 Alarm2 Src:Cam 5 Inp3

In the previous example, there are currently two alarms active. The alarm whose information appears on the LCD was triggered by input 3 of camera 5. The video from camera 3 appears on the Main monitor. For more information on the alarm mode, refer to the section “Clearing System Alarms,” in Chapter 3.

1-12

Operator’s Manual