The text of a manual · part 7 of 7
Video Multiplexer with Video Alarm Detection Installation and Operation Manual, pages 61 to 64
Pages 61 to 64 of 64
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Page 61
52
Video Multiplexer with Video Motion Detection
Video Level
Alarm
Camera Inputs
1.0 V p-p, 75 ohms
Camera Outputs
1.0 V p-p, 75 ohms
VCR Inputs: Composite
1.0 V p-p, 75 ohms
VCR Inputs: S Video
Luma 1.0 V p-p, 75 ohms Chroma(burst)285mV p-p, 75 ohms
VCR Outputs: Composite
1.0 V p-p, 75 ohms
VCR Outputs: S Video
Luma 1.0 V p-p, 75 ohms Chroma (burst) 285mV p-p, 75 ohms
Camera Alarm Input
One input per camera. Contact or TTL/CMOS signal. Polarity selectable.
Alarm Hold Input
+5 to +15 VDC or TTL/CMOS active high signal.
Alarm Duration
4 second default. Menu selectable from 2 to 999 seconds.
Alarm Output
Normally open (NO) and normally closed (NC) contacts with shared common; 2.0 A at 30 VDC (resistive only) 1.0 A at 125 VAC (resistive only)
Display Resolution
Alarm Outputs
One output per camera, TTL/CMOS (selectable polarity).
Color Palette
16,777,216 colors (24 bits)
Gray Shades
256 (8 bits)
Full Screen Format
512x464 pixels (512x512 PAL)
2x2 Format
256x232 (256x256 PAL)
3x3 Format
170x154 (170x170 PAL)
4x4 Format
128x116 (128x128 PAL)
PIP Insert
128x116 (128x128 PAL)
Zoom Display
Interpolated 512x464 (512x512 PAL)
Page 62
Appendixes
53
Controls
General
Soft touch, rubberized push buttons with indicator lights.
Function (1 Cam)
Used in combination with other buttons to access special functions.
Full Screen (Zoom)
Selects full screen, 2x zoom display or program menu.
PIP (Up)
Selects Picture-In-Picture display or UP function.
2x2 (Down)
Selects 2x2 picture display or DOWN function.
3x3 (Left)
Selects 3x3 picture display or LEFT function.
4x4 (Right)
Selects 4x4 picture display or RIGHT function.
Live
Selects camera inputs for viewing.
Tape
Selects VCR input for viewing.
Sequence
Selects sequential camera display, either full screen or in lower right window of multicamera display.
Call
To change display on call monitor.
Camera
Selects camera for viewing or single camera record.
Page 63
54
Video Multiplexer with Video Motion Detection
Connectors
Power
2.1 mm pin-type female. Power input.
Remote
RJ11. Remote control via remote panel option or ASCII commands.
Alarms
DB37-S. Alarm control via contact or TTL/CMOS signal.
Call Mon
BNC. Video signal output to call monitor.
Main Mon
BNC. Video signal output to main monitor.
S-VHS In
S-Connector. S-Video input from VCR (color models only).
S-VHS Out
S-Connector. S-Video output to VCR (color models only).
VCR In
BNC. Composite video input from VCR.
VCR Out
BNC. Composite video output to VCR.
Cam In
BNC. Composite video input from camera.
Cam Out
BNC. Composite video output from camera (passive loop through).
Termination switches
75 ohms input impedance (75 Ω) or ∞ for looping to other equipment.
Page 64
Appendixes
55
Electrical Physical Characteristics
Power Requirement
18 Watts (center positive 12 VDC)
Dimensions
17 in (432mm) Wide 12.2 in (311mm) Deep 1.75 in (44mm) High
Unit Weight
9 lbs. (4 kg)
Shipping Weight
11 lbs. (5 kg)
Environmental Requirements
Temperature, 40 - 104° F (5 - 40° C) Humidity, 5 - 95%RH Noncondensing Operating altitude, 0 - 10,000 feet (3048 meters)
Options
Remote control panel
Kit includes: remote control panel, 50 ft. cable, desktop stand and rack mount bracket