Page 51

42

Video Multiplexer with Video Motion Detection

VIDEO LOSS ALARMS

The multiplexer detects loss of video at any connected camera input by monitoring the camera’s video sync signal. The VIDEO LOSS ALARM option controls this feature. When this option is ON (the default), the multiplexer responds to loss of camera video by alerting the operator and recording the alarm event on videotape. When the VIDEO LOSS ALARM option is OFF, video loss is NOT treated as an alarm, and no message displays. The multiplexer does the following when it detects loss of camera video: 1.

Flashes the associated Camera (1–16) light.

2.

Toggles the alarm relay.

3.

Switches the call monitor to the lost camera input and displays the VIDLOSS message.

4.

Switches the main monitor to the multicamera format (if ALARM MESSAGE DISPLAY is ON and the alarm camera is not already displayed) and displays the VIDLOSS message.

5.

Switches to the VCR ALARM RECORD TIME encoding rate.

6.

Encodes the camera as “video lost” and sends it to the VCR.

Multiple video loss alarms are processed in the order they occur. The multiplexer remains in the alarm state until ALL of the following occur: •

The ALARM DURATION time elapses.

•

The alarm hold input is released.

Page 52

Chapter 7, Special Applications

43

Chapter 7, Special Applications The features and flexibility of the multiplexer make it a powerful tool in special applications where unique capabilities are required. This section describes several ways to use the multiplexer.

SIMULTANEOUS RECORD AND PLAY

The multiplexer circuits simultaneously encode and decode video. This is referred to as “full duplex” operation, which uses two VCRs. The unit can encode camera video to one VCR while it decodes and displays video played on a second VCR. The two operations do not interfere with each other. Without this capability, camera video recording must stop while a previously recorded tape is viewed. Full duplex capability is most important in applications that demand continuous video recording of multiple cameras. It allows an operator equipped with a second video recorder to review multiplexer tapes without interrupting the recording process. Refer to Figure 2 – Multiplexer System with Two VCRs. To add a second VCR to a standard multiplexer installation: 1.

Connect a cable to “video in” on the VCR and connect the other end of this cable to the multiplexer vcr out connector. This VCR is now dedicated for tape recording.

2.

Connect another cable to the “video out” of the second VCR and the multiplexer vcr in connector. This VCR is now dedicated for tape playback.

Multiplexer operation is similar when connected to two VCRs. The difference is that recording and playback are performed by separate VCRs.

Page 53

44

Video Multiplexer with Video Motion Detection

MULTIPLEXED VIDEO TRANSMISSION

Two multiplexers can be employed to transmit video from multiple cameras over a single video communication link. The link may be coaxial cable, a microwave channel, or any other medium that supports real-time video. Where two communications links are available, simultaneous two-way video communication is possible. Multiplexed video transmission requires that one multiplexer be installed at each location. See Figure 3 – One-Way Multiplexed Video Transmission, for details. A multiplexed video link allows users at one or both ends to display local or remote cameras. Multiplexer operation is normal except that you press Function+Tape to display the remote cameras.

One-Way Video Transmission

One-way multiplexed video transmission requires two multiplexers and one video quality communication link. The link joins the vcr out connector at Site A to the vcr in connector at Site B. Both Site A and Site B can view the cameras located at Site A. Site B can view either local cameras (press Live) or the cameras located at Site A (press Function+Tape).

Two-Way Video Transmission

Two-way multiplexed video transmission requires two multiplexers and two video quality communication links. The communication links cross connect the multiplexer VCR connectors at these sites: vcr out at Site A connects to vcr in at Site B and vice versa. Both sites can view either local cameras (press Live) or the cameras located at the other site (press Function+ Tape). To establish a multiplexed video transmission link: 1.

Connect two multiplexer units as described above.

2.

Set VCR RECORD TIME on both multiplexer units to 001 HRS for NTSC/EIA units, or 002 HRS for PAL/CCIR.

3.

Press Function+Tape on each multiplexer. The multiplexer enters the video transmission mode and displays all remote cameras.

If you get a MISSING TAPE INPUT message, check the connections and make sure that vcr in is connected to vcr out on the other unit. Once the link is established, press the Live button to view local cameras, or press Function+Tape to view remote cameras.

Page 54

Appendixes

APPENDIX A ALARM CONNECTOR PIN ASSIGNMENTS

45

The alarms connector is a DB37-S. It accepts a DB37-P mating connector.

Figure 10, Alarm Connector PIN

PIN ASSIGNMENT

PIN

PIN ASSIGNMENT

1

Alarm input 1

20

Alarm output 1

2

Alarm input 2

21

Alarm output 2

3

Alarm input 3

22

Alarm output 3

4

Alarm input 4

23

Alarm output 4

5

Alarm input 5

24

Alarm output 5

6

Alarm input 6

25

Alarm output 6

7

Alarm input 7

26

Alarm output 7

8

Alarm input 8

27

Alarm output 8

9

Alarm input 9

28

Alarm output 9

10

Alarm input 10

29

Alarm output 10

11

Alarm input 11

30

Alarm output 11

12

Alarm input 12

31

Alarm output 12

13

Alarm input 13

32

Alarm output 13

14

Alarm input 14

33

Alarm output 14

15

Alarm input 15

34

Alarm output 15

16

Alarm input 16

35

Alarm output 16

17

Alarm output com

36

Alarm hold input

18

Alarm output NC

37

Autodetect VCR Speed

19

Alarm output NO

Table 1, Alarm Connector Pin Assignments

Page 55

46

Video Multiplexer with Video Motion Detection

APPENDIX B ALARM RECORDING CONTROL

Most multiplexer installations require that alarm events be documented on videotape. The multiplexer provides all of the necessary connectors and signals to accomplish this and is flexible enough to satisfy most video documentation requirements. A multiplexer alarm event begins when the unit detects an alarm signal at the alarms connector, or motion at a camera set up for motion alarms. The sequence of events following alarm detection is determined by one or more of the following:

Uncontrolled Alarm Recording

•

Multiplexer option settings.

•

VCR programming.

•

Connections between the multiplexer and the VCR.

When alarm recording is not controlled, the VCR records alarm cameras as normal video. Recorder operation is not affected by alarm events. The VCR simply records alarm video output by the multiplexer at the set time-lapse speed. Uncontrolled alarm recording requires only video connections between the multiplexer and the VCR. Alarm connections at the VCR are not required. To set up the system for uncontrolled alarm recording: •

Connect the multiplexer vcr in and vcr out connectors to the VCR’s video output and video input respectively.

•

Set the multiplexer ALARM DURATION option to the minimum number of seconds you wish each alarm event to be recorded.

•

Set the VCR’s time-lapse speed as desired.

•

Set both the multiplexer VCR RECORD TIME and VCR ALARM RECORD TIME options to match the speed set at the VCR.

Page 56

Appendixes

Controlled Alarm Recording

47

When alarm recording is controlled by the multiplexer, the VCR responds to the alarm signal provided by the multiplexer. The recorder goes into the alarm recording mode and records at the alarm record speed. It remains in the alarm mode until released by the multiplexer. Controlled alarm recording requires both video and alarm connections between the multiplexer and the VCR. System setup for multiplexer controlled alarm recording: 1.

Connect the multiplexer vcr in and vcr out connectors to the VCR’s video output and video input respectively.

2.

Connect the VCR’s ground to the multiplexer alarms connector pin 17 (alarm output common).

3.

Connect the VCR’s alarm input to multiplexer alarms connector pin 19 if VCR alarm input polarity is active low or pin 18 if VCR alarm input polarity is active high.

4.

Set the multiplexer ALARM DURATION option to the minimum number of seconds you wish each alarm event to be recorded.

5.

Set the VCR’s alarm duration option to “manual”.

6.

Set the multiplexer VCR ALARM RECORD TIME option to match the VCR’s alarm recording speed. If using the Autodetect VCR Speed feature (pin 37 on alarms connector), the connections between the multiplexer and VCR permit each unit to change recording speed as needed. See Alarm Output and Autodetect VCR Speed for details.

7.

Set the multiplexer VCR RECORD TIME option to match the VCR’s normal recording speed.

Page 57

48

Video Multiplexer with Video Motion Detection

APPENDIX C IN CASE OF TROUBLE

If you experience difficulties during the installation or operation of the multiplexer, review the section of this manual which explains the related feature or task. If necessary, consult the troubleshooting table on the following pages. If the problem cannot be resolved, you may have to contact Technical Support. When you call, the representative will ask you to provide specific information about the installation. To save time, spend a few minutes getting organized before you pick up the telephone. Before calling, have the following information ready: •

The serial number of your multiplexer.

•

The make and model of each piece of hardware connected to the multiplexer.

•

Approximate date of purchase and of installation.

•

A specific description of the problem.

NOTE: Please do NOT return any product to the Factory without first obtaining a Return Authorization (RA) number. Failure to do so can result in a significant delay in processing your repair. Contact Technical Support to obtain an authorization number.

Page 58

Appendixes

49

TROUBLESHOOTING GUIDE PROBLEM

POSSIBLE CAUSES

SUGGESTED ACTION

Video Problems in Live Mode Live pictures too bright, too dark, bad color or gray tones.

Monitor not correctly adjusted.

Adjust monitor using gray or color bars, as applicable.

Termination not set correctly.

Check termination switches on back panel for each camera output.

Some live pictures too dark.

Camera iris is not correctly adjusted.

Adjust camera iris using calibrated monitor.

Some live pictures too light.

Some cameras are not terminated.

Check rear panel switches for each camera, set for 75-ohms.

Camera iris is not correctly adjusted.

Adjust camera iris using calibrated monitor.

Black horizontal lines in picture, picture unstable.

Faulty camera sync or video output.

Replace affected camera with a known good camera.

One or more camera images do not change.

VIDEO LOSS ALARM set to OFF, or VIDLOSS message cleared before video loss is fixed.

Change display format, if camera window is blank, check video connections and camera.

Video Problems in Tape Mode Poor pictures, bad color, image unstable.

VCR faulty or requires maintenance.

Perform periodic maintenance and test VCR performance.

RECORDER STOPPED message on monitor.

Operator changing operating mode of unit.

For tape playback, press play on the VCR.

Motion Detection Problems No alarm when motion is detected at some or all cameras.

Camera ALRM option set OFF, no motion detection for those cameras.

Set ALRM option to ON for each camera needing motion detection.

ALARM MESSAGE DISPLAY set to AND , both contact alarm and motion needed for alarm.

Check contact alarm device and connection to alarm input pin. Use TST to check motion settings.

Table 2, Troubleshooting Guide

Page 59

50

Video Multiplexer with Video Motion Detection

TROUBLESHOOTING GUIDE PROBLEM

POSSIBLE CAUSES

SUGGESTED ACTION

Motion Detection Problems Important motion not detected.

Motion targets turned off, SENSE (sensitivity) too low or DELAY too long.

Turn on motion targets where needed, check SENSE and DELAY settings.

Unimportant motion detected.

Unnecessary motion targets turned on, SENSE too high or DELAY too short.

Turn off unneeded motion targets, check SENSE and DELAY settings.

Motion detected when no motion occurred.

Camera is random interlace type, video is not stable or camera mounting is loose.

Replace camera or substitute another model to test. Check camera mounting.

Alarm Detection Problems No alarm message.

ALARM MESSAGE DISPLAY set OFF. Set ALARM MESSAGE DISPLAY ON.

No alarm tone heard.

AUDIBLE ALARM set OFF.

Set AUDIBLE ALARM ON.

No response to a contact alarm input or continuous alarm when alarm input is connected.

Alarm not connected properly.

Check connections and correctly connect alarm.

Alarm device polarity and multiplexer alarm input polarity do not match.

Change alarm device polarity or multiplexer alarm input polarity.

Remote Control Problems No response to remote Remote panel data cable plugged control panel. Remote into remote out connector. control panel LEDs off, remote panel Remote panel data cable loose. beeping.

Plug remote panel data cable into remote in connector. Reconnect remote panel cable.

No response to remote Remote panel power cable loose or control panel. Remote not connected. control panel LEDs off.

Check remote panel power cable connection.

No response to remote Serial communications protocol not input. correct.

Configure remote device for 1200 bps, 1 start bit, 8 data bits, 1 stop bit, no parity.

Page 60

Appendixes

51

APPENDIX D TECHNICAL SPECIFICATIONS Operating Defaults

Video Format

The following specifications apply to Sensormatic multiplexer series products only. Sensormatic reserves the right to revise and improve its products. All specifications are therefore subject to change without notice. Format

Displays all cameras

Display

Live

Switcher

Sequence off

VCR Record Time

24 hours

VCR Alarm Record Time

02 hours

Alarm Duration

4 seconds

Alarm Message Display

On

Global Dwell

2 seconds

Alarm Message Latch

Off

Video Loss Alarm

On

Audible Alarm

Off

Alarm Input Polarity

Active low

Alarm Output Polarity

Active high

Pass-Thru Extrnl Alrms

Yes

Image Tenderizer

On

Camera Titles

Camera number

Motion Setup Screen

All targets selected

Motion Alarm (ALRM)

Off

Sensitivity (SENSE)

Medium (MED)

Object Size (SIZE)

1 Wide by 1 High (1Wx1H)

Alarm Delay (DELAY)

Off

Security Lock

Off

NTSC/EIA or PAL/CCIR