Page 10

System Printer Driver Run-time Diagnostic Logging Driver debug logging should only be used to capture the state of the driver when a failure is expected. The log file will grow even when the printer is idle, and there is no limit to the size. This will also have a slight impact on system performance. You must have administrator privileges to perform the following commands. (On Vista, you will need to right-click on the Command Prompt icon, and select "Run as administrator" when opening the prompt to restart the spooler. You will also need to run the .reg files as administrator, which means you either should run regedit as admin and import the .reg file, or run the .reg files from an elevated command prompt.) The .reg files may be found at C:\Program Files\Seiko Instruments Inc\Smart Label Printer <current version>\Admin\. Turn driver debugging on

Run SLPDriverDebugOn.reg - either double click, or on Vista, type the name of the file (with path if necessary) in an elevated command prompt. Agree to the prompts about changing the registry. Open a command prompt (or use the current elevated prompt if Vista). Execute the following 2 lines in the command prompt: net stop spooler net start spooler The debug file will be written to C:\slp<version_number>.log. Turn driver debugging off

Run SLPDriverDebugOff.reg - either double click, or on Vista, type the name of the file (with path if necessary) in an elevated command prompt. Agree to the prompts about changing the registry. Open a command prompt (or use the current elevated prompt if Vista). Execute the following 2 lines in the command prompt: net stop spooler net start spooler

Page 10

Page 11

System Printer Driver Polling On or Off Idiosyncrasies found in some installations of Windows may preclude these systems from printing via the System Printer Driver after waking from Hibernate. Turning off the System Printer Driver’s ability to poll for printer status solves this issue. (Printer status can be found in the printer’s queue.) The reg files below will enable or disable polling in the System Printer Driver. The .reg files may be found at C:\Program Files\Seiko Instruments Inc\Smart Label Printer <current version>\Admin\. Turn driver polling on

Run SLPDriverIdlePollingOn.reg- either double click, or on Vista, type the name of the file (with path if necessary) in an elevated command prompt. Agree to the prompts about changing the registry. Open a command prompt (or use the current elevated prompt if Vista). Execute the following 2 lines in the command prompt: net stop spooler net start spooler Turn driver polling off

Run SLPDriverIdlePollingOff.reg- either double click, or on Vista, type the name of the file (with path if necessary) in an elevated command prompt. Agree to the prompts about changing the registry. Open a command prompt (or use the current elevated prompt if Vista). Execute the following 2 lines in the command prompt: net stop spooler net start spooler

Page 11

Page 12

Changing Printer’s Serial Baud Rate Settings Some embedded systems have serial ports with slow baud rates. And sometimes these baud rates are incompatible with the default baud rates of the Smart Label Printers. The 440 and 450 printers have an EEPROM that can store the default baud rate that the printer should use when it powers up. Within the standard application install is a program called “SlpSelect.exe”. Executing SlpSelect.exe as described below will present a private interface for changing the baud rate of attached printers. 1. Attach an SLP 440, 450, or 650SE to the serial port of your computer. (The USB cable should not be attached.) If your printer did not come with a serial cable please contact support. You may qualify for a free serial cable from Seiko Instruments Inc. 2. Power on the printer. 3. Execute SlpSelect.exe /default [port] [baudrate] a. port is one of COM1, COM2, COM3 or COM4 b. baudrate is 9600, 19200, 38400, 57600, 115200 For example: > SlpSelect.exe /default COM1 9600 4. Follow the instructions on-screen.

Factory baud rate for the SLP 440 is 115,200. Factory baud rate for early SLP 450 models is 38,400 and 115,200 for later models. To test the baud rate change with the system level printer driver, use the Page 12

Page 13

following settings for serial printing (substituting baud rate) and then print a small page with Notepad.exe.

Page 13

Page 14

Launching SmartLabel in another language When the SmartLabel application launches, the language the user interface appears in is determined by the language preference of your operating system. The choice of language can be overridden. Launch SLP with a specific language by using the /Lang=xxx command line switch, where xxx is one of the following: CNY DEU ENU ESP FRA ITA JPN NLD PTB RUS

(Simplified Chinese) (German) (US English) (Spanish) (French) (Italian) (Japanese) (Dutch) (Brazilian Portuguese) (Russian)

Note that, when using this language override switch, text provided directly from Windows will still appear in the current system language. This includes: Text in most common dialogs (e.g., File Open) Buttons in message boxes (e.g., OK, Cancel, Yes, No, etc.) System error text in some error message boxes (e.g., "Access denied.") Tip: Make a shortcut to the slpwin.exe and add the /LANG=xxx to the end of the target field in the shortcut properties. Silent Installation The SmartLabel Printer Driver can be installed with our installer silently, without a user interface. To do this, utter the following command on the command-line: setupSlpInstaller.exe /s /v"/qn ADDLOCAL=Driver" “Driver” may be replaced by any feature name. Feature names include: • • •

Application Driver All (default)

Page 14

Page 15

2D Barcodes Below are the details for the Advanced "Mode" and "Security" settings for 2D barcode formats supported by Smart Label. Maxicode Maxicode Mode Settings: 4 - Any data up to 84 data characters automatically split between primary and secondary messages. 5 - Any data up to 68 data characters automatically split between primary and secondary messages. Enhanced error correction used. Maxicode Security Settings: N/A PDF417 PDF417 Mode Settings: 0 - EXC Alpha 1 - EXC Lower 2 - EXC Mixed 3 - EXC Punctuation. 4 - Binary/ASCII Plus 5 - Numeric mode - For most applications, the Mode parameter should be set to 0. - EXC (Extended Alphanumeric Compaction mode) - allows encoding of all printable ASCII characters into about 2 characters per codeword. Within the EXC mode there are several submodes: - EXC Alpha - starts in upper case - EXC Lower - starts in lower case - EXC Mixed - numeric and other punctuation - EXC Punctuation - punctuation & bracket characters. - Binary/ASCII Plus mode - allows encoding of 256 international characters including the full ASCII set plus any 8-bit value in the range 0 - 255. This mode allows encoding approximately 1.2 bytes per codeword and so is considerable less efficient than EXC mode. - Numeric mode - allows encoding of a string of digits with a density of approximately 2.95 digits per codeword. Recommended where more than 13 digits are to be encoded. Numeric mode symbols may not contain non-numeric characters. - The maximum capacity of PDF417 symbols is approximately as follows: - Numeric mode - maximum capacity 2700 digits* Page 15

Page 16

- Alphanumeric text - maximum capacity 1800 characters* - Byte values - maximum capacity 1100 bytes * Note that capital letters, punctuation, mode shifts and new lines/paragraphs reduce these value. PDF417 Security Settings: 0-0 1-2 2-6 3 - 14 4 - 30 5 - 62 6 - 126 7 - 154 8 - 510 One of PDF417's most valuable features is its ability to allow correction of errors. This ability is provided by the inclusion of additional codewords within the symbol, so that the data codewords may be reconstructed even if some are defaced or misread. The number of damaged codewords (Nmax) which may be recovered depends on the security level (which in turn determines the number of additional characters included in the symbol). Datamatrix Datamatrix Mode Settings: 0 - Square 1 - Rectangular DataMatrix is a two dimensional matrix symbology which is made up of square modules arranged within a finder pattern. DataMatrix symbols may be square or rectangular. Datamatrix Security Settings: DataMatrix symbols can include a user-selected amount of error-correction data. For Square symbols the Security Level setting may be in the range 0 - 24, while for Rectangular symbols the allowed range is 0 - 6. Notes: DataMatrix symbols can encode the entire ASCII character set and uses multiple encoding modes which are, in order of efficiency: Double digits - maximum capacity 3100 digits Alphanumeric text - maximum capacity 2300 characters* Page 16

Page 17

Byte values - maximum capacity 1550 bytes *Note that capital letters, punctuation and new lines/paragraphs reduce this value. dLSoft 2D barcode products support only ECC200 symbols - the older ECC140 and below are not supported. Also at this time ECI and Appended symbols are not supported. If the first data character is FNC1 (ASCII 232) the remaining data is treated as EAN/UCC data; i.e. brackets are removed from the data. Any AIs included in the data that are NOT fixed length should be terminated with a FNC1 character. (The FNC1 character may be entered from the keyboard by holding down the <Alt> key and typing 0232 on the numeric keypad.) The industry standard Macro sequences [)><RS>05<GS> and [)><RS>06<GS> are supported (where <RS> represents ASCII 30 and <GS> is ASCII 29). The following character translations are made for data following the [)> start sequence: String Converted to <ET> ASCII 4 <FS> ASCII 28 <GS> ASCII 29 <RS> ASCII 30 <US> ASCII 31

Page 17