Unit 4: Replacement Procedures

REPLACEMENT PROCEDURES • • • • • • • • • • •

SATO D508/D512 Service Manual

Print Head Platen Roller Fuse Main Circuit Board Panel Board Label Sensor Board Label Sensor Cover Open Sensor Drive Motor Drive Gear Cutter Replacement

Page 4-1

Page 62

REPLACEMENT PROCEDURES This unit contains step-by-step instructions for the removal and replacement of all primary components and sub-assemblies.

PRINT HEAD REPLACEMENT If the print head becomes damaged or worn, it can be easily removed and replaced without having to make critical adjustments. 1 Turn the printer OFF and disconnect the power supply cord. 2

Lift up the top housing cover (1) (See Figure 4-1) to access the print head assembly.

3

Press the central release latch (2) to release the print head (3) from the bracket (4). NOTE: To detach the print head, press the release latch (2), then simultaneously tilt the print head downwards.Tilt it at an angle and pull it out.

4

Disconnect the wiring harness from worn print head (3).

5

Connect the print head wiring harness to the replacement print head (3).

6

Latch the replacement print head (3) into the head bracket (2). NOTE: Insert the lower portion of the print head first, sliding it into the pivot pins at each end of the bracket. Press inward and raise upward, the upper portion of the print head until it locks into position.

7

Load some media, close the cover, and do a test print to confirm proper function. 2 1

4

3

Figure 4-1, Print Head Replacement

Page 4-2

SATO D508/D512 Service Manual

Page 63

Unit 4: Replacement Procedures

PLATEN ROLLER REPLACEMENT The platen roller is a high wear component due to its treading against the print media. This treading will eventually wear grooves into the rubber material and negatively affect print output. 1

Turn the printer OFF and disconnect the power supply cord.

2

Lift up the top housing cover (1) (See Figure 4-2) to access the platen roller (2).

3

Detach the platen gear cover (3) from the printer housing (4).

4

Lift the dispenser bar (5) upward and away from the assembly (2, 5).

5

Install a replacement platen roller assembly (5, 2) to the housing (4).

6

Lower the dispenser bar (5) and reattach the gear cover (3).

7

Load some media, close the cover, and do a test print to ensure proper function.

1 3 2

5

4

Figure 4-2, Platen Roller Replacement

ACCESSING THE MAIN BOARD

SATO D508/D512 Service Manual

Page 4-3

Page 64

Throughout the rest of this Service Manual, reference will be made to the main board of the printer. To access the main board, follow the instructions below. 1

Turn the printer OFF and disconnect the power supply cord.

2

Place the printer with its underside facing upward.

3

Remove the bottom housing cover (See Figure below) by removing four screws.

4

Put the screws in a safe place so that they can be used to re-secure the bottom housing cover when servicing is complete.

Screw x4

Figure 4-3, Removing Bottom Cover

Page 4-4

SATO D508/D512 Service Manual

Page 65

Unit 4: Replacement Procedures

FUSE REPLACEMENT 1

Turn the printer OFF and disconnect the power supply cord.

2

Remove the base cover from the housing cover to access the fuse.

3

Locate fuse (1), (See Figure 4-4) on the main circuit board (2).

4

Detach the defective fuse (1) from the metal holders (3).

5

Attach a replacement fuse (1) to the metal holders (3) on the main circuit board (2).

6

Attach base cover to the housing cover.

7

Load some media, and run some tests to confirm proper function. 1

2

3

Figure 4-4, Fuse Replacement

SATO D508/D512 Service Manual

Page 4-5

Page 66

MAIN CIRCUIT BOARD REPLACEMENT 1

Turn the printer OFF and disconnect the power supply cord.

2

Remove the base cover from the housing cover to access the main circuit board.

3

Remove the five screws (1) (See Figure 4-5) that secure the main circuit board (2) to the printer (3).

4

Disconnect all wiring harnesses from the defective main circuit board (2).

5

Remove the defective main circuit board (2), along with the interface cover (4), from the printer (3).

6

Detach the interface cover (4) from the defective board (2) and attach it to the replacement board (2).

7

Insert the replacement main circuit board (2) into the printer (3) and secure it using the five screws (1) previously removed from the old board.

8

Reconnect all the appropriate wiring harnesses to the replacement circuit board (2). NOTE: Each wiring harness connector is different from the others. To reconnect the wiring harnesses, simply match mating halves.

9

Attach the base cover to the housing cover.

10

Load some media, and run some tests to confirm proper function.

4 2 1

3

Figure 4-5, Main Circuit Board Replacement

Page 4-6

SATO D508/D512 Service Manual

Page 67

Unit 4: Replacement Procedures

PANEL BOARD REPLACEMENT 1

Turn the printer OFF and disconnect the power supply cord.

2

Remove the base cover from the housing cover to access the panel board.

3

Remove the two screws (1) (See Figure 4-6) that secure the panel board bracket (2) to the printer (3).

4

Disconnect the wiring harness for the defective panel board (4) from the main circuit board (5).

5

Detach the lens unit (6), button unit (7), and panel board (4), from the bracket, in this order (2).

6

Insert the wiring harness of the replacement panel board (4) through bracket (2) and connect to main circuit board (5).

7

Reattach the replacement panel board (4), button unit (7), and lens unit (6) consecutively to bracket (2).

8

Insert the assembly (7, 6, 4, 2) into the printer (3) and secure using two screws (1). NOTE: When properly installed, the lens, buttons, and power switch should protrude through their respective slots on the printer’s front panel.

9

Attach the base cover to the housing cover.

10

Load some media, and run some tests to confirm proper function.

2

1

4 7 6

5 3

Figure 4-6, Panel Board Replacement

SATO D508/D512 Service Manual

Page 4-7

Page 68

RELAY BOARD (LABEL SENSOR BOARD) REPLACEMENT 1

Turn off the printer and disconnect the power supply cord.

2

Remove all media from the printer.

3

Remove one screw (1) (See Figure 4-7a) that secures the bar (2) to the printer (3).

4

Remove one screw (4) and gear (5) from the printer (3).

5

Lift away the left-side media holder (6) from the printer (3). 4 5 6 1 2

3

Figure 4-7a, Label Sensor Board Replacement 6

Remove the three screws (7) (See Figure 4-7b) securing the cover (8) to the left-side media holder (6).

7

As the main signal cable of the relay board (9) is soldered on, you need to disconnect the other end of the cable from the main board by the following steps. NOTE: Each wiring harness connector is different from the others. To reconnect the wiring harnesses, simply match mating halves.

Page 4-8

SATO D508/D512 Service Manual

Page 69

Unit 4: Replacement Procedures

6

9

8

7

Figure 4-7b, Relay Board Replacement 8

Remove the base cover from the housing cover to access the main board (10) (Figure 4-7c).

9

Remove the five screws (11) securing the main circuit board (10) to the printer (3).

10 11

3

Figure 4-7c, Detachment of Relay Board signal cable from Main Board 10

Lift the main board (10) and disconnect the wiring harness of the relay board.

11

Now replace the relay board and reconnect the main signal wire to the main board.

12

Reinstall the main board and the cover.

13

Re-attach the base cover (8) to the left-side media holder (6) using three screws (7).

14

Place the left-side media holder (6) (See Figure 4-7a) into the printer (3) along with the gear (5) and secure using a screw (4).

15

Secure the bar (2) to the printer (3) using a screw (1).

16

Load some media, and run some tests to confirm proper function.

SATO D508/D512 Service Manual

Page 4-9

Page 70

LABEL SENSOR REPLACEMENT 1

Turn the printer OFF and disconnect the power supply cord.

2

Remove all media from the printer.

3

Remove one screw (1) (See Figure 4-8a) that secures the bar (2) to the printer (3).

4

Remove one screw (4) and gear (5) from the printer (3).

5

Lift away the left-side media holder (6) from the printer (3).

6

Remove one screw (7) that secures the sensor cover (8) to the left-side media holder (6).

7

Remove one screw (9) that secures the sensor (10) to the sensor cover (8). 4 5 6 1 2 8 10 9

7

3

Figure 4-8a, Label Sensor Replacement

Page 4-10

SATO D508/D512 Service Manual