Page 25
Unit 2: Interface Specifications
BASIC AND INTERFACE SPECIFICATIONS • •
D508/D512 Service Manual
Basic Printer Specs Interface Specs
Page 2-1
Page 26
1.1 BASIC PRINTER SPECIFICATIONS Attribute PRINT Print Method CPU Printer Command Language Resident Fonts
Font Memory Print Head Resolution Print Speed Max. Print Area MEDIA Label Thickness (Label + backing paper) Label Form
Label Size (adhesive labels)
Direct Thermal 32-bit RISC processor SBPL U S M XU XS SM WB WL XB XL CG Times CG Triumvirate OCR-A OCR-B 4 MB 8 dots per mm for 203 dpi | 12 dots per mm for 305 dpi 6 ips 104 mm (width) by 400 mm (pitch)
0.06 mm* ~ 0.19 mm (*Check with your dealer regarding conditions for using thin 0.06 mm labels) Roll Label : Maximum outer diameter of 110mm (face out), Core Inner Diameter of 40mm Fan-fold label : Max foldable height 100 mm (loaded externally) For continuous feed: Width: 25~115 mm (including liner 28~118 mm) Pitch: 15~397mm (including liner 18~400 mm) For Cutter usage (optional): Width: 25~115 mm (including liner 28~118 mm) Pitch: 20~397mm (including liner 23~400 mm) For Tear Off mode: Width: 25~115 mm (including liner 28~118 mm) Pitch: 15~397mm (including liner 18~400 mm)
Label Size (non-adhesive labels)
For continuous feed or tear off mode: Width: 25~118mm Pitch: 15~400 mm With cutter installed: Width: 25~118mm Pitch: 20~400 mm
SENSING See-Through for labels or tags Continuous Form Eye Mark
0.012” (3 mm) Sensor not used Fixed, 0.25" (6.3 mm) from left label edge. 0.12” (3 mm) wide x minimum 0.5” (12 mm) in length from left label edge.
*All specifications subject to change without notice.
Page 2-2
D508/D512 Service Manual
Page 27
Unit 2: Interface Specifications
1.1 GENERAL SPECIFICATIONS (CONT’D) Attributes CONTROLS AND SIGNALS On-Line LED Power LED Error LED LED Display Panel On/Off-Line Button Label Feed Button Power On/Off Button Self Diagnostics
POTENTIOMETER ADJUSTMENTS Adjustment Potentiometers
DIP switches
INTERFACE CONNECTIONS Parallel (Option) Serial (Option)
USB (Option) LAN (Option) RFID (Option) Wireless LAN (Option)
Green Green Red 7-Segment Single Character Front Panel Front Panel Front Panel Head check Paper end Cover open Test print VR1: Offset level (DIPSW6 = OFF) VR1: Print darkness (DIPSW6 = ON) VR2: Eye Mark / Paper End (to adjust the threshold) VR3: Gap sensor (to adjust the threshold) VR4: Label pitch offset DIP-SW -1,2,3 : Operation mode(Print mode/Download mode) DIP-SW -4 : Reserved (constantly OFF) DIP-SW -5 : Head check (ON-Enabled / OFF-Disabled) DIP-SW -6 : VR1 function switch (ON-Print darkness level / OFF-Offset) DIP-SW -7 : DATA dump (ON-HEX dump print / OFF-Normal print) DIP-SW -8 : Reserved (constantly OFF)
IEEE1284 RS232C (9600 to 57.6K bps) Hardware Flow Control (Ready/Busy) Software Flow Control (X-On/X-Off) Bi-directional Status USB Specification Version 1.1 10/100 Base-T 13.56 MHz band, TBA TBA
*All specifications subject to change without notice.
D508/D512 Service Manual
Page 2-3
Page 28
1.1 GENERAL SPECIFICATIONS (CONT’D Barcodes SYMBOLOGIES Supported 1D formats (excluding customized barcode addressing in firmware)
Supported 2D formats
Ratios Bar Height Rotation
UPC-A/E EAN-8/EAN-13 CODABAR CODE39 CODE93 CODE128 UCC/EAN128 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2of5 RSS Composite MSI POSTNET Bookland PDF 417 Micro PDF 417 Truncated PDF 417 Maxicode Data Matrix QR Code 1:2, 1:3, 2:5 User definable bar widths (depending on software) 4 to 600 dots (depending on software) 0°, 90°, 180° and 270° (depending on software)
*All specifications subject to change without notice.
Physical Attributes DIMENSIONS Width Depth Height Weight POWER REQUIREMENTS Voltage
Power Consumption ENVIRONMENTAL Operating Temperature
REGULATORY APPROVALS Safety
EMC/EMS
Page 2-4
7.8 in. (198 mm) 9.1 in. (230 mm) 6.6 in. (167 mm) 5.5 lbs (2.5 Kg) excluding AC adaptor
USA: AC 115 V (+/- 10 %) Europe: AC 230V (+/- 10 %) 50/60 Hz (+/-1%) 67W nominal
Operation environment 0~35°/30~80% (without condensation) Storage environment -5~45°/20~80% (without condensation)
USA : UL(UL60950-1) CANADA : C-UL(CSA C22.2 No.60950-1-3) Europe : TUV(EN60950-1), CE USA : FCC15B (ClassB) Europe : EN55022 ClassB, EN61000-3-2, EN610003-3,EN55024
D508/D512 Service Manual
Page 29
Unit 2: Interface Specifications
1.1 GENERAL SPECIFICATIONS (CONT’D Optional Accessories Internal Cutter IEEE1284 Interface Serial Interface LAN Interface USB Interface RFID Wireless LAN Interface
User or factory installed Internal option allowing labels to be cut at specified intervals. Parallel interface. Factory or User installable High Speed RS232 Interface option, 9600 bps to 57.6 Kbps. Factory or User installable. TCP/IP Protocol Interface option. Factory or User installable. Universal Serial Bus Interface option. Factory or User installable. To be announced 802.11 b/g
*All specifications subject to change without notice.
D508/D512 Service Manual
Page 2-5
Page 30
INTERFACE SPECIFICATIONS INTERFACE TYPES The SATO D508/D512 printer can be ordered with any of the interfaces described in this section. The user can specify the desired interface at the time of placing an order. Thereafter, if the user needs to change the interface, it is a simple matter of purchasing a suitable interface card from a SATO dealer. The following are the different types of interface boards available: 1) RS232C Interface Board 2) IEEE1284 Parallel Interface Board 4) USB Interface Board 5) LAN Interface Board (standard 10Base-T/100Base-T interface with RJ-45 connector) 6) Wireless LAN (802.11 b/g) For programmers and technical personnel to fully utilize the printer, the following information is presented in this section: • The Receive Buffer • IEEE1284 Parallel Interface • Universal Serial Bus (USB) Interface • Local Area Network (LAN) Interface • RS232C Serial Interface General Specifications Electrical Specifications Pin Assignments Ready/Busy Flow Control X-On/X-Off Flow Control
Page 2-6
D508/D512 Service Manual
Page 31
Unit 2: Interface Specifications
THE RECEIVE BUFFER This printer has the ability to receive a data stream from the host in one of two ways. The receive buffer may be configured to accept one print job at a time or multiple print jobs. The single job print buffer is generally used by software programs that wish to maintain control of the job print queue so that it can move a high priority job in front of ones of lesser importance. The multiple job buffer, on the other hand prints all jobs in the order they are received by the printer, and the order of printing cannot be changed.
Single Job Buffer The printer receives and prints one job at a time. Each job must not exceed 2.95MB.
D508/D512 Service Manual
Page 2-7
Page 32
THE RECEIVE BUFFER (CONT’D) Multi Job Buffer The printer is able to continuously receive print jobs, compiling and printing other jobs at the same time. It acts much like a "print buffer" to maximize the performance of the host and the printer. When you are using the RS232 Serial interface, the Multi Job Buffer uses either the Ready/Busy with DTR (pin 20) or X-On/X-Off flow control protocols. With an empty receiving buffer, the status of DTR is "high" (or an X-On status if using X-On/X-Off), meaning the printer is ready to receive data. When the receive buffer is holding 1.95MB of data (1MB from being full), DTR will go "low" (or an X-Off is sent) indicating the printer can no longer receive data. This condition is called "Buffer Near Full." The receiving buffer will not be able to receive more data again until a "Buffer Available" condition occurs. This takes place when the receiving buffer has emptied so that only 1MB bytes of data are being held (1.95MB bytes from being full). At this time, DTR will go "high" or an X-On is sent to tell the host that it can again receive data. All printer error conditions (i.e., label out, Time-out Error, etc) will cause the printer to go busy (DTR "low" or X-Off) until the problem is corrected and the printer is placed on-line. The printer will also be busy if taken off-line from the front panel.
Page 2-8
D508/D512 Service Manual
Page 33
Unit 2: Interface Specifications
IEEE1284 PARALLEL INTERFACE The parallel interface for this printer conforms to the IEEE1284 specification. It will automatically detect the IEEE1284 signals and operate in the high speed mode. If it does not detect the IEEE1284 signals, it will operate in the standard Centronics mode, which is significantly slower. For this reason, an interface cable and host interface conforming to the IEEE1284 specification must be present to fully utilize the speed capabilities. This interface also operates bidirectionally and can report the status of the printer back to the host.
Electrical Specifications Printer Connector Cable Connector Cable Length Signal Level
PIN
SIGNAL
1
STROBE
2
DATA 1
3
DATA 2
4
AMP 57-40360 (DDK) or equivalent AMP 57-30360 (DDK) or equivalent 10 ft. (3 m) or less High = +2.4V to +5.0V Low = 0V to -0.4V
DIRECTION
PIN
SIGNAL
DIRECTION
To Printer
19
STROBE Return
Reference
To Printer
20
DATA 1 Return
Reference
To Printer
21
DATA 2 Return
Reference
DATA 3
To Printer
22
DATA 3 Return
Reference
5
DATA 4
To Printer
23
DATA 4 Return
Reference
6
DATA 5
To Printer
24
DATA 5 Return
Reference
7
DATA 6
To Printer
25
DATA 6 Return
Reference
8
DATA 7
To Printer
26
DATA 7 Return
Reference
9
DATA 8
To Printer
27
DATA 8 Return
Reference
10
ACK
To Host
28
ACK Return
Reference
11
BUSY
To Host
29
BUSY Return
Reference
12
PTR ERROR
To Host
30
PE Return
Reference
13
SELECT
To Host
31
INIT
From Host
14
AUTOFD (1)
To Host
32
FAULT
To Host
15
Not Used
33
Not Used
16
Logic Gnd
34
Not Used
17
FG
Frame Ground
35
Not Used
18
+5V(Z=24Kohm)
To Host
36
SELECTIN (1)
From Host
(1) Signals required for IEEE1284 mode
D508/D512 Service Manual
Page 2-9
Page 34
RS-232C INTERFACE The High Speed Serial Interface is an factory installed option that must be installed in the printer at the time of order. The D500 recognizes the RS-232 interface automatically. General Specifications Asynchronous ASCII
Half-duplex communication Ready/Busy Hardware Flow Control Pin 20, DTR Control Pin 4, RTS Error Condition X-On/X-Off Software Flow Control Bi-Directional Communication
Data Transmission Rate
9600, 19200, 38400, 57600 bps
Character Format
1 Start Bit (fixed) 7 or 8 data bits (selectable) Odd, Even or No Parity (selectable) 1 or 2 Stop bits (selectable)
Electrical Specifications Connector
DB-25S (Female)
Cable
DB-25P (Male), 50 ft. maximum length. For cable configuration, refer to Cable Requirements appropriate to the RS232C protocol chosen.
Signal Levels
High = +5V to +12V Low = -5V to -12V
Page 2-10
D508/D512 Service Manual
Page 35
Unit 2: Interface Specifications
Pin Assignments Pin 13
Pin 1
Pin 25
Pin 14
RS-232C INTERFACE SIGNALS Pin
Direction
Signal Definition
1
Reference
FG (Frame Ground)
2
To Host
TD (Transmit Data) -Data from the printer to the host computer. Sends X-On/X-Off characters or status data (Bi-Directional protocols).
3
To Printer
RD (Receive Data) -Data to the printer from the host computer.
4
To Host
RTS (Request to Send) -Used with Ready/Busy flow control to indicate an error condition. RTS is high and remains high unless the print head is open (in this case, RTS would return to the high state after the print head is closed and the printer is placed back on-line) or an error condition occurs during printing (e.g. Time Out error, label out).
5
To Printer
CTS (Clear to Send) -When this line is high, the printer assumes that data is ready to be transmitted. The printer will not receive data when this line is low. If this line is not being used, it should be tied high (to pin 4).
6
To Printer
DSR (Data Set Ready) -When this line is high, the printer will be ready to receive data. This line must be high before data is transmitted. If this line is not being used, it should be tied high (to pin 20).
7
Reference
SG (Signal Ground)
20
To Host
DTR (Data Terminal Ready) -This signal applies to Ready/Busy flow control. The printer is ready to receive data when this pin is high. It goes low when the printer is off-line, either manually or due to an error condition, and while printing in the Single Job Buffer mode. It will also go low when the data in the buffer reaches the Buffer Near Full level.
Cable Requirements
D508/D512 Service Manual
Page 2-11
Page 36
DB9
DB2 5
HOST
INTERCONNECTION
PRINTER
1
1
FG
1
FG (Frame Ground)
2
3
RD
2
TD (Transmit Data)
3
2
TD
3
RD (Receive Data)
8
5
CTS
4
RTS (Request to Send)
7
4
RTS
5
CTS (Clear to Send)
4
20
DTR
6
DSR (Data Set Ready)
6
6
DSR*
20 DTR (Data Terminal Ready)
5
7
SG
7
SG (Signal Ground)
* This connection at the host side of the interface would depend upon the pin that is being used as the Ready/Busy signal by the driving software. Typically, on a PC, it would be either CTS (pin 5) or DSR (pin 6) on a DB-25 connector.
READY/BUSY FLOW CONTROL Ready/Busy is the hardware flow control method for the serial interface on the printer. By raising/ lowering the voltage level on Pin 20 of the RS232 port, the printer notifies the host when it is ready to receive data. Pin 4 (RTS) and pin 20 (DTR) are the important signals on the printer for this method of flow control. The host must be capable of supporting this flow control method for it to function properly.
X-ON/X-OFF FLOW CONTROL X-On/X-Off flow control is used whenever hardware (Ready/Busy) flow control is not available or desirable. Instead of a voltage going high/low at pin 20, control characters representing "Printer Ready" (X-On =11 hexadecimal) or "Printer Busy" (X-Off = 13 hexadecimal) are transmitted by the printer on pin 2 (Transmit Data) to the host. In order for this method of flow control to function correctly, the host must be capable of supporting it. X-On/X-Off operates in a manner similar to the function of pin 20 (DTR) as previously explained. When the printer is first powered on it sends an X-Off when the "Buffer Near Full" level is reached and a X-On when the data level of the buffer drops below the "Buffer Available" mark. When the printer is taken off-line manually, it transmits an X-Off indicating it cannot accept data. When it is placed back on line manually, it sends an X-On, indicating it is again available for receipt of data. If an error occurs during printing (paper out, Time Out), the printer sends an X-Off as soon as an error condition is detected. When the error is cleared and the printer is placed back on-line, it transmits an X-On indicating it is again ready to accept data. Upon power up if no error conditions are present, the printer will continually send X-On characters at five millisecond intervals until it receives a transmission from the host.
UNIVERSAL SERIAL BUS INTERFACE
Page 2-12
D508/D512 Service Manual
Page 37
Unit 2: Interface Specifications
The Universal Serial Bus (USB) interface is a factory installed option that must be specified at the time of order. It requires a driver (shipped with each printer that has the interface installed) that must be loaded on your PC and the PC must be configured to support USB peripherals using Microsoft Windows. Details for loading the USB driver are contained in the USB Interface Manual that is shipped with each printer with a USB Optional interface installed. Up to 127 devices may be connected to a USB port.
LOCAL AREA NETWORK INTERFACE A Local Area Network (LAN) interface is a factory installed interface option that must be specified at the time of order. It requires a driver (shipped with each printer that has the interface installed) that must be loaded on your PC and the PC must be configured to support the TCP/IP network protocol using a 10BaseT LAN connection. Details for loading the LAN driver are contained in the LAN Interface Manual that is shipped with each printer with a LAN Optional interface installed.
WIRELESS 802.11 LAN INTERFACE The wireless print server provides easy printer interface with 802.11G Wi-Fi compliant networks free of wired connections. Each printer is shipped with an integrated driver and interface installed. The driver must be loaded onto the host computer and configured to run one of the supported protocols. Details for setting up the Wireless 802.11 LAN Interface are contained in the documentation that is supplied with the interface card.
D508/D512 Service Manual
Page 2-13
Page 38
Unit 2: Interface Specifications
This page is left blank intentionally
D508/D512 Service Manual
Page 2-14