D508/D512 Printer Service Manual: 5. Adjustment Procedures

Pages 81 to 90 of 90, from D508/D512 Printer Service Manual

The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sato D512

Page 81

1CHECKS/ADJUSTMENT PROCEDURES • • • • • • • • • • •

SATO D508/D512 Service Manual

Top of Form Position Factory Clear Print Darkness Printer Counter Clear Cutter Counter Clear Test Print Counter Clear Cut Position Paper Sensor Sensitivity Gap Sensor Sensitivity Eye-Mark Sensor Adjustment Power Supply Checks

Page 5-1

Page 82

Unit 5: Adjustment Procedures

ADJUSTMENT PROCEDURES This unit covers all of the printer adjustment procedures that may occur following the initial configuration.

TOP OF FORMS OFFSET This can be done using the VR4 potentiometer on the Configuration Panel. This potentiometer is set at the factory so that it has a range of +/-3.75 mm. The midpoint setting should have no effect on the label top of form. Turning the potentiometer all the way clockwise should move the print position 3.75 mm upwards towards the leading edge of the label. Turning the it all the way counterclockwise should move the print position down 3.75mm away from the leading edge of the label. Place DSW6 on the Configuration Switch in the OFF position.

2

Turn the power OFF.

3

While pressing the FEED button on the Operator Panel, turn the power ON.

4

When you hear one beep from the printer, release the FEED button.

5

Press the LINE button to begin printing large Test Labels (press the FEED button if you are using labels smaller than 4.1" (104 mm) in width).

6

Adjust potentiometer VR4 until the first print position is at the desired location on the label.

7

Press the FEED button to stop printing.

Must be moved with Minus (-) Offset to print on leading edge of label ABCDEFG ABCDEFG label movement direction

1

Original First Line Print Position

ABCDEFG

Note: Adjusting the Label Top Of Form with VR4 will affect the stop position of the label and the cut/tear-off positions. Moved with Positive (+) Offset to print on trailing edge of label

Page 5-2

Leading Edge of Label as detected by the sensor

SATO D508/D512 Service Manual

Page 83

Unit 5: Adjustment Procedures

FACTORY CLEAR This procedure clears all data from the EEPROM. Once initialized and completed, the process cannot be reversed. 1

Open the Top Cover and remove the front cover.

2

Switch ON the DSW5 and DSW6 dip switches. NOTE: Refer to Figure 5-1 for visual assistance in performing this procedure.

3

Press and hold the LINE and FEED buttons while switching on the printer.

4

Release the LINE and FEED buttons when a beep sounds.

5

Switch OFF the DSW5 and DSW6 dip switches and latch the Top Cover closed. NOTE: When the Top Cover is closed, the clear process will automatically be initialized. During the clear process, the printer will be in an offline state.Press the LINE button to test print a large label and the FEED button to test print a small label.

NOTE: Press the LINE button to test print a large label and the FEED button to test print a small label. Pressing the FEED button terminates printing activity. Print at least two labels to ensure the clear process was successful.

SATO D508/D512 Service Manual

Page 5-3

Page 84

Unit 5: Adjustment Procedures

PRINT DARKNESS A fine adjustment for PRINT DARKNESS can be made using potentiometer VR1 on the Front Operator Panel. It provides a continuous range of adjustment, allowing you to make precise changes. Turning VR1 clockwise will make the print darker, and counterclockwise will make it lighter. 1

Place DSW6 on the Configuration Switch in the ON position.

2

Turn the Power Switch OFF.

3

While pressing the FEED button on the Operator Panel, turn the Power Switch ON.

4

When you hear one beep from the printer, release the FEED button.

5

Press the LINE button to begin printing large Test Labels (press the FEED button if you are using labels smaller than 4.1" (104 mm) in width).

6

Adjust potentiometer VR1 until the desired print darkness is obtained.

7

Press the FEED button to stop the printing.

Adjustment of the Print Darkness using VR1 will affect the darkness in all the <ESC>#E command code ranges; that is, if the print darkness is adjusted with VR1 for lighter print, the darkness will be lighter in all the Print Darkness ranges selected by the command code.

Figure 5-1, Test Panel

Page 5-4

SATO D508/D512 Service Manual

Page 85

Unit 5: Adjustment Procedures

Label Pitch Offset

Eye Offset or Darkness

Gap

VR4

VR1

VR3

Identification

VR2

Printer Test Panel

Dip Switch Complex

8 Test Connector

Potentiometers

1A 2A 3A

Set the dial to the correct pin number

8

0

4A

1

5A

7

2

Test Module Dial

1B

6

3 5

4

2B 3B 4B

Connect ground probe here Connect positive probe here

6A

GND

SIG

5B 6B

Figure 5-2, Test Module Usage

SATO D508/D512 Service Manual

Page 5-5

Page 86

Unit 5: Adjustment Procedures

PRINTER COUNTER CLEAR This procedure clears the internal cycle counters of various components and returns their values to zero. 1

Open the Top Cover and remove the front cover.

2

Set the DSW5 dip switch to the ON position. NOTE: Refer to Figure 5-1 for visual assistance in performing this procedure.

3

Press and hold the LINE and FEED buttons while switching ON the printer.

4

Release the LINE and FEED buttons when a beep sounds.

5

Switch OFF the DSW5 dip switch and latch the Top Cover closed. NOTE: When the Top Cover is closed, the clear process will automatically be initialized. During the clear process, the printer will be in an offline state. Press the LINE button to test print a large label and the FEED button to test print a small label.

NOTE: Pressing the FEED button pauses test printing activity. Allow a minimum of two labels to be printed before terminating to ensure the clear process was successful.

CUTTER COUNTER CLEAR (IF CUTTER IS INSTALLED) 1

Open the Top Cover and remove the front cover.

2

Switch the DSW6 dip switch to the ON position. NOTE: Refer to Figure 5-2 for visual assistance in performing this procedure.

3

Press and hold the LINE and FEED buttons while switching ON the printer.

4

Release the LINE and FEED buttons when a beep sounds.

5

Switch OFF the DSW6 dip switch and latch the Top Cover closed. NOTE: When the Top Cover is closed, the clear process will automatically be initialized. During the clear process, the printer will be in an offline state. Press the LINE button to test print a large label and the FEED button to test print a small label.

NOTE: Pressing the FEED button pauses test printing activity. Allow a minimum of two labels to be printed before terminating to ensure the clear process was successful.

Page 5-6

SATO D508/D512 Service Manual

Page 87

Unit 5: Adjustment Procedures

TEST PRINT COUNTER CLEAR 1

Open the Top Cover.

2

Press and hold the LINE and FEED buttons while switching ON the printer.

3

Release the LINE and FEED buttons when a beep sounds.

4

Latch the Top Cover closed. NOTE: When the Top Cover is closed, the clear process will automatically be initialized. During the clear process, the printer will be in an offline state. Press the LINE button to test print a large label and the FEED button to test print a small label.

NOTE: Pressing the FEED button pauses test printing activity. Allow a minimum of two labels to be printed before terminating to ensure the clear process was successful.

CUT POSITION (IF CUTTER IS INSTALLED) 1

Open the Top Cover and remove the front cover.

2

Switch the DSW6 dip switch to the OFF position and adjust the VR1 potentiometer to its center position. NOTE: Refer to Figure 5-2 for visual assistance in performing this procedure.

3

Press and hold the FEED button while switching ON the printer.

4

Release the LINE and FEED buttons when a beep sounds.

5

Press either the LINE or FEED button to print a test label. NOTE: Press the LINE button to test print a large label and the FEED button to test print a small label. Pressing the FEED button pauses test printing activity.

6

Use the printed test label to determine the required direction for the desired adjustment.

7

Adjust the VR1 potentiometer accordingly and repeat the test print process.

8

Repeat steps 3 through 5 until a proper offset adjustment is achieved.

SATO D508/D512 Service Manual

Page 5-7

Page 88

Unit 5: Adjustment Procedures

EYE MARK / PAPER END SENSOR SENSITIVITY 1

Open the Top Cover and remove the front cover.

2

Turn the VR2 potentiometer fully counter-clockwise.

3

Connect the Test Module to the test connector on the printer’s test panel. NOTE: Refer to Figure 5-2 for visual assistance in performing this procedure.

NOTE: Use of the Test Module on this printer also requires the use of a connector adapter cable that should also be purchased with the module.

4

Connect the multimeter ground probe to the pin identified as GND on the test module.

5

Connect the multimeter positive probe to the pin identified as SIG on the test module.

6

Set the multimeter to DC Voltage mode and turn the test module dial to position 4.

7

Physically place the media’s reference point into the sensor.

8

Adjust the VR2 potentiometer until the multimeter displays a value of +0.5 V ± 0.2 V.

9

Remove the label from the sensor and confirm that the voltage displayed is now 0.9 volts above the previous reading.

10 Repeat steps 7 through 9 until a acceptable sensitivity level is established.

PAPER END SENSOR SENSITIVITY (ALTERNATE) CAUTION: Care should be taken not to short the pins on the test connector. Damage to the PCB board could occur if the pins are shorted. 1

Open the Top Cover and remove the front cover.

2

Turn the VR2 potentiometer fully counter-clockwise.

3

Connect an insulated multimeter ground probe to pin 3 (GND) on the test connector.

4

Connect an insulated multimeter positive probe to pin 2 on the test connector.

5

Set the multimeter to DC Voltage mode.

6

Physically place the media into the sensor.

7

Adjust the VR2 potentiometer until the multimeter displays a value of +0.5 V ± 0.2 V.

8

Remove the label from the sensor and confirm that the voltage displayed is now 0.9 volts above the previous reading.

9

Repeat steps 7 through 9 until an acceptable sensitivity level is established.

Page 5-8

SATO D508/D512 Service Manual

Page 89

Unit 5: Adjustment Procedures

GAP SENSOR SENSITIVITY 1

Open the Top Cover and remove the front cover.

2

Turn the VR3 potentiometer fully counter-clockwise. NOTE: Refer to Figure 5-2 for visual assistance in performing this procedure.

3

Connect the Test Module to the test connector on the printer’s test panel. NOTE: Use of the Test Module on this printer also requires the use of a connector adapter cable that should also be purchased with the module.

4

Connect the negative multimeter ground probe to the pin identified as GND on the test module.

5

Connect the multimeter positive probe to the pin identified as SIG on the test module.

6

Set the multimeter to DC Voltage mode and turn the test module dial to position 3.

7

Physically place the media’s reference point into the sensor.

8

Adjust the VR3 potentiometer until the multimeter displays a value of +0.5 volts or less.

9

Physically move the media so that its printable surface is over the sensor.

10 Confirm the voltage displayed on the multimeter is now +1.0 volts or greater. 11 Repeat steps 7 through 10 until a acceptable sensitivity level is established.

GAP SENSOR SENSITIVITY (ALTERNATE) CAUTION: Care should be taken not to short the pins on the test connector damage to the PCB board could occur if the pins are shorted. 1

Open the Top Cover and remove the front cover.

2

Turn the VR3 potentiometer fully counter-clockwise.

3

Connect an insulated negative multimeter ground probe to pin 3 (GND) on the test connector.

4

Connect an insulated positive multimeter positive probe to pin 1 on the test connector.

5

Set the multimeter to DC Voltage mode.

6

Physically place the media's reference point or gap into the sensor.

7

Adjust the VR3 potentiometer until the multimeter displays a value of +0.5 volts or less.

8

Physically move the media so that its printable surface is over the sensor.

9

Confirm the voltage displayed on the multimeter is now +1.0 volts or greater.

10 Repeat steps 7 through 10 until an acceptable sensitivity level is established. 11 Repeat steps 7 through 10 until a acceptable sensitivity level is established.

SATO D508/D512 Service Manual

Page 5-9

Page 90

Unit 5: Adjustment Procedures

POWER SUPPLY CHECKS Obtain a DC Multimeter and Number 2 Phillips screwdriver for this check. To check voltage levels, first check the Main PCB fuse (see next page) and replace it if necessary. Then follow the steps below: 1

Turn the printer OFF.

2

Set the multimeter to DC mode.

3

Attach the negative (-) lead from the multimeter to Pin 3 (GND) of CN3 on the configuration panel.

4

Attach the positive (+) lead from the multimeter to Pin 4 of CN3 on the configuration panel.

5

Turn the printer ON.

6

Confirm that the voltages are correct. If not, remove the power connector from the rear of the printer, connect the test probes to Pin 1 (+) and Pin 4 (-) and measure the voltages.

Ideal Voltage

Test Points

Voltage Range

+ 5.0 V

Pin 3 (GNC) of CN3 Pin 4 of CN3

+4.8 V to +5 V

7

Pin 3 GND Pin 4 +5 V

CN3 Pin 1 GAP Pin 2 Eye

Power Supply Connector

If the voltages are not correct, replace the power supply.

Page 5-10