Page 19

Model L1000 Laser InspectorTM

Operator’s Guide

The next selection is : Database Storage XX kb XX kb Enter the percentages. (See the following note.) Note: Storage and Database buffers are two separate areas but each shares a total of 20K of memory. For example, if 5K of memory is used for Storage, the Database buffer will have 15K. If 15K of memory is used by the Database, Storage will have 5K. Allocations are made in blocks of 5K.

The next selection is: Scans/Analysis XXXXX From this screen choose the number of scans (from 2 to 10) to be used in the analysis. Or Select “Single” for a single scan, or “Continuous” for continuous scanning.

See 8.1 Continuous and Multi-scan modes

002-5568

13

RJS, Minneapolis, MN

Page 20

Model L1000 Laser InspectorTM

Operator’s Guide

The last menu setup selection is: Comparison Mode OFF

Note: Comparison Mode is not accessed if “Continuous” scans/analysis mode is enabled.

Selecting ON in the Comparison Mode causes the next scanned symbol to be the “target.” A “No Match” will display when subsequent symbols do not match the “target.” To generate a new “target” while remaining in the Comparison Mode, toggle the Comparison Mode selection to OFF and then to ON again. When all Setup selections have been made, the Laser Inspector will navigate back to the Main Menu automatically.

Note: All setup parameters are retained in non-volatile memory and will you - even after the power is turned off.

RJS, Minneapolis, MN

14

002-5568 be saved until changed by

Page 21

Model L1000 Laser InspectorTM

Operator’s Guide

5.3 Storage Storage is used to hold scan data for future print or review. Up to approximately 75 barcodes may be held in storage. From the main menu press Enter and Select at the same time the following will be displayed. Scan Setup Database/Storage

Select Database and press Enter The display will show either “Storage Inactive” or “Storage %.”

Database Empty Storage Inactive Store and Print is inactive Scan Setup Storage XX% Store and Print is active If a % is displayed, it represents the percentage of the buffer that is filled with scan data.

You may enable or disable Store and Print by pressing Enter with the cursor on Storage. (Toggle from one option to the other.) When Storage is active, press Select to move the cursor to the % sign. Press Enter on the % sign to clear the Store and Print buffer.

002-5568

15

RJS, Minneapolis, MN

Page 22

Model L1000 Laser InspectorTM

Operator’s Guide

5.4 Storage and Database A special serial interface cable that connects to your personal computer is available (Part Number 002-2979). The Database function is used to validate barcode data or compare barcode data to a predefined description that is placed into the database. When using the Database function the barcodes that are scanned must be in the database on the L1000; otherwise, the following message will display (unless the database function is turned off): Data Base Record Does Not Exist The Model L1000 contains 20K of memory that is used by Storage and the Database. All or part of this 20K can be used by the Database (the remainder is used as Storage). With the L1000, a database file can be created on a PC. The file consists of barcode data and display messages (described later in this section). Download this database (using a serial communication port) from the PC to the Inspector unit. Scans may then be performed. As a barcode is scanned, the Inspector unit’s database is searched for a match. When a match is found, the message from the database (that was previously entered) will display along with the verification analysis. The Storage function is used to hold barcode data, to be printed or reviewed later. Up to approximately 75 barcodes may be held in storage. Please note that Database and Storage percentages are allocated in the Setup menus explained in a previous section.

RJS, Minneapolis, MN

16

002-5568

Page 23

Model L1000 Laser InspectorTM

Operator’s Guide

The database function is defaulted to OFF and becomes active when data is placed in the database. The storage function is activated or deactivated in the Database/Storage menus explained in this section. SCAN SETUP DATABASE/STORAGE

Press Select until the cursor is on the Database/Storage option Press Enter to initiate the option

002-5568

17

RJS, Minneapolis, MN

Page 24

Model L1000 Laser InspectorTM

Operator’s Guide

Database XX Storage YY The cursor will be on the “D” in database. The “Xs” in the above sample represent one of the following displays for the database: EMPTY (There is no data in the database buffer) XX% (Percentage of active database buffer that is filled, 0 - 99%) The “Ys” in the above sample represent one of the following displays for storage: Inactive (Store and Print buffer not enabled) YY% (Percentage of active storage buffer that is filled, 0 - 99%) 0 KB (No storage was reserved in the Setup procedure) With the cursor on Storage, press Enter to toggle the Storage function between enabled and disabled. When Storage is activated, by pressing Select, the cursor will position to the percentage sign (%). To clear the storage buffer, press Enter with the cursor on the % sign00% will display. (Press Enter again if you cleared the buffer by mistake.) Press Select again to return to the Main Menu. Note: For an explanation about printing the contents of the Store and Print buffer See Appendix E. Note: Deactivating the database function does not alter the contents of the database buffer. See Appendix J (Downloading Data).

RJS, Minneapolis, MN

18

002-5568

Page 25

Model L1000 Laser InspectorTM

Operator’s Guide

6.0 Scanning Symbols To scan a barcode simply pull the trigger and position the beam across the symbol. A crisp, clear chirp (or beep) sound will indicate a good read. See Appendix H for details.

Decoded data and symbology type will display: *01928374* ANSI I 2 of 5

Press Enter to navigate to the Pass/Fail Analysis screen, then begin pressing Select to scroll through the analysis screens. ANSI I 2 of 5 Acceptable

(See Pass/Fail Analysis Screen section)

002-5568

19

RJS, Minneapolis, MN

Page 26

Model L1000 Laser InspectorTM

Operator’s Guide

7.0 Pass/Fail Analysis Screen After a symbol is scanned the Pass/Fail Analysis Screen may be displayed. (See 6.0 Scanning Symbols) Note: Even though your Inspector may have a 4 row display, only 2 are currently used and only 2 are shown in the examples.

An example of an analysis screen for an acceptable symbol is shown below: 01928374 ANSI I 2 of 5

The upper row is the decoded data. (If more than 16 characters are present, those characters will wrap to the next row of the display.) Press Select to scroll through the data. If the symbology code is 128 or 93, only printable characters will be displayed. See Appendices A and B for descriptions of how these codes are displayed. The lower row provides the following: Symbology type (if symbol acceptable) See Table 1. Symbology type and warning or rejected message (if symbol not acceptable) See Table 2. Scans remaining in multiple scan mode if the last scan has not been completed.

RJS, Minneapolis, MN

20

002-5568

Page 27

Model L1000 Laser InspectorTM

Operator’s Guide

Table 1 (Code Identifiers Laser Inspector ) Displays LOGMARS AIAG B-1 AIAG B 3/4/5 ANSI 3 of 9 HIBC 3 of 9 3 of 9 w/43 ANSI I 2 of 5 Case Code Codabar Variant Code 93 Code 128 128 Case Code X - Y % UPC-A X - Y % UPCA+2 X - Y % UPCA+5 X - Y % UPC-E X - Y % UPCE+2 X - Y % UPCE+5 X - Y % EAN-13 X - Y % EAN13+2 X - Y % EAN13+5 X - Y % EAN-8 X - Y % EAN8+2 X - Y % EAN8+5

Type Code 39 Symbology Code 39 symbology Code 39 symbology Code 39 symbology (AIM Spec.) Code 39 symbology Code 39 symbology Interleaved 2 of 5 Interleaved 2 of 5 Codabar (AIM Specification) Code 93 (AIM Specification) Code 128 (AIM Specification) UCC 128, AI 00 Uniform Product Code, Ver. A Uniform Product Code, Ver. A with 2 digit addendum Uniform Product Code, Ver. A with 5 digit addendum Uniform Product Code, Ver. E Uniform Product Code, Ver. E with 2 digit addendum Uniform Product Code, Ver. E with 5 digit addendum European Article Number 13 digit European Article Number 13 digit with 2 digit addendum European Article Number 13 digit with 5 digit addendum European Article Number 8 digit European Article Number 8 digit with 2 digit addendum European Article Number 8 digit with 5 digit addendum

Note: (Previous Tables) All ANSI symbologies are traditional specifications using bar width deviation. X and Y represent the magnification range selected for UPC/EAN tolerances.

002-5568

21

RJS, Minneapolis, MN