Page 19

CHAPTER 3. USING JDEMO AND JSETUP 3.1

JDEMO

On the disk that accompanies this manual, you will find a file called JDEMO.EXE. This program will demonstrate some of the features of the QTERM. When you execute this file, your QTERM should be connected to a COM port on your PC. JDEMO will display a list of COM ports so that you can specify which COM port you are using. Then you will select the baud rate and data format the same way. Once you are done with the setup menus, then JDEMO will display a menu of the features that can be demonstrated.

3.2

JSETUP

3.2.1

Setting Parameters

There are two different ways to change the parameters of your QTERM and make them permanent. ! You can send software commands as described in chapter 2, and then save the setting to EEPROM using the Save Parameters to EEPROM command (] i). ! You can store the commands necessary to change the parameters in a data file and load the data file into the terminal using JSETUP. The rest of this chapter deals with using JSETUP to configure your terminal. 3.2.2

Using JSETUP to Change Parameters

JSETUP is a program that is included with this manual on a PC-compatible disk. With JSETUP it is possible to change some of the terminal parameters and use the new values as the power-up default values. JSETUP works by reading the parameter values from an ASCII text file; this file’s extension must be “.DAT”. A default example of this data file, called CONFIG.DAT, is included with JSETUP on the floppy disk. This file con-tains some ASCII strings that will be sent to the terminal which are actually software commands. These commands can be edited before running JSETUP to allow you to set some parameter values of the terminal. 3.2.3

Modifying the Data File

Using a standard DOS text file editor, you can edit the CONFIG.DAT file. You can also change the name of the file as long as it retains the .DAT extension. Any line beginning with a semi-colon will be ignored as a comment. Each line in the data file will be sent to the terminal exactly as it is typed with the following exceptions: ! The] character is represented by <esc>. ! Any hex value can be sent using the brackets to enclose the value, such as <x0D> for a carriage return. When you are done editing the data file, save it to disk. 3.2.4

Running JSETUP

To run JSETUP, first you must connect your terminal to your PC’s COM port and supply power to it. If you do not have an EIA-232 QTERM, you will need an interface unit. See Chapter 1 for more information on powering your terminal and communicating with it. When you are ready to configure your terminal, run the JSETUP.EXE program. You will have the option to select the COM port to which your terminal is connected, as well as the baud rate and data format if needed. When you select the upload option, JSETUP will ask you for the file name of the data file you wish to use. Type in the filename but do not type the ".DAT" extension. JSETUP will then read the text from the data file and send it to the terminal. When JSETUP is done, you will return to the

QSI Corporation • Fax 801-466-8792 • www.qsicorp.com • Phone 801-466-8770

Page 20

12

QTERM-J10/N15 User's Manual main menu. At this point your terminal is done being configured, and you can exit the program. If the very last command in your data file is the <esc>i command, then the settings that were programmed into the terminal will now remain as the new defaults every time the terminal is powered up. If you wish to restore the terminal to its original factory default configuration, you can issue the Restore Factory Defaults software command (] r). This will return all the parameters to the original factory default except for baud rate and data format.

QSI Corporation • Fax 801-466-8792 • www.qsicorp.com • Phone 801-466-8770

Page 21

CHAPTER 4. QTERM-J10/N15 HARDWARE 4.1

QTERM-J10 Handheld Terminal

The dimensions of the QTERM-J10 handheld terminal are shown in Figure 4-2.. This figure also shows the standard keypad legend for the keys on the 40-key keypad.

shows the pin numbering for the connectors used on the QTERM-J10. For reference, Table 4-4. (at the end of this chapter) shows the pin assignments used by the COM ports on PC-style computers for both DB25 and DB9 connectors.

4.2 The housing is made from impact-resistant ABS, and is colored black. The housing is not waterproof, but it can be subjected to moderate rain or splash without harm. The QTERM-J10 handheld terminal uses a 6-pin modular connector, exiting from the bottom of the housing. If desired, the modular connector can easily be switched to exit from the top of the QTERM-J10 housing.

QTERM-J10 Panel-Mount Terminal

The panel-mount QTERM-J10 is mounted directly onto your instrument or enclosure. Figure 4-2. shows the dimensions of the panel-mount QTERM-J10 along with the standard keypad legend for the 24-key keypad. The QTERM-J10 is mounted to the panel by placing the terminal into the panel cutout, and attaching the mounting

The pin assignments for the connectors for each of the available interfaces are shown in Table 4-1.. Figure 4-2.

brackets behind the panel with the four self-tapping screws. A mounting gasket is provided in order to seal the front 33.2

105.9

45.2

194.9

88.2

29.2

40.6

Handheld

Battery Back

Figure 4-2. Dimensions of the QTERM-J10 handheld version (mm).

QSI Corporation • Fax 801-466-8792 • www.qsicorp.com • Phone 801-466-8770

Page 22

14

QTERM-J10/N15 User's Manual

6-Pin Modular Connector

DB9 Female

Panel-Mount 2 mm Connector

Figure 4-2. QTERM Connector Pin Assignments. edge of the terminal. Figure 4-2. shows the assembly diagram, along with the panel cutout dimensions required for mounting. Connection to the panel-mount QTERM-J10 is made via a DB9 female connector which is accessible from the rear of

4.3

QTERM-N15 Panel Mount Terminal

The panel-mount QTERM-N15 is mounted directly onto your instrument or enclosure. Figure 4-2. shows the dimensions of the QTERM-N15 along with the standard keypad legend for the keypad.

the mounting cover. The pin assignments for the DB9 connector on the QTERM-J10 are shown in Table 4-1.. The

The QTERM-N15 is mounted to the panel by placing the connector pin numbering is shown in Figure 4-2..

terminal into the panel cutout, and attaching the mounting

Figure 4-2. Dimensionsions of the QTERM-J10 panel-mount version (mm).

QSI Corporation • Fax 801-466-8792 • www.qsicorp.com • Phone 801-466-8770

Page 23

QTERM-J10/N15 User's Manual

15

Figure 4-2. QTERM-J10 assembly and panel cutout dimensions (mm).

109

6

109.0 (ref.) 74.0

29

132.7

151

151.1 (ref.)

DB9 Connector

15.0

9.5 90.0

Figure 4-2. Dimensions of the QTERM-N15 panel-mount version (mm). brackets behind the panel with the four self-tapping screws. QSI Corporation • Fax 801-466-8792 • www.qsicorp.com • Phone 801-466-8770

Page 24

16

QTERM-J10/N15 User's Manual

Panel Mounting Gasket

102.8±1.0 Back Mounting Panel #6-32 Nut with Lockwasher

QTERM-N15 Terminal

3.2 [0.125"] radius permissible

145.0 ±1.0 3.1 typical all around (ref. perimeter of mounted panel)

DB9 Output Cable

Typical Assembly

Panel Cutout Dimensions

Figure 4-2. QTERM-N15 assembly and panel cutout dimensions (mm). A mounting gasket is provided in order to seal the front

4.4.2

EIA-422 Interface edge of the terminal. Figure 4-2. shows the assembly diagram, along with the panel cutout dimensions required for

With proper cables and grounding, the EIA-422 interface mounting.

can communicate up to a distance of about 1,000 meters. The EIA-422 version of the QTERM uses four communica-

Connection to the panel-mount QTERM-N15 is made via a DB9 female connector which is accessible from the rear of the mounting cover. The pin assignments for the DB9 connector on the QTERM-N15 are shown in Table 4-1.. The connector pin numbering is shown in Figure 4-2..

tion lines and two power lines. 4.4.3

5-volt Buffered Interface

When used to communicate with another 5-volt Buffered device, the QTERM can operate at distances up to about 5

4.4

Interfaces meters. The advantage of the 5-volt Buffered QTERM is that it draws less current than the EIA-232 version, and

4.4.1

EIA-232 Interface uses the same 5-volt logic levels that come directly out of a UART (i.e. the idle state is at 5 volts, and the active state is

With proper cables and good grounding, the EIA-232 inter-at 0 volts).

face on the QTERM can communicate up to about 15 meters.

4.5

The QTERM does not monitor or control any of the EIA-

The QTERM display is a 4-line by 20-character supertwist LCD unit. The entire 128-byte ASCII character set can be displayed. Hosts which transmit 8-bit data can also display an additional 64 characters including Greek letters, katakana characters, non-English alphabetic characters and math symbols.

232 modem-control lines (such as RTS and DTS). Handshaking between the host computer and the QTERM is done using software XON/XOFF commands. The XON/ XOFF operation can be disabled (via software commands)

LCD Display if you do not wish to have it operate.

QSI Corporation • Fax 801-466-8792 • www.qsicorp.com • Phone 801-466-8770

Page 25

QTERM-J10/N15 User's Manual

17

Table 4-1. QTERM Pin Assignments. 6-pin Modular Connector

DB9 Female

Panel-Mount 2 mm Connector

QTERM EIA-232/5-volt Buffered Function

QTERM EIA-422 Function

1

3

1 receive

+receive

2

6

2 no connection

-receive

3

2

3 transmit

+transmit

4

1

4 no connection

-transmit

5

9

5 power power

6

5

6 ground ground

Appendix B is a chart which shows what the QTERM does with every possible 8-bit value it can receive. Note that the ASCII portion of the chart (the first 128 characters) is similar, but not identical, to the true ASCII chart shown in Appendix A. If you ordered the backlight, the software commands shown in Chapter 2 will allow you to turn the backlight on and off. Without the backlight, these commands have no effect. 4.6

4.7

Other Options

4.7.1

Buzzer Option

If you order the buzzer option, the QTERM includes an audio buzzer which is used for key beeps, and for beeping in response to a “bell” character (^G, 07h). 4.7.2

Regulator Option

The standard QTERM requires a 5-volt regulated power source. An optional regulator allows the QTERM to be operated from a 7.5-volt to 24-volt DC source.

Keypad

The QTERM-J10 is available with an 18-key, 24-key or a 40-key keypad. The QTERM-N15 comes with a 12-key keypad. When each key is pressed, the QTERM will send a single ASCII character through the serial interface. Some keys such as F1-F5 and the arrow keys do not have an ASCII printable equivalent, so instead they will send a single lower case letter. Each keypad has a graphic overlay with labels for each key. Table 4-3. lists the default values assigned to each key for all three keypad versions.

4.8

QTERM Specifications

Environmental characteristics of the QTERM-J10 and QTERM-N15 are: ! -10 to +60 °C operating temperature range ! -40 to +85 °C storage temperature range ! 0 to 95% non-condensing humidity range

The keypad utilizes membrane dome keys for long life and tactile feedback to the operator. Each of the keys sends one or two bytes when pressed. Table 4-2. QTERM-J10/N15 Current Consumption. Software commands allow you to control both key beeps (on or off) and key repeat (on or off).

Version

Ireg (mA)

EIA-232 Version

28

EIA-422 Version

25

Add for regulator

6

Add for backlight

60

QSI Corporation • Fax 801-466-8792 • www.qsicorp.com • Phone 801-466-8770

Page 26

18

QTERM-J10/N15 User's Manual

Table 4-3.Key Assignments. Key

ASCII Char

Hex Byte

Key

ASCII Char

Hex Byte

Key

ASCII Char

Hex Byte

F1 e

65h

Q

Q

51h

0

0

30h

F2 f

66h

R

R

52h

1

1

31h

F3 g

67h

S

S

53h

2

2

32h

F4 h

68h

T

T

54h

3

3

33h

F5 i

69h

U

U

55h

4

4

34h

A

A

41h

V

V

56h

5

5

35h

B

B

42h

W

W

57h

6

6

36h

C

C

43h

X

X

58h

7

7

37h

D

D

44h

Y

Y

59h

8

8

38h

E

E

45h

Z

Z

5Ah

9

9

39h

F

F

46h

/

/

2Fh

SPACE

20h

G

G

47h

-

-

2Dh

ENTER

0Dh

H

H

48h

+

+

2Bh

UP a

61h

I

I

49h

(

(

28h

DOWN b

62h

J

J

4Ah

)

)

29h

RIGHT c

63h

K

K

4Bh

#

#

23h

LEFT d

64h

L

L

4Ch

*

*

2Ah

SHIFT

N/A

M

M

4Dh

,

,

2Ch

BACK

7Fh

N

N

4Eh

.

.

2Eh

HOME j

6Ah

O

O

4Fh

ESC

1Bh

CLEAR k

6Bh

P

P

50h

DEL

7Fh

Table 4-4.Pin Assignments for PC-Style COM Ports. COM Ports with Male DB25 Connectors

COM Ports with Male DB9 Connectors

Pin

Pin

Function

Function

2 PC transmit 1 CD * 3 PC receive 2 PC receive 4 RTS * 3 PC transmit 5 CTS * 4 DTR * 6 DSR * 5 ground 7 ground 6 DSR * 8 CD * 7 RTS * 20 DTR* 8 CTS * 22 RI * 9 RI * * These lines normally can be left unconnected. Some PCs may require that one or more of them be pulled to 5 volts through a pull-up resistor (about 300 ohms).

QSI Corporation • Fax 801-466-8792 • www.qsicorp.com • Phone 801-466-8770

Page 27

APPENDIX A. ASCII CHART

0

1

2

3

4

5

6

7

0 NUL DLE SP 1 SOH DC1 ! 2 STX DC2 " 3 ETX DC3 # 4 EOT DC4 $ 5 ENQ NAK % 6 ACK SYN & 7 BEL ETB ' 8 BS CAN ( 9 HT EM ) A LF SUB * B VT ESC + C FF FS , D CR GS E SO RS . F SI US /

0

@

P

` p

1

A

Q a q

2

B

R b r

3

C

S c s

4

D

T d t

5

E

U e u

6

F

V f v

7

G

W g w

8

H

X h x

9

I

Y i y

:

J

Z j z

;

K

[ k

{

<

L

\ l

|

=

M

] m

}

>

N

^ n

~

?

O

_ o

DEL

NUL = blank SOH = start of header STX = start of text ETX = end of text EOT = end of transmission ENQ = enquiry ACK = acknowledge BEL = bell BS = backspace HT = horizontal tab LF = line feed VT = vertical tab FF = form feed CR = carriage return SO = shift out SI = shift in SP = space DLE = data link escape DC1 = device control 1 (XON) DC2 = device control 2 DC3 = device control 3 (XOFF) DC4 = device control 4 NAK = negative acknowledge SYN = synchronization ETB = end of text block CAN = cancel EM = end of medium SUB = substitute ESC = escape FS = file separator GS = group separator RS = record separator US = unit separator DEL = delete/rubout

QSI Corporation • Fax 801-466-8792 • www.qsicorp.com • Phone 801-466-8770