Page 37

CHAPTER 4 QTERM-Z60 TERMINAL

4.1 Product Description The QTERM-Z60™ terminal is an economical graphic terminal with object-based programming. Two different models of the QTERM-Z60 exist to suit any environment and budget. In general, the Z60/H version is NEMA-4 rated and has a user-selectable serial port while the Z60/L is NEMA12 rated, has one EIA-232 serial port and a slightly different display. The QTERM-Z60 features a QVGA, 320x240 pixel, 256 color STN color LCD display. It uses a cold-cathode fluorescent backlight (CCFL). The CCFL provides high contrast and easy readability and is replaceable. The contrast is software controlled and temperature compensated. The analog-resistive touch screen covers the full viewable area of the display as well as the pre-labeled legend underlay around the display. The QTERM-Z60/H is equipped with one user-selectable serial port (EIA-232, EIA-422, or EIA-485). The interface is selected using DIP switches. The QTERM-Z60/L is equipped with one EIA-232 serial port. A speaker, which has programmable pitch and duration, comes standard as does a 5 VDC 200 mA output from the interface connector to power external devices. An external reset signal also comes standard to allow other devices to reset the QTERM-Z60. The QTERM-Z60 terminal stores firmware and user applications in a compressed format in flash memory and then transfers them to RAM memory when the terminal is powered on. The terminal is equipped with two megabytes of flash memory and sixteen megabytes of RAM memory. The QTERM-Z60 terminal requires a DC power source ranging from 8 to 32 VDC. This power is supplied via the main interface connector.

TERMINAL DISPLAY Standard

STN 256 colors

Pixels

320 x 240

Dot Pitch

0.36 mm

Contrast

Software controlled, temperature compensated

Lighting

Cold-cathode fluorescent, brightness is softwarecontrollable

Backlight Brightness

200 nits typical

TOUCH SCREEN Analog-resistive operation Transparent touch area over viewable display Labeled touch underlay area on each side of display INTERFACE Z60/H

EIA-232, -422 or -485 serial port

Z60/L

EIA-232 serial port

Baud rates

600 – 115,200 bps

Data formats

7 or 8 data bits 1 or 2 stop bits Even, odd, or no parity (PC Tools support only 8 data bits)

Connector

Molex 43045-1218

Mating Connector Molex 43025-1200 Mating Connector Molex 43030-0001 Pins MEMORY Standard

2 Mbytes flash and 16 Mbytes SDRAM SPEAKER

Standard

Software programmable pitch and duration

4.1.1 Specifications The following tables contain the technical specifications for the QTERM-Z60.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 38

30

QSI Qlarity-based Terminal Hardware

PHYSICAL

NOTE: The serial port is wired as Data Communications Equipment (DCE)

Configuration Panel-mount Housing

Glass-filled polyester, UL 94V-0 flame rating, accommodates panels from 0 to 7 mm thick with standard screws

Size

215 x 161 x 50 mm

Weight

0.98 kg

Processor

ARM 720T 77 MHz

The interface is selected using DIP switches. The following table shows the dip switch settings. Dip Switch Settings

ENVIRONMENTAL QTERM-Z60/H Sealing NEMA-4 front panel QTERM-Z60/L Sealing NEMA-12/13 front panel Temperature

Operating: 0 to 50 ° C Storage: -10 to 60 °C

Humidity

0 to 95%, non-condensing

Vibration

5 to 5000 Hz, 4 g RMS

Shock

20 g, 3 ms, any axis

1

2

3

4

5

6

7

8

EIA-232 off off off off off on off off

EIA-422 off off off off on off off off

EIA-485 on on on on on off off off

The figure below shows the serial connector’s orientation .

POWER 8 to 32 VDC (See section 4.4.3 for current consumption)

12

7

6

1

SOFTWARE Programming language

Qlarity™ (object-based)

Design environment

Qlarity Foundry™ (Windows®)

Connector Detail (Back of Unit)

Command line compiler Qlarify (Win32® or Linux) CERTIFICATION FCC Part 15, Class A CE Certification

.h

EIA-232 with proper cables and grounding the terminal can communicate up to five meters at a top speed of 115,200 bps

EIA-422 permits operation at distances up to 2,000 meters

EIA-485 permits multiple terminals to be connected in a multi-drop chain

4.2 Supported Interfaces 4.2.1 Serial Ports The QTERM-Z60/H comes standard with one user-selectable serial port. The serial port interface can be selected via dip switches (EIA-232, EIA-422 or EIA-485). The QTERM-Z60/L is equipped with one EIA-232 serial port.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 39

QSI Qlarity-based Terminal Hardware

The following table shows the pinouts for the interface connector. Pin

Function

1

Power In

2

RS-232 TX (out)

3

EIA-422 TX+ (out)

4

EIA-422 RX+ (in), or EIA-485 RTX+

5

5 VDC output

6

No Connect

7

Ground

8

RS-232 RX (in)

9

EIA-422 TX- (out)

10

EIA-422 RX- (in), or EIA-485 RTX-

11

External Reset (in)

12

No Connect

31 minal for your application for shipments of over one hundred.

Touch keys can also be defined in your user applications at any location on or around the display. Touch keys may be any size. 4.3.2 Speaker

Pin 5 of the interface connector is a 5 VDC power supply and can supply up to 200 mA current to a serial peripheral device (such as a barcode reader). The ground return for the supply is on pin 7 of the interface connector.

A speaker is built into the QTERM-Z60 terminal and faces to the back of the unit. Audio can be linked to events or actions (e.g., screen press, timer, etc.). Pitch and duration are controlled by API functions called from the user application. Refer to “Controlling the Speaker” section in the Qlarity-based Terminal Programmer's Reference Manual.

4.2.3 External Reset Input

4.3.3 System Memory

Pin 11 of the interface connector is a reset signal compatible with 5 VDC and 3.3 VDC logic signals. By applying a 3.3 VDC or 5 VDC pulse to this input, the terminal will perform a complete hardware reset.

The QTERM-Z60 terminal stores the firmware and user applications in a compressed format in flash memory and then transfers them to RAM memory when the terminal is powered on. Two megabytes of flash memory and sixteen megabytes of RAM memory are standard.

4.2.2 Five Volt Power Supply Output

4.3 Terminal Components 4.3.1 Touch Screen The QTERM-Z60 touch screen provides user input through any number of touch keys located on or around the display. The standard key legend shown in the figure below provides areas for five soft keys down each side of the display. A custom legend underlay can be ordered to personalize the ter-

For information on using resources efficiently to conserve memory when creating a user application, refer to “Edit Resources” section in the Qlarity Foundry User’s Manual. For information on downloading new firmware, downloading a user application, and determining the size of a user application, refer to the Qlarity Foundry User’s Manual.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 40

32

QSI Qlarity-based Terminal Hardware

4.4 Installing the QTERM-Z60 Terminal to NEMA-4 Specifications

Following is a diagram of the landscape cutout: 199 + –1

A QTERM-Z60 terminal uses a rugged, glass-filled polyester (UL 94V-0) case designed to mount into a panel. When properly installed in a NEMA-4 rated panel, the QTERMZ60 meets all NEMA-4 specifications including hose-down, icing, and salt spray.

Cutout

3.2 radius max.

145 + –1

A QTERM-Z60 terminal can be installed in either a landscape or portrait orientation. When installing a terminal, you generally take the following steps.

• Decide whether you want to mount and use the terminal in a portrait or landscape orientation. “Portrait” means that the longest dimension is vertical; “landscape” means that the longest dimension is horizontal.

• Cut a hole in the panel See section 4.4.1, “Cutting Out the Panel” for specifications.

• Install the QTERM-Z60 terminal in the panel. See section 4.4.2, “Installing the Terminal” for instructions.

• Connect cables to the terminal. Verify that the thumb screws are tight or the locks snapped into place for each cable used.

File any rough edges smooth, especially on the face of the panel. 4.4.2 Installing the Terminal NOTE: Use of an anti-static strap is recommended when performing installation and maintenance. Take the following steps to install the terminal. Refer to the illustrations on the next page. 1.

Verify that the panel surface around the cutout is clean and free of rough edges. A gasket built into the terminal will seal against this surface. Dirt or imperfections on the panel may prevent a proper seal.

2.

Place the terminal into the panel cutout and verify that the terminal is oriented correctly. The touch screen legend may indicate the orientation. If not, you can determine which side should be at the top by the position of the serial port on the back panel as follows:

Apply DC power to the QTERM-Z60 terminal See section 4.4.3, “Applying Power” for information. 4.4.1 Cutting Out the Panel The QTERM-Z60 terminal can be mounted in panels from 0 to 7 mm thick. No screw holes need to be drilled to install the terminal in the panel. Make a rectangular hole in the panel using the following dimensions. Landscape: Horizontal Vertical

199 ± 1 mm 145 ± 1 mm

Portrait: Horizontal Vertical

145 ± 1 mm 199 ± 1 mm

Landscape: when looking at the front of the unit, the back panel serial port should be on the top of the terminal. Portrait: when looking at the front of the unit, the back panel serial port should be on the right side of the terminal. 3.

On the back of the panel, place the terminal mounting bracket against the back of the terminal, and align it with the back panel.

4.

Fasten the six screws (supplied with the terminal).

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 41

QSI Qlarity-based Terminal Hardware

33

QTERM-Z60/H / Z60/L Current Consumption Terminal

12 VDC

24 VDC

Standard unit, idle

390 mA

200 mA

Standard unit, active add 40 mA add 20 mA

Standard unit, add 140 mA add 70 mA 200 mA load on 5 VDC supply 4.4.4 Powering On the Terminal for the First Time When you connect power to the QTERM-Z60 terminal, it automatically loads the application saved in flash memory into RAM memory and displays the application. If no application is present, the terminal display may be blank but the backlighting verifies it is powered on. When you power on the terminal for the first time, a demo program (or a special application custom designed for your company) loads. The demo program will help you verify that the terminal is operating properly. Follow the on-screen prompts or any documentation accompanying the program to guide you through tests or demonstrations designed to verify terminal operation. Once you have verified that the terminal is functioning properly, refer to Chapter 5, “Power On Setup” for information on configuring your terminal. The Power On Setup utility includes functions to do the following:

4.4.3 Applying Power Power is supplied to the QTERM-Z60 terminal via the interface connector. Refer to section 4.2.1, “Serial Ports” for the pin assignments for power and ground. DC power must be in the range of 8 to 32 volts (the current will vary depending on the input voltage; see table that follows.

• Change orientation of the terminal (portrait or landscape) • Download a new user application to the terminal • Select the application mode • Set up communications settings for the terminal • Adjust display contrast or backlight • Enter/change password (if used)

QTERM-Z60 power must come from an SELV (Safety Extra Low Voltage) power CAUTION source and should have a current limit on its output of 5 Amperes. It must provide a minimum of 8 volts DC power and be limited to a maximum of 32 volts DC. Limiting may be inherent to the supply or may be provided by supplementary overcurrent devices. If the QTERM-Z60 does not respond or exhibits abnormal behavior on power up, disconnect power and contact QSI for technical support.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 42

34

QSI Qlarity-based Terminal Hardware

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770