Manage Finger IDs Select this option to manage your employees¶ finger templates. Note: See clock usage instructions for detailed instructions on managing finger templates. The following options appear under this menu: 1. NEW FINGER ID 2. DELETE 3. CHECK FINGER 4. GLOBAL SECURITY New Finger ID Select this option to enroll an employee¶s finger template. Delete This option allows you to delete the templates that are being stored by the time clock. Check Finger This option allows you to check an employee¶s existing finger templates. Global Security By default the global security level for finger IDs is set to 5, the highest level of security. If you wish to, you may change the global security setting, though this is not recommended.
Clock Setup This menu allows you to customize how your time clock functions by configuring various system options. See page 17 for a detailed breakdown of this menu and its options.
Reports This option allows you to view reports about your clock hardware and firmware versions, as well as information about the data that is being stored by the clock. There are six options on this screen: 1. CLOCK INFORMATION 2. STORAGE USED 3. SYSTEM VERSION 4. COMPANY INFORMATION 5. FINGER ID VERSION 6. DEFAULT SCHEDULES Clock Information This report shows the clock model, ID number and interface serial number.
3/24/2008
17 of 24
Page 18
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
Storage Used This report allows you to view the amount of memory that your clock is currently using. It displays the number of blocks used, and the number of packets stored. System Version This report allows you to view the clock¶s boot code version, along with the version date/time. Company Information Use this report to view any company information that has been uploaded to your clock from the TimeForce system (such as, company name and company message). Finger ID Version Use this report to view model and version information on your clock¶s finger ID reader. Default Schedules Use this information to view the default schedule information that has been uploaded to your clock from TimeForce.
Manage Memory This menu option gives you access to the memory of the time clock. From here, the following actions can be taken: 1. CLEAR DATA MEMORY 2. SET TO DEFAULTS 3. SCAN DATA MEMORY 4. CLEAR EMPLOYEE TIMES Clear Data Memory When this option is selected, the clock will erase all stored data. This includes any stored punches, as well as employee finger templates. Note: This procedure is irreversible. Any data that is cleared from the clock can never be recovered. Set to Defaults This option restores the clock to its default Clock ID and Password. Note: The ClockLink software uses the Clock ID and Password to communicate with your clock. The information specified in the Time Clock Profile must match the information set in the time clock itself. Scan Data Memory This option scans the data being stored by the time clock looking for data that is outside of its known pointers. If data is found, the pointers are reset to include the found data, making the information available for download. This option is intended for use by Qqest Technical Support.
3/24/2008
18 of 24
Page 19
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
Clear Employee Times This option clears all information that has been uploaded to the clock from the TimeForce system (such as employees, departments, default schedules, etc.). This option is not reversible. Once deleted, data must be re-uploaded to the clock using the ClockLink program.
Clock Setup This menu allows you to enable, disable and customize various time clock options. The main Clock Setup screen contains the following options: 1. COMMUNICATION 2. CLOCK ID/PASS 3. KEYPAD BEHAVIOR 4. FINGER ID DEVICES 5. EXTERNAL DEVICES 6. DISPLAY OPTIONS 7. PUNCH RESTRICTIONS
Communication The communications menu allows you to specify the settings that your clock uses to communicate. This screen varies depending on the communications type of your clock. See ³Hardware Installation´ on page 2 for detailed instructions on each clock type.
Clock ID/Pass This menu allows you to view and edit the ID and password that your clock uses to communicate. See ³How Do I Find the Clock ID and Password?´ on page 1 for detailed instructions on this menu.
Keypad Behavior This menu allows you to specify how the clock keypad functions, and contains the following options: 1. KEY CLICK 2. IN/OUT KEYS 3. MEAL/BREAK KEYS 4. KEY TONES 5. AUTO-ENTER ID Key Click Enable this option if you want the clock to emit a short beep every time a key is pressed. In/Out Keys This option enables the <IN> and <OUT> keys on the clock keypad. Enable this option if you would like your employees to be able to specify an ³in´ or ³out´ status with their punches.
3/24/2008
19 of 24
Page 20
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
Note: This option is not required. The TimeForce system automatically determines punch ³in/out´ order. Meal/Break Keys This option enables the <MEAL> and <BREAK> keys on the clock keypad. Enable this option if you would like to allow your employees to specify a punch as a ³meal´ or ³break´ punch. Key Tones This option allows you to enable or disable the tones that the clock emits when a punch is accepted. Note: It is not possible to disable punch error tones. Auto-Enter ID This option allows you to set the maximum number of digits for an ID. Example: The ³Auto-Enter ID´ setting is set to 3. As soon as the third digit in an ID is entered at the keypad, the punch is automatically entered (without pressing the <ENTER> key).
Finger ID Devices This menu allows you to configure the finger ID reader on your clock, and contains the following options: 1. SHOW SETTINGS 2. ENABLE READER 3. REQ. FOR MENUS Show Settings This option displays the settings that your finger ID device is currently set to. Enable Reader This option allows you to turn finger template verification on or off for all employees. Wit this option disabled, no employees will be asked to place their finger on the sensor when clocking in or out. When this option is selected, the following prompt appears: FINGER ID ENABLED? NOW: YES *ENTER* WHEN DONE YES NO Press the soft key under the ³YES´ or ³NO´ option, as desired. Require for Menus With this option enabled, finger template verification is required in order to access the clock¶s menu options. When this option is selected, the following prompt appears:
3/24/2008
20 of 24
Page 21
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
REQUIRE FP FOR ADMIN NOW: NO *ENTER* WHEN DONE YES NO Press the soft key under the ³YES´ or ³NO´ option, as desired.
External Devices Use this menu option to specify how your clock is to work with an external device (such as a bell/buzzer). The following options are available: 1. RELAY/DOOR CONTROL Relay/Door Control This option allows you to configure how your time clock relay functions with an external bell or buzzer, or the ³Door Security´ feature. Disable Relay Select this option to disable all functions performed by the time clock relay. No external device attached to the relay will operate with this option enabled. Enable Break Bell Select this option when you would like to use the clock relay in conjunction with an external bell, buzzer or other signal device. Enable Door Control Select this option when you would like to use the clock relay in conjunction with an external door locking mechanism, making it so that employees can gain access to a secured area upon the successful verification of the finger ID.
Display Options This menu allows you to configure how your clock display and keypad functions, and contains the following options: 1. US/EURO DATE 2. QUICK PUNCH 3. GLOBAL TIMEOUT 4. LCD BACKLIGHT US/Euro Date This option allows you to select whether you would like the date shown on the face of your clock to be displayed in US or European format. Note: US date format is ³MM/DD/YYYY.´ European date format is ³DD/MM/YYYY.´ Quick Punch With this feature enabled, employees do not have to press the final <ENTER> when clocking in or out.
3/24/2008
21 of 24
Page 22
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
Global Timeout This option allows you to specify the amount of time in seconds after which the clock will ³timeout´ to the Ready screen due to inactivity. The default setting is 30 seconds. LCD Backlight This option allows you to enable ³Power Save´ mode on the clock. With this option enabled, the backlight on the clock will only be lit when the clock is in use.
Punch Restrictions Use this option to restrict the information that your employees are able to specify with their punches. This menu has several options: 1. SUPERVISOR OVERRIDE 2. USE DEFAULT SCHEDULE Supervisor Override This option causes the ³Supervisor Required´ message to not be displayed at the clock on schedule errors (for employees not in the clock, use the ³Use Default Schedule´ option). Use Default Schedule This option allows you to specify whether an employee who is not in the time clock uses the default schedules stored in the clock memory, or requires a supervisor override in order to punch.
Personal Clock Interface The ³Personal´ menu options allow your employees to log into the clock and view various kinds of information. This menu contains the following options: 1. VALID PUNCH TIMES 2. ACCRUALS 3. DEPT, PERS. 4. FIND PUNCHES
Valid Punch Times Select this option to view the window of time during which you are allowed to punch at the time clock. This option is used when the administrator has uploaded schedules to the clock from the TimeForce database.
Accruals Select this option to view the number of ³Sick´ and ³Vacation´ hours that you currently have available. Note: This option is updated each time an upload from the TimeForce database is performed. The displayed hours totals will only be as current as the last upload.
3/24/2008
22 of 24
Page 23
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
Department and Personal This menu option displays your default department level. Any ³Employee Messages´ are also displayed on this screen.
Find Punches This option allows you to view your punches that are currently being stored by the time clock. Use the ³Scroll dn´ and ³Scroll up´ keys to scroll through punches. Note: Only punches that are currently stored in the memory of the time clock itself can be displayed. Punches that have been uploaded to the TimeForce database, or punches stored on a separate clock will not be displayed.
V800 / V850 Real Time Ethernet Clock The Real Time Ethernet Clock is used when you would like your clock to upload any stored data to the Clock Server automatically. This makes the process of manually connecting to your time clock for the purpose of downloading its stored punches unnecessary. The clock automatically uploads any stored data to the Clock Server immediately upon its entry into the clock. Manual data upload can also be selected. Note: The following setup instructions are specific to the Real Time options. All other ethernet setup steps are identical to the V800 Ethernet clock.
Setting the Push Server IP Before your clock will be able to successfully transfer punches, you must first enter the Push Server ID. 1. From the keypad of the clock, press the <MENU> button and enter your password. 2. Select 1 for ³ADMIN.´ 3. Select 3 for ³CLOCK SETUP.´ 4. Select 1 for ³COMMUNICATION.´ 5. Select 6 for ³OUTBOUND OPTIONS.´ 6. Select 5 for ³PUSH SERVER IP.´ 7. From the keypad of the clock, enter the IP address of the Push Server. Remember to use the period [ . ] key. Once the IP has been entered, press <ENTER>. The ³Port´ screen appears. 8. If a specific port number is required, enter it at the clock keypad. Press the upperright soft key to automatically populate this setting with the default of ³5402.´ Note: In most cases, the default setting will be used. 9. Press the <ENTER> key to save the changes that you have made. You can now exit the clock menu.
Set Dial Times The time clock allows you to specify how stored punches are uploaded to the database. 1. From the keypad of the clock, press the <MENU> button and enter your password. 3/24/2008
23 of 24
Page 24
Qqest Software Systems, Inc.
2. 3. 4. 5. 6.
Using the Model V800 Velocity Clock
Select 1 for ³ADMIN.´ Select 3 for ³CLOCK SETUP.´ Select 1 for ³COMMUNICATION.´ Select 6 for ³OUTBOUND OPTIONS.´ The ³Set Dial Times´ screen opens. The following options are available: •
•
Manual Only: With this option selected, the clock will not automatically upload its stored punches. The punches will remain in the clock until a manual upload is initiated. Note: See the section below for instructions on manually uploading your time clock. Real Time: With this option enabled, any punches entered at the clock will be immediately uploaded to the Clock Server.
You can now exit the clock menu by pressing <ENTER> repeatedly until you are brought back to the displayed time.
Initiating a Manual Upload The clock can be manually uploaded from the main ³Outbound Options´ menu. 1. From the keypad of the clock, press the <MENU> button and enter your password. 2. Select 1 for ³ADMIN.´ 3. Select 3 for ³CLOCK SETUP.´ 4. Select 1 for ³COMMUNICATION.´ 5. Select 6 for ³OUTBOUND OPTIONS.´ 6. Press 4 for ³UPLOAD DATA.´ The time clock initiates communication with the Clock Server and uploads its time and attendance data. Note: You can also manually upload data by pressing the following combination of keys at the clock keypad: <MENU>, < 9 > and then <ENTER>.