The text of a manual · part 2 of 3
Using the Model V800 Velocity Clock, pages 9 to 16
Pages 9 to 16 of 24
The original document is the PDF (287 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Qqest V800
Page 9
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
Creating a Clock Profile The time clock allows employees to access their current punch, schedule, accrual, and departmental information directly from the clock. This information is uploaded to the time clock using the ClockLink utility. A time clock profile must be created in TimeForce for each time clock. 1. Open the TimeForce software and log in as a user with administrative rights. 2. Click on the main ³Admin´ navigation tab at the top of the screen. 3. From the Clock Controls section of the screen, click on ³Clock Settings.´ The ³Clocks Setup´ screen opens. 4. This screen is divided into two columns. In the left-hand section of the screen, click on the link located to the right of the Clocks Setup header. The ³Clock Info´ screen opens to the right. 5. Enter the Clock ID. This ID is assigned at the time clock itself. The default clock ID is ³1.´ If you do not know your clock ID, see ³How Do I Find the Clock ID and Password?´ on page 1. 6. Select ³V800´ from the Model drop-down menu. 7. Enter a Description for this clock as you would like it to appear in the TimeForce and ClockLink programs. 8. If you would like to assign this clock to a group, make the desired selection from the Group Name drop-down menu. Note: Clock groups are created from the ³Edit Tables´ section of the TimeForce program. 9. Enter a clock Password. This password is assigned at the time clock itself. The default clock password is ³V800.´ See ³How Do I Find the Clock ID and Password?´ on page 1 for more information. 10. From the Connection Type drop-down menu, select ³Ethernet Clock,´ ³Serial Clock´ or ³Modem Clock.´ •
•
•
Ethernet Clock: Enter the IP Address where the clock can be reached. Remember to use periods. Not that this number is specific to your network setup. Qqest Software Systems cannot supply this setting. If the clock can only be reached using a specific port number, enter the appropriate setting into the Port Number field. Serial Clock: Select the Com Port that the clock is connected to from the drop-down menu. Select ³Auto Detect´ to have the system automatically determine which port the clock is connected to. Note: The clock will only communicate on com ports 1 - 4. Serial clocks can also be connected using a Keyspan USB adapter. Modem Clock: In the Phone Number field, enter the phone number of the line that the clock is connected to. Enter the number exactly as you would dial it into a telephone, including any necessary area code or extension numbers. Do not use dashes or brackets. For example, a phone number of (800) 555-4855 would be entered as ³18005554855.´
11. When using an external bell, buzzer or other signal device, the Relay Events section of the screen allows you to schedule the times at which the device will go off. See ³Relay Events´ on page 10 for more information.
3/24/2008
9 of 24
Page 10
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
12. Enter any desired Notes about this time clock in the provided text-entry field. There is a maximum of 250 characters. 13. The clock allows you to restrict which employees are allowed to punch in and out, but before these restrictions can be made, the clock profile must be added to the system. Click on the [ADD] icon in the lower right-hand corner of the screen to create the time clock profile. The Employees at Clock header appears. See ³Employees at Clock´ on page 11 for more information on assigning specific employees to the clock. 14. When you have finished entering clock information, click on the [ADD] icon to add the time clock profile.
Customizing Time Clock Information Multiple levels of information can be uploaded to the time clock from the TimeForce database.
Relay Events Qqest time clocks come with an optional feature called ³Relay Events.´ This feature allows you to connect an external bell, buzzer or other signal device to the time clock and program specific times of the day for the signal to go off, usually indicating scheduled start, stop or break times. Each clock can handle up to 32 relay events. Although all Qqest time clocks can have relay events uploaded to them, the physical time clock relay itself will only be installed if you have purchased the Relay Events premium option. Relay Events are assigned to the clock in TimeForce. Use the following instructions to assign relay events to your time clock profiles. 1. Open the TimeForce software and log in as an administrator-level user. 2. Click on the main ³Admin´ navigation tab at the top of the screen. 3. From the Clock Controls section of the screen, click on the ³Clock Settings´ link. The ³Clocks Setup´ screen opens. 4. The left-hand section of the screen allows you to search for existing clock profiles based on the clock group that they are assigned to. Make the desired selection from the Group Name drop-down menu. Select ³All´ to bring up all time clock profiles. 5. Click on the [DISPLAY] icon. The found time clock profiles are displayed under the Clocks header. 6. In the Clock ID column, click on the ID of the time clock that you would like to assign relay events to. The ³Clocks Info´ screen opens to the right. 7. In the ³Clock Info´ section of the screen, ensure that the Upload Relay Events option is selected. With this option enabled, ³Relay Events´ appears below the ³Employees at Clock´ section of the screen. 8. Click on the icon located to the right of the Relay Events header to show relay events. 9. To create a new relay event, click on the [ADD] icon.
3/24/2008
10 of 24
Page 11
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
10. In the Time column, enter the time of day that this event is to be activated. The time must be entered in 24-hour format. 11. In the Duration column, enter the number of seconds that you want the bell or buzzer to sound for when the event is activated. 12. When the relay event occurs, it can either pulse for its duration or it can sound continuously. With Pulse selected, the bell or buzzer sounds as a series of pulses (on... off... on... off... on... off) for the duration of the event. If not selected, the bell or buzzer sounds continuously for the duration of the event. 13. Put a check mark in the box for each day of the week on which you would like this event to occur. 14. Click on the [SAVE] icon to save the relay event. The clock can handle up to 32 relay events. To remove an event from the clock profile, click on the icon.
Employees at Clock The time clock gives you the option of restricting the employees who are allowed to punch in and out. If an employee who is not assigned to the time clock attempts to punch, they will receive an error stating that they are not assigned to the clock and that a supervisor override is required. A supervisor can then enter their clock password and allow the punch, if desired. By default, all employees are allowed to punch at the time clock. Use the following instructions to restrict employees. 1. Open the TimeForce software and log in as an administrator-level user. 2. Click on the main ³Admin´ navigation tab at the top of the screen. 3. From the Clock Controls section of the screen, click on ³Clock Settings.´ The ³Clocks Setup´ screen opens. 4. The left-hand section of the screen allows you to search for existing clock profiles based on the clock group that they are assigned to. Make the desired selection from the Group Name drop-down menu. Select ³All´ to bring up all time clock profiles. 5. Click on the [DISPLAY] icon. The found clock profiles are displayed under the Clocks header. 6. In the Clock ID column, click on the ID of the time clock that you would like to restrict employees for. The ³Clock Info´ screen appears to the right. The ³Employees at Clock´ setup is located below the Clock ID section of the screen. 7. Remove the check mark from the Send All employees to the clock option. The ³Unassigned Employees´ and ³Assigned Employees´ boxes appear. 8. All employees appear in the ³Unassigned´ box. To filter the list of displayed employees by the department that they are assigned to, make the desired selection from the drop-down menu at the top of the screen. Click on the icon to select the department from a map.
3/24/2008
11 of 24
Page 12
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
9. Highlight the employees that you would like to be allowed to punch at this clock (hold down the {CTRL} key on your keyboard to select multiple employees). 10. Click on the icon. The selected employees are moved to the ³Assigned Employees´ box. 11. To unassign employees, highlight the desired names in the ³Assigned Employees´ box and click on the icon. The selected employees are moved to the ³Unassigned Employees´ box. 12. Click on the [UPDATE] icon located in the lower right-hand corner of the screen to save the changes that you have made.
Editing and Deleting Existing Clock Profiles Time clock profiles are displayed in the ³Clock Settings´ section of the TimeForce program. 1. Open the TimeForce program and log in as an administrator-level user. 2. Click on the main ³Admin´ navigation tab at the top of the screen. 3. From the Clock Controls section of the screen, click on ³Clock Settings.´ The ³Clocks Setup´ screen opens. This screen is divided into two columns. The righthand section of the screen allows you to manage existing time clock profiles. 4. If you would like to view clock profiles belonging to a specific clock group only, make the desired selection from the Group Name drop-down menu. Select ³All´ to display all time clock profiles. 5. The Sort by fields allow you to select how the displayed list of clock profiles are sorted. 6. Click on the [DISPLAY] icon to view time clock profiles. Clock profiles are displayed under the Clocks section of the screen. 7. The following information is displayed for each profile. • • • • • •
Clock ID: This is the ID of the displayed time clock. The setting in this field is a link. Click on the link to bring up the ³Clock Info´ for this profile in the right-hand section of the screen. Clock Type: This column displays the type of clock (as in ³V800,´ ³V850,´ etc.). Description: This is the description that was inserted when the clock profile was created. Group: If the time clock is assigned to a clock group, this field displays the name of the group that the clock is assigned to. Active: Shows whether or not the clock profile is set to a status of ³active.´ Click on the icon to remove a clock profile from the system.
8. To edit a time clock profile, click on the link for the appropriate clock located in the Clock ID section of the screen. The ³Clock Info´ screen opens to the right. Review and modify the data as desired. •
3/24/2008
Click on the [UPDATE] icon to save any changes that you have made to the time clock profile.
12 of 24
Page 13
Qqest Software Systems, Inc.
•
• •
Using the Model V800 Velocity Clock
Click on the [DEACTIVATE] icon to deactivate a clock profile. The clock will not be accessible through the ClockLink utility, but the profile information will be retained in this section of the TimeForce program. Click on the [ACTIVATE] icon to re-activate an inactive clock profile. To remove a clock profile from the system, click on the [DELETE] icon in the ³Clock Info´ section of the screen or on the icon located next to the displayed profile in the search results section of the screen. Click on the [COPY] icon to make a duplicate copy of the current clock profile.
Enrolling Finger ID Templates Before your employees will be able to enter punches at the V800, their finger IDs must first be enrolled at the clock. 1. Press the <MENU> button on the time clock keypad. Select 1 for ³Admin.´ The following message appears: ENTER YOUR CARD # 2. Enter the card number of a user that has access to the ³Admin´ clock features and press the <ENTER> key on the clock keypad. Note: The default administrator username is ³8888.´ The following message appears: ENTER PIN: 3. Enter the password for the given card number and press the <ENTER> key on the clock keypad. Note: The default administrator password is ³1111.´ 4. The main menu appears with several options. Press 2 for ³Manage Finger IDs.´ 5. Press 1 for ³New Finger ID.´ 6. The prompt ENTER CARD NUMBER appears. Enter the card number or keypad entry number that you assigned to this employee in the TimeForce software and press <ENTER>. 7. A prompt appears that reads: READING FINGER ID PUT FINGER ON SENSOR 8. Have the employee whom you are enrolling place his or her finger in the template reader. Usually the index finger is used, though the middle and ring fingers can also produce good results. To ensure correct placement, the employee should place the first joint of the finger against the raised ridge at the base of the reader screen, and place the fingertip firmly against the screen. 9. Once the clock has read the finger, the following message appears: QUALITY: [X]/100 OK TO ACCEPT? YES NO
3/24/2008
13 of 24
Page 14
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
This message denotes the general quality of the template read. You want the ³QUALITY´ to be as high as possible. Press the soft key under ³YES´ to accept the template read. Press the button below ³NO´ to have the clock read the template again. 10. If the ³QUALITY´ read is too low, the following message may appear: QUALITY: [X]/100 QUALITY LOW RETRY ACCEPT If you get this message, you can have the employee moisten his or her finger slightly. Moisture helps the reader collect a high quality reading of the finger.
Deleting Existing Finger ID Records To delete a finger ID record, from the ³Manage Finger IDs´ menu select 2 for ³Delete.´ The clock asks you to enter the card number of the employee whose templates are to be deleted. Type in the card number and press <ENTER>. The following message appears: PLEASE CONFIRM ± OK TO DELETE TEMPLATES FOR CARD [X]? YES NO Press the soft key under the ³YES´ option to delete this employee¶s stored finger ID templates.
Setting the Global Security Level Use the following instructions to change the global security level. 1. Press the <MENU> button on the keypad, select the ³Admin´ menu option, and enter your card number and password. 2. Press 2 for ³Manage Finger IDs.´ 3. Press 4 for ³Global Security.´ The following message appears: GLOBAL SECURITY NOW: 3 1=MINIMUM, 5=MAXIMUM NEW SECURITY: The default global security level is 5. Type in the new security level and press the <ENTER> key.
Collecting Data Punching in and out is very simple with the V800. Within the TimeForce software, each employee is assigned a ³Card Number.´ This number corresponds with the number assigned to the employee¶s finger template stored in the time clock itself. If the V800 is ready to accept punches, the word ³Ready´ appears in the display panel with the date and time.
3/24/2008
14 of 24
Page 15
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
Time & Attendance Punches Use the following instructions to enter basic time and attendance punches at the clock (with no job, task or department information). 1. Check to see that the clock display reads ³Ready´ with the date and time displayed at the top of the screen. 2. Enter your card number at the clock keypad and press <ENTER>. The display panel shows the card number and reads: CARD #[X] READING FINGER ID PUT FINGER ON SENSOR 3. Place your finger on the template reader. To ensure correct placement, the finger should be placed with the first joint of the finger against the raised ridge at the base of the reader screen, and with the fingertip pressed firmly against the screen. Once your finger ID has been verified, the following message is displayed: ID [X] CHOOSE IN/OUT ENTER = ACCEPT 4. Press the <ENTER> key to complete the time & attendance entry. Note: The <ENTER> key should always be pressed when completing a punch at the time clock, unless the ³Quick Punch´ system option is enabled.
Other Punch Options After the ID number has been specified, press <ENTER> to enter the punch and have the software determine whether it is an in or out punch. If you wish to assign the punch a type, press the <IN>, <MEAL>, <BREAK>, or <OUT> buttons, then press <ENTER>. You can press the buttons in combination to specify a punch type; for example, <MEAL> plus <OUT>, or <BREAK> plus <IN>. If you make a mistake, such as accidentally pressing <IN> rather than <OUT>, simply press the correct button and the display shows the new punch type you¶ve specified. When the punch type is correct, press <ENTER>. Unless you have enabled the clock¶s Quick Punch feature, you should always press <ENTER> to complete a punch entry at the V800. Note: The <MEAL> and <BREAK> keys on the clock keypad can be enabled and disabled from the clock menu. See ³Keypad Behavior´ on page 19 for more information.
Additional Clock Features A V800 clock includes many advanced features. The following is a brief description of the features offered by this clock. Press the <MENU> button to see additional options. When you do so, a prompt appears asking you to enter your password. Type in your password and press <ENTER>.
3/24/2008
15 of 24
Page 16
Qqest Software Systems, Inc.
Using the Model V800 Velocity Clock
Note: When you purchase your clock, the default administrator password is set as ³8888.´ The default supervisor password is set as ³1111.´ Enter the default administrator password the first time that you use the clock. Once you have accessed the main menu, you can select the Passwords option and reset the defaults to the passwords of your choice.
Main Menu When you enter your password, the Main Menu appears with the following options: 1. ADMIN 2. PERSONAL 3. RESTART CLOCK 4. UPLOAD DATA 5. PRODUCTION/TEST Note: See ³Personal Clock Interface´ on page 22 for instructions on ³Personal´ clock options. The ³Upload Data´ option is only available with the Cellular Modem clock. The ³Production/Test´ option is for use by Qqest Software Systems, and is only accessible with a password. Select 1 for ³ADMIN.´ The MAIN ADMIN MENU appears, with the following options: Note: Menus are displayed using vertical scrolling. Three options are visible at a time. Use the ³Scroll dn´ and ³Scroll up´ keys (also the <IN> and <OUT> keys) to view additional menu options. 1. SET DATE/TIME 2. MANAGE FINGER IDS 3. CLOCK SETUP 4. REPORTS 5. MANAGE MEMORY
Set Date/Time This option is used to manually set the date and time on your time clock. The date and time can also be uploaded from your computer¶s system date and time using the ClockLink utility. When this option is selected, the SET DATE/TIME screen appears. Time To set the time on the clock, select the ³TIME´ option either by pressing the number 1 on the clock keypad, or by using the scroll keys to highlight the appropriate option and pressing the <ENTER> key. In 24-hour format, enter the appropriate time in the following format: ³HH:MM:SS´ and press the <ENTER> key. Date To specify the date on the clock select the ³DATE´ option by either pressing the number 2 on the clock keypad, or by using the scroll keys to highlight the option and pressing the <ENTER> key. Using the clock keypad, enter the appropriate date in the following format: ³MM/DD/YYYY´ and press the <ENTER> key. 3/24/2008
16 of 24