Page 187

Chapter 5: Settings Regional Settings

• Tap on Change to User mode. You’ll need to reset the EP10 so that the changes you specified can take effect.

•

5.11.19

Tap on Yes to reset the EP10 and activate your changes.

Regional Settings To display the Regional Settings screen, tap on Start>Settings, and then tap on the System icon followed by the Regional Settings icon.

Psion EP10 Hand-Held Computer User Manual

173

Page 188

Chapter 5: Settings Remove Programs

• Tap on the drop-down menu to choose your language and region. Once you’ve selected a language and region, you may need to adjust the way numbers, currency, the time and the date appear in your EP10. •

5.11.20

Tap on the tab associated with each of the items, and choose how each item should be displayed on your EP10.

Remove Programs •

Tap on Start>Settings. Tap on the System icon followed by the Remove Program icon.

Tapping on the Remove Programs icon displays a screen listing the programs that can be removed from your unit. •

5.11.21

To remove a program, highlight it and then tap on the Remove button.

Scanner Settings The Scanners icon in the Settings menu provides access to dialog boxes in which you can tailor imager options.

174

Psion EP10 Hand-Held Computer User Manual

Page 189

Chapter 5: Settings Scanner Settings

Note: For details about setting up your imager, refer to Appendix C: “Imagers Applet”.

•

5.11.21.1

Tap on Start>Settings, and then tap on the System followed by the Scanners icon.

Options Tab The Options tab allows you to tailor the double-click parameters, the display options, and the data handling options associated with your scanner.

5.11.21.1.1 Double Click Parameters Click Time (msec) This parameter controls the maximum gap time (in milliseconds) for a double-click. If the time between the first and second clicks of the scanner trigger is within this time, it is considered a double-click. The allowable range is 0 to 1000. A value of zero disables this feature. A double-click produces different results depending on whether or not a value is assigned in the “Click Data” parameter. When a value is not assigned for the “Click Data”, double-clicking the scanner trigger overrides the target dot delay set in the “Dot Time” parameter and initiates a normal scan sweep. If a value is assigned for the “Click Data” parameter, double-clicking the scanner trigger inserts the “Click Data” value rather than initiating a scan.

Psion EP10 Hand-Held Computer User Manual

175

Page 190

Chapter 5: Settings Scanner Settings

Click Data For both integrated and external scanners, this parameter determines which character is sent to the application installed in your EP10 following a double-click. A dialog box appears, asking that you press the key you want to insert. The ASCII/Unicode key value of the keypress is displayed.

5.11.21.1.2 Display Parameters Scan Result When this parameter is enabled, the type of bar code and the result of the scan appear on the screen. Note that this information is only displayed after a successful decode and is visible only while the scanner button is pressed. When the button is released, this information is cleared from the screen. Scan Indicator When this parameter is enabled, the laser warning logo appears on the display whenever the scanner is activated. Scan Result Time (msec) The value assigned to the “Scan Result Time (sec)” parameter determines how long the scan results of a successful scan are displayed on the screen. Time is measured in seconds, and a value of “0” (zero) disables the parameter. When you choose this option, a dialog box appears where you can enter a value.

Note: To remove the scan result from the screen before the “Result Time” has expired, point the scanner away from the bar code and press the trigger.

Good Scan Beep and Bad Scan Beep These parameters determine whether or not the EP10 emits an audible scanner ‘beep’ when a good (successful) scan or a bad (unsuccessful) scan is performed, the number of vibrates, the duration of the vibrate, and so on. Set these parameters to tailor the behaviour of this parameter. Multiple Beep Tones This parameter determines whether or not multiple beeps will be allowed. Good and Bad Scan Vibrates These parameters determine whether or not the EP10 will vibrate (rather than beep) when a good (successful) scan or a bad (unsuccessful) scan is performed. Set these parameters to either on to enable the beeper or off to disable it. You can further refine how you want the vibrations to behave, specifying the following: Number of Vibrates, Duration of Vibrate (in milliseconds), and Pause between Vibrates (in milliseconds). Soft Scan Timeout This parameter is used by the SDK “Scan” function (soft-scan: starting a scan session via the SDK function, instead of a physical user trigger press). The value assigned to this parameter determines the soft-scan timeout from 1 to 10 sec. (default is 3 sec.). Scan Log File If this parameter is enabled, the input bar code and the modified/translated output bar code are logged in the file \Flash Disk\ScanLog.txt. Keep in mind that if the “Scan Log File” is enabled, there is a slight performance effect when performing multiple scans since the log file is written to persistent storage.

5.11.21.1.3 Data Handling This option provides two data handling options: Codepage and Data Transmission. Codepage: Tapping on this option displays a window in which you can define the code page your EP10 will use to display data – Default Local ASCII or ISO-8859-1 Latin 1.

176

Psion EP10 Hand-Held Computer User Manual

Page 191

Chapter 5: Settings Scanner Settings

If you choose Default Local ASCII, the code page of the local OS is used. For example, if the local OS uses double-byte Chinese characters, choosing this option will filter data through the local ASCII of that OS and display it accurately, in this example, using double-byte characters. If you choose ISO-8859-1 Latin 1, data will be displayed according to the character mapping of this Latin 1 code page, ignoring the local OS code page. Data Transmission

If Paste data is enabled (highlighted), the barcode output is copied to the system clipboard and then automatically pasted to an application. If Wedge data is enabled, each character that composes the barcode data is turned into a keyboard sequence that is transmitted to the cursor location of the current application – that is, to the application, it looks like the barcode data was typed on the keyboard.

Note: The default Paste data option is a faster method of data transmission.

5.11.21.2 Translations Tab The Translations tab allows you to define up to 10 cases, each consisting of up to 10 rules in sequential order. Only one case will be applied to a bar code and a case will only be applied if all rules specified in the case are successful – if a rule within a case fails, the entire case fails.

Psion EP10 Hand-Held Computer User Manual

177

Page 192

Chapter 5: Settings Scanner Settings

•

In the Translations tab, double-tap on a Case # to create rules.

•

Tap on the No rule drop-down menu to display the rules.

When you choose a rule, an associated screen is displayed in which you can define the rule.

178

Psion EP10 Hand-Held Computer User Manual

Page 193

Chapter 5: Settings Scanner Settings

5.11.21.2.1 Case Rules The case rules are defined as follows: • • • • • • •

No rule – ignored. Match at index – matches the match string at a specified index. Match and replace at index – matches the match string at a specified index and replaces/changes it. Replace at index – replaces/changes unspecified data in a given range. Add barcode prefix/suffix – adds a global prefix or suffix. Verify barcode size – verifies the bar code size. This rule should generally be assigned first, before creating subsequent rules. Search and replace – replaces all instances of the match string. (Note that this rule cannot fail.)

Important: Keep in mind that the effects of previously applied rules must be taken into account when creating subsequent rules. For example, if the bar code size is important, it should be checked before any rules that might change the size are applied.

The information about the status of each case/rule is displayed in the scan log file (see “Scan Log File” on page 176) when enabled. This is useful if a case fails, and you are trying to determine why a rule is failing.

5.11.21.3 Ports Tab - Port Replicator Port A (COM5), Port B (COM6), Port C (COM7)

Psion EP10 Hand-Held Computer User Manual

179

Page 194

Chapter 5: Settings Scanner Settings

Enabled This parameter must be set to on in order for EP10 to recognize the device connected to the Port Replicator 9-pin (COM5). Power (COM6 only) Pin 9 on EP10 COM6 is reserved for 5V power out and is defaulted to OFF. This parameter must be set to on to enable power to a Snap Module or Vehicle cradle. Baud Double-tapping on this parameter displays a pop-up window in which you can choose an appropriate rate of data transfer. Figure 5.1

Port Baud Rates

Data Bits This parameter determines the number of data bits included in each asynchronous data byte. Most devices use 8-bit data bytes. Double-tapping on this option displays a pop-up window in which you can choose either 7 or 8 data bits. Parity This parameter determines the type of parity checking used on the data going through the port replicator port. Double-tapping on this option displays a pop-up window in which you can choose the appropriate parity.

180

Psion EP10 Hand-Held Computer User Manual

Page 195

Chapter 5: Settings Screen

Stop Bits This parameter specifies the number of stop bits, 1, 1.5 or 2, used for asynchronous communication. Trigger On Sequence and Trigger Off Sequence If a SICK scanner connected to an EP10 port requires a serial stream of data bytes to trigger the scanner on and another to trigger the scanner off, the Trigger On Sequence and Trigger Off Sequence parameters allow you to define these serial streams.

Double-tapping on Trigger On Sequence or Trigger Off Sequence displays a screen with a hex array of 10 elements. These parameters work in conjunction with Manage Triggers sending on and off data streams to the trigger module you assigned. For example, suppose you launch Manage Triggers and choose Decoded Scanner as the ‘module to trigger’. Next, you assign a ‘trigger key’, for this example, . (period). To define the serial stream of data bytes to control the on and off function of the ‘trigger key’, enter a hex value in the Trigger On Sequence and the Trigger Off Sequence fields. When you press the trigger key, the Trigger On Sequence is sent and when you release the trigger key, the Trigger Off Sequence is sent, turning the trigger key on and off.

5.11.22

Screen •

Tap Start>Settings. Tap on the System icon, and then tap on the Screen icon.

This icon allows you to align (calibrate) your touchscreen, turn ClearType on and off and adjust the size of the text displayed on the EP10 screen.

Psion EP10 Hand-Held Computer User Manual

181

Page 196

Chapter 5: Settings Screen Rotation

Important: Refer to “Aligning (Calibrating) the Touchscreen” on page 24.

5.11.23

Screen Rotation •

Tap Start>Settings. Tap on the System icon, and then tap on the Screen Rotation icon.

This screen allows you to determine how your EP10 screen will behave depending on how the unit is rotated. All orientations: screen rotates to portrait or landscape to match the orientation of the actual EP10. Portrait: screen does not rotate regardless of the orientation of the EP10. The screen will always be displayed as portrait. Landscape: screen does not rotate regardless of the orientation of the EP10. The screen will always be displayed as landscape Enable auto screen rotation is enabled by default. If you prefer to set screen rotation manually, you can disable this option. A Configure button is displayed on the screen.

Tapping on the Configure button displays the Screen dialog box.

182

Psion EP10 Hand-Held Computer User Manual