The text of a manual · part 20 of 35
EP10 Hand-Held Computer User Manual (Windows Embedded Hand-Held 6.5): Settings, pages 147 to 156
Pages 147 to 156 of 282, from EP10 Hand-Held Computer User Manual (Windows Embedded Hand-Held 6.5)
The original document is the PDF (14 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Psion EP10 and Motorola EP10
Page 147
Chapter 5: Settings Wireless Manager
5.8.10
Wireless Manager The Wireless Manager icon acts as a connection manager, providing access to all network connection types. •
Tap on Start>Settings>Connections folder icon. Tap on the Wireless Manager icon.
This screen is used to switch the wireless network connection on and off. this screen also provides access to the setup screens for each wireless connection. • To turn connections on and off, tap on the item(s) in the list. • To turn off all wireless connections, tap on All. The Menu softkey at the bottom of the screen provides a shortcut to the setup screens for each of the options listed in the Wireless Manager screen.
5.9
Personal Folder •
Tap on Start>Settings>Personal icon.
Psion EP10 Hand-Held Computer User Manual
133
Page 148
Chapter 5: Settings App Launch Keys
5.9.1
App Launch Keys
This icon allows you to map a key to an application so that you can then launch the application from a single key-press.
To assign an application key: •
134
Tap the Add button.
Psion EP10 Hand-Held Computer User Manual
Page 149
Chapter 5: Settings Buttons
•
Press the key you want to use to launch an application. (If an unsupported key is pressed, a message appears on this screen letting you know.) The cursor moves to the App field and a new screen is displayed where you can choose the application to which you want to assign the application key. If you need to, you can Browse through the information in your hand-held until you locate the application you want to launch.
• Once you’ve selected the file you want to map, tap on OK. The cursor moves to the Data field. You can use this field if you need to assign special parameters to your application launch key. If you don’t want to assign any parameters, you can leave the Data field blank. If, for example, you want to assign an application launch key to launch the Word Mobile application, you can leave this field blank. If you want to assign an application launch key that will open a specific document in the Word Mobile application, you need to browse to and choose that document while the cursor is in the Data field. •
Tap on OK.
•
If you need to Edit, Remove or Add another App Launch Key, you can do it from this final screen. Otherwise, tap on OK to save your Application Launch Key. To launch the application you chose, press the application key you assigned.
•
5.9.2
Buttons A number of apps are included under this icon. •
Tap on the Start>Settings>Personal>Buttons icon to display the apps.
Psion EP10 Hand-Held Computer User Manual
135
Page 150
Chapter 5: Settings Buttons
5.9.2.1
Program Buttons Tab In the Program Buttons tab, you can customize the program hardware buttons to open your most used programs. • •
5.9.2.2
Under Select a button, tap on the button to which you want to assign a program. Choose a program from the Assign drop-down menu.
Up/Down Control Tab
•
Tap on Start>Settings>Personal>Buttons icon to display this screen. Scroll to the Up/Down Control tab. Sliding the Delay before first repeat bar to the left decreases the delay between key repeats while sliding the bar to the right increases the repeat delay time. Sliding the Repeat rate bar to the left slows the rate at which an [Up/Down] button repeats when pressed. Sliding the bar to the right increases the key repeat rate.
136
Psion EP10 Hand-Held Computer User Manual
Page 151
Chapter 5: Settings Buttons
5.9.2.3
OneShots
The options in this tab allow you to determine how modifier keys on your EP10 behave. For each modifier key – [ALT], [SHIFT], [CTRL], [SYM] and [BLUE/FN] – you have the following options in the drop-down menu: Lock, OneShot, and OneShot/Lock.
Important: Once you’ve assigned a OneShot mode to a modifier key, you need to tap on the OK button at the top of the tab to activate your selection.
Lock If you choose Lock from the drop-down menu, pressing a modifier key once locks it ‘on’ until you press the modifier key a second time to unlock or turn it off. OneShot If you choose OneShot, the modifier key remains active only until the next key is pressed. OneShot/Lock OneShot/Lock allows you to combine these functions. When you choose this option and you press the modifier key once, it remains active only until the next key is pressed. If you press the modifier key twice, it is locked ‘on’, remaining active until the modifier key is pressed a third time to turn it ‘off’.
5.9.2.4
Macro Keys
Psion EP10 Hand-Held Computer User Manual
137
Page 152
Chapter 5: Settings Buttons
Macro keys can be programmed to replace frequently used keystrokes, along with the function of executable keys including [ENTER], [BKSP] and [DEL] ([BLUE/FN]-[BKSP]), function keys, and arrow keys. Recording and Saving a Macro You can program up to 15 macro keys. •
In the Macro list on the left side of the screen, highlight a macro key number – for example, 1. Tap on the Record button in the softkey bar at the bottom of the screen. A Record Macro screen is displayed.
•
Key in the macro sequence you want to assign to the Macro. You can type text and numbers, and you can program the function of special keys into a macro. • When you’ve finished recording your macro sequence, tap on the Stop Recording button. A new screen displays the macro sequence you created. • •
Tap on the Save button to save your macro. Your macro key sequence is listed in the Macro screen. Tap on OK to save your macro key assignment.
Executing a Macro To execute a Macro, you must use Scancode Remapping to map the macro to a specific key. Note: Refer to “Scancode Remapping” on page 140.
Deleting a Macro • In the Macros tab, highlight the macro number you want to delete. • Tap on the Delete button at the bottom of the screen.
5.9.2.5
Unicode Mapping •
138
Tap on the Unicode Mapping tab to display this screen.
Psion EP10 Hand-Held Computer User Manual
Page 153
Chapter 5: Settings Buttons
The Unicode Mapping tab is used to map combinations of virtual key values and [CTRL] and [SHIFT] states to Unicode™ values. This tab shows the configured Unicode character along with the Unicode value. For example, “a (U+0061)” indicates that the character “a” is represented by the Unicode value “0061”, and so on. Keep in mind that Unicode configurations are represented as hexadecimal rather than decimal values. All user-defined Unicode mappings are listed in the Unicode Mapping tab in order of virtual key value, and then by order of the shift state. If a Unicode mapping is not listed, the Unicode mapping is mapped to the default Unicode value. Adding and Changing Unicode Values
Note: Changes to Unicode mappings are not saved until you exit the Unicode Mapping tab by tapping on [OK].
•
Tap on the Add/Edit button.
• •
Highlight a value in the Unicode mapping list. Position the cursor in the Unicode Mapping field, and type a Unicode value for the highlighted key.
Note: To add a shifted state – [SHIFT] and/or [CTRL], tap on the checkbox next to ‘SHIFT Pressed’ and/or ‘CTRL Pressed’.
Psion EP10 Hand-Held Computer User Manual
139
Page 154
Chapter 5: Settings Buttons
Removing Unicode Values • In the Unicode Mapping tab, highlight the item you want to delete, and tap on the Remove button.
5.9.2.6
Scancode Remapping A scancode is a number that is associated with a physical key on a keyboard. Every key has a unique scancode that is mapped to a virtual key, a function, or a macro. Scancode Remapping allows you to change the functionality of any key on the keyboard. A key can be remapped to send a virtual key (e.g. VK_F represents the ‘F’ key; VK_RETURN represents the [ENTER] key, etc.), perform a function (e.g. turn the scanner on, change volume/contrast, etc.) or run a macro. There are three different tables of scancode mappings: the Normal table, the FN table and the SYM table. The Normal table defines unmodified key presses; the FN table defines key presses that occur when the [FN/BLUE] modifier is on; the SYM table defines key presses that occur when the [SYM] modifier is on. The default mappings of these scancodes can be overwritten for each of these three tables using Scancode Remapping.
The first column in the Scancode Remapping tab displays the scancodes in hexadecimal. If the scancode is remapped to a virtual key, that virtual key is displayed in the next column labelled ‘V-Key’. A virtual key that is ‘Shifted’ or ‘Unshifted’ is displayed in the third column labelled ‘Function’. If the scancode is remapped to a function or a macro, the first and second columns remain blank while the third column contains the function name or macro key number (e.g., Macro 2). Adding a Remap To add a new remapping: • Tap the Add button at the bottom of the dialog box. The Remap Scancode dialog box is displayed.
140
Psion EP10 Hand-Held Computer User Manual
Page 155
Chapter 5: Settings Buttons
•
Type the scancode in hexadecimal in the field labelled Scancode.
Note: The Label field displays the default function of the scancode you are remapping.
Virtual Key, Function and Macro The radio buttons at the bottom of the dialog box allow you to define to what the scancode will be remapped to: Virtual Key, Function or Macro. When Virtual Key is selected, you can choose to force [SHIFT] to be on or off when the virtual key is sent. If No Force is selected, the shift state is dependent on whether the shift state is on or off at the time the virtual key is sent. When Function is selected, a list of valid functions appears in the dialog box. When Macro is selected, the macro keys available on your unit are listed in the dialog box. • •
Choose Virtual Key>Function or Macro. Choose a function from the Function list, and tap on OK.
Editing a Scancode Remap • • •
In the Scancode Remapping tab, tap on the remap you want to edit. Tap on the Edit button, and make the appropriate changes. Tap on OK to save your changes.
Removing a Remap • •
5.9.2.7
In the Scancode Remapping tab, highlight the scancode you want to delete, and tap on the Menu button, and choose Remove. Tap on OK.
Auto Lock Tab The Auto Lock tab allows you to choose the auto lock behaviour of the EP10 based on the options selected in this screen.
Psion EP10 Hand-Held Computer User Manual
141
Page 156
Chapter 5: Settings Phone
• Tap in the checkbox next to the behaviours during which you want the Auto Lock applet to take effect. If you enable Lock when device is turned on, turn your unit off, and then back on again, the keyboard and screen will be locked. A lock icon is displayed in the navigation bar at the top of the screen when the unit is locked. •
5.10
To unlock the unit, you will need to type the Unlock key sequence you’ve selected from the Unlock key sequence drop-down menu – for example, press [SYM], then [FN], and finally [Bksp].
Phone •
Tap on Start>Settings>Personal>Phone to display options to help you tailor the EP10 phone features.
Important: The phone features are described under “The Phone” on page 49.
5.11
System Folder •
5.11.1
Tap on Start>Settings>System icon to display a group of system apps.
About Tapping on Start>Settings>System tab, and then the About icon displays a grouping of tabs that provide device information.
142
Psion EP10 Hand-Held Computer User Manual