Page 65
Chapter 2: Assembly And Basic Operation Scanning Techniques • • •
Check the bar code to make sure it is not damaged. Try scanning a different bar code to verify that the problem is not with the bar code. Check that the bar code is within the proper range (see page 239). Does the terminal display the warning without scanning? This suggests a hardware problem in the 7035.
The terminal can be configured to enable a function (such as <ENTER>) by pressing the trigger twice within a time period which is measured in milliseconds. See “Click Time” on page 135 for more details. This function is independent of the aiming dot override described earlier in this section, under “Operation Of The Integrated Scanner” on page 37 and only applies after a successful scan.
2.10.3 Scanning Techniques The Scanner Angle •
Hold the scanner at an angle. Do not hold it perpendicular to the bar code.
Do not hold the scanner directly over the bar code. In this position, light can reflect back into the scanner’s exit window and prevent a successful decode.
Scan Symbol Variations • • •
Scan the entire symbol. The scan beam must cross every bar and space on the bar code, including the margins on either end of the symbol. Hold the scanner farther away for larger bar codes. Hold the scanner closer for bar codes with bars that are close together.
2.11 Infrared (IrDA) Port – 7035 Only The IrDA port is the small red window at the top of the 7035. This port can transmit an infrared signal to printer equipped with an IrDA adaptor. The maximum distance between IrDA devices is 18 inches. Important:
The IrDA port is connected to the COM1 serial port UART. A serial peripheral connected to COM1 cannot be used while the IrDA port is active.
Teklogix 7035, 8255 & 8260 Terminals User Manual
39
Page 66
Chapter 2: Assembly And Basic Operation Low Temperature, Freezer and Outdoor Terminals
2.12 Low Temperature, Freezer and Outdoor Terminals Teklogix has developed a range of hand-held and vehicle-mount terminals that can withstand low temperatures, outdoor use, and/or freezer applications. Each terminal’s capabilities along with a list of operating guidelines is provided in this document.
2.12.1 Hand-Held Terminals 7035 Freezer Terminals Important:
• • •
A 7035 freezer terminal will cold-start if left in a freezer; HOWEVER, you may experience long delays while the internal heater warms the liquid crystal display to a temperature that can provide an acceptable refresh rate. In cases where the 7035 freezer terminal is left to freeze in an environment below -20˚ C (-4˚ F), and the battery has less than a 30% charge remaining, the terminal may not power up properly. IN ORDER TO AVOID THESE ISSUES, we recommend that the 7035 freezer terminal be stored and powered up at temperatures above 0˚ C (32˚ F). For use in temperatures ranging from -30˚ C to 50˚ C (-22˚ F to 122˚ F). Water-sealed to IP 54 to withstand rain and condensing environments. 7035 terminals must be used with a rubber boot or vinyl protective carrying case to enhance drop performance below 0˚ C (32˚ F).
2.12.2 Vehicle-Mount Terminals 8255/8260 Standard Temp., Low Temp., and Freezer vehicle-mount terminals are sealed against dust and high-pressure water jets to the international standard IP66.
8255/8260 Freezer Terminals Warning: • •
40
8255 LCD terminals are not available in a low temperature or freezer versions.
8260 LCD vehicle-mounts: Suitable for use in temperatures ranging from -30˚ C to 50˚ C (-22˚ F to 122˚ F). VFD and EL vehicle-mounts: Suitable for use in temperatures ranging from -30˚ C to 60˚ C (-22˚ F to 140˚ F).
Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 67
Chapter 2: Assembly And Basic Operation Important Operating Instructions Important:
• •
You can cold start a vehicle-mount freezer terminal at temperatures as low as -30˚ C. HOWEVER, cold starting an 8255 or 8260 freezer terminal at or below -20˚ C results in a radio warm-up period. An onscreen message indicates that the terminal is in radio warm-up mode and displays the expected radio “on” temperature and the actual temperature. Designed for condensing freezer and outdoor environments. Input power 24 – 48 VDC.
8255/8260 Low Temp. Terminals Warning:
• • • • •
While low temperature vehicle-mount terminals will operate at temperatures as low as -30˚ C, THEY CANNOT BE COLD STARTED AT TEMPERATURES BELOW -20˚ C.
8260 LCD vehicle-mounts: Suitable for use in temperatures ranging from -30˚ C to 50˚ C (-22˚ F to 122˚ F). VFD and EL vehicle-mounts: Suitable for use in temperatures ranging from -30˚ C to 60˚ C (-22˚ F to 140˚ F). Designed for use in outdoor vehicle cab applications. Water sealed to withstand rain. Input power: 8255/8260 12 VDC
2.12.3 Important Operating Instructions Warning:
IT IS CRITICAL that this information be reviewed and that any guidelines applicable to your terminal be strictly followed.
2.12.3.1 For All Freezer Terminals • • •
Use terminals only in the environments for which they are designed. DO NOT open the terminal casing and attempt to perform repairs. Only Teklogix technicians are qualified to open and repair your terminal. All Teklogix freezer vehicle-mount terminals have built-in heaters where required to warm internal components. To help maintain the temperature, terminals should be switched on before entry into a freezer environment and should be left on at all times while in a freezer environment.
Teklogix 7035, 8255 & 8260 Terminals User Manual
41
Page 68
Chapter 2: Assembly And Basic Operation For Hand-Held Terminals Only • •
• •
Hand-held LCD terminals used in freezers may require some contrast adjustment if the display darkens due to a rapid drop in temperature. When moving between freezer and warm, humid environments, window condensation or icing on the outside of the display and scanner window is a normal occurrence. Wiping the condensation from these windows may help, but the operator may need to wait until the condensation stops forming before use. To reduce condensation and frost on terminal displays, use an anti-fogging agent once a week or as required. Contact lubricant and connector caps must be used on all external connectors to maintain a moisture barrier and prevent corrosion during freezer and outdoor use. For 7035 terminals, the contact lubricant – PN 93523 (Dow Corning #111) must be used. On all versions of 8255/8260 vehicle-mount terminals, the contact lubricant – PN 95146 (Nyogel) must be used. Further, the appropriate contact lubricant should be replaced at least monthly in applications requiring daily or frequent removal of cables. Refer to the table below for connector cap part numbers.
Terminal Type
Connector Cap
Part No.
7035, 8255 & 8260
28-pin Honda 20-pin Honda
94989 94988
2.12.3.2 For Hand-Held Terminals Only • •
•
42
Do not charge batteries in a freezer environment. If a hand-held terminal is left in a freezer environment for extended periods of time with the power off, display response time and contrast are severely affected. After turning the terminal on, the operator should allow a 15 minute warm-up period outside the freezer before use. Battery capacity is reduced as the operating temperature cools based on the application and the type of radio used. The table below generally outlines battery capacity based on the operating temperature.
Temperature
7035 Battery Capacity
-30˚ C (-22˚ F) -20˚ C (-4˚ F) -10˚ C (14˚ F) 0˚ C (32˚ F)
35% 45% 60% close to 80%
Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 69
Chapter 2: Assembly And Basic Operation For Vehicle-Mount Terminals Only
2.12.3.3 For Vehicle-Mount Terminals Only •
8260 LCD freezer vehicle-mount terminals have a delay programmed into the software to prevent the display backlight from turning on if the internal temperature sensor is below 10˚ C. The duration of the delay is between one and two minutes, depending on the temperature measured by the sensor. This delay is required to heat up the backlight tube, preventing damage during cold temperature start up. Although the terminal is operational during this time, it is extremely difficult to read the display until the backlight is turned on.
Warning:
Do not install a non-heated keyboard in an 8260 freezer terminal. Conversely, do not install a heated keyboard in a standard temperature 8260 terminal.
Warning:
Do not install the terminal in such a way that the power cable is bent 90˚ at the terminal. Doing so may cause damage to the power cable and power cable strain relief.
•
• •
To prevent condensation when a vehicle-mount freezer terminal is moved from a freezer to a warmer environment, it is recommended that the terminal power be left on for at least five minutes. When not in use, 8260 LCD vehicle-mount freezer terminals should be stored in temperatures above 0˚ C (32˚ F). To prevent keyboard keys from freezing up, the keyboard should be mounted off the horizontal plane. This allows water to run off the keyboard and prevents it from pooling on the keypad, freezing and finally physically jamming the keys. Mounting the keyboard off the horizontal plane also prevents water from dripping onto the keypad area.
2.13 Maintenance This section describes the measures that should be added to your equipment maintenance routine.
Teklogix 7035, 8255 & 8260 Terminals User Manual
43
Page 70
Chapter 2: Assembly And Basic Operation Cleaning All Terminals
2.13.1 Cleaning All Terminals Terminals can be cleaned with mild detergent and water. Ink marks on the keyboard can be removed using a cotton ball moistened with isopropyl alcohol. Warning:
Do not immerse the unit in water. Never use strong cleansers.
2.13.2 7035 – Special Instructions •
•
The 7035 terminal has a plastic case that is susceptible to certain chemicals. It is partially soluble in aromatic or chlorinated hydrocarbons, and slowly decomposes in strong alkaline solutions. Avoid these solvents. Do not use Loctite brand or other adhesives to secure screws used to attach accessories to the case of the 7035 since the adhesive may damage the plastic (unless the adhesives are specifically formulated for plastics). The 7035 scanner, IrDA port and display window should be cleaned with a mild detergent and water, as required. Never apply cleaners directly on the terminal – use a cloth dampened with a mild detergent.
Warning:
To avoid scratching the display and scan windows, do not use abrasive cleansers.
2.13.3 Maintaining The 7035 Battery Important:
“Lithium-Ion Battery Safety Precautions” on page 201 outlines additional safety precautions. For detailed battery specifications, refer to “Lithium-Ion Battery Pack (7035 Only)” on page 241.
7035 terminals use Lithium-Ion batteries that do not require conditioning. Each battery pack tracks its own capacity. A horizontal bar graph, referred to as a battery gauge, is displayed in the status area of the terminal screen. It keeps track of the percentage of remaining battery power capacity – 0 to 100%, resolution 10% of nominal. The operator is notified when the battery capacity is low.
44
Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 71
Chapter 2: Assembly And Basic Operation Maintaining The 7035 Battery
Warning:
BATTERIES ARE CONSIDERED HAZARDOUS WASTE and must be returned to Teklogix for proper disposal. All used batteries must be forwarded to one of the following Teklogix offices: Teklogix Inc. Teklogix Corp. 2100 Meadowvale Blvd. 1810 Airport Exchange Blvd. Mississauga, Ontario Suite 500 L5N 7J9 Erlanger, Kentucky Canada USA 41018 Teklogix S.A. Parc Club Du Golf-Bat 1. 13856 Aix-En-Provence Cedex 3; France DO NOT DISPOSE OF IN FIRE, mix with other battery types, charge above specified rate, connect improperly, or short circuit the battery. Any of these actions can result in overheating, explosion or leakage of cell contents. DO NOT INCINERATE or subject battery cells to temperatures in excess of 100°C (212°F). Such treatment can vaporize the liquid electrolyte causing cell rupture. Incineration may result in harmful emissions or explosion. DO NOT charge, use or store batteries below -30º C (-22˚ F). Batteries must be handled in accordance with all applicable state and federal laws and regulations.
Teklogix 7035, 8255 & 8260 Terminals User Manual
45