Page 259

Chapter 9: Specifications Peripheral Ports

9.4 Peripheral Ports Type Type (8255/8260 Only)

External 28-pin PCR male connector External 36-pin PCR male connector

9.4.1 Serial Port 1 (COM 1) Type Electrical Signal Lines Supported Modes Application Interface Transfer Rates Compatibility Protocols Limitations

DTE, 16550A equivalent (with 16 byte data FIFO) RS-232D signalling, maximum cable length – 50 ft. (typical – 6 ft.) RTS, CTS, TxD, RxD Standard UART with RTS/CTS handshaking Via standard 16550 h/w registers or BIOS serial device 2400 - 115,200 bps User assigned. Application dependent. For the 7035 only, COM1 is shared with the IrDA port; only one peripheral can be active at one time. No hardware handshake support for DTR, DSR, DCD, RI.

9.4.2 Serial Port 2 (COM 2) Type Electrical Signal Lines Supported Modes Application Interface Transfer Rates Compatibility Protocols Limitations

DTE, proprietary double-buffered (similar to 8251A) RS-232D signalling, maximum cable length – 50 ft. (typical – 6 ft.) TxD, RxD Basic UART (no hardware handshaking) Only through BIOS serial device. 1200 - 57,600 bps Decoded Scanners, Scan-See, download cable, GPS (serves as the “monitor” port). Application dependent. No hardware handshake support

Teklogix 7035, 8255 & 8260 Terminals User Manual

233

Page 260

Chapter 9: Specifications Memory Expansion Board

9.5 Memory Expansion Board Type Access Compatibility DRAM Flash ROM

Internal, plug-in printed circuit module Not customer upgradeable. Proprietary 8 MB 4 MB

9.6 IrDA Port (7035 Only) Function Compatibility Supported Transfer Rates Supported Modes Limitations

Intended for application download and possible batch data transfer. IrDA Specification Version 1.1 (physical and link layer) All UART rates (2400 bps – 115,200 bps) UART (Async) Shared with serial port COM 1. Only one peripheral active at a time.

9.7 Wireless Communication Options Refer to “Radio Specifications” on page 225 for a description of the radio types available for Teklogix 7035, 8255 and 8260 terminals. Descriptions also include transmission power, data rates and channel information for each radio.

9.8 GPS Unit For detailed technical information on the Garmin GPS35 HVS, please refer to the Garmin web site: www.garmin.com.

234 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 261

Chapter 9: Specifications Bar Code Scanning

9.9 Bar Code Scanning Scanner Types Decoded and non-decoded. Non-Decoded Codes Supported Code 39, code 128, EAN 13, EAN 8, EAN 128, UPC-A, UPC-E, Codabar, Code 93, Code 11, Interleaved 2-of-5, MSI/PLESSY, Discrete 2-of-5. Decoded Codes Supported Dependent on external scanner choice. Code Discrimination Automatic for all selected codes, Non-Decoded input. Decoded input is external scanner dependent.

9.9.1 Internal Scanners (7035 Only) Note: If you are using a High Performance scanner, choose High Vis for the “Scanner Type” parameter. Base Options Scan Triggering

High performance, long range, advanced long range and 2-D raster laser scanner. If an aiming dot is available on the installed scanner, the aiming dot will be enabled for a configurable time period after which normal scanning begins. Double-clicking trigger will override aiming delay and initiate immediate scan.

9.9.2 External Scanners Supported Types

Decoded and Non-Decoded 5V only.

Interface

Via peripheral port. Pinout compatible with all 7030 and 8055 scanners.

9.9.3 Internal Scanner Port (7035 Only) Refer to Table B.4 "Internal Scanner Connector" in Appendix B: Port Pinouts And Cable Diagrams for a detailed connector table. Compatibility

Symbol SE1200HP, SE1200LR, SE1223ALR, SE2223 2-D Teklogix 7035, 8255 & 8260 Terminals User Manual

235

Page 262

Chapter 9: Specifications Internal Scanner Specifications (7035 Only)

9.10 Internal Scanner Specifications (7035 Only) Parameter

7035 High Performance (SE 1200HP)

Visible Laser Diode, 675nm ± 5nm CDRH Class II Laser Class DIN EN 60825: July 1993, Class 2 1.0 mW Max. Average Radiant Laser Power Power Pulse Power Duration Continuous Scan Angle 42˚ ± 2˚ 36 ± 3 scans/second Scan Repetition (bidirectional) Skew Tolerance ± 65˚ from normal Pitch Angle ± 55˚ from normal Roll Tolerance ± 20˚ from vertical Specular Dead Zone ± 2˚ from normal See page 239. Minimum bar Decode Depth of Field width is 5.0 mil (0.127 mm) Print Contrast 20% absolute dark/light reflecMinimum tive measured at 675 nm. Ambient Light Sunlight: 8000 ft. candles Immunity Artificial Light: 450 ft. candles

Light Source

7035 Long Range (SE 1200LR) Visible Laser Diode, 650nm ± 5nm CDRH Class II DIN EN 60825: July 1993, Class 2 1.0 mW Max. Average Radiant Power Continuous 23˚ ± 2˚ 36 ± 3 scans/second (bidirectional) ± 60˚ from normal ± 65˚ from normal ± 10˚ from vertical ± 2˚ from normal See page 239. Minimum bar width is 10.0 mil (0.254 mm) 40% absolute dark/light reflectance measured at 675 nm. Sunlight: 8000 ft. candles Artificial Light: 450 ft. candles

Table 9.1 SE122HP And SE122LR Scanner Specifications Parameter Light Source Scan Rate Scan Angle Horizontal: Vertical Scan Patterns

7035 Advanced Long Range (SE 1223ALR)

7035 2-D (SE 2223 2-D)

Visible Laser Diode 650 nm Visible Laser Diode 650 nm 35 (± 5) scans/sec (bi-directional) 590 scans/sec. 22 frames/sec. 13º ± 2º Linear

236 Teklogix 7035, 8255 & 8260 Terminals User Manual

34º 12.5º Linear and Smart Raster

Page 263

Chapter 9: Specifications Internal Scanner Specifications (7035 Only)

Parameter

7035 Advanced Long Range (SE 1223ALR)

Minimum Print Contrast

Minimum 40% absolute dark/light reflectance measured at 650 nm

Symbologies

Programmable Parameters

Interfaces

Ambient Light: Artificial: Sunlight:

- 35% absolute dark/light reflectance differential (PDF) - 25% absolute dark/light reflectance differential (1-D) PDF417, Micro PDF, UPC/EAN, Code 128, Code 39, UPC/EAN, Code 39, Code 93, I 2 of 5, Discrete 2 of 5, Interleaved 2 of 5, Code 128, Codabar, MSI UCC/EAN 128, Codabar, MSI Plessey, RSS TriOptic Code 39 and Composite codes Laser On Time, Aim Duration, Laser On Time, Aim Duration, Power Mode, Trigger Mode, Power Mode, Trigger Mode, Bi-directional Redundancy, Bi-directional Redundancy, Symbology types/lengths, Symbology types/lengths, Data Data formatting, Serial Paramformatting, Serial Parameters, eters, Beeper Tone, Scan Beeper Tone Angle, Pattern controls 12 position ZIF connector. 12 position ZIF connector. Symbol Standard SSI interface Symbol Standard SSI Interface with logic level serial data with logic level serial data comcommunication plus trigger, munications plus trigger, beeper beeper and decode LED and decode LED signals signals 450 ft. candles (4,844 lux) 8,000 ft. candles (86,112 lux)

-40° to 140°F (-40° to 60°C) 5% to 95% noncondensing

450 ft.-candles/4,844 lux 8,000 ft.-candles/86,112 lux with correct enclosure. 22º to 140° F/-30º to 60º C @ 100% duty cycle -40º to 158º F/-40º to 70º C 5% to 95% noncondensing

5.0 VDC ± 10% 115 mA typical 70 µA max. 2,000 G

±5VDC ± 10% 230mA 6.5mA 2,000 G

Operating Temperature: -22º to 131ºF (-30º to 55ºC) Storage Temperature: Humidity: Power: Input Voltage: Input Current: Standby Current: Shock

7035 2-D (SE 2223 2-D)

Table 9.2 SE1223ALR And SE2223 2-D Scanner Specifications

Teklogix 7035, 8255 & 8260 Terminals User Manual

237

Page 264

Chapter 9: Specifications Internal Scanner Specifications (7035 Only)

Pitch

Pitch Angle

Scanner Side View

Scan Beam

Barcode Surface

Skew Skew Angle Scanner Barcode Surface

Top View Scan Pattern

Specular Dead Zone

< 2º

Scanner Side View

Scan Beam

Barcode Surface

Roll

Scanner Side View

Scan Beam Barcode Surface

Figure 9.1 Pitch, Skew And Specular Dead Zone

238 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 265

Chapter 9: Specifications Decode Zones

9.10.1 Decode Zones Bar Code

Spread Spectrum High Performance Min Max 3.0" 3.0" 2.5" 2.5" 2.5" 3.0" 3.5"

5 mil 7.5 mil 10 mil 15 mil 20 mil 40 mil 55 mil

4.5" 8.5" 12.5" 18.5" 20.5" 29.5" 35.5"

Advanced Long Range Min Max

Long Range Min

Max

13.0" 8.5" 9.5" 9.5" 9.5"

17.5" 33.5" 38.5" 79.5" 89.5"

20.0" 30.0" 30.0" 27.0"

50.0" 60.0" 98.0" 115.0"

Table 9.3 Decode Zones – Spread Spectrum HP, LR And ALR Bar Code

5 mil 7.5 mil 10 mil 15 mil 20 mil 40 mil 55 mil

Narrow Band High Performance Min Max

Min

Max

3.0" 5.0" 2.75" 9.0" 2.5" 13.0" 2.5" 19.0" 2.5" 21.0" 3.0" 30.0" 4.0" 36.0"

13.0" 9.0" 9.0" 10.0" 10.0"

18.0" 34.0" 39.0" 80.0" 90.0"

Advanced Long Range Min Max

Long Range

20.0" 30.0" 30.0" 27.0"

50.0" 60.0" 98.0" 115.0"

Table 9.4 Decode Zones – Narrow Band HP, LR And ALR Bar Code

Raster Laser Scanner Spread Spectrum

2D Bar Codes

S2223 Min

6.5 mil 10 mil 15 mil

2.5" 2.5" 2.5"

Max 6.5" 9.5" 15.5"

Table 9.5 Decode Zones – 2-D Scanner

Teklogix 7035, 8255 & 8260 Terminals User Manual

239

Page 266

Chapter 9: Specifications Power Management (7035 Only)

9.11 Power Management (7035 Only) BIOS Compatibility

Advanced Power Management (APM) BIOS Interface Specification, Rev 1.2.

9.11.1 Power Save States System power states are based on the APM definitions. APM Enabled

The terminal is in full power state. All functions are active and system power is managed. The “link” indicator is displayed in uppercase letters, showing that the radio is running at full power.

APM Standby

The terminal is in low power state with most devices in low power mode. The “link” indicator is displayed in lowercase letters, showing that the radio is in low power state. The CPU clock is slowed or stopped. The system state is fully retained, and the terminal returns to APM Enabled (full power) state quickly when, for example, the operator presses a key or scans a bar code. This state is not evident to the operator.

APM Suspend

The terminal enters Suspend state from APM Standby state after a configurable period of inactivity. The terminal also enters Suspend state when the <BLUE> <ENTER> key combination is pressed to turn the terminal off. In this state, the 7035 appears to be off. While the system context and memory are saved, the communication link is down and the terminal display is blank. To return to APM Enable state, the <ENTER/ON> key must be pressed. Returning to full power state takes approximately 4 seconds.

Off

The terminal enters the Off state from APM Suspend state after a configurable timeout. The terminal is completely powered off with no CPU context or memory contents saved. Only the real-time clock is maintained. To return to the APM Enabled state, the <ENTER/ON> key must be pressed. The system runs through a complete reset/reboot sequence.

240 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 267

Chapter 9: Specifications Lithium-Ion Battery Pack (7035 Only)

9.12 Lithium-Ion Battery Pack (7035 Only) Battery Pack Technology Supported pack Charge temperature Discharge temperature Life span

Lithium-Ion (Li-Ion)

Charge Cycles

PN 20605-003 10˚ C to 45˚ C (50˚ F to 113 ˚ F). -20˚ C to 60˚ C (-4˚ F to 140˚ F). Pack performance does not degrade below 80% of nominal under typical daily use over a 2 year period. (Based on one charge/discharge cycle every day and 250 working days per year.) Minimum of 500 charge cycles.

Charge Time

Fast charge typically in 3.5 to 4 hours.

Performance Monitor

Identifies the need for pack replacement.

Voltage

7.4 V nominal (6.0 V to 8.4 V maximum) for battery pack PN 20605-003

Capacity

2200 mAh at 7.4 V nominal for battery pack PN 20605-003

Weight

135 g nominal

Battery Life

- 9 hours at 23˚ C (73.4˚ F) with TRX7370 radio - 15 hours at 23˚ C (73.4˚ F) with TRX7431 radio with backlight on 5%, 5 scan transactions per minute, TESS emulation, 20605-003 battery pack. Based on typical 1 year cell degradation. Other radios will differ.

Supported Chargers

Model #7967 – 6-gang custom charger Model #7942 – In-unit charger Model #7978 – 3-gang custom charger No memory effect.

Memory Battery Gauge

Indicates remaining capacity, 0 to 100%, resolution 10%. Nominal capacity of battery pack is displayed as a reference.

Graceful Power Fail

Operator is notified when battery capacity is low. Teklogix 7035, 8255 & 8260 Terminals User Manual

241

Page 268

This page is a scan with no text; see it in the PDF.