The text of a manual · part 30 of 41
7035/8255/8260 Terminals User Manual: Specifications 9, pages 259 to 268
Pages 259 to 268 of 348, from 7035/8255/8260 Terminals User Manual
The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Teklogix 7942, Teklogix 7978, Teklogix 7035, Psion 7942 and Psion 7978
Page 259
Chapter 9: Specifications Peripheral Ports
9.4 Peripheral Ports Type Type (8255/8260 Only)
External 28-pin PCR male connector External 36-pin PCR male connector
9.4.1 Serial Port 1 (COM 1) Type Electrical Signal Lines Supported Modes Application Interface Transfer Rates Compatibility Protocols Limitations
DTE, 16550A equivalent (with 16 byte data FIFO) RS-232D signalling, maximum cable length – 50 ft. (typical – 6 ft.) RTS, CTS, TxD, RxD Standard UART with RTS/CTS handshaking Via standard 16550 h/w registers or BIOS serial device 2400 - 115,200 bps User assigned. Application dependent. For the 7035 only, COM1 is shared with the IrDA port; only one peripheral can be active at one time. No hardware handshake support for DTR, DSR, DCD, RI.
9.4.2 Serial Port 2 (COM 2) Type Electrical Signal Lines Supported Modes Application Interface Transfer Rates Compatibility Protocols Limitations
DTE, proprietary double-buffered (similar to 8251A) RS-232D signalling, maximum cable length – 50 ft. (typical – 6 ft.) TxD, RxD Basic UART (no hardware handshaking) Only through BIOS serial device. 1200 - 57,600 bps Decoded Scanners, Scan-See, download cable, GPS (serves as the “monitor” port). Application dependent. No hardware handshake support
Teklogix 7035, 8255 & 8260 Terminals User Manual
233
Page 260
Chapter 9: Specifications Memory Expansion Board
9.5 Memory Expansion Board Type Access Compatibility DRAM Flash ROM
Internal, plug-in printed circuit module Not customer upgradeable. Proprietary 8 MB 4 MB
9.6 IrDA Port (7035 Only) Function Compatibility Supported Transfer Rates Supported Modes Limitations
Intended for application download and possible batch data transfer. IrDA Specification Version 1.1 (physical and link layer) All UART rates (2400 bps – 115,200 bps) UART (Async) Shared with serial port COM 1. Only one peripheral active at a time.
9.7 Wireless Communication Options Refer to “Radio Specifications” on page 225 for a description of the radio types available for Teklogix 7035, 8255 and 8260 terminals. Descriptions also include transmission power, data rates and channel information for each radio.
9.8 GPS Unit For detailed technical information on the Garmin GPS35 HVS, please refer to the Garmin web site: www.garmin.com.
234 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 261
Chapter 9: Specifications Bar Code Scanning
9.9 Bar Code Scanning Scanner Types Decoded and non-decoded. Non-Decoded Codes Supported Code 39, code 128, EAN 13, EAN 8, EAN 128, UPC-A, UPC-E, Codabar, Code 93, Code 11, Interleaved 2-of-5, MSI/PLESSY, Discrete 2-of-5. Decoded Codes Supported Dependent on external scanner choice. Code Discrimination Automatic for all selected codes, Non-Decoded input. Decoded input is external scanner dependent.
9.9.1 Internal Scanners (7035 Only) Note: If you are using a High Performance scanner, choose High Vis for the “Scanner Type” parameter. Base Options Scan Triggering
High performance, long range, advanced long range and 2-D raster laser scanner. If an aiming dot is available on the installed scanner, the aiming dot will be enabled for a configurable time period after which normal scanning begins. Double-clicking trigger will override aiming delay and initiate immediate scan.
9.9.2 External Scanners Supported Types
Decoded and Non-Decoded 5V only.
Interface
Via peripheral port. Pinout compatible with all 7030 and 8055 scanners.
9.9.3 Internal Scanner Port (7035 Only) Refer to Table B.4 "Internal Scanner Connector" in Appendix B: Port Pinouts And Cable Diagrams for a detailed connector table. Compatibility
Symbol SE1200HP, SE1200LR, SE1223ALR, SE2223 2-D Teklogix 7035, 8255 & 8260 Terminals User Manual
235
Page 262
Chapter 9: Specifications Internal Scanner Specifications (7035 Only)
9.10 Internal Scanner Specifications (7035 Only) Parameter
7035 High Performance (SE 1200HP)
Visible Laser Diode, 675nm ± 5nm CDRH Class II Laser Class DIN EN 60825: July 1993, Class 2 1.0 mW Max. Average Radiant Laser Power Power Pulse Power Duration Continuous Scan Angle 42˚ ± 2˚ 36 ± 3 scans/second Scan Repetition (bidirectional) Skew Tolerance ± 65˚ from normal Pitch Angle ± 55˚ from normal Roll Tolerance ± 20˚ from vertical Specular Dead Zone ± 2˚ from normal See page 239. Minimum bar Decode Depth of Field width is 5.0 mil (0.127 mm) Print Contrast 20% absolute dark/light reflecMinimum tive measured at 675 nm. Ambient Light Sunlight: 8000 ft. candles Immunity Artificial Light: 450 ft. candles
Light Source
7035 Long Range (SE 1200LR) Visible Laser Diode, 650nm ± 5nm CDRH Class II DIN EN 60825: July 1993, Class 2 1.0 mW Max. Average Radiant Power Continuous 23˚ ± 2˚ 36 ± 3 scans/second (bidirectional) ± 60˚ from normal ± 65˚ from normal ± 10˚ from vertical ± 2˚ from normal See page 239. Minimum bar width is 10.0 mil (0.254 mm) 40% absolute dark/light reflectance measured at 675 nm. Sunlight: 8000 ft. candles Artificial Light: 450 ft. candles
Table 9.1 SE122HP And SE122LR Scanner Specifications Parameter Light Source Scan Rate Scan Angle Horizontal: Vertical Scan Patterns
7035 Advanced Long Range (SE 1223ALR)
7035 2-D (SE 2223 2-D)
Visible Laser Diode 650 nm Visible Laser Diode 650 nm 35 (± 5) scans/sec (bi-directional) 590 scans/sec. 22 frames/sec. 13º ± 2º Linear
236 Teklogix 7035, 8255 & 8260 Terminals User Manual
34º 12.5º Linear and Smart Raster
Page 263
Chapter 9: Specifications Internal Scanner Specifications (7035 Only)
Parameter
7035 Advanced Long Range (SE 1223ALR)
Minimum Print Contrast
Minimum 40% absolute dark/light reflectance measured at 650 nm
Symbologies
Programmable Parameters
Interfaces
Ambient Light: Artificial: Sunlight:
- 35% absolute dark/light reflectance differential (PDF) - 25% absolute dark/light reflectance differential (1-D) PDF417, Micro PDF, UPC/EAN, Code 128, Code 39, UPC/EAN, Code 39, Code 93, I 2 of 5, Discrete 2 of 5, Interleaved 2 of 5, Code 128, Codabar, MSI UCC/EAN 128, Codabar, MSI Plessey, RSS TriOptic Code 39 and Composite codes Laser On Time, Aim Duration, Laser On Time, Aim Duration, Power Mode, Trigger Mode, Power Mode, Trigger Mode, Bi-directional Redundancy, Bi-directional Redundancy, Symbology types/lengths, Symbology types/lengths, Data Data formatting, Serial Paramformatting, Serial Parameters, eters, Beeper Tone, Scan Beeper Tone Angle, Pattern controls 12 position ZIF connector. 12 position ZIF connector. Symbol Standard SSI interface Symbol Standard SSI Interface with logic level serial data with logic level serial data comcommunication plus trigger, munications plus trigger, beeper beeper and decode LED and decode LED signals signals 450 ft. candles (4,844 lux) 8,000 ft. candles (86,112 lux)
-40° to 140°F (-40° to 60°C) 5% to 95% noncondensing
450 ft.-candles/4,844 lux 8,000 ft.-candles/86,112 lux with correct enclosure. 22º to 140° F/-30º to 60º C @ 100% duty cycle -40º to 158º F/-40º to 70º C 5% to 95% noncondensing
5.0 VDC ± 10% 115 mA typical 70 µA max. 2,000 G
±5VDC ± 10% 230mA 6.5mA 2,000 G
Operating Temperature: -22º to 131ºF (-30º to 55ºC) Storage Temperature: Humidity: Power: Input Voltage: Input Current: Standby Current: Shock
7035 2-D (SE 2223 2-D)
Table 9.2 SE1223ALR And SE2223 2-D Scanner Specifications
Teklogix 7035, 8255 & 8260 Terminals User Manual
237
Page 264
Chapter 9: Specifications Internal Scanner Specifications (7035 Only)
Pitch
Pitch Angle
Scanner Side View
Scan Beam
Barcode Surface
Skew Skew Angle Scanner Barcode Surface
Top View Scan Pattern
Specular Dead Zone
< 2º
Scanner Side View
Scan Beam
Barcode Surface
Roll
Scanner Side View
Scan Beam Barcode Surface
Figure 9.1 Pitch, Skew And Specular Dead Zone
238 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 265
Chapter 9: Specifications Decode Zones
9.10.1 Decode Zones Bar Code
Spread Spectrum High Performance Min Max 3.0" 3.0" 2.5" 2.5" 2.5" 3.0" 3.5"
5 mil 7.5 mil 10 mil 15 mil 20 mil 40 mil 55 mil
4.5" 8.5" 12.5" 18.5" 20.5" 29.5" 35.5"
Advanced Long Range Min Max
Long Range Min
Max
13.0" 8.5" 9.5" 9.5" 9.5"
17.5" 33.5" 38.5" 79.5" 89.5"
20.0" 30.0" 30.0" 27.0"
50.0" 60.0" 98.0" 115.0"
Table 9.3 Decode Zones – Spread Spectrum HP, LR And ALR Bar Code
5 mil 7.5 mil 10 mil 15 mil 20 mil 40 mil 55 mil
Narrow Band High Performance Min Max
Min
Max
3.0" 5.0" 2.75" 9.0" 2.5" 13.0" 2.5" 19.0" 2.5" 21.0" 3.0" 30.0" 4.0" 36.0"
13.0" 9.0" 9.0" 10.0" 10.0"
18.0" 34.0" 39.0" 80.0" 90.0"
Advanced Long Range Min Max
Long Range
20.0" 30.0" 30.0" 27.0"
50.0" 60.0" 98.0" 115.0"
Table 9.4 Decode Zones – Narrow Band HP, LR And ALR Bar Code
Raster Laser Scanner Spread Spectrum
2D Bar Codes
S2223 Min
6.5 mil 10 mil 15 mil
2.5" 2.5" 2.5"
Max 6.5" 9.5" 15.5"
Table 9.5 Decode Zones – 2-D Scanner
Teklogix 7035, 8255 & 8260 Terminals User Manual
239
Page 266
Chapter 9: Specifications Power Management (7035 Only)
9.11 Power Management (7035 Only) BIOS Compatibility
Advanced Power Management (APM) BIOS Interface Specification, Rev 1.2.
9.11.1 Power Save States System power states are based on the APM definitions. APM Enabled
The terminal is in full power state. All functions are active and system power is managed. The “link” indicator is displayed in uppercase letters, showing that the radio is running at full power.
APM Standby
The terminal is in low power state with most devices in low power mode. The “link” indicator is displayed in lowercase letters, showing that the radio is in low power state. The CPU clock is slowed or stopped. The system state is fully retained, and the terminal returns to APM Enabled (full power) state quickly when, for example, the operator presses a key or scans a bar code. This state is not evident to the operator.
APM Suspend
The terminal enters Suspend state from APM Standby state after a configurable period of inactivity. The terminal also enters Suspend state when the <BLUE> <ENTER> key combination is pressed to turn the terminal off. In this state, the 7035 appears to be off. While the system context and memory are saved, the communication link is down and the terminal display is blank. To return to APM Enable state, the <ENTER/ON> key must be pressed. Returning to full power state takes approximately 4 seconds.
Off
The terminal enters the Off state from APM Suspend state after a configurable timeout. The terminal is completely powered off with no CPU context or memory contents saved. Only the real-time clock is maintained. To return to the APM Enabled state, the <ENTER/ON> key must be pressed. The system runs through a complete reset/reboot sequence.
240 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 267
Chapter 9: Specifications Lithium-Ion Battery Pack (7035 Only)
9.12 Lithium-Ion Battery Pack (7035 Only) Battery Pack Technology Supported pack Charge temperature Discharge temperature Life span
Lithium-Ion (Li-Ion)
Charge Cycles
PN 20605-003 10˚ C to 45˚ C (50˚ F to 113 ˚ F). -20˚ C to 60˚ C (-4˚ F to 140˚ F). Pack performance does not degrade below 80% of nominal under typical daily use over a 2 year period. (Based on one charge/discharge cycle every day and 250 working days per year.) Minimum of 500 charge cycles.
Charge Time
Fast charge typically in 3.5 to 4 hours.
Performance Monitor
Identifies the need for pack replacement.
Voltage
7.4 V nominal (6.0 V to 8.4 V maximum) for battery pack PN 20605-003
Capacity
2200 mAh at 7.4 V nominal for battery pack PN 20605-003
Weight
135 g nominal
Battery Life
- 9 hours at 23˚ C (73.4˚ F) with TRX7370 radio - 15 hours at 23˚ C (73.4˚ F) with TRX7431 radio with backlight on 5%, 5 scan transactions per minute, TESS emulation, 20605-003 battery pack. Based on typical 1 year cell degradation. Other radios will differ.
Supported Chargers
Model #7967 – 6-gang custom charger Model #7942 – In-unit charger Model #7978 – 3-gang custom charger No memory effect.
Memory Battery Gauge
Indicates remaining capacity, 0 to 100%, resolution 10%. Nominal capacity of battery pack is displayed as a reference.
Graceful Power Fail
Operator is notified when battery capacity is low. Teklogix 7035, 8255 & 8260 Terminals User Manual
241