Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 15 of 41

7035/8255/8260 Terminals User Manual: TESS Operations 5

Pages 119 to 128 of 348, from 7035/8255/8260 Terminals User Manual

The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Teklogix 7942, Teklogix 7978, Teklogix 7035, Psion 7942 and Psion 7978

Page 119

TESS OPERATIONS

5

5.1 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95 5.2 Working With Multiple Sessions . . . . . . . . . . . . . . . . . . . . . . . .95 5.3 The Field Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95 5.4 IBM 5250 Emulation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . .96 5.5 Data Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96 5.5.1 TESS Edit Modes And Cursor Movement . . . . . . . . . . . . . . . .97 5.5.2 <CLR> Key Behaviour In TESS. . . . . . . . . . . . . . . . . . . . .98 5.5.3 <DEL> Key Behaviour In TESS. . . . . . . . . . . . . . . . . . . . .99 5.6 Lock Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 5.7 Control Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

Teklogix 7035, 8255 & 8260 Terminals User Manual

93

Page 120

This page is a scan with no text; see it in the PDF.

Page 121

Chapter 5: TESS Operations Configuration TESS (Teklogix Screen Subsystem) is the normal operating mode of Teklogix terminals. Teklogix protocol emulation software resident on network controllers or a Teklogix Software Development Kit (SDK) installed in the host converts host screens to TESS commands. The 9140 Wireless Gateway and the 9150 Access Point are also equipped with protocol emulation software. Note: If the message “RESET: Press Enter” flashes at the bottom of the TESS screen when you turn on the terminal, press the <ENTER> key once.

5.1 Configuration Note: Each TESS session must have a unique name assigned to it. Refer to “Applications” on page 148 for more details. The process of renaming an existing TESS session and adding a new session is described in the section titled, “Applications” on page 148. A unique terminal number must be assigned in the “Terminal #” parameter for each TESS session. Refer to “Terminal #” in the section titled “TESS Settings” on page 161 for details.

5.2 Working With Multiple Sessions When Tekterm is launched, the first configured session will appear in the screen area. To display the next session in Tekterm when multiple sessions are running: •

Press <ALT> <F6>.

Each time this key combination is pressed, the next session window becomes active.

5.3 The Field Types Fixed Field – displays information that cannot be changed from the keyboard. Entry Field – allows the operator to enter data. This type of field is usually shown as: “........” Match Field – the host computer loads data in the format of the expected entry. If the entered data does not match the expected format, the terminal emits a long beep. Auto-tab Field – automatically moves the cursor to the next field when the current field is filled.

Teklogix 7035, 8255 & 8260 Terminals User Manual

95

Page 122

Chapter 5: TESS Operations IBM 5250 Emulation Keys Bar code only Field – is filled with data from a bar code reader. Keyboard entries are not accepted in this type of field. Serial I/O Field – is filled with data coming from a serial port. Keyboard input is not accepted in this type of field.

5.4 IBM 5250 Emulation Keys The following keys allow the Teklogix terminal to better emulate the functions of a true IBM 5250 terminal. Note: These keys are active at all times in TESS applications.

Key Function

Key Sequence

Cursor Movement

Cursor moves to the first position in the next Field Advance or <CTRL> <RIGHT> input field. If already in the last field, the cursor Tab arrow key moves to the first input field on the screen. Cursor moves to the beginning of the current <LEFT> field. If already in the first position, the cursor Field Backspace <CTRL> arrow key moves to beginning of the previous field. Current field is cleared from the cursor position <CTRL> <DOWN> to the end of the field, and the cursor moves to the Field Exit arrow key next input field. Home

<CTRL> <UP> arrow key

Cursor moves to the first input field on the screen.

5.5 Data Entry The terminal accepts data until the operator presses a key that sends a transmission to the host computer. The following actions cause the terminal to transmit:

96

•

Pressing a function key or the <ENTER> key (which is considered to be <F0>) causes the terminal to transmit.

•

Completing data entry into a “transmit on entry” field also causes the terminal to transmit.

Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 123

Chapter 5: TESS Operations TESS Edit Modes And Cursor Movement There are several ways to configure the terminal to complete a data field: •

Pressing <ENTER> after entering data.

•

Pressing a function key after entering data.

•

Pressing an arrow key after entering data.

•

Filling an auto-tab field.

5.5.1 TESS Edit Modes And Cursor Movement The TESS editing modes and cursor movements in each type of mode are described in the table below.

Field mode

Fcursor mode

Insert mode

Replace mode

Press <CTRL> f to enter field mode. In this mode, once data entry into a field has been completed, the entry cannot be changed without retyping the entire field. In field mode, the <RIGHT> and <LEFT> arrow keys do not perform any functions. Pressing the <UP> or <DOWN> arrow key completes the entry field and then, moves the cursor to the previous or next field. Press <CTRL> u to enter fcursor mode. In this mode, once data entry into a field has been completed, the entry cannot be changed without retyping the entire field. In fcursor mode, the <UP>, <DOWN>, <LEFT> and <RIGHT> arrow keys move the cursor between fields. Press <CTRL> i to enter insert mode. In this mode, data can be entered between two characters that have been previously entered. In insert mode, the <RIGHT> and <LEFT> arrow keys move the cursor right and left within a field. The <UP> and <DOWN> arrow keys complete the entry field and move the cursor to the previous or next field. Press <CTRL> r to enter replace mode. In this mode, data can be entered over previously entered characters. In replace mode, the <RIGHT> and <LEFT> arrow keys move the cursor to the right and left within a field. The <UP> and <DOWN> arrow keys complete the entry field and move the cursor to the previous or next field.

Note: When the “Enter on Arr” parameter is disabled (set to “N”), the <UP> and <DOWN> arrow keys do not complete an entry field. See page 172 for details about this parameter.

Teklogix 7035, 8255 & 8260 Terminals User Manual

97

Page 124

Chapter 5: TESS Operations <CLR> Key Behaviour In TESS

5.5.2 <CLR> Key Behaviour In TESS

Field mode

Replace mode

Insert mode

Fcursor mode

98

• In a left justified field, the <CLR> key erases all characters in the field and places the cursor in the left most position of that field. • In a right justified field, the <CLR> key erases all characters in the field and places the cursor in the right most position of that field. • If the <CLR> key is used to clear data in a field that has been pre-filled by the host application, the field is flagged as modified and the updated information is sent to the host in the next response message. • In both left and right justified fields, the <CLR> key erases characters beginning from the current cursor position to the end of the field. The cursor remains in the same position in the field. • If the <CLR> key is pressed while the cursor is in the right-most position in the field, the terminal emits a keyboard error beep. • If the <CLR> key is used to clear data in a field that has been pre-filled by the host application, the field is flagged as modified and the updated information is sent to the host in the next response message. • In both left and right justified fields, the <CLR> key erases the characters from one character position to right of the cursor to the end of the field. • If the <CLR> key is pressed while cursor is in the right most position in the field, the terminal emits a keyboard error beep. • If the <CLR> key is used to clear data in a field that has been pre-filled by the host application, the field is flagged as modified and the updated information is sent to the host in the next response message. • Refer to “Field Mode” at the beginning of this table. The <CLR> key operates in the same manner in “Fcursor mode” as it does in “Field mode”.

Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 125

Chapter 5: TESS Operations <DEL> Key Behaviour In TESS

5.5.3 <DEL> Key Behaviour In TESS

Field mode

Replace mode

• In a left justified field, the <DEL> key erases the character directly to the left of the cursor and then moves the cursor one position to the left. When the last character in the field is deleted, the field displays the value that it contained before it was modified, and the field is opened. • In a right justified field, the <DEL> key erases the character on which the cursor is positioned and shifts the remaining characters to the right by one position. When the last character in the field is deleted, the field displays the value that it contained before it was modified, and the field is opened. • If the <DEL> key is pressed when the field is empty, the terminal emits a keyboard error beep. • The <DEL> key does not delete data pre-filled by the host application. • If the <DEL> key is pressed in a field that has not been modified, the terminal emits a keyboard error beep. • If data is entered into a field and is then deleted before the field is completed, the field remains unmodified when the cursor leaves the field or when the screen is transmitted. • In a left justified field, the <DEL> key erases the character on which the cursor is positioned unless it is one position to the right of the last character in the string; in this case, the <DEL> key erases the character to the left of the cursor. • In a right justified field, the <DEL> key erases the character on which the cursor is positioned. The remaining characters are then shifted to the left of the cursor, and the cursor is shifted to the right by one position. • If the <DEL> key is pressed while the cursor is in the right-most character position of the field, the cursor does not shift to the left when that character is erased; it remains in the right-most position in the field. • When the last character in a field is erased, the field remains empty – that is, any pre-filled data is not displayed. Pressing the <DEL> key in the empty field results in a keyboard error beep. • The <DEL> key can delete data pre-filled by the host application. • If data is entered in a field and is then deleted before the field is completed, the field remains unmodified when the cursor leaves the field or when the screen is transmitted.

Teklogix 7035, 8255 & 8260 Terminals User Manual

99

Page 126

Chapter 5: TESS Operations Lock Messages

Insert mode

• In a left justified field, the <DEL> function erases the character on which the cursor is positioned, unless it is at the right end of the character string; in this case, it erases the character to the left of the cursor. When the last character in a field is erased, the field remains empty, and any further <DEL> functions in the empty field result in a keyboard error beep. • In a right justified field, the <DEL> function erases the character that is to the right of the cursor and then shifts the remaining data one position to the right. • If the <DEL> key is pressed while the cursor is in the right-most character position of that field, the cursor does not shift to the left when that character is erased; it remains in the right-most position in the field. • When the last character in a field is erased, the field remains empty – i.e. any pre-filled data is not displayed. Pressing the <DEL> key in the empty field sounds a keyboard error beep. • The <DEL> key can delete data pre-filled by the host application. • If data is entered into a field and then deleted before the field is completed, the field remains unmodified when the cursor leaves the field or when the screen is transmitted.

Fcursor mode

• Refer to “Field Mode” at the beginning of this table. The <DEL> key operates in exactly the same manner in “Fcursor mode” as it does in “Field mode”.

5.6 Lock Messages When information is transmitted to the host computer, the keyboard locks to prevent further data entry until the terminal receives a reply. A locked state is indicated by either “LOCK-B” (base) or “LOCK-H” (host) in the lower left corner of the display. When the reply is received by the terminal, the lock message disappears and the keyboard can be used again.

100 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 127

Chapter 5: TESS Operations Control Commands

5.7 Control Commands A group of <CTRL> key commands can be used within TESS to dictate how the terminal will operate under a variety of conditions. •

<CTRL> p – Reprints the last print page sent from the host. This key combination will not print anything if a print page from the host was not previously received at the terminal.

•

<CTRL> s – Displays the terminal status continuously. Below is a sample status line as it might appear at the bottom of your terminals screen: Lock-B/Lock-H fld enh

“application name”

•

<CTRL> w – Displays the terminal status when the terminal is in “Lock B” or “Lock H” mode. The status line would be similar to the sample above.

•

<CTRL> t – Displays the terminal status with the terminal number instead of the name. Lock-B/Lock-H

• rep

“terminal nn”

<CTRL> h – Displays a menu of available hosts.

Teklogix 7035, 8255 & 8260 Terminals User Manual

101

Page 128

This page is a scan with no text; see it in the PDF.