Page 61

Uploading Data to the Host PC

2.

From the program menu on the PT2000 or Top Gun (such as the one from INVPRO shown in Figure 3-70), select <F3> to display the File Options menu.

Figure 3-71: The File Options Menu

*FILE OPTIONS* F2=SEND FILE F3=ERASE FILE F4=EXIT ¤ 3.

Select <F2> to display the Send File menu.

Figure 3-72: Send File Menu

*SEND FILE* F2=SERIAL F3=WEDGE F4=EXIT ¤ 4.

Select <F2> to upload the data through the serial connection.

Keyboard Wedge Configuration To upload data from the portable installed as a keyboard wedge, complete the following steps: 1.

Connect the portable to the PC as described on Installing the Keyboard Wedge on page 21.

Figure 3-73: Asset Management Menu

ASSET MGMT ¤ F2=COLLECT F3=FILE OPTIONS F5=EXIT 2.

User’s Guide

Open the PC application and place the cursor at the location where data is to be entered.

51

Page 62

Using the PT2000 and Top Gun with PALPRO

3.

From the program menu on the PT2000 or Top Gun (such as the one from ASSETPRO shown above), select <F3> to display the File Options menu.

Figure 3-74: File Options Menu

*FILE OPTIONS* F2=SEND FILE F3=ERASE FILE F4=EXIT ¤ 4.

Select <F2> to display the Send File menu.

Figure 3-75: Send File Menu

*SEND FILE* F2=SERIAL F3=WEDGE F4=EXIT ¤ 5.

Select <F3> to upload the data through the keyboard wedge connection.

Removing Collected Data from Memory After uploading a file from the PT2000 or Top Gun to the PC, erase the file from the portable’s memory. To do so, complete the following steps: Figure 3-76: Item Tracking Menu

ITEM TRACKING ¤ F2=COLLECT F3=FILE OPTIONS F5=EXIT

52

PT2000 & Top Gun PDTs

Page 63

Turning Off the Portable

1.

From the program menu on the PT2000 or Top Gun (such as the one from TRACKPRO above), select <F3> to display the File Options menu.

Figure 3-77: File Options Menu

*FILE OPTIONS* F2=SEND FILE F3=ERASE FILE F4=EXIT ¤ 2.

Select <F3>to display the Erase File menu.

Figure 3-78: Erase File Option

*ERASE FILE* F3=ERASE F4=EXIT ¤ 3.

Press the <F3> key to erase the file.

Turning Off the Portable Turn the PT2000 or Top Gun off by pressing the green <I/O> button displayed at left. This will turn off the screen display, but it will not clear any information in the portable’s random-access memory (RAM). The portable is programmed to shut itself off automatically if it is not used for ten minutes. Change the auto-off time by scanning the appropriate bar code on page 140.

User’s Guide

53

Page 64

Using the PT2000 and Top Gun with PALPRO

Resetting the Portable To reset the PT2000 or Top Gun, remove the battery pack, alkaline batteries, or external power supply. Then press and hold down the <Alpha> and <ENTER> keys while reinserting the batteries or reconnecting the power supply. The portable will prompt to enter the current date and time. Caution: Resetting the PT2000 or Top Gun is similar to pressing <Ctrl>+<Alt>+<Delete> on a PC. All data stored in the portable’s memory will be cleared. Or, reset the PT2000 by scanning the following bar code: Reset

54

*+.*

PT2000 & Top Gun PDTs

Page 65

Care and Cleaning

Care and Cleaning With normal use, the PT2000 or Top Gun should require no maintenance. If it gets dirty, wipe it with a damp cloth.

User’s Guide

Caution:

Do not immerse the portable in liquid.

Caution:

Do not use any abrasive cleaners on the display screen.

55

Page 66

This page is a scan with no text; see it in the PDF.

Page 67

4 Programming the PT2000 and Top Gun Top Gun and the PT2000 are configured with certain default parameter settings before they are shipped from the factory. These settings will work for many applications. Change the settings by scanning the bar codes provided in this chapter and in Appendix G, Programming Bar Codes, on page 127 or by creating bar codes for specific settings. Or, download new programs to the portable from DOS or Windows.

CHAPTER CONTENTS Ove rvie w ............................................................. 46 Us ing Progra mming Utilitie s ............................... 47 PERCPROG ......................................................... 47 PDPROG.............................................................. 50 Us ing Pre de fine d De fa ults .................................. 51 Us ing Ba r Code s ................................................. 52 Guidelines for Creating Programming Bar Codes .. 52 Using Multiple Bar Codes ..................................... 53 Ge ne ra l Progra mming Pa ra me te rs ..................... 54 Setting the Hour Format, Time, and Date............. 55 S e ria l Pa ra me te rs ............................................... 56 Xmodem Protocol ................................................. 56 Code 39 and ASCII Equivalents for Serial Characters 58

Page 68

Programming the PT2000 and Top Gun

Overview PT2000 and Top Gun recognize the following commands at all times:

*/+* */-* *--* *-+* */.* *.-* *.+* *+.* *$$*

Sets the portable to alpha mode

Sets the portable to normal mode

Has the same effect as the <Clear> key

Has the same effect as the <BKSP> (backspace) key

Prepares the portable to accept a program

Sounds a low beep on the portable

Sounds a high beep on the portable

Clears all memory and resets the portable

Retrieves data if the application program stops execution and gives the PROGRAM FAILED message. Connect the portable to the PC and start the communications program, then scan this bar code. The data will transmit, one file at a time.

Enter these commands with bar codes or through the PC’s serial port. With PSC Program Generator (PPG), it is possible to embed these codes in a PPG program. For information about using PPG to program the portable, refer to the PSC Program Generator User Manual.

58

PT2000 & Top Gun PDTs

Page 69

Using Programming Utilities

Using Programming Utilities The PSC portable comes with a collection of applications and utilities on a disk. This collection is called the Portable Applications Library, or PAL. Two of the utilities, PDPROG and PERCPROG, enable programming of the portable from DOS or Windows. Note:

For complete information about PAL, including installation instructions, refer to the Fa lcon Porta ble Applica tions Libra ry (PAL) Us e r’s Guide .

Both programming utilities check the version number of the portable's operating system. If it is different from the PAL version, it installs the operating system along with the application.

PERCPROG PERCPROG is the utility used to program a PSC portable through

Windows. To customize the installation of an application, complete the following steps:

User’s Guide

1.

Connect the portable to the PC (refer to page 18 for information on getting started.).

2.

Double-click on the Portable Programmer icon in the PSC PAL program group. The PSC Portable Programmer window will open (refer to Figure 4-1).

Note:

The figures in this chapter show the utilities in Windows 95. When using a different version of Windows, the utility windows may look slightly different.

59

Page 70

Programming the PT2000 and Top Gun

Figure 4-1: The PSC Portable Programmer (PERCPROG) Main Window

3.

From the menu, select Options > Settings. The Communications Settings window will open (refer to Figure 4-2).

Figure 4-2: The Communications Settings window

4.

Note:

5.

60

Select the desired serial port. Then select OK. After changing the serial port setting, PERCPROG will keep the new setting until it is changed again. Use the icons in the PSC PAL program group (Windows 3.1) or the Start Menu (Windows 9x) to install an application. From the PSC Portable Programmer menu, select File > Open. The Program File window will open (refer to Figure 4-3). PT2000 & Top Gun PDTs